Resumo
A flow-injection system with a AgCl(s) mini-column is proposed for the determination of total nitrogen in plant digests by flame atomic absorption spectrometry. The method is based on Ag+ removal by ammonia through the formation of the diammine argentate(I) complex and further monitoring of the released Ag+. Nitrogen was determined in seven reference samples, in three replicates, with precision and accuracy comparable to the conductimetric procedure. The system is robust, and only slight sensitivity variations ( 2 %) have been noted during extended (4 h) operating periods. Sampling rate is about 100 h-1 and measurement repeatability is fair (relative standard deviation usually 0.02).
Um sistema de análises químicas por injeção em fluxo empregando uma mini-coluna de AgCl(s) é proposto para a determinação de nitrogênio total em plantas por espectrometria de absorção atômica com chama. O método se baseia na remoção de íons Ag+ por amônia com formação do complexo diamino argentato(I) e posterior direcionamento da amostra a um espectrômetro de absorção atômica onde prata é monitorada. Nitrogênio foi determinado em sete amostras de referência (três replicatas) com precisão e exatidão comparáveis às do procedimento condutimétrico. O sistema é estável, apresentando apenas pequenas variações em sensibilidade ( 2 %) durante períodos de operação de 4 horas. A velocidade analítica é de aproximadamente 100 h-1 e a repetibilidade das medidas é satisfatória (desvio padrão relativo em geral 0,02).
Resumo
A flow-injection system with a AgCl(s) mini-column is proposed for the determination of total nitrogen in plant digests by flame atomic absorption spectrometry. The method is based on Ag+ removal by ammonia through the formation of the diammine argentate(I) complex and further monitoring of the released Ag+. Nitrogen was determined in seven reference samples, in three replicates, with precision and accuracy comparable to the conductimetric procedure. The system is robust, and only slight sensitivity variations ( 2 %) have been noted during extended (4 h) operating periods. Sampling rate is about 100 h-1 and measurement repeatability is fair (relative standard deviation usually 0.02).
Um sistema de análises químicas por injeção em fluxo empregando uma mini-coluna de AgCl(s) é proposto para a determinação de nitrogênio total em plantas por espectrometria de absorção atômica com chama. O método se baseia na remoção de íons Ag+ por amônia com formação do complexo diamino argentato(I) e posterior direcionamento da amostra a um espectrômetro de absorção atômica onde prata é monitorada. Nitrogênio foi determinado em sete amostras de referência (três replicatas) com precisão e exatidão comparáveis às do procedimento condutimétrico. O sistema é estável, apresentando apenas pequenas variações em sensibilidade ( 2 %) durante períodos de operação de 4 horas. A velocidade analítica é de aproximadamente 100 h-1 e a repetibilidade das medidas é satisfatória (desvio padrão relativo em geral 0,02).