Resumo
Purpose: Fluorescence spectroscopy techniques have been investigated aiming to reduce the invasiveness of methods for investigation of tissue. In transplantation procedures, it may offer the possibility of a complementary technique for the monitoring of liver grafts' conditions prior to and during the transplantation procedure stages involving cold perfusion. The objective of this study was to evaluate fluorescence spectroscopy under violet light excitation (408 nm) for the monitoring of clinical hypothermic liver transplantation procedures. Methods: Organ grafts were monitored from before the removal of the donor's body to 1 h after the implant into the receptor's body. Fluorescence spectroscopy was assessed over five stages within these transplant stages. Results: The study provided evidence of a correlation between fluorescence information collected during liver grafts transplantation and the survival of patients. Conclusions: Fluorescence spectroscopy can become a tool to monitor transplantation grafts, providing objective information for the final decision of surgeons to use organs.
Assuntos
Humanos , Espectrometria de Fluorescência/métodos , Raios Ultravioleta , Transplante de Fígado/reabilitaçãoResumo
PURPOSE: To assess the effect of two laser wavelengths, either separate or combined, on intact rat livers. METHOD: Nineteen male Wistar rats (200-300 g) were submitted to laser irradiation at 5 different sites on the liver surface.Wavelengths 660 and 780 nm were used, with a dose of irradiation of 60 J/cm2/site.The animals were divided into the groups:control (C) and animals irradiated with 660 nm laser (L1), with 780 nm laser (L2) or withboth wavelengths (L3).Mitochondrial function, mitochondrial swelling, and hepatocellular malondialdehyde (MDA) levels were determined.Data were analyzed by the Mann-Whitney test, with the level of significance set at 5%. RESULTS: There was a reduction of ADP-activated respiration (state 3) in group L1 compared to group C (p=0.0016), whereas the values of group L2 were similar to control.Group L3 also showed a reduction of state 3 (p=0.0159).There was a reduction of RCR in group L1 compared to control (p=0.0001) and to group L2 (p=0.0040).Mitochondrial swelling only differed between group L3 and control (p=0.0286).There was a increase in MDA levels in group L3 compared to control (p=0.0476) and to group L2 (p=0.0286) and in group L1 compared to group L2 (p=0.0132). CONCLUSION: Although laser irradiation reduced mitochondrial function,it did not interfere with the hepatocellular energy status.(AU)