Your browser doesn't support javascript.
loading
A CT-based Monte Carlo simulation tool for dosimetry planning and analysis.
DeMarco, J J; Solberg, T D; Smathers, J B.
Afiliação
  • DeMarco JJ; Jonsson Comprehensive Cancer Center, Department of Radiation Oncology, University of California Los Angeles, 90024-6951, USA. demarco@radonc.ucla.edu
Med Phys ; 25(1): 1-11, 1998 Jan.
Article em En | MEDLINE | ID: mdl-9472820
ABSTRACT
The Los Alamos code MCNP4A (Monte Carlo N-Particle version 4A) is currently used to simulate a variety of problems ranging from nuclear reactor analysis to boron neutron capture therapy. A graphical user interface has been developed that automatically sets up the MCNP4A geometry and radiation source requirements for a three-dimensional Monte Carlo simulation using computed tomography data. The major drawback for this dosimetry system is the amount of time to obtain a statistically significant answer. A specialized patch file has been developed that optimizes photon particle transport and dose scoring within the standard MCNP4A lattice geometry. The transport modifications produce a performance increase (number of histories per minute) of approximately 4.7 based upon a 6 MV point source centered within a 30 x 30 x 30 cm3 lattice water phantom and 1 x 1 x 1 mm3 voxels. The dose scoring modifications produce a performance increase of approximately 470 based upon a tally section of greater than 1 x 10(4) lattice elements and a voxel size of 5 mm3. Homogeneous and heterogeneous benchmark calculations produce good agreement with measurements using a standard water phantom and a high- and low-density heterogeneity phantom. The dose distribution from a typical mediastinum treatment planning setup is presented for qualitative analysis and comparison versus a conventional treatment planning system.
Assuntos
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Terapia por Captura de Nêutron de Boro / Imagens de Fantasmas Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Qualitative_research Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 1998 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Terapia por Captura de Nêutron de Boro / Imagens de Fantasmas Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Qualitative_research Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 1998 Tipo de documento: Article