Resumo
Hyperthyroidism is a multisystemic disease arising from the excessive serum levels of the thyroid hormones, being a common endocrinopathy in cats. This study aimed at the evaluation of possible cardiac abnormalities by the echocardiographic exam in cats with induced thyrotoxicosis. Nine adult cats, regardless of sex or race and without alterations that could interfere in the study results, were used. To induce the thyrotoxicosis, levothyroxine sodium oral tablets in doses of 150µg kg-1 every 24 hours over 70 days were administered. The examinations were conducted in two stages: a time before induction, and another at the end of the experimental protocol. It was observed a statistically significant decrease in left ventricle internal diameter during systole and diastole. The others evaluated parameters didn't suffer any alteration. The mean value of the left ventricle diastolic diameter (LVDD) was 14.97mm in the initial moment, and 13.27mm in the final moment. The mean values of the left ventricle systolic diameter (LVSD) were 8.92mm and 7.92mm at the initial and final moments respectively. The others evaluated parameters didn't suffer any alteration. Thus, it was possible to characterize cardiovascular changes secondary to the excess of thyroid hormones in this short period of induction, but none of the cats presented congestive heart failure. It is emphasized the need for an early diagnosis of the feline hyperthyroidism, in order to prevent the development of cardiovascular effects of this disease.
O hipertiroidismo é uma doença multissistêmica caracterizada pela elevação dos níveis séricos dos hormônios tireoidianos, sendo uma endocrinopatia comum em gatos. O objetivo deste trabalho foi avaliar possíveis alterações cardíacas pelo exame ecocardiográfico em gatos com tirotoxicose induzida. Foram utilizados nove gatos adultos, sem distinção de sexo ou raça e sem alterações que pudessem interferir nos resultados do estudo. Para indução à tirotoxicose, foram administrados, por via oral, comprimidos, na dose de 150µg kg-1 de levotiroxina sódica, a cada 24 horas, durante 70 dias. Os exames foram realizados em dois momentos: um momento antes da indução e outro ao término do protocolo experimental. Dos parâmetros avaliados, foi observada diminuição estatisticamente significativa nos valores de diâmetro interno do ventrículo esquerdo, tanto na sístole, quanto na diástole. O diâmetro diastólico (DDVE) médio nos animais variou de 14,97mm, no momento inicial, para 13,27mm, no momento final. Os valores médios do diâmetro sistólico (DSVE) variaram de 8,92mm para 7,92mm, nos momentos inicial e final, respectivamente. Os outros parâmetros avaliados não sofreram alterações. Dessa forma, já foi possível caracterizar alterações cardiovasculares secundárias ao excesso dos hormônios tiroidianos nesse curto prazo de indução, porém não havendo a instalação de um quadro de insuficiência cardíaca congestiva. Ressalta-se a necessidade de um diagnóstico precoce do hipertiroidismo felino para evitar a evolução dos efeitos cardiovasculares dessa enfermidade.
Resumo
Hyperthyroidism is a multisystemic disease arising from the excessive serum levels of the thyroid hormones, being a common endocrinopathy in cats. This study aimed at the evaluation of possible cardiac abnormalities by the echocardiographic exam in cats with induced thyrotoxicosis. Nine adult cats, regardless of sex or race and without alterations that could interfere in the study results, were used. To induce the thyrotoxicosis, levothyroxine sodium oral tablets in doses of 150µg kg-1 every 24 hours over 70 days were administered. The examinations were conducted in two stages: a time before induction, and another at the end of the experimental protocol. It was observed a statistically significant decrease in left ventricle internal diameter during systole and diastole. The others evaluated parameters didn't suffer any alteration. The mean value of the left ventricle diastolic diameter (LVDD) was 14.97mm in the initial moment, and 13.27mm in the final moment. The mean values of the left ventricle systolic diameter (LVSD) were 8.92mm and 7.92mm at the initial and final moments respectively. The others evaluated parameters didn't suffer any alteration. Thus, it was possible to characterize cardiovascular changes secondary to the excess of thyroid hormones in this short period of induction, but none of the cats presented congestive heart failure. It is emphasized the need for an early diagnosis of the feline hyperthyroidism, in order to prevent the development of cardiovascular effects of this disease.
O hipertiroidismo é uma doença multissistêmica caracterizada pela elevação dos níveis séricos dos hormônios tireoidianos, sendo uma endocrinopatia comum em gatos. O objetivo deste trabalho foi avaliar possíveis alterações cardíacas pelo exame ecocardiográfico em gatos com tirotoxicose induzida. Foram utilizados nove gatos adultos, sem distinção de sexo ou raça e sem alterações que pudessem interferir nos resultados do estudo. Para indução à tirotoxicose, foram administrados, por via oral, comprimidos, na dose de 150µg kg-1 de levotiroxina sódica, a cada 24 horas, durante 70 dias. Os exames foram realizados em dois momentos: um momento antes da indução e outro ao término do protocolo experimental. Dos parâmetros avaliados, foi observada diminuição estatisticamente significativa nos valores de diâmetro interno do ventrículo esquerdo, tanto na sístole, quanto na diástole. O diâmetro diastólico (DDVE) médio nos animais variou de 14,97mm, no momento inicial, para 13,27mm, no momento final. Os valores médios do diâmetro sistólico (DSVE) variaram de 8,92mm para 7,92mm, nos momentos inicial e final, respectivamente. Os outros parâmetros avaliados não sofreram alterações. Dessa forma, já foi possível caracterizar alterações cardiovasculares secundárias ao excesso dos hormônios tiroidianos nesse curto prazo de indução, porém não havendo a instalação de um quadro de insuficiência cardíaca congestiva. Ressalta-se a necessidade de um diagnóstico precoce do hipertiroidismo felino para evitar a evolução dos efeitos cardiovasculares dessa enfermidade.
Resumo
Hyperthyroidism is a multisystemic disease arising from the excessive serum levels of the thyroid hormones, being a common endocrinopathy in cats. This study aimed at the evaluation of possible cardiac abnormalities by the echocardiographic exam in cats with induced thyrotoxicosis. Nine adult cats, regardless of sex or race and without alterations that could interfere in the study results, were used. To induce the thyrotoxicosis, levothyroxine sodium oral tablets in doses of 150µg kg-1 every 24 hours over 70 days were administered. The examinations were conducted in two stages: a time before induction, and another at the end of the experimental protocol. It was observed a statistically significant decrease in left ventricle internal diameter during systole and diastole. The others evaluated parameters didn't suffer any alteration. The mean value of the left ventricle diastolic diameter (LVDD) was 14.97mm in the initial moment, and 13.27mm in the final moment. The mean values of the left ventricle systolic diameter (LVSD) were 8.92mm and 7.92mm at the initial and final moments respectively. The others evaluated parameters didn't suffer any alteration. Thus, it was possible to characterize cardiovascular changes secondary to the excess of thyroid hormones in this short period of induction, but none of the cats presented congestive heart failure. It is emphasized the need for an early diagnosis of the feline hyperthyroidism, in order to prevent the development of cardiovascular effects of this disease.
O hipertiroidismo é uma doença multissistêmica caracterizada pela elevação dos níveis séricos dos hormônios tireoidianos, sendo uma endocrinopatia comum em gatos. O objetivo deste trabalho foi avaliar possíveis alterações cardíacas pelo exame ecocardiográfico em gatos com tirotoxicose induzida. Foram utilizados nove gatos adultos, sem distinção de sexo ou raça e sem alterações que pudessem interferir nos resultados do estudo. Para indução à tirotoxicose, foram administrados, por via oral, comprimidos, na dose de 150µg kg-1 de levotiroxina sódica, a cada 24 horas, durante 70 dias. Os exames foram realizados em dois momentos: um momento antes da indução e outro ao término do protocolo experimental. Dos parâmetros avaliados, foi observada diminuição estatisticamente significativa nos valores de diâmetro interno do ventrículo esquerdo, tanto na sístole, quanto na diástole. O diâmetro diastólico (DDVE) médio nos animais variou de 14,97mm, no momento inicial, para 13,27mm, no momento final. Os valores médios do diâmetro sistólico (DSVE) variaram de 8,92mm para 7,92mm, nos momentos inicial e final, respectivamente. Os outros parâmetros avaliados não sofreram alterações. Dessa forma, já foi possível caracterizar alterações cardiovasculares secundárias ao excesso dos hormônios tiroidianos nesse curto prazo de indução, porém não havendo a instalação de um quadro de insuficiência cardíaca congestiva. Ressalta-se a necessidade de um diagnóstico precoce do hipertiroidismo felino para evitar a evolução dos efeitos cardiovasculares dessa enfermidade.
