Your browser doesn't support javascript.
loading
Bone marrow dose in chest radiography: the posteroanterior vs. anteroposterior projection.
Radiology ; 133(1): 211-6, 1979 Oct.
Article em En | MEDLINE | ID: mdl-472293
ABSTRACT
The dose to active bone marrow resulting from anteroposterior (AP) and posteroanterior (PA) chest examinations was estimated using an Alderson Rando phantom and extruded lithium fluoride dosimeters. The AP projections resulted in a mean marrow dose range of 1.9-2.6 mrad (0.019-0.026 mGy) as compared to doses for PA projections of 3.4-3.8 mrad (0.034-0.038 mGy) for optimally diagnostic exposure taken at 70, 90, and 120 kVp.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Dosimetria Termoluminescente / Medula Óssea / Radiografia Torácica Limite: Humans Idioma: En Revista: Radiology Ano de publicação: 1979 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Dosimetria Termoluminescente / Medula Óssea / Radiografia Torácica Limite: Humans Idioma: En Revista: Radiology Ano de publicação: 1979 Tipo de documento: Article