Technical note: magnetic resonance imaging of agarose gel phantom for assessment of three-dimensional dose distribution in linac radiosurgery.
Br J Radiol
; 67(799): 646-8, 1994 Jul.
Article
em En
| MEDLINE
| ID: mdl-8061999
ABSTRACT
An agarose gel phantom is used to evaluate the spatial distribution of the dose delivered by a linac radiosurgery device. Dependence of the absorbed dose on the T1 relaxation time is checked. T1 magnetic resonance images show the close correspondence between the actual absorbed dose distribution and the dose distribution expected by the treatment planning.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Imageamento por Ressonância Magnética
/
Radiocirurgia
Idioma:
En
Revista:
Br J Radiol
Ano de publicação:
1994
Tipo de documento:
Article