Your browser doesn't support javascript.
loading
Additional use of extrinsic warmer for intravenous CT contrast media and its impact on incidence of contrast extravasations and allergic like reactions: a prospective observational case control study.
Mahajan, A; Gupta, A; Shukla, S; Agarwal, U; Rai, P; Sable, N; Venugopal, A P; Sunthar, P; Banwar, P; Rane, P B; Thakur, M.
Afiliação
  • Mahajan A; Department of Imaging, The Clatterbridge Cancer Centre NHS Foundation Trust, L7 8YA, Liverpool, UK; Faculty of Health and Life Sciences, University of Liverpool, L7 8TX, Liverpool, UK; Department of Radiology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India; Advanced Centre for
  • Gupta A; Department of Radiology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
  • Shukla S; Department of Radiodiagnosis and Imaging, Mahamana Pandit Madan Mohan Malaviya Cancer Centre and Homi Bhabha Cancer Hospital, Tata Memorial Hospital, Varanasi, 221 005, India.
  • Agarwal U; Department of Radiology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
  • Rai P; Department of Radiology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
  • Sable N; Department of Radiology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
  • Venugopal AP; Department of Radiodiagnosis and Imaging, Mahamana Pandit Madan Mohan Malaviya Cancer Centre and Homi Bhabha Cancer Hospital, Tata Memorial Hospital, Varanasi, 221 005, India.
  • Sunthar P; Department of Radiodiagnosis and Imaging, Mahamana Pandit Madan Mohan Malaviya Cancer Centre and Homi Bhabha Cancer Hospital, Tata Memorial Hospital, Varanasi, 221 005, India.
  • Banwar P; Department of Radiology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
  • Rane PB; Indian Institute of Technology, Mumbai, India.
  • Thakur M; Department of Radiology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Clin Radiol ; 79(11): 851-860, 2024 Nov.
Article em En | MEDLINE | ID: mdl-39277429
ABSTRACT

AIMS:

To prospectively determine whether extrinsic warming of the low-osmolality CT contrast media (Iohexol 350, Iodixanol 320, Iopromide 300, and Iopamidol 300) to 37°C prior to intravenous administration affects extravasation and allergic-like reaction rates. MATERIALS AND

METHODS:

This large scale prospective case control study of adverse events included all the patients between the age group of 15-80 years undergoing routine contrast-enhanced computed tomographic (CECT) examinations from April 2018 to March 2020 at our institute. Ex vivo experiments were also performed to demonstrate change in contrast viscosity and fluid dynamics in relation to temperature.

RESULTS:

A total of 24,379 CECTs were conducted during the study period. Extrinsic warming showed a significant decrease in extravasation rates for Iohexol 350 at flow rates <3.5 mL/sec (P=0.037). No significant difference was observed with Iopromide 300 (P=0.432). Overall, a significant decrease in allergic reactions and overall contrast-related reactions (excluding physiologic reactions) was noted (P<0.001), with Iohexol 350. However, no significant difference was found with Iopromide 300. The most common physiological reaction was a sense of warmth, more prevalent in the warmed group, aligning with ex-vivo experiments demonstrating decreased viscosity with contrast warming.

CONCLUSIONS:

Extrinsic warming of contrast helps reduce the incidence of allergic-like reactions and extravasations for Iohexol 350, but no significant difference was noted with Iopromide 300 even at low injection rates (<3.5 mL/sec).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Iohexol / Tomografia Computadorizada por Raios X / Meios de Contraste / Extravasamento de Materiais Terapêuticos e Diagnósticos Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Radiol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Iohexol / Tomografia Computadorizada por Raios X / Meios de Contraste / Extravasamento de Materiais Terapêuticos e Diagnósticos Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Radiol Ano de publicação: 2024 Tipo de documento: Article