Resumo
This study aims to describe the first Brazilian report of a nictitating membrane cyst's surgical treatment in a dog. A 6-month-old female French Bulldog presented at HOSVET-UNIME with a reddish mass-like structure in the medial canthus of both eyes, with a history of recurrent third eyelid gland prolapse previously treated with two surgeries performed at another clinic. Physical examination revealed a third eyelid gland prolapse