Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Braz. j. biol ; 75(4)Nov. 2015.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1468356

Resumo

The present study analyzed the efficiency of the photo-electro-oxidation process as a method for degradation and inactivation of adenovirus in water. The experimental design employed a solution prepared from sterile water containing 5.107 genomic copies/L (gc/L) of a standard strain of human adenovirus type 5 (HAdV-5) divided into two equal parts, one to serve as control and one treated by photo-electro-oxidation (PEO) for 3 hours and with a 5A current. Samples collected throughout the exposure process were analyzed by real-time polymerase chain reaction (qPCR) for viral genome identification and quantitation. Prior to gene extraction, a parallel DNAse treatment step was carried out to assess the integrity of viral particles. Integrated cell culture (ICC) analyses assessed the viability of infection in a cell culture. The tested process proved effective for viral degradation, with a 7 log10 reduction in viral load after 60 minutes of treatment. The DNAse-treated samples exhibited complete reduction of viral load after a 75 minute exposure to the process, and ICC analyses showed completely non-viable viral particles at 30 minutes of treatment.


Resumo O presente estudo analisou a eficiência do processo de fotoeletrooxidação como metodologia para a degradação e inativação de adenovírus em água. A concepção experimental emprega uma solução preparada a partir de água estéril contendo 5,107 cópias genômicas/L (gc/L) de uma amostra padrão de adenovírus humano tipo 5 (HAdV-5), dividida em duas partes iguais, uma para servir como controle e outra tratada por fotoeletrooxidação (PEO) durante 3 horas e com uma corrente de 5A. As amostras recolhidas durante o processo de exposição foram analisadas por PCR quantitativo em tempo real (qPCR) para identificação e quantificação do genoma viral. Antes da extração de ácidos nucleicos, um passo de tratamento com DNAse paralelo foi realizado para avaliar a integridade das partículas virais. Um ensaio de qPCR integrado à cultura de células (ICC-qPCR) permitiu analisar a viabilidade de infecção em uma cultura de células. O processo mostrou-se eficaz testada para a degradação viral, com uma redução de 7 log10 da carga viral após 60 minutos de tratamento. As amostras tratadas com DNAse exibiram redução completa da carga viral após uma exposição de 75 minutos ao processo, e a análise de ICC-qPCR mostrou partículas virais completamente não-viáveis em 30 minutos de tratamento.

2.
Braz. J. Biol. ; 75(2,supl): 17-24, May 2015. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-13885

Resumo

The Sinos river Basin is an industrial region with many tanneries and electroplating plants in southern Brazil. The wastewater generated by electroplating contains high loads of salts and metals that have to be treated before discharge. After conventional treatment, this study applied an advanced oxidative process to degrade organic additives in the electroplating bright nickel baths effluent. Synthetic rinsing water was submitted to physical-chemical coagulation for nickel removal. The sample was submitted to ecotoxicity tests, and the effluent was treated by photoelectrooxidation (PEO). The effects of current density and treatment time were evaluated. The concentration of total organic carbon (TOC) was 38% lower. The toxicity tests of the effluent treated using PEO revealed that the organic additives were partially degraded and the concentration that is toxic for test organisms was reduced. (AU)


A Bacia do Rio dos Sinos é uma região do Sul do Brasil que sedia um importante pólo da indústria coureiro-calçadista incluindo, desde o beneficiamento das peles, em curtumes, à fabricação dos acessórios, em indústrias metalúrgicas e de galvanoplastia. O efluente gerado por processos galvânicos contém carga elevada de sais e metais que devem ser tratados antes do descarte. Neste artigo foi avaliada a aplicação de um processo oxidativo avançado após o tratamento convencional do efluente, visando degradar os aditivos orgânicos presentes nos efluentes dos banhos de eletrodeposição de níquel brilhante. Um efluente sintético foi tratado pelo processo físico-químico de coagulação para a remoção do níquel. A amostra foi, então, submetida a testes de ecotoxicidade e, em seguida, o efluente foi tratado pelo processo de fotoeletrooxidação (FEO). A influência da densidade de corrente e o tempo de tratamento foram avaliados. Foi verificada uma redução de carbono orgânico total superior a 38%. Os ensaios de ecotoxicidade para o efluente tratado por fotoeletroxidação indicaram que a FEO degradou parcialmente os aditivos orgânicos e reduziu a concentração que provoca efeitos tóxicos para os organismos teste. (AU)


Assuntos
Animais , Clorófitas , Cyprinidae/metabolismo , Daphnia , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/toxicidade , Poluentes Químicos da Água/toxicidade , Eletrólise , Galvanoplastia , Níquel/química , Oxirredução , Fotólise
3.
Braz. J. Biol. ; 75(2,supl): 45-49, May 2015. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-15282

Resumo

The discharge of sewage and industrial effluents containing high concentrations of pollutants in water bodies increases eutrophication. Cyanobacteria, some of the organisms whose growth is promoted by high nutrient concentrations, are resistant and produce several types of toxins, known as cyanotoxins, highly harmful to human beings. Current water treatment systems for the public water supply are not efficient in degradation of toxins. Advanced oxidation processes (AOP) have been tested for the removal of cyanotoxins, and the results have been positive. This study examines the application of photoelectrooxidation in the degradation of cyanotoxins (microcystins). The performance of the oxidative processes involved was evaluated separately: Photocatalysis, Electrolysis and Photoelectrooxidation. Results showed that the electrical current and UV radiation were directly associated with toxin degradation. The PEO system is efficient in removing cyanotoxins, and the reduction rate reached 99%. The final concentration of toxin was less than 1 µg/L of microcystin in the treated solution..(AU)


A descarga de esgotos e efluentes industriais contendo altas concentrações de poluentes nos corpos d'água aumenta a eutrofização. As cianobactérias, são organismos cujo crescimento é promovido por concentrações elevadas de nutrientes, são resistentes e produzem vários tipos de toxinas conhecidas, como cianotoxinas, altamente prejudiciais para os seres humanos. Os sistemas atuais de tratamento de água para o abastecimento público de água não são eficientes na degradação destas toxinas. Processos oxidativos avançados (POA) foram testados para a remoção de cianotoxinas, e os resultados têm sido positivos. Este estudo avalia o processo de fotoeletrooxidação (FEO) na degradação de cianotoxinas (microcistinas). Foi avaliado o desempenho dos processos envolvidos separadamente: fotocatalisis, eletrólise e fotoeletrooxidação. Os resultados mostram que a potencia da radiação UV e da corrente elétrica estão diretamente associados com a degradação de toxinas. O sistema de FEO é eficiente na remoção de cianotoxinas e a redução foi de 99%. A concentração final de toxina foi inferior a 1 g / L de microcistina na solução tratada.(AU)


Assuntos
Toxinas Bacterianas/química , Água Potável/química , /química , Microcystis/química , Purificação da Água/métodos , Eletrólise , Oxirredução , Fotólise
4.
Braz. J. Biol. ; 75(4,supl.2): 37-42, Dec. 2015. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-379206

Resumo

The present study analyzed the efficiency of the photo-electro-oxidation process as a method for degradation and inactivation of adenovirus in water. The experimental design employed a solution prepared from sterile water containing 5.107 genomic copies/L (gc/L) of a standard strain of human adenovirus type 5 (HAdV-5) divided into two equal parts, one to serve as control and one treated by photo-electro-oxidation (PEO) for 3 hours and with a 5A current. Samples collected throughout the exposure process were analyzed by real-time polymerase chain reaction (qPCR) for viral genome identification and quantitation. Prior to gene extraction, a parallel DNAse treatment step was carried out to assess the integrity of viral particles. Integrated cell culture (ICC) analyses assessed the viability of infection in a cell culture. The tested process proved effective for viral degradation, with a 7 log10 reduction in viral load after 60 minutes of treatment. The DNAse-treated samples exhibited complete reduction of viral load after a 75 minute exposure to the process, and ICC analyses showed completely non-viable viral particles at 30 minutes of treatment.(AU)


O presente estudo analisou a eficiência do processo de fotoeletrooxidação como metodologia para a degradação e inativação de adenovírus em água. A concepção experimental emprega uma solução preparada a partir de água estéril contendo 5,107 cópias genômicas/L (gc/L) de uma amostra padrão de adenovírus humano tipo 5 (HAdV-5), dividida em duas partes iguais, uma para servir como controle e outra tratada por fotoeletrooxidação (PEO) durante 3 horas e com uma corrente de 5A. As amostras recolhidas durante o processo de exposição foram analisadas por PCR quantitativo em tempo real (qPCR) para identificação e quantificação do genoma viral. Antes da extração de ácidos nucleicos, um passo de tratamento com DNAse paralelo foi realizado para avaliar a integridade das partículas virais. Um ensaio de qPCR integrado à cultura de células (ICC-qPCR) permitiu analisar a viabilidade de infecção em uma cultura de células. O processo mostrou-se eficaz testada para a degradação viral, com uma redução de 7 log10 da carga viral após 60 minutos de tratamento. As amostras tratadas com DNAse exibiram redução completa da carga viral após uma exposição de 75 minutos ao processo, e a análise de ICC-qPCR mostrou partículas virais completamente não-viáveis em 30 minutos de tratamento.(AU)


Assuntos
Adenovírus Humanos , Fragmentação do DNA , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA