Exercise performance and chronotropic response in heart failure patients with implantable left ventricular assist devices.
Am J Cardiol
; 81(10): 1230-2, 1998 May 15.
Article
em En
| MEDLINE
| ID: mdl-9604956
ABSTRACT
During metabolic stress testing, 9 of 20 patients with left ventricular assist devices exhibited a lag in peak device rate by < or = 85% of peak native heart rate (group I), with peak device rates of 118 +/- 9 beats/min compared with group II, in which peak device rate nearly equaled peak native rates. Peak systolic blood pressure was significantly greater in group II than group I, but there was no significant difference in peak oxygen consumption, anaerobic threshold, or peak flows.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Baixo Débito Cardíaco
/
Exercício Físico
/
Coração Auxiliar
/
Frequência Cardíaca
Limite:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Am J Cardiol
Ano de publicação:
1998
Tipo de documento:
Article