Resumo
The tissue Doppler imaging (TDI) is a recent technique that allows the evaluation of the myocardium movement velocity during the cardiac cycle phases, providing important informations of the cardiac function. In veterinary medicine, studies have been realized for the characterization of cardiac contractility dysfunctions and to establish the normality patterns. The present work meant to evaluate the myocardium contractility velocity by the technique of TDI in healthy cats submitted to dissociative anesthesia. For that purpose, there were used nine cats, all adult, healthy and without sexual or breeding distinction. There were measured the values of Ea (early diastolic peak velocity), Aa (late diastolic peak velocity) and Sa (systolic peak velocity) in the lateral and septum wall sides. The mean values observed to septum Ea and septum Sa were of 7.2±2.5cm s-1 and 6.3±1.7cm s-1, respectively. The mean value obtained for lateral Ea was of 12.0±4.1cm s-1, while the mean value of lateral Sa was of 8.3±1.6cm s-1. It was obtained a mean value of 7.0±3.1cm s-1 for the lateral Aa, and 4.7±1.5cm s-1 for septum Aa. The standard of the myocardium contraction velocities mean values in the feline specie is of great importance, and it may help in the early diagnosis of heart contraction alterations. Due to the lack of studies with the TDI technique in cats, the values obtained in our work allow the realization of comparative studies, helping to apply this technique in experimental protocols and to the early diagnosis of cardiomyopathies in the feline specie.
O Doppler tecidual é uma técnica recente que permite avaliar a velocidade de movimentação do miocárdio durante as fases do ciclo cardíaco, fornecendo informações importantes da função cardíaca. Na medicina veterinária, estudos têm sido realizados para a caracterização de disfunções da contratilidade cardíaca e o estabelecimento de padrões de normalidade. O presente trabalho objetivou avaliar a velocidade de contração do miocárdio pela técnica de Doppler tecidual em gatos submetidos à anestesia dissociativa. Para tanto, foram utilizados nove gatos adultos, hígidos, sem distinção de sexo ou raça. Foram medidos os valores de Ea (velocidade máxima longitudinal no início da diástole), Aa (velocidade máxima longitudinal na sístole atrial) e Sa (velocidade máxima longitudinal na sístole ventricular) nas bordas lateral e septal do anel mitral. Os valores médios observados para Ea septal e Sa septal foram de 7,2±2,5cm s-1 e 6,3±1,7cm s-1, respectivamente. O valor médio obtido para Ea lateral foi de 12,0±4,1cm s-1, enquanto que o valor médio de Sa lateral foi de 8,3±1,6cm s-1. Foi obtido um valor médio de 7,0±3,1cm s-1 para Aa lateral e 4,7±1,5cm s-1 para Aa septal. A padronização dos valores médios da velocidade de contração do miocárdio na espécie felina é de grande importância, podendo auxiliar no diagnóstico precoce de alterações da função contrátil do coração. Em razão da escassez de estudos com a técnica de Doppler tecidual em gatos, os valores obtidos neste trabalho permitem a realização de estudos comparativos, auxiliando a aplicação dessa técnica em protocolos experimentais e no diagnóstico precoce de cardiopatias na espécie felina.
Resumo
The tissue Doppler imaging (TDI) is a recent technique that allows the evaluation of the myocardium movement velocity during the cardiac cycle phases, providing important informations of the cardiac function. In veterinary medicine, studies have been realized for the characterization of cardiac contractility dysfunctions and to establish the normality patterns. The present work meant to evaluate the myocardium contractility velocity by the technique of TDI in healthy cats submitted to dissociative anesthesia. For that purpose, there were used nine cats, all adult, healthy and without sexual or breeding distinction. There were measured the values of Ea (early diastolic peak velocity), Aa (late diastolic peak velocity) and Sa (systolic peak velocity) in the lateral and septum wall sides. The mean values observed to septum Ea and septum Sa were of 7.2±2.5cm s-1 and 6.3±1.7cm s-1, respectively. The mean value obtained for lateral Ea was of 12.0±4.1cm s-1, while the mean value of lateral Sa was of 8.3±1.6cm s-1. It was obtained a mean value of 7.0±3.1cm s-1 for the lateral Aa, and 4.7±1.5cm s-1 for septum Aa. The standard of the myocardium contraction velocities mean values in the feline specie is of great importance, and it may help in the early diagnosis of heart contraction alterations. Due to the lack of studies with the TDI technique in cats, the values obtained in our work allow the realization of comparative studies, helping to apply this technique in experimental protocols and to the early diagnosis of cardiomyopathies in the feline specie.
O Doppler tecidual é uma técnica recente que permite avaliar a velocidade de movimentação do miocárdio durante as fases do ciclo cardíaco, fornecendo informações importantes da função cardíaca. Na medicina veterinária, estudos têm sido realizados para a caracterização de disfunções da contratilidade cardíaca e o estabelecimento de padrões de normalidade. O presente trabalho objetivou avaliar a velocidade de contração do miocárdio pela técnica de Doppler tecidual em gatos submetidos à anestesia dissociativa. Para tanto, foram utilizados nove gatos adultos, hígidos, sem distinção de sexo ou raça. Foram medidos os valores de Ea (velocidade máxima longitudinal no início da diástole), Aa (velocidade máxima longitudinal na sístole atrial) e Sa (velocidade máxima longitudinal na sístole ventricular) nas bordas lateral e septal do anel mitral. Os valores médios observados para Ea septal e Sa septal foram de 7,2±2,5cm s-1 e 6,3±1,7cm s-1, respectivamente. O valor médio obtido para Ea lateral foi de 12,0±4,1cm s-1, enquanto que o valor médio de Sa lateral foi de 8,3±1,6cm s-1. Foi obtido um valor médio de 7,0±3,1cm s-1 para Aa lateral e 4,7±1,5cm s-1 para Aa septal. A padronização dos valores médios da velocidade de contração do miocárdio na espécie felina é de grande importância, podendo auxiliar no diagnóstico precoce de alterações da função contrátil do coração. Em razão da escassez de estudos com a técnica de Doppler tecidual em gatos, os valores obtidos neste trabalho permitem a realização de estudos comparativos, auxiliando a aplicação dessa técnica em protocolos experimentais e no diagnóstico precoce de cardiopatias na espécie felina.
Resumo
The tissue Doppler imaging (TDI) is a recent technique that allows the evaluation of the myocardium movement velocity during the cardiac cycle phases, providing important informations of the cardiac function. In veterinary medicine, studies have been realized for the characterization of cardiac contractility dysfunctions and to establish the normality patterns. The present work meant to evaluate the myocardium contractility velocity by the technique of TDI in healthy cats submitted to dissociative anesthesia. For that purpose, there were used nine cats, all adult, healthy and without sexual or breeding distinction. There were measured the values of Ea (early diastolic peak velocity), Aa (late diastolic peak velocity) and Sa (systolic peak velocity) in the lateral and septum wall sides. The mean values observed to septum Ea and septum Sa were of 7.2±2.5cm s-1 and 6.3±1.7cm s-1, respectively. The mean value obtained for lateral Ea was of 12.0±4.1cm s-1, while the mean value of lateral Sa was of 8.3±1.6cm s-1. It was obtained a mean value of 7.0±3.1cm s-1 for the lateral Aa, and 4.7±1.5cm s-1 for septum Aa. The standard of the myocardium contraction velocities mean values in the feline specie is of great importance, and it may help in the early diagnosis of heart contraction alterations. Due to the lack of studies with the TDI technique in cats, the values obtained in our work allow the realization of comparative studies, helping to apply this technique in experimental protocols and to the early diagnosis of cardiomyopathies in the feline specie.
O Doppler tecidual é uma técnica recente que permite avaliar a velocidade de movimentação do miocárdio durante as fases do ciclo cardíaco, fornecendo informações importantes da função cardíaca. Na medicina veterinária, estudos têm sido realizados para a caracterização de disfunções da contratilidade cardíaca e o estabelecimento de padrões de normalidade. O presente trabalho objetivou avaliar a velocidade de contração do miocárdio pela técnica de Doppler tecidual em gatos submetidos à anestesia dissociativa. Para tanto, foram utilizados nove gatos adultos, hígidos, sem distinção de sexo ou raça. Foram medidos os valores de Ea (velocidade máxima longitudinal no início da diástole), Aa (velocidade máxima longitudinal na sístole atrial) e Sa (velocidade máxima longitudinal na sístole ventricular) nas bordas lateral e septal do anel mitral. Os valores médios observados para Ea septal e Sa septal foram de 7,2±2,5cm s-1 e 6,3±1,7cm s-1, respectivamente. O valor médio obtido para Ea lateral foi de 12,0±4,1cm s-1, enquanto que o valor médio de Sa lateral foi de 8,3±1,6cm s-1. Foi obtido um valor médio de 7,0±3,1cm s-1 para Aa lateral e 4,7±1,5cm s-1 para Aa septal. A padronização dos valores médios da velocidade de contração do miocárdio na espécie felina é de grande importância, podendo auxiliar no diagnóstico precoce de alterações da função contrátil do coração. Em razão da escassez de estudos com a técnica de Doppler tecidual em gatos, os valores obtidos neste trabalho permitem a realização de estudos comparativos, auxiliando a aplicação dessa técnica em protocolos experimentais e no diagnóstico precoce de cardiopatias na espécie felina.