Acta cir. bras. ; 31(3): 161-167, mar. 2016. ilus
Artigo em Inglês | VETINDEX | ID: vti-20826

Resumo

PURPOSE:To develop an ex vivo model for the analysis of macroscopic, histological and immunohistochemical changes after experimental endovenous laser ablation (EVLA) of the great saphenous vein (GSV).METHODS:We describe a model produced with glass tubes and introducer sheaths to mimic the physiological conditions of EVLA procedures, such as tumescence and blood flow. A pilot study was conducted to evaluate an ex vivo procedure of EVLA of an incompetent GSV segment using a 1470-nm radial fiber diode laser (7 W power) and an automatic pull-back device. The vein segment was analyzed macroscopically and by hematoxylin & eosin staining, elastic fiber histochemistry, Gomori's trichrome staining, and alpha-smooth muscle actin immunohistochemistry.RESULTS:No perforations were observed macroscopically. No muscle cell adhesion was observed in the central part of the ablated vein, showing tissue disruption. There was low labeling for elastic fibers, disruption of muscle fibers, and a reduced expression of the specific marker for this cell type.CONCLUSION:This ex vivo endovenous laser ablation model is a low cost alternative to in vivo experiments, providing standardized experimental conditions.(AU)