Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Braz. j. vet. res. anim. sci ; 48(3): 207-214, 2011. ilus, tab
Artigo em Português | VETINDEX | ID: vti-5697

Resumo

Os retalhos de padrão axial têm como característica significativa vascularização intrínseca, considerada uma vantagemsobre outras técnicas. Considerando que complicações isquêmicas podem afetar os retalhos cutâneos, técnicas desalvamento são descritas, dentre estas, a terapia por ondas de choque extracorpóreas (TOCE), descrita como capazde modular a vascularização e cicatrização dos retalhos. O presente estudo avaliou histológica e morfometricamente21 amostras de pele; destas, 14 foram submetidas à confecção do retalho axial, sendo sete tratadas também pelaTOCE, obtidas da região distal do retalho axial oris angularis, utilizado para a reconstrução de defeitos palpebraisexperimentais extensos em cães. Foram avaliadas também sete amostras de pele normal da mesma região acimadescrita (grupo controle). Não foram evidenciadas diferenças histológicas significativas no infiltrado inflamatório eatrofia epidérmica microscopicamente. Na análise morfométrica, o número de vasos, a área vascular total e a área médiaforam semelhantes entre os grupos experimentais. O retalho oris angularis associado ou não à TOCE não apresentoucaracterísticas microscópicas de complicações inflamatórias e atróficas significativas. Sinais de integridade tecidual evascularização sanguínea adequados foram observados em ambos os grupos tratados, demonstrando efetividade doretalho oris angularis. A aplicação da TOCE no retalho oris angularis, em dose única de 2500 impulsos a 0,15 mJ/mm2no pós-operatório imediato, não promoveu efeitos colaterais deletérios.(AU)


Considering that the cutaneous flap can be affected by isquemic complications the extra corporeal shock wavetherapy (ESWT) was described as rescue techniques. The present study was developed to analyze histological andwith morfometry, twenty one skin samples treated or not with the shock wave therapy, obtained from flaps distalborder, used in this study to repair eyelids experimental defects in dogs. The flap with or without ESWT did notshow any histological sign of inflammatory or atrophic alterations. Both group treated showed similar morphometricalcharacteristics. The ESWT with the protocol used in this study (2500 impulses at 0,15 mJ/mm2) did not demonstratesignificant clinical outcomes as a rescue technique when applied over the oris angularis flap, however results showed nosignals of collateral deleterious effects.(AU)


Assuntos
Animais , Cães , Pálpebras/cirurgia , Retalhos Cirúrgicos , Pele/anatomia & histologia , Procedimentos Cirúrgicos Oftalmológicos
2.
Botucatu,; s.n; 17/07/2012. 119 p.
Tese em Português | VETTESES | ID: vtt-4852

Resumo

A opacidade de cápsula posterior (OCP) é a complicação tardia mais comum após remoção da catarata por facoemulsificação e constitui uma nova barreira à passagem da luz. A modificação superficial das lentes intraoculares (LIOs) e tratamento por plasma vêm sendo estudados, com o intuito de aumentar a biocompatibilidade das mesmas e induzir menor proliferação celular com a posterior manifestação da OCP. O presente estudo teve por objetivo avaliar e comparar a OCP, bem como as variáveis clínico-oftalmológicas após facoemulsificação e implante de lente intraocular (LIO), modificada com plasma de flúor (SF6) ou de polietilenoglicol (PEG), em coelhos. Foram constituídos quatro grupos, de 10 animais cada. Todos os coelhos foram submetidos à facoemulsificação, sendo este o único procedimento no grupo GF; os animais do GL receberam o implante de LIOs hidrofílicas sem tratamento; no GP foram implantadas LIOs tratadas com plasma de flúor, e no GPeg LIOs polimerizadas com plasma de polietilenoglicol. Após o procedimento cirúrgico, foi feita a avaliação macroscópica e semiquantitativa da OCP, opacidade de cápsula anterior (OCA) e fimose capsular, pela lâmpada de fenda, bem como foi mensurada a pressão intraocular (PIO) e analisada espessura corneal e endotélio por microscopia especular. Adicionalmente, foi realizada a fotodocumentação digital por retroiluminação da cápsula posterior foram analisadas quanto à OCP, utilizando-se o software POCOman (Posterior Capsule Opacification Manual), até as doze e 24 semanas do pós-operatório, nos momentos de avaliação precoce e tardia respectivamente. Na avaliação clínica oftalmológica e do endotélio da córnea não houve diferença significativa entre os grupos. A OCP foi menos intensa nos grupos tratados por plasma, na biomicroscopia. O GF apresentou...


Intraocular lenses surface modification and plasma treatment are being studied, in order to increase the biocompatibility and induce less cell proliferation with the later manifestation of posterior capsule opacification (PCO). The present study aimed to evaluate and compare the PCO, as well as clinical and ophthalmological variables after phacoemulsification and intraocular lens implantation (IOL), modified with fluoride (SF6) plasma or poly (ethylene) glycol (PEG), in rabbits. Four groups with 10 animals each were constituted. All rabbits were submitted to phacoemulsification, being this the only procedure in GF group; the GL animals received the implant of hydrophilic IOLs; GP received fluoride plasma treated IOLs, and GPeg poly (ethylene glycol) plasma-polymerized IOLs. After the surgical procedure, the PCO macroscopic evaluation was made of the OCP, anterior capsule opacification (OCA) and capsular phimosis by slit-lamp, as well as was measured the intraocular pressure (IOP) and analyzed corneal thickness and endothelium by specular microscopy. Additionally, digital photographs by backlight of posterior capsule were analysed as to the OCP, using the software POCOman (Posterior Capsule Opacification Manual), until the 12 and 24 postoperative weeks in early and late evaluation respectively. In clinical assessing eye cornea and endothelium there was no significant difference between the groups. To slit lamp exam PCO was less intense in the groups treated by plasma. The GF had the highest rates of anterior capsule opacity and capsular phimosis in relation to groups with IOL. POCOman, was not evidenced in effect in reducing the PCO in the group treated by Fluoride in relation to non treated. The implant of IOLs treated with plasma does not promote inflammatory eye signs and endothelial additionally changes, demonstrating...

3.
Botucatu; s.n; 19/02/2009. 126 p.
Tese em Português | VETTESES | ID: vtt-3318

Resumo

O comprometimento anatômico e funcional das pálpebras, por afecções congênitas ou adquiridas, pode repercutir na integridade do bulbo ocular. Entre as técnicas de cirurgia reconstrutivas disponíveis, os retalhos de padrão axial têm a vantagem de possuir o suprimento sanguíneo intrínseco, assegurando irrigação adequada. Quando há a possibilidade de complicações isquêmicas, a aplicação da terapia por ondas de choque extracorpóreas (TOCE) é descrita como técnica de salvamento de retalhos. Na literatura veterinária consultada não há relatos da utilização do retalho de padrão axial oris angularis para a reconstrução palpebral, assim como da aplicação da TOCE como técnica de salvamento do mesmo na região facial periorbitária. O presente trabalho tem como objetivos avaliar a utilização do retalho axial oris angularis, na reconstrução de defeitos experimentais da pálpebra inferior de cães e verificar a atuação da terapia por ondas de choque extracorpóreas (TOCE) nos retalhos, bem como comparar os resultados clínicos e oftalmológicos do retalho com e sem a aplicação da terapia por ondas de choque. Foram utilizados oito cães, os quais foram submetidos ao desenvolvimento experimental do retalho oris angularis para a correção do defeito palpebral; estes foram avaliados por meio de exame clínico e oftalmológico até o período final de 60 dias. A avaliação histológica e morfométrica de amostras de pele submetidas ou não à TOCE, obtidas da região distal do retalho axial, aos 10 dias do pós-operatório, também foi realizada. O retalho de padrão axial oris angularis apresentou resultados funcionais e cosméticos favoráveis em cães. A TOCE, nos parâmetros utilizados e na região periocular, não apresentou diferença de atuação significativa como técnica de salvamento quando comparada à confecção isolada do retalho oris angularis...


The functional and anatomical compromise of the eyelids by congenital or acquired affections, can affect the integrity of the eye bulb, making necessary reconstructive surgeries techniques. Among the available techniques, axial flaps patterns where describe to cover facial defects, being its vascularization intrinsic, considered an advantage to other techniques, ensuring the appropriate vascularization, and also preserving the facial esthetics. Considering isquemic complications extracorporeal shockwave therapy (ESWT) was described such rescue technique on compromised skin flaps. There are not any veterinary references to use of an oris angularis skin flap to eyelid reconstruction as well ESWT in facial areas. The present study was developed to evaluate the oris angularis axial flap clinical performance on dogs? eyelids experimental defects reconstruction, and ESWT applicability over the distal end of the axial flap. The ophthalmologic exam was performed to determine possible prejudicial interactions between the treatments used and the eye. Eight dogs were ophthalmologic and clinically evaluated for sixty days. The skin samples treated or not with the shock wave therapy, obtained from flap?s distal border, where analyzed histological and with morfometry. The oris angularis axial skin flap presented good results, functional and esthetical, on the experimental repair of the dog?s eyelids. The ESWT with the protocol used in this study, did not demonstrate significant clinical outcomes as a rescue technique when applied over the oris angularis flap, however results showed no signals of collateral deleterious effects. The flap with or without ESWT did not show any histological sign of inflammatory or atrophic alterations. Both group treated showed similar morphometrical characteristics. The axial oris angularis skin flap was also used to repair large defects on the eyelids and nasal...

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA