Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acta sci. vet. (Impr.) ; 50: Pub.1851-2022. ilus, graf
Artigo em Inglês | VETINDEX | ID: biblio-1458526

Resumo

Background: Orthopedic implants are commonly used for different types of surgical procedures to gain optimal functionand to provide stability to both bones and tendon structures. When inserting these implants, the characteristics of the material are important for surgical success, and the ideal implant must be biocompatible and nonallergenic. However, whenmolding an implant to the bone structure, its resistance can change significantly. Implants can be temporary or permanentin the body, and metal possesses properties that make it acceptable for bone repair. In biomedical implants, 2 types aremost common, commercially pure (CP)-Ti and Ti-6A1-4V. They both provide stable fixation and low risk of loosening.Implants made with the same material and composition can perform differently if the material has been altered by processing techniques for different scenarios. Stress, strain and elastic modulus are the primary metrics used in the description ofimplant materials. They can be calculated based on mechanical tests of specimens with defined geometry, most commonlytensile, bending and torsional tests. In order to better evaluate those changes, we compared the mechanical characteristicsof titanium bone plates, before and after they were molded to the bone, to verify and quantify the loss of stiffness andresistance after molding the plate.Materials, Methods & Results: The study was prospective. Orthopedic implant made of commercially pure titanium (CPTi) were divided into 2 groups, one group without plate molding and the other with plate molding to a dog femora bone.Thirty-six plates of different sizes (5.0, 6.5, 8.0, 9.0, 10.0- and 11.0-mm diameter) were divided into 6 groups containing6 plates of each size and submitted to the 4-point flexion test of resistance, using a piece of dog femur (weights of 5, 10,15, 20 and 25 kg) as the bone in which the...


Assuntos
Animais , Cães , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Materiais Biocompatíveis , Placas Ósseas/veterinária , Titânio/análise , Próteses e Implantes/veterinária
2.
Acta sci. vet. (Online) ; 50: Pub. 1851, Jan. 19, 2022. ilus, graf
Artigo em Inglês | VETINDEX | ID: vti-765215

Resumo

Background: Orthopedic implants are commonly used for different types of surgical procedures to gain optimal functionand to provide stability to both bones and tendon structures. When inserting these implants, the characteristics of the material are important for surgical success, and the ideal implant must be biocompatible and nonallergenic. However, whenmolding an implant to the bone structure, its resistance can change significantly. Implants can be temporary or permanentin the body, and metal possesses properties that make it acceptable for bone repair. In biomedical implants, 2 types aremost common, commercially pure (CP)-Ti and Ti-6A1-4V. They both provide stable fixation and low risk of loosening.Implants made with the same material and composition can perform differently if the material has been altered by processing techniques for different scenarios. Stress, strain and elastic modulus are the primary metrics used in the description ofimplant materials. They can be calculated based on mechanical tests of specimens with defined geometry, most commonlytensile, bending and torsional tests. In order to better evaluate those changes, we compared the mechanical characteristicsof titanium bone plates, before and after they were molded to the bone, to verify and quantify the loss of stiffness andresistance after molding the plate.Materials, Methods & Results: The study was prospective. Orthopedic implant made of commercially pure titanium (CPTi) were divided into 2 groups, one group without plate molding and the other with plate molding to a dog femora bone.Thirty-six plates of different sizes (5.0, 6.5, 8.0, 9.0, 10.0- and 11.0-mm diameter) were divided into 6 groups containing6 plates of each size and submitted to the 4-point flexion test of resistance, using a piece of dog femur (weights of 5, 10,15, 20 and 25 kg) as the bone in which the...(AU)


Assuntos
Animais , Cães , Titânio/análise , Placas Ósseas/veterinária , Materiais Biocompatíveis , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Próteses e Implantes/veterinária
3.
Acta sci. vet. (Impr.) ; 49: Pub.1791-2021. tab
Artigo em Inglês | VETINDEX | ID: biblio-1458430

Resumo

Background: Extraluminal surgical procedures for intrathoracic tracheal collapse in dogs are not routinely performed. The patients are normally treated with different drugs or by intraluminal stents. However, in more severe cases, drug treatment does not always have good outcomes, and intraluminal prostheses can be correlated to several postoperative problems. In order to obtain better results, we aimed to develop a surgical technique for implantation of a new extraluminal helical prosthesis in the thoracic segment of the trachea through cervical access, associated with pneumatic mediastinoscopy for certification of the technique and minimization of possible complications. Materials, Methods & Results: Seven canine corpses (CCs) from non-traumatic death, weighing between 2 and 7 kg, were used. A ventral cervical approach to the trachea was associated with blunt mediastinal dissection. Trans cervical pneumatic mediastinoscopy was used for evaluation of the dissection and location of the implant. These were compared with the necropsy findings by the exact Wilcoxon two-sample test, with P < 0.05. The results of necropsy and mediastinoscopy did not present significant differences at P < 0.05. During the examinations, the presence of some mediastinal visceral le-sions caused by the prosthesis, the integrity of the mediastinum and possible lesions to RLN and blood vessels (BV) were analyzed. We also investigated the location of the distal part of the prosthesis in the thoracic segment of the trachea and its dissection. To evaluate the technique, statistical comparison was made between mediastinoscopy and necropsy find-ings. The data were compared by the Wilcoxon test at 5% probability. The tracheas of all CCs were efficiently dissected, but in some cases problems that can happen during the procedure were noticed. This was checked by mediastinoscopy and confirmed by necropsy. The median of the scores was...


Assuntos
Animais , Cães , Cães/cirurgia , Stents/veterinária , Traqueia/cirurgia , Procedimentos Cirúrgicos Operatórios/veterinária
4.
Acta sci. vet. (Online) ; 49: Pub. 1791, Mar. 8, 2021. tab
Artigo em Inglês | VETINDEX | ID: vti-761942

Resumo

Background: Extraluminal surgical procedures for intrathoracic tracheal collapse in dogs are not routinely performed. The patients are normally treated with different drugs or by intraluminal stents. However, in more severe cases, drug treatment does not always have good outcomes, and intraluminal prostheses can be correlated to several postoperative problems. In order to obtain better results, we aimed to develop a surgical technique for implantation of a new extraluminal helical prosthesis in the thoracic segment of the trachea through cervical access, associated with pneumatic mediastinoscopy for certification of the technique and minimization of possible complications. Materials, Methods & Results: Seven canine corpses (CCs) from non-traumatic death, weighing between 2 and 7 kg, were used. A ventral cervical approach to the trachea was associated with blunt mediastinal dissection. Trans cervical pneumatic mediastinoscopy was used for evaluation of the dissection and location of the implant. These were compared with the necropsy findings by the exact Wilcoxon two-sample test, with P < 0.05. The results of necropsy and mediastinoscopy did not present significant differences at P < 0.05. During the examinations, the presence of some mediastinal visceral le-sions caused by the prosthesis, the integrity of the mediastinum and possible lesions to RLN and blood vessels (BV) were analyzed. We also investigated the location of the distal part of the prosthesis in the thoracic segment of the trachea and its dissection. To evaluate the technique, statistical comparison was made between mediastinoscopy and necropsy find-ings. The data were compared by the Wilcoxon test at 5% probability. The tracheas of all CCs were efficiently dissected, but in some cases problems that can happen during the procedure were noticed. This was checked by mediastinoscopy and confirmed by necropsy. The median of the scores was...(AU)


Assuntos
Animais , Cães , Cães/cirurgia , Traqueia/cirurgia , Stents/veterinária , Procedimentos Cirúrgicos Operatórios/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA