Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acta sci. vet. (Impr.) ; 46: Pub.1596-2018. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1457886

Resumo

Background: In Veterinary Medicine, there are several methods for early and accurate assessment of blood flow dynamics. The Dopplerfluxometry can access the peak systolic velocity, mean velocity and end diastolic velocity, including Resistive Index and Pulsatility Index. Normal values of Dopplerfluxometry in healthy dogs allow the identification of vascular abnormalities and authors’ knowledge there are no reference regarding the values of Dopplerfluxometry of the femoral artery in healthy dogs. The aim of the study was to assess the femoral Dopplerfluxometry of adult healthy dogs by Resistive Index, Pulsatility Index, systolic and diastolic velocities, and femoral artery diameter.Materials, Methods & Results: Eighteen healthy intact beagle dogs, male and female, aging from 2 to 4 years old (mean ± SD: mean 3 ± 0.8 years), weighing from 10.1-17.9 kg [22.3-39.5 lb] [mean ± SD: 14.3 ± 2.7 kg (31.5 ± 5.96 lb)] were used. The dogs underwent to physical examination, complete blood cell count, serum biochemistry examination urinalysis, and radiographs examination, muscular and cardiac evaluation. Females had to be in anestrous. All dogs were submitted to right femoral artery Dopplerfluxometry. The dogs were positioned in dorsal recumbency by one person without any chemical restraint. A high definition ultrasound device equipped with a 3 - 13 MHz multi-frequency linear transducer was used. The right femoral artery was identified with the transducer positioned transversely on the right triangle femoral area. Peak systolic velocity, end-diastolic velocity was measured. The Resistivity Index and Pulsatility Index were calculated automatically by the ultrasound machine software. Three measurements were obtained with the Doppler spectrum. The values of peak systolic velocity, end-diastolic velocity, Resistivity Index, Pulsatility Index and femoral artery diameter were expressed as Mean ± Standard Deviation (SD).[...]


Assuntos
Animais , Adulto , Cães , Artéria Femoral/anatomia & histologia , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler/veterinária , Padrões de Referência , Pressão Sanguínea , Resistência Vascular
2.
Acta sci. vet. (Impr.) ; 46(supl): 1-8, 2018. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1457963

Resumo

Background: Adjustable nylon ties polyamide 6.6 is devices produced from the same material of surgical nylon wire and have been used in different surgical procedures in small animals and in human patient. Reports regarding the use of these devices as secondary fixation technique of femoral diaphyseal fractures in animals are rare in the literature. The aim of the present report case was to describe the use of adjustable nylon tie polyamide 6.6 as secondary fixation technique in a 3-year-old dog and 4-month-old cat, diagnosed with femoral diaphyseal fractures.Cases: Case 1. A 3-year-old female dog was presented with reluctance to support the left hind limb, with 5 days’ duration. Pain and edema on the left femoral diaphyseal region was identified. The limb was submitted to radiographic exam and revealed a closed, complete and comminuted fracture of the diaphysis of the femur, and was decided to perform a surgical stabilization by open reduction through primary fixation with intramedullary pin, and secondary fixation of bone fragments with adjustable nylon ties polyamide 6.6, as a substitute of steel cerclage wire. The bone fragments were alignment and fixated with five polyamide nylon ties. The excess was removed with a scalpel blade along the lock. Seven days after surgery the skin sutures were removed and were observed reluctance to support the left hind limb. Physiotherapy sessions were prescribed. Forty days after the surgery was performed a radiographic exam of the left hind limb which revealed alignment of the bone axis. Six months after the surgery, the owner reported that the dog supported the left hind limb. Case 2. A 4-month-old female cat was presented with history of trauma, with 24 h’s duration, and reluctance in supporting the left hind limb. On physical examination there was identified pain on the left femoral diaphyseal region.[...]


Assuntos
Animais , Gatos , Cães , Fios Ortopédicos/tendências , Fios Ortopédicos/veterinária , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Nylons
3.
Acta sci. vet. (Impr.) ; 46(supl): Pub.344-2018. ilus
Artigo em Português | VETINDEX | ID: biblio-1458012

Resumo

Background: Black Swan (Cygnus atratus Linnaeus 1766) is an aquatic bird native to Australia and non-migratory birds. Bumblefoot is a chronic, progressive, degenerative and granulomatous disease that affects the plantar region and causes inflammation and degenerative changes in plantar tissues. Given that bumblefoot incidence in free-living wild birds is low and that the literature lacks publications about bumblefoot in free-living Black Swans, the aim of the current study is to describe the first bumblefoot case reported in a free-living Black Swan (Cygnus atratus) in Mozambique who was subjected to surgical procedure.Case: An adult intact Black Swan (Cygnus atratus) weighing 7.2 kg was presented to Veterinary Hospital of the Veterinary Medicine School, Mozambique with reluctance to support the left hind limb. Water intake was not unsettled and urine and feces were normal. A brown mass with 3 cm diameter approximately was identified in the footpad of the left hind limb; there were local bleeding and ulcers and pain. Footpad radiographic images of the left hind limb showed no abnormalities in the bone tissue. An incisional biopsy was performed with patient under sedation. The cytopathological examination was suggestive of bumblefoot. An excisional biopsy was performed with patient under anesthesia. The mass was excised with surgical margin of 1 cm and the local was subjected to debridement. The sample was sent to histopathological examination. The histopathological examination confirmed a chronic Bumblefoot Type 2. The patient started to support the left hind limb three days after surgery and twenty days after surgery, the footpad sutures were removed. Fifty days after the surgical procedure the patient was released in the site it was rescued.[...]


Assuntos
Animais , Anseriformes , Dermatite de Contato/diagnóstico , Dermatite de Contato/tratamento farmacológico , Dermatite de Contato/veterinária , Doenças do Pé/cirurgia , Doenças do Pé/veterinária , Animais Selvagens , Moçambique
4.
Acta sci. vet. (Online) ; 46(supl): 1-8, 2018. ilus
Artigo em Inglês | VETINDEX | ID: vti-19009

Resumo

Background: Adjustable nylon ties polyamide 6.6 is devices produced from the same material of surgical nylon wire and have been used in different surgical procedures in small animals and in human patient. Reports regarding the use of these devices as secondary fixation technique of femoral diaphyseal fractures in animals are rare in the literature. The aim of the present report case was to describe the use of adjustable nylon tie polyamide 6.6 as secondary fixation technique in a 3-year-old dog and 4-month-old cat, diagnosed with femoral diaphyseal fractures.Cases: Case 1. A 3-year-old female dog was presented with reluctance to support the left hind limb, with 5 days duration. Pain and edema on the left femoral diaphyseal region was identified. The limb was submitted to radiographic exam and revealed a closed, complete and comminuted fracture of the diaphysis of the femur, and was decided to perform a surgical stabilization by open reduction through primary fixation with intramedullary pin, and secondary fixation of bone fragments with adjustable nylon ties polyamide 6.6, as a substitute of steel cerclage wire. The bone fragments were alignment and fixated with five polyamide nylon ties. The excess was removed with a scalpel blade along the lock. Seven days after surgery the skin sutures were removed and were observed reluctance to support the left hind limb. Physiotherapy sessions were prescribed. Forty days after the surgery was performed a radiographic exam of the left hind limb which revealed alignment of the bone axis. Six months after the surgery, the owner reported that the dog supported the left hind limb. Case 2. A 4-month-old female cat was presented with history of trauma, with 24 hs duration, and reluctance in supporting the left hind limb. On physical examination there was identified pain on the left femoral diaphyseal region.[...](AU)


Assuntos
Animais , Gatos , Cães , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Fios Ortopédicos/tendências , Fios Ortopédicos/veterinária , Nylons
5.
Acta sci. vet. (Online) ; 46(supl): Pub. 344, 2018. ilus
Artigo em Português | VETINDEX | ID: vti-20000

Resumo

Background: Black Swan (Cygnus atratus Linnaeus 1766) is an aquatic bird native to Australia and non-migratory birds. Bumblefoot is a chronic, progressive, degenerative and granulomatous disease that affects the plantar region and causes inflammation and degenerative changes in plantar tissues. Given that bumblefoot incidence in free-living wild birds is low and that the literature lacks publications about bumblefoot in free-living Black Swans, the aim of the current study is to describe the first bumblefoot case reported in a free-living Black Swan (Cygnus atratus) in Mozambique who was subjected to surgical procedure.Case: An adult intact Black Swan (Cygnus atratus) weighing 7.2 kg was presented to Veterinary Hospital of the Veterinary Medicine School, Mozambique with reluctance to support the left hind limb. Water intake was not unsettled and urine and feces were normal. A brown mass with 3 cm diameter approximately was identified in the footpad of the left hind limb; there were local bleeding and ulcers and pain. Footpad radiographic images of the left hind limb showed no abnormalities in the bone tissue. An incisional biopsy was performed with patient under sedation. The cytopathological examination was suggestive of bumblefoot. An excisional biopsy was performed with patient under anesthesia. The mass was excised with surgical margin of 1 cm and the local was subjected to debridement. The sample was sent to histopathological examination. The histopathological examination confirmed a chronic Bumblefoot Type 2. The patient started to support the left hind limb three days after surgery and twenty days after surgery, the footpad sutures were removed. Fifty days after the surgical procedure the patient was released in the site it was rescued.[...](AU)


Assuntos
Animais , Anseriformes , Dermatite de Contato/diagnóstico , Dermatite de Contato/tratamento farmacológico , Dermatite de Contato/veterinária , Doenças do Pé/veterinária , Doenças do Pé/cirurgia , Animais Selvagens , Moçambique
6.
Acta sci. vet. (Online) ; 46: Pub. 1596, 2018. ilus
Artigo em Inglês | VETINDEX | ID: vti-734613

Resumo

Background: In Veterinary Medicine, there are several methods for early and accurate assessment of blood flow dynamics. The Dopplerfluxometry can access the peak systolic velocity, mean velocity and end diastolic velocity, including Resistive Index and Pulsatility Index. Normal values of Dopplerfluxometry in healthy dogs allow the identification of vascular abnormalities and authors knowledge there are no reference regarding the values of Dopplerfluxometry of the femoral artery in healthy dogs. The aim of the study was to assess the femoral Dopplerfluxometry of adult healthy dogs by Resistive Index, Pulsatility Index, systolic and diastolic velocities, and femoral artery diameter.Materials, Methods & Results: Eighteen healthy intact beagle dogs, male and female, aging from 2 to 4 years old (mean ± SD: mean 3 ± 0.8 years), weighing from 10.1-17.9 kg [22.3-39.5 lb] [mean ± SD: 14.3 ± 2.7 kg (31.5 ± 5.96 lb)] were used. The dogs underwent to physical examination, complete blood cell count, serum biochemistry examination urinalysis, and radiographs examination, muscular and cardiac evaluation. Females had to be in anestrous. All dogs were submitted to right femoral artery Dopplerfluxometry. The dogs were positioned in dorsal recumbency by one person without any chemical restraint. A high definition ultrasound device equipped with a 3 - 13 MHz multi-frequency linear transducer was used. The right femoral artery was identified with the transducer positioned transversely on the right triangle femoral area. Peak systolic velocity, end-diastolic velocity was measured. The Resistivity Index and Pulsatility Index were calculated automatically by the ultrasound machine software. Three measurements were obtained with the Doppler spectrum. The values of peak systolic velocity, end-diastolic velocity, Resistivity Index, Pulsatility Index and femoral artery diameter were expressed as Mean ± Standard Deviation (SD).[...](AU)


Assuntos
Animais , Adulto , Cães , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler/veterinária , Artéria Femoral/anatomia & histologia , Padrões de Referência , Resistência Vascular , Pressão Sanguínea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA