Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Arq. bras. med. vet. zootec. (Online) ; 74(3): 535-541, May-June 2022. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1383785

Resumo

Vehicle collisions involving giant anteaters contribute significantly to the decline of this population. Although mortality rates at the time of trauma are high, many animals survive despite severe trauma and limb fractures. Treating these individuals is extremely challenging. This report describes the use of a corrective osteotomy to treat an angular deformity caused by inadequate healing of a tibial and fibular fracture in a young giant anteater. The animal was rescued on a highway by the Brazilian Institute for the Environment and Renewable Natural Resources (Ibama). He was presented at the University Veterinary Hospital with lameness of the left pelvic limb and edema in the middle region of the tibial shaft. The radiographic examination showed an exuberant callus and significant bone deviation in the middle third of the left tibia and fibula. Corrective wedge osteotomy and fixation with a 3.5mm locking plate and 2.5mm intramedullary pin were performed. In the immediate postoperative period, there was functional recovery of the limb and complete consolidation of the osteotomy was identified 60 days after the operation. The corrective wedge osteotomy technique was effective for the treatment of inadequate tibial consolidation in a young giant anteater, providing complete recovery of all limb functions.


As colisões de veículos envolvendo tamanduás-bandeira contribuem significativamente para o declínio dessa população. Embora as taxas de mortalidade no momento do trauma sejam altas, muitos animais sobrevivem apesar de traumas graves e fraturas de membros. O tratamento desses indivíduos é extremamente desafiador. Este relato descreve o uso de osteotomia corretiva para tratamento de uma deformidade angular causada por consolidação inadequada de fratura da tíbia e da fíbula em um tamanduá-bandeira jovem. O animal foi resgatado em uma rodovia pelo Instituto Brasileiro do Meio Ambiente e dos Recursos Naturais Renováveis (Ibama). Foi apresentado no Hospital Veterinário Universitário com claudicação do membro pélvico esquerdo e edema na região média da diáfise da tíbia. O exame radiográfico mostrou calo exuberante e importante desvio ósseo em terço médio da tíbia e da fíbula esquerdas. Foi realizada osteotomia corretiva em cunha e fixação com placa bloqueada de 3,5mm e pino intramedular de 2,5mm. No pós-operatório imediato, houve recuperação funcional do membro, e a consolidação total da osteotomia foi identificada aos 60 dias de pós-operatório. A técnica de osteotomia em cunha corretiva foi eficaz para o tratamento de consolidação inadequada de tíbia em um tamanduá-bandeira jovem, proporcionando a recuperação completa de todas as funções do membro.


Assuntos
Animais , Osteotomia , Tíbia , Fraturas Ósseas , Fíbula , Vermilingua
2.
Arq. bras. med. vet. zootec. (Online) ; 72(2): 493-498, Mar./Apr. 2020. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-1128385

Resumo

Foi atendida, no Hospital Veterinário da Universidade de Cuiabá, uma coruja suindara (Tyto furcata), resgatada pela Polícia Militar Ambiental, sem histórico, adulta e 400 gramas de peso corporal. A ave apresentava impotência funcional do membro pélvico direito, além de desvio, crepitação e dor na região proximal tibiotársica direita, sem lesão cutânea. Estudo radiográfico revelou fratura diafisária oblíqua curta em tibiotarso direito. A estabilização da fratura foi realizada com placa bloqueada do sistema de 1,5mm, na função de apoio, seis orifícios, com três parafusos monocorticais distais, dois parafusos monocorticais proximais e um parafuso bicortical proximal. Ao 30º dia do pós-operatório, os achados radiográficos de consolidação óssea e o retorno da função do membro permitiram a alta médica. Concluiu-se que o uso de placa bloqueada em função apoio para estabilização de fraturas tibiotársicas simples de coruja suindara oferece resultados satisfatórios.(AU)


An adult suindara owl (Tyto furcata), with no specific history and 400 grams of body weight was treated at the Veterinary Hospital of the University of Cuiabá. The patient presented functional impotence in the right pelvic limb, deviation, crepitation and pain in the proximal region in right tibiotarsal, without cutaneous lesions. Radiographs revealed a short oblique diaphyseal fracture at the right tibiotarsus. Fracture stabilization was performed with a 1.5mm locking plate, buttress, six holes; three distal monocortical screws, two proximal monocortical screws and a proximal bicortical screw. On the 30th postoperative day, radiographic revealed bone healing, and the return of limb function allowed medical discharge. It was concluded that the use of locking plates in buttress function to stabilize simple tibiotarsus fractures in suindara owl offers satisfactory results.(AU)


Assuntos
Animais , Fraturas da Tíbia/cirurgia , Placas Ósseas/veterinária , Estrigiformes/cirurgia , Fraturas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária
3.
Arq. bras. med. vet. zootec. (Online) ; 72(2): 493-498, Mar./Apr. 2020. ilus
Artigo em Português | VETINDEX | ID: vti-29630

Resumo

Foi atendida, no Hospital Veterinário da Universidade de Cuiabá, uma coruja suindara (Tyto furcata), resgatada pela Polícia Militar Ambiental, sem histórico, adulta e 400 gramas de peso corporal. A ave apresentava impotência funcional do membro pélvico direito, além de desvio, crepitação e dor na região proximal tibiotársica direita, sem lesão cutânea. Estudo radiográfico revelou fratura diafisária oblíqua curta em tibiotarso direito. A estabilização da fratura foi realizada com placa bloqueada do sistema de 1,5mm, na função de apoio, seis orifícios, com três parafusos monocorticais distais, dois parafusos monocorticais proximais e um parafuso bicortical proximal. Ao 30º dia do pós-operatório, os achados radiográficos de consolidação óssea e o retorno da função do membro permitiram a alta médica. Concluiu-se que o uso de placa bloqueada em função apoio para estabilização de fraturas tibiotársicas simples de coruja suindara oferece resultados satisfatórios.(AU)


An adult suindara owl (Tyto furcata), with no specific history and 400 grams of body weight was treated at the Veterinary Hospital of the University of Cuiabá. The patient presented functional impotence in the right pelvic limb, deviation, crepitation and pain in the proximal region in right tibiotarsal, without cutaneous lesions. Radiographs revealed a short oblique diaphyseal fracture at the right tibiotarsus. Fracture stabilization was performed with a 1.5mm locking plate, buttress, six holes; three distal monocortical screws, two proximal monocortical screws and a proximal bicortical screw. On the 30th postoperative day, radiographic revealed bone healing, and the return of limb function allowed medical discharge. It was concluded that the use of locking plates in buttress function to stabilize simple tibiotarsus fractures in suindara owl offers satisfactory results.(AU)


Assuntos
Animais , Fraturas da Tíbia/cirurgia , Placas Ósseas/veterinária , Estrigiformes/cirurgia , Fraturas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária
4.
Arq. bras. med. vet. zootec. (Online) ; 70(1): 117-121, Jan.-Feb. 2018. tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-888081

Resumo

São poucos os dados publicados sobre a aplicabilidade ou a confiabilidade dos métodos digitais para mensuração do ângulo do platô tibial (APT) em comparação à mensuração manual. O objetivo deste estudo foi comparar o APT obtido pelo cálculo manual padrão, em filmes radiográficos, com os valores obtidos por cálculos em imagens digitais, por meio do software do computador. Foram analisadas radiografias digitais do membro pélvico, direito e esquerdo, em perfil verdadeiro, de 20 cães saudáveis, com idade superior a um ano. Três observadores com graus de experiência semelhantes em cálculo do APT realizaram as mensurações em cada radiografia. Primeiramente, foram calculados os ângulos dos platôs tibiais manualmente nas películas radiográficas e, posteriormente, os cálculos foram realizados na imagem digital, por meio do software para medicina veterinária do sistema de raios X digital. Os resultados do presente estudo demonstraram diferenças significativas entre os métodos, com valor das médias do cálculo digital 20,48±3.71 e do cálculo manual 23.90±4.02. Valor de P foi < 0,01 na comparação entre médias dos dois grupos. Na avaliação interobservadores, houve diferença significativa no cálculo manual no perfil direito, o que sugere maior variação no cálculo manual quando comparado ao digital. O cálculo realizado pelo software apresentou menor variação nos valores interobservadores. Acredita-se que a menor variação obtida nos resultados aqui apresentados se dê em razão das facilidades proporcionadas pelo software. Conclui-se que houve diferença entre os valores obtidos por meio dos métodos convencional e digital no cálculo do ângulo do platô tibial, sendo os valores digitais menores entre os observadores, e que o método digital no cálculo do ângulo do platô tibial levou à menor variação quando comparado ao método manual.(AU)


There are few published data on the applicability and reliability of digital methods for measuring the TPA compared with manual measurement. The objective of this study was to compare the TPA obtained by calculating standard manual on conventional radiographs, with the values obtained by calculations in digital images through a computer program. Bilateral digital radiographs of hind limb were analyzed in true profile for 20 healthy dogs older than two years. Three observers with similar levels of experience in calculating the TPA conducted measurements on each radiograph. First we calculated the angle of the tibial plateaus manually in x-ray film and then the calculations were made through the program offered by the computer program in the digital image. The results of this study showed significant differences between the methods, with average value of 20.48±3.71 digital calculating average and 23.90±2.4 in the manual calculation. P value was < 0.01 when comparing averages. No significant difference in manual calculation in right profile were found between interobserver assessments, suggesting greater variation in manual calculation compared to digital. The calculation performed by the software showed less variation in values. The slight variation obtained in our results is believed to be due to the facilities provided by the software. There was a difference between the values obtained by means of conventional and digital methods for calculating the angle of the tibial plateau, and the smaller digital values between the observers and the digital method in the calculation of the tibial plateau angle led to less variation when compared to the manual method.(AU)


Assuntos
Animais , Cães , Estudo Comparativo , Ligamento Cruzado Anterior/anormalidades , Cães/anormalidades , Joelho/anormalidades
5.
Arq. bras. med. vet. zootec. (Online) ; 70(1): 117-121, jan.-fev. 2018. tab
Artigo em Português | VETINDEX | ID: vti-19241

Resumo

São poucos os dados publicados sobre a aplicabilidade ou a confiabilidade dos métodos digitais para mensuração do ângulo do platô tibial (APT) em comparação à mensuração manual. O objetivo deste estudo foi comparar o APT obtido pelo cálculo manual padrão, em filmes radiográficos, com os valores obtidos por cálculos em imagens digitais, por meio do software do computador. Foram analisadas radiografias digitais do membro pélvico, direito e esquerdo, em perfil verdadeiro, de 20 cães saudáveis, com idade superior a um ano. Três observadores com graus de experiência semelhantes em cálculo do APT realizaram as mensurações em cada radiografia. Primeiramente, foram calculados os ângulos dos platôs tibiais manualmente nas películas radiográficas e, posteriormente, os cálculos foram realizados na imagem digital, por meio do software para medicina veterinária do sistema de raios X digital. Os resultados do presente estudo demonstraram diferenças significativas entre os métodos, com valor das médias do cálculo digital 20,48±3.71 e do cálculo manual 23.90±4.02. Valor de P foi < 0,01 na comparação entre médias dos dois grupos. Na avaliação interobservadores, houve diferença significativa no cálculo manual no perfil direito, o que sugere maior variação no cálculo manual quando comparado ao digital. O cálculo realizado pelo software apresentou menor variação nos valores interobservadores. Acredita-se que a menor variação obtida nos resultados aqui apresentados se dê em razão das facilidades proporcionadas pelo software. Conclui-se que houve diferença entre os valores obtidos por meio dos métodos convencional e digital no cálculo do ângulo do platô tibial, sendo os valores digitais menores entre os observadores, e que o método digital no cálculo do ângulo do platô tibial levou à menor variação quando comparado ao método manual.(AU)


There are few published data on the applicability and reliability of digital methods for measuring the TPA compared with manual measurement. The objective of this study was to compare the TPA obtained by calculating standard manual on conventional radiographs, with the values obtained by calculations in digital images through a computer program. Bilateral digital radiographs of hind limb were analyzed in true profile for 20 healthy dogs older than two years. Three observers with similar levels of experience in calculating the TPA conducted measurements on each radiograph. First we calculated the angle of the tibial plateaus manually in x-ray film and then the calculations were made through the program offered by the computer program in the digital image. The results of this study showed significant differences between the methods, with average value of 20.48±3.71 digital calculating average and 23.90±2.4 in the manual calculation. P value was < 0.01 when comparing averages. No significant difference in manual calculation in right profile were found between interobserver assessments, suggesting greater variation in manual calculation compared to digital. The calculation performed by the software showed less variation in values. The slight variation obtained in our results is believed to be due to the facilities provided by the software. There was a difference between the values obtained by means of conventional and digital methods for calculating the angle of the tibial plateau, and the smaller digital values between the observers and the digital method in the calculation of the tibial plateau angle led to less variation when compared to the manual method.(AU)


Assuntos
Animais , Cães , Cães/lesões , Ligamentos/lesões
6.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1456-1460, nov.-dez. 2017. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-910031

Resumo

O objetivo deste trabalho foi demonstrar que o posicionamento radiográfico inadequado do membro pélvico de cães (imagens obliquadas) afeta a mensuração do ângulo do platô tibial (APT), levando à maior variação entre observadores. Foram realizadas duas projeções radiográficas nos membros pélvicos direito e esquerdo, uma em perfil verdadeiro e a outra com o membro obliquado em 21 cães provenientes do atendimento clínico cirúrgico do Hospital Veterinário da Universidade de Cuiabá, em Cuiabá-MT. Os critérios de inclusão foram cães livres de histórico ou afecção ortopédica nos membros pélvicos, pesando entre 15 e 40 quilos, sem predileção por raça ou sexo, entre dois e sete anos de idade. Foram obtidas 42 imagens radiográficas em perfil verdadeiro e 42 imagens radiográficas obliquadas. Três observadores com experiência em cálculo do APT fizeram as mensurações. Nos cálculos das imagens em perfil verdadeiro, o observador 1 obteve uma média de 23,35º ± 2,82; o observador 2, média de 23,88º ± 4,83; e o observador 3, média de 24,54º ± 4,01, não sendo encontrada diferença significativa entre o cálculo dos três avaliadores, P=0,944 (P > 0,05), nas imagens em perfil verdadeiro. Nos cálculos das imagens obliquadas, o observador 1 obteve uma média de 21,69º ± 4,22; o observador 2, média de 19,42º ± 5,92; e o observador 3, média de 22,64º ± 5,23, e foi encontrada diferença significativa entre o cálculo dos três observadores, P=0,016 (P < 0,05). Com esses dados, pôde-se demonstrar que a imagem radiográfica obliquada compromete o valor final do cálculo do ângulo do platô tibial em cães, levando à variação numérica estatisticamente significativa entre observadores. Conclui-se, assim, que um posicionamento correto do membro pélvico, em perfil verdadeiro, deve ser sempre utilizado para a obtenção de imagens, com o objetivo de mensurar o valor do APT.(AU)


This work aimed at demonstrating that an inadequate radiographic position of pelvic limbs of dogs, from a strict lateral radiographic view, resulted in oblique images, affecting the measurement of the tibial plateau angle (TPA). There were two radiographic projections of the right and the left pelvic limb, one in strict lateral radiographic view and another with inclined hind limb in 21 dogs from the clinical surgical assistance at Hospital Veterinário of Universidade de Cuiabá in Cuiabá-MT. Inclusion criteria were dogs free from pelvic hind limbs orthopedic affection records, weighing between 15 and 40 kilos, without a preference for breed or gender and ageing between two and seven years old. A total of 42 radiographic images in strict lateral radiographic view and 42 inclined limb radiographic views were obtained. Three observers with TPA calculation experience made measurements. In the calculus for the strict lateral radiographic view the first observer has reached an average of 23,35º ± 2,82, the second observer 23,88º ± 4,83 and the third observer 24,54º ± 4,01. No significant statistic differences among the calculus of the three evaluators p=0,944 (P>0,05) was found. In the calculus of the inclined limbs radiographic views the first observer reached an average of 21,69º ± 4,22, the second observer 19,42º ± 5,92 and the third observer 22,64º ±. 5,23. Significant statistic difference in the calculus of the three observers, p=0,016, that is to say, P<0,05 was found. The data indicated that the inclined limb radiographic image compromises the final value of the calculation of tibial plateau angle in dogs. Thus, correct positioning of the pelvic limb, in a strict lateral radiographic view, must be always used for obtaining images aiming at measuring the value of TPA.(AU)


Assuntos
Animais , Cães , Ligamentos Articulares/diagnóstico por imagem , Posicionamento do Paciente/veterinária , Pelve/diagnóstico por imagem , Tíbia/anatomia & histologia , Lesões do Ligamento Cruzado Anterior/veterinária , Osteotomia/veterinária
7.
Artigo em Português | VETINDEX | ID: vti-20200

Resumo

ABSTRACT This work aimed at demonstrating that an inadequate radiographic position of pelvic limbs of dogs, from a strict lateral radiographic view, resulted in oblique images, affecting the measurement of the tibial plateau angle (TPA). There were two radiographic projections of the right and the left pelvic limb, one in strict lateral radiographic view and another with inclined hind limb in 21 dogs from the clinical surgical assistance at Hospital Veterinário of Universidade de Cuiabá in Cuiabá-MT. Inclusion criteria were dogs free from pelvic hind limbs orthopedic affection records, weighing between 15 and 40 kilos, without a preference for breed or gender and ageing between two and seven years old. A total of 42 radiographic images in strict lateral radiographic view and 42 inclined limb radiographic views were obtained. Three observers with TPA calculation experience made measurements. In the calculus for the strict lateral radiographic view the first observer has reached an average of 23,35º ± 2,82, the second observer 23,88º ± 4,83 and the third observer 24,54º ± 4,01. No significant statistic differences among the calculus of the three evaluators p=0,944 (P>0,05) was found. In the calculus of the inclined limbs radiographic views the first observer reached an average of 21,69º ± 4,22, the second observer 19,42º ± 5,92 and the third observer 22,64º ±. 5,23. Significant statistic difference in the calculus of the three observers, p=0,016, that is to say, P 0,05 was found. The data indicated that the inclined limb radiographic image compromises the final value of the calculation of tibial plateau angle in dogs. Thus, correct positioning of the pelvic limb, in a strict lateral radiographic view, must be always used for obtaining images aiming at measuring the value of TPA.


RESUMO O objetivo deste trabalho foi demonstrar que o posicionamento radiográfico inadequado do membro pélvico de cães (imagens obliquadas) afeta a mensuração do ângulo do platô tibial (APT), levando à maior variação entre observadores. Foram realizadas duas projeções radiográficas nos membros pélvicos direito e esquerdo, uma em perfil verdadeiro e a outra com o membro obliquado em 21 cães provenientes do atendimento clínico cirúrgico do Hospital Veterinário da Universidade de Cuiabá, em Cuiabá-MT. Os critérios de inclusão foram cães livres de histórico ou afecção ortopédica nos membros pélvicos, pesando entre 15 e 40 quilos, sem predileção por raça ou sexo, entre dois e sete anos de idade. Foram obtidas 42 imagens radiográficas em perfil verdadeiro e 42 imagens radiográficas obliquadas. Três observadores com experiência em cálculo do APT fizeram as mensurações. Nos cálculos das imagens em perfil verdadeiro, o observador 1 obteve uma média de 23,35º ± 2,82; o observador 2, média de 23,88º ± 4,83; e o observador 3, média de 24,54º ± 4,01, não sendo encontrada diferença significativa entre o cálculo dos três avaliadores, P=0,944 (P > 0,05), nas imagens em perfil verdadeiro. Nos cálculos das imagens obliquadas, o observador 1 obteve uma média de 21,69º ± 4,22; o observador 2, média de 19,42º ± 5,92; e o observador 3, média de 22,64º ± 5,23, e foi encontrada diferença significativa entre o cálculo dos três observadores, P=0,016 (P 0,05). Com esses dados, pôde-se demonstrar que a imagem radiográfica obliquada compromete o valor final do cálculo do ângulo do platô tibial em cães, levando à variação numérica estatisticamente significativa entre observadores. Conclui-se, assim, que um posicionamento correto do membro pélvico, em perfil verdadeiro, deve ser sempre utilizado para a obtenção de imagens, com o objetivo de mensurar o valor do APT.

8.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1456-1460, Nov.-Dez. 2017. ilus
Artigo em Português | VETINDEX | ID: vti-735017

Resumo

O objetivo deste trabalho foi demonstrar que o posicionamento radiográfico inadequado do membro pélvico de cães (imagens obliquadas) afeta a mensuração do ângulo do platô tibial (APT), levando à maior variação entre observadores. Foram realizadas duas projeções radiográficas nos membros pélvicos direito e esquerdo, uma em perfil verdadeiro e a outra com o membro obliquado em 21 cães provenientes do atendimento clínico cirúrgico do Hospital Veterinário da Universidade de Cuiabá, em Cuiabá-MT. Os critérios de inclusão foram cães livres de histórico ou afecção ortopédica nos membros pélvicos, pesando entre 15 e 40 quilos, sem predileção por raça ou sexo, entre dois e sete anos de idade. Foram obtidas 42 imagens radiográficas em perfil verdadeiro e 42 imagens radiográficas obliquadas. Três observadores com experiência em cálculo do APT fizeram as mensurações. Nos cálculos das imagens em perfil verdadeiro, o observador 1 obteve uma média de 23,35º ± 2,82; o observador 2, média de 23,88º ± 4,83; e o observador 3, média de 24,54º ± 4,01, não sendo encontrada diferença significativa entre o cálculo dos três avaliadores, P=0,944 (P > 0,05), nas imagens em perfil verdadeiro. Nos cálculos das imagens obliquadas, o observador 1 obteve uma média de 21,69º ± 4,22; o observador 2, média de 19,42º ± 5,92; e o observador 3, média de 22,64º ± 5,23, e foi encontrada diferença significativa entre o cálculo dos três observadores, P=0,016 (P < 0,05). Com esses dados, pôde-se demonstrar que a imagem radiográfica obliquada compromete o valor final do cálculo do ângulo do platô tibial em cães, levando à variação numérica estatisticamente significativa entre observadores. Conclui-se, assim, que um posicionamento correto do membro pélvico, em perfil verdadeiro, deve ser sempre utilizado para a obtenção de imagens, com o objetivo de mensurar o valor do APT.(AU)


This work aimed at demonstrating that an inadequate radiographic position of pelvic limbs of dogs, from a strict lateral radiographic view, resulted in oblique images, affecting the measurement of the tibial plateau angle (TPA). There were two radiographic projections of the right and the left pelvic limb, one in strict lateral radiographic view and another with inclined hind limb in 21 dogs from the clinical surgical assistance at Hospital Veterinário of Universidade de Cuiabá in Cuiabá-MT. Inclusion criteria were dogs free from pelvic hind limbs orthopedic affection records, weighing between 15 and 40 kilos, without a preference for breed or gender and ageing between two and seven years old. A total of 42 radiographic images in strict lateral radiographic view and 42 inclined limb radiographic views were obtained. Three observers with TPA calculation experience made measurements. In the calculus for the strict lateral radiographic view the first observer has reached an average of 23,35º ± 2,82, the second observer 23,88º ± 4,83 and the third observer 24,54º ± 4,01. No significant statistic differences among the calculus of the three evaluators p=0,944 (P>0,05) was found. In the calculus of the inclined limbs radiographic views the first observer reached an average of 21,69º ± 4,22, the second observer 19,42º ± 5,92 and the third observer 22,64º ±. 5,23. Significant statistic difference in the calculus of the three observers, p=0,016, that is to say, P<0,05 was found. The data indicated that the inclined limb radiographic image compromises the final value of the calculation of tibial plateau angle in dogs. Thus, correct positioning of the pelvic limb, in a strict lateral radiographic view, must be always used for obtaining images aiming at measuring the value of TPA.(AU)


Assuntos
Animais , Cães , Ligamentos Articulares/diagnóstico por imagem , Posicionamento do Paciente/veterinária , Pelve/diagnóstico por imagem , Tíbia/anatomia & histologia , Lesões do Ligamento Cruzado Anterior/veterinária , Osteotomia/veterinária
9.
Arq. bras. med. vet. zootec ; 66(1): 27-33, fev. 2014. ilus
Artigo em Português | VETINDEX | ID: vti-10320

Resumo

Avaliaram-se 12 feridas granulomatosas em membros torácicos e pélvicos de equinos da raça Pantaneira. Foi realizado diagnóstico sugestivo para pitiose cutânea de acordo com as características clínicas das feridas e avaliação histopatológica, com as colorações de hematoxilina-eosina (HE) e Prata Metenamina de Grocott (GMS). A confirmação do diagnóstico foi realizada por exame imuno-histoquímico, método streptavidina-biotina marcada (LSAB). O diagnóstico histopatológico foi de dermatite piogranulomatosa, focal extensa, acentuada, associada a "pseudo-hifas" características de Pythium insidiosum (pitiose cutânea), nos 12 animais desta pesquisa. O diagnóstico de pitiose foi confirmado em 100% dos casos pela imunomarcação positiva (LSAB) para Pythium insidiosum, caracterizada pela visualização de estruturas ramificadas e septadas, sendo observados 100% de paridade entre as técnicas. É possível concluir que a caracterização clínica das feridas granulomatosas com aspecto de pitiose em equinos associada ao resultado histopatológico sugestivo para pitiose equina constituem métodos de diagnóstico confiáveis, os quais podem ser confirmados pela técnica de imuno-histoquímica.(AU)


Twelve granulomatous lesions in the thoracic and pelvic limbs of horses from pantaneira breed were evaluated. It was performed suggestive diagnostic of cutaneous pythiosis according to the clinic characteristics of the lesions and histopathological exams using hematoxylin and eosin (HE) and Grocott's methenamine silver (GMS) stains. The confirmation of the diagnoses was performed by the labelled streptavidin biotin (LSAB) method (immunohistochemistry). Extensive focal pyogranulomatous dermatitis associated with "pseudo hyphae" characteristic of Pythium insidiosum (subcutaneous pythiosis) was the histopathological diagnosis for all 12 horses used in this study. It was confirmed in 100% of the cases by the positive result to Pythium insidiosum in the immunohistochemistry exam, characterized by the visualization of branched and septated structures. It was observed 100% of parity between the techniques. We can conclude that clinical characterization of the granulomatous lesions with pythiosis aspects in horses associated with histopathology suggestive of equine pythiosis constitute a reliable method of diagnostic that can be confirmed by immunohistochemistry technique.(AU)


Assuntos
Animais , Pitiose/patologia , Dermatite/patologia , Cavalos/classificação
10.
Arq. bras. med. vet. zootec ; 65(4): 975-980, ago. 2013. tab
Artigo em Português | VETINDEX | ID: vti-9796

Resumo

Objetivou-se avaliar o efeito da ingestão de gossipol livre sobre a qualidade espermática e a morfologia dos testículos e dos epidídimos de touros da raça Nelore. Doze touros receberam dieta contendo 3,3g de gossipol livre/touro/dia (caroço de algodão) (Grupo 1, n=6) e dieta isenta de gossipol (Grupo 2, n=6), respectivamente. Foram realizadas coletas de sêmen no início e no final do experimento, que teve duração de 73 dias. Ao final do estudo, foram retirados os testículos e os epidídimos dos touros para se estudar o efeito do gossipol livre sobre as características histológicas. O consumo médio de 3,3g de gossipol livre/touro/dia (média 7,1mg de gossipol livre/kg/dia) reduziu a motilidade e a concentração espermática e aumentou a porcentagem de defeitos espermáticos maiores e totais. Além disso, os animais apresentaram testículos com túbulos seminíferos de menor espessura de parede, menor número de camadas de células espermatogênicas, menor espessura do epitélio epididimário e menor número de espermatozoide no interior dos ductos epidídimários, em relação aos animais com dieta isenta de gossipol (Grupo 2). O consumo de 3,3g de gossipol livre/touro/dia acarretou alterações na morfologia e na morfometria dos testículos e dos epidídimos e reduziu a qualidade espermática dos touros.(AU)


The objective was to evaluate the effect of intake of free gossypol on sperm quality and morphology of the testicles and epididymis of Nelore bulls. Twelve bulls were fed diets containing 3.3g of free gossypol/bull/day (cottonseed) (Group 1, n = 6) and a diet free of gossypol (Group 2, n = 6), respectively. Semen samples were collected in the beginning and end of the experiment which lasted 73 days. In the end of the study the testes and epididymis of bulls were removed to study the effect of free gossypol on histological characteristics. The average consumption of 3.3g of free gossypol/bull/day (mean 7.1mg of free gossypol/kg/day) reduced motility and sperm concentration and increased the percentage of major and total sperm defects, as well as the animals showing testes with seminiferous tubules of smaller thickness, fewer layers of spermatogenic lineage cells, smaller epididymal epithelium thickness and smaller number of sperm within the epididymal ducts, compared to animals with a diet free of gossypol (Group 2). The consumption of 3.3g of free gossypol/bull/day led to changes in morphology and morphometry of the testes and epididymis and reduced sperm quality of bulls.(AU)


Assuntos
Animais , Análise do Sêmen , Testículo/anatomia & histologia , Dieta , Gossipol , Bovinos/classificação
11.
Arq. bras. med. vet. zootec ; 64(6): 1547-1554, 2012. ilus
Artigo em Português | VETINDEX | ID: vti-10899

Resumo

Foi realizada falha segmentar de 6mm na região metafisária medial da tíbia de 12 coelhos, seguida de preenchimento desta por matriz óssea mineralizada heteróloga fragmentada conservada em glicerina (98%) e metilmetacrilato autoclavado, bem como avaliação por meio da tomografia computadorizada de feixe cônico (cone beam) aos 30, 60 e 90 dias. Houve incorporação gradativa do implante no leito receptor em relação ao tempo em 100% dos casos, o que mostra ser este biologicamente compatível, ao promover reparação da falha óssea, sem sinais de infecção, migração e/ou rejeição, caracterizando-se, assim, como nova opção de substituto ósseo para preenchimento de falhas ósseas.(AU)


A 6mm segmental defect was performed on the metaphyseal region of the tibia of 12 rabbits and the autoclaved fragmented heterolog cortical bone conserved in glycerin (98%) and methylmethacrylate was used as a bone graft for the reconstruction. The graft was placed in the receptor bed and its integration was evaluated by computed tomography after 30, 60 and 90 days. There was gradual bone graft incorporation in the receptor bed during the time in 100% of the cases. Fragmented cortical bone heterograft and methylmethacrylate was biologically compatible and promotes bone defect reparation without signs of infection, migration and or rejection, featuring a new option of osseous substitute to fill in bone defects.(AU)


Assuntos
Animais , Coelhos , Matriz Óssea , Metilmetacrilato , Tíbia/anormalidades , Tomografia Computadorizada de Feixe Cônico/veterinária , Tomografia Computadorizada por Raios X , Osso e Ossos/anormalidades
12.
Arq. bras. med. vet. zootec ; 62(3): 639-644, jun. 2010. ilus
Artigo em Português | VETINDEX | ID: vti-5856

Resumo

Estudou-se a viabilidade do autotransplante de tecido esplênico, um terço do baço, associado à esplenectomia parcial, e verificou-se a cinética evolutiva de sua regeneração, sob o aspecto macroscópico e histológico. Foram utilizados 28 ratos Wistar, adultos, machos, com média de peso de 300g, distribuídos em quatro grupos experimentais. Cada animal foi submetido à esplenectomia parcial, e um fragmento de baço foi transplantado para o omento maior, por períodos de 30, 60, 90 e 120 dias. Após cada período pré-estipulado, os tecidos esplênicos autotransplantados foram coletados e analisados histologicamente. Os resultados mostraram regeneração da cápsula esplênica, dos vasos sanguíneos e das polpas branca e vermelha. Aos 90 dias, a arquitetura microscópica apresentava-se semelhante à do baço normal.(AU)


The splenic tissue autograft viability (one third of the spleen) associated to parcial splenectomy was studied to verify the evolutive kinetic of its regeneration by macroscopic and histological aspects. Twenty-eight adult male Wistar rats, weighting 300g, were distributed in four experimental groups. Each animal was submitted to parcial splenectomy and one fragment of each spleen was autotransplanted to the greater omentum, for a period of 30, 60, 90, and 120 days. After each period, the autotransplanted splenic tissues were collected and histopathologically analyzed. The results showed regeneration of the splenic capsule, blood vessels, white pulp, and red pulp. After 90 days, the microscopic architecture was similar to the normal spleen.(AU)


Assuntos
Animais , Masculino , Adulto , Ratos , Ratos Wistar , Baço/transplante , Regeneração , Esplenectomia/veterinária , Baço/anatomia & histologia
13.
Arq. bras. med. vet. zootec ; 61(6): 1314-1321, dez. 2009. ilus, tab
Artigo em Português | VETINDEX | ID: vti-6159

Resumo

Avaliaram-se as alterações morfológicas, morfométricas e ultraestruturais que ocorreram no baço devido à isquemia produzida pelo clampeamento total do pedículo hepático. Para tanto, foram utilizados 40 ratos machos, distribuídos em quatro grupos de 10 animais. O grupo-controle (C) não foi submetido à isquemia, e os grupos tratados (E1, E2e E3) foram submetidos ao clampeamento por 10, 20 e 30 minutos, respectivamente. Fragmentos do baço foram retirados e analisados histologicamente pela microscopia de luz (hematoxilina-eosina, ferrocianeto-férrico) e pela microscopia eletrônica de transmissão. Os resultados demonstraram que 10 minutos de clampeamento do pedículo hepático são suficientes para apresentar sinais de congestão esplênica e 20 e 30 minutos promovem intensa digestão de hemácias pelos macrófagos, com presença de grânulos de ferro (hemossiderina) no parênquima esplênico.(AU)


The macro and microscopic alterations that occurred in the spleen during an ischemia produced by the hepatic pedicle total clamping were studied. Forty male rats were distributed in four groups of 10 animals each. The control group (C) was not submitted to ischemia and the treated groups (E1, E2, and E3) were submitted to the clamping during 10, 20, and 30 minutes, respectively. Spleen fragments were collected and histologically analyzed by the light microscopy (eosin-hematoxilin and ferric ferrocyanide) and by the transmission electron microscopy. The results showed that 10 minutes of hepatic pedicle total clamping was enough produce signs of splenic congestion and 20 and 30 minutes promoted intense red bood cels digestion by the macrophages with the presence of iron granules (hemosiderin) in the splenic parenchyma.(AU)


Assuntos
Animais , Ratos , Baço/anatomia & histologia , Isquemia/induzido quimicamente , Hemossiderina , Baço/irrigação sanguínea , Ruptura Esplênica/induzido quimicamente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA