Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Acta sci. vet. (Impr.) ; 49(supl.1): Pub. 672, 2021. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1362903

Resumo

Background: The giant anteater is considered a species vulnerable to trauma due to being slow and, therefore, vulnerable to long bone fractures, such as femoral fracture. Locking plates have the potential to restore and maintain fractured bone stability, as well as reduce damage to the vascular supply. This study aims at reporting cases of two giant anteaters subjected to femoral osteosynthesis using locking plates. Cases: Two giant anteaters presenting non-weight bearing lameness on the right pelvic limbs were evaluated, diagnosed with femoral fracture of unknown etiology and submitted to osteosynthesis. A clinical evaluation was performed under chemical restraint for the adult animal and physical restraint for the young one. Crepitation and swelling in the right femur topography led to a radiographic examination, which showed a complete and transverse diaphyseal fracture of the right femur in both cases. The first one was an adult male and was subjected to osteosynthesis of the right femur using a locking plate. Once anesthetized, the animal was placed in left lateral recumbency, and the right pelvic limb was clipped and sterilized. A craniolateral incision was made to expose the femoral diaphysis. A large amount of fibrous-looking tissue was found and removed. Subsequently, the fracture was reduced and the locking plate system was positioned on the craniolateral side of the femur. An osteotomy of the femoral trochanteric crest was required to position the implant. The overlying fascia lata was closed using monofilament suture in a simple continuous pattern. The closure of the subcutaneous tissue and skin was performed using a Cushing pattern and simple interrupted pattern, respectively. Immediate postoperative radiographic examinations showed fracture reduction and bone axis alignment, with a properly positioned implant. The surgical wound was cleaned daily with 0.5% aqueous chlorhexidine solution. Seven days after surgery, the animal had a partial dehiscence at the suture site, with bone and plate exposure. Wound healing by second intention was initiated. At 127 days after surgery, a radiographic examination showed periosteal bone proliferation in the middle third of the right femur and that the bone implants were well-positioned. The second case was of a young 3.68 kg female anteater. The surgery was performed as described for the adult one, but there was no fibrosis at the fracture site and the osteotomy of the femoral trochanteric crest was not required. Closure of the fascia lata, subcutaneous tissue, and skin was performed as in Case 1. An immediate postoperative radiographic examination showed fracture reduction, bone axis alignment, and a properly positioned implant. The surgical wound was cleaned daily with 0.5% aqueous chlorhexidine solution. On the day of the surgery, the animal could already bear weight on its right pelvic limb, presenting discrete lameness with gradual improvement. Twenty-three days after surgery, a radiographic examination showed moderate periosteal bone proliferation in the middle third of the right femur. The bone implant was still well-positioned and bone healing was achieved around the 40th post-operative day. Discussion: The cases are very similar, but the younger anteater's femoral trochanteric crest didn't prevent positioning the plate. The fibrosis observed on the adult specimen is indicative of a chronic fracture, which may explain, in conjunction with the post-surgical complications, the longer time required for bone healing in the adult animal. Even so, both animals recovered fully and it's safe to deduce that the locking plate is an adequate option for internal fixation in transverse diaphyseal femoral fractures in both adult and young giant anteaters.(AU)


Assuntos
Animais , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Eutérios/lesões , Fixação Interna de Fraturas/veterinária , Placas Ósseas/veterinária , Animais Selvagens/cirurgia
2.
R. bras. Parasitol. Vet. ; 28(4): 779-785, 2019. graf, ilus
Artigo em Inglês | VETINDEX | ID: vti-25469

Resumo

A free-living, adult male maned wolf (Chrysocyon brachyurus) was referred to the Governador Laudo Natel FCAV/Unesp veterinary hospital after being found with skin lesions and a fracture on the right pelvic limb, which had to be amputated due to compromised integrity. Around 20 days later, bilateral accentuated swollen on humerus-radius-ulna articulation was observed. The synovial liquid was drained and sent to the laboratory for synovial cytology with Rosenfeld staining that revealed predominantly degenerated neutrophils with karyolytic chromatin associated with intracellular inclusions suggestive of Hepatozoon sp. gametocytes. Blood and synovial liquid samples were submitted to molecular analysis, aiming to amplify the Hepatozoon spp. 18S rRNA gene fragment. Despite the positioning of the found Hepatozoon sequence together with Hepatozoon canis previously detected in domestic carnivores, the BLAST analysis showed only 98% identity with H. canis. To the best of the authors knowledge, this is the first time a Hepatozoon was detected in the synovial liquid by clinical pathology and molecular analyses.(AU)


Um lobo guará (Chrysocyon brachyurus) adulto, macho, de vida livre foi encaminhado para atendimento no hospital veterinário Governador Laudo Natel FCAV/Unesp após ser encontrado com lesões de pele e fratura em membro pélvico direito, sendo amputado devido a comprometimento da integridade do membro. Aproximadamente 20 dias após a chegada ao hospital, foi notado acentuado aumento de volume bilateral em região de articulação úmero-rádio-ulnar. O líquido sinovial foi drenado e enviado para análise citológica com coloração de Rosenfeld, revelando a presença de neutrófilos degenerados com cromatina cariolítica associados a inclusões intracelulares sugestivas de gametócitos de Hepatozoon sp. Amostras de sangue e líquido sinovial foram submetidas a análises moleculares visando amplificar um fragmento do gene 18S rRNA de Hepatozoon spp. Apesar da sequência de Hepatozoon detectada se posicionar filogeneticamente no mesmo clado que H. canis previamente detectado em carnívoros domésticos, o resultado da análise do BLAST mostrou somente 98% de identidade com H. canis. De acordo com o conhecimento dos autores, esta é a primeira vez que Hepatozoon foi detectado no líquido sinovial por meio de patologia clínica e análises moleculares.(AU)


Assuntos
Animais , Canidae/microbiologia , Eucoccidiida/microbiologia , Líquido Sinovial
3.
Acta sci. vet. (Impr.) ; 46(supl): 1-5, 2018. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1457917

Resumo

Background: Locking bone plates for internal fixation are characterized by plates with a locknut by screwing in a threaded chamber. The increased stability associated with less vascular lesion contribute to the lower risk of complications and makes the locking bone plates especially interesting in fracture management of wild animals to be reintroduced into nature. The aim of this report is to describe the case of a black capuchin monkey with a femoral fracture, submitted to internal fixation using locking plate, with a satisfactory postoperative evolution, characterized by the bone consolidation and full recovery of the function of the member.Case: An exemplar of an adult male black capuchin monkey (Sapajus nigritus) with 4.2 kg of body weight was presented due to a comminuted, diaphyseal fracture of the left femur. The animal was then submitted to internal fixation of the femoral fracture using a 2.0 mm locking plate with 11 holes. For the internal fixation, the plate was contoured and positioned on the lateral surface of the bone. In addition, four locking screws were inserted through both cortices in the proximal bone segment, while other three locking screws were inserted in the distal bone segment. Two of the distal locking screws were inserted through both bone cortices, while one of them were inserted through only one bone cortical. The animal showed complete functional recovery of the left hind limb at 30 days postoperatively. Despite this, it was visualized at the radiographic examination a partial release of the plate from the distal bone segment. Due to this, the animal was submitted to another surgical intervention to replace the distal locking screws by bicortical locking screws. The animal showed hind limb weight support at the second day postoperatively. The complete functional recovery of the left hind limb, however, was verified at 26 days postoperatively.[...]


Assuntos
Animais , Cebidae/cirurgia , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Fraturas do Fêmur/cirurgia , Placas Ósseas/veterinária , Animais Selvagens/cirurgia
4.
Acta sci. vet. (Online) ; 46(supl): 1-5, 2018. ilus
Artigo em Inglês | VETINDEX | ID: vti-726504

Resumo

Background: Locking bone plates for internal fixation are characterized by plates with a locknut by screwing in a threaded chamber. The increased stability associated with less vascular lesion contribute to the lower risk of complications and makes the locking bone plates especially interesting in fracture management of wild animals to be reintroduced into nature. The aim of this report is to describe the case of a black capuchin monkey with a femoral fracture, submitted to internal fixation using locking plate, with a satisfactory postoperative evolution, characterized by the bone consolidation and full recovery of the function of the member.Case: An exemplar of an adult male black capuchin monkey (Sapajus nigritus) with 4.2 kg of body weight was presented due to a comminuted, diaphyseal fracture of the left femur. The animal was then submitted to internal fixation of the femoral fracture using a 2.0 mm locking plate with 11 holes. For the internal fixation, the plate was contoured and positioned on the lateral surface of the bone. In addition, four locking screws were inserted through both cortices in the proximal bone segment, while other three locking screws were inserted in the distal bone segment. Two of the distal locking screws were inserted through both bone cortices, while one of them were inserted through only one bone cortical. The animal showed complete functional recovery of the left hind limb at 30 days postoperatively. Despite this, it was visualized at the radiographic examination a partial release of the plate from the distal bone segment. Due to this, the animal was submitted to another surgical intervention to replace the distal locking screws by bicortical locking screws. The animal showed hind limb weight support at the second day postoperatively. The complete functional recovery of the left hind limb, however, was verified at 26 days postoperatively.[...](AU)


Assuntos
Animais , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Fraturas do Fêmur/cirurgia , Cebidae/cirurgia , Placas Ósseas/veterinária , Animais Selvagens/cirurgia
5.
Acta sci. vet. (Impr.) ; 44(supl): 01-04, 2016. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1457558

Resumo

Background: The Brazilian fox (Pseudalopex vetulus, Lund 1842) is a naturally endemic specie of the Brazilian savanna vegetation. Due to the rapid destruction of its habitat, the specie is considered vulnerable and subject to different kinds of trauma that usually results in fractures and dislocations. Among the methods of fractures fixation, highlights the external skeletal fixator intramedullary pin tie-in which consists of the intramedullary pin associated to the external fixator. The aim of the present report was to describe the case of a Brazilian fox with a comminuted tibial fracture, submitted to osteosynthesis using an external skeletal fixator intramedullary pin tie-in. Case: It was attended an exemplar of Pseudalopex vetulus, male, young adult, with 3.9 kg body weight and history of functional impotence of the left hindlimb. At the physical and orthopedic evaluations were observed loss of bone continuity and crepitus in tibial region, and the presence of a contaminated lacerating skin wound about 3 cm in diameter in the lateral side of the injured limb. Craniocaudal and mediolateral radiographic projections of the left hindlimb revealed the presence of a complete comminuted fracture at the proximal and distal shaft of the left tibia; and a complete transverse fracture at mid shaft of the left fibula. Due to this, the animal was submitted to fracture fixation [...]


Assuntos
Animais , Fixadores Externos/veterinária , Fixação Intramedular de Fraturas/veterinária , Fraturas da Tíbia/reabilitação , Fraturas da Tíbia/veterinária , Raposas/cirurgia , Animais Selvagens/cirurgia , Fixação Interna de Fraturas/veterinária , Pinos Ortopédicos/veterinária
6.
Acta sci. vet. (Online) ; 44(supl): 01-04, 2016. ilus
Artigo em Inglês | VETINDEX | ID: vti-483733

Resumo

Background: The Brazilian fox (Pseudalopex vetulus, Lund 1842) is a naturally endemic specie of the Brazilian savanna vegetation. Due to the rapid destruction of its habitat, the specie is considered vulnerable and subject to different kinds of trauma that usually results in fractures and dislocations. Among the methods of fractures fixation, highlights the external skeletal fixator intramedullary pin tie-in which consists of the intramedullary pin associated to the external fixator. The aim of the present report was to describe the case of a Brazilian fox with a comminuted tibial fracture, submitted to osteosynthesis using an external skeletal fixator intramedullary pin tie-in. Case: It was attended an exemplar of Pseudalopex vetulus, male, young adult, with 3.9 kg body weight and history of functional impotence of the left hindlimb. At the physical and orthopedic evaluations were observed loss of bone continuity and crepitus in tibial region, and the presence of a contaminated lacerating skin wound about 3 cm in diameter in the lateral side of the injured limb. Craniocaudal and mediolateral radiographic projections of the left hindlimb revealed the presence of a complete comminuted fracture at the proximal and distal shaft of the left tibia; and a complete transverse fracture at mid shaft of the left fibula. Due to this, the animal was submitted to fracture fixation [...](AU)


Assuntos
Animais , Raposas/cirurgia , Fraturas da Tíbia/reabilitação , Fraturas da Tíbia/veterinária , Fixadores Externos/veterinária , Fixação Intramedular de Fraturas/veterinária , Pinos Ortopédicos/veterinária , Fixação Interna de Fraturas/veterinária , Animais Selvagens/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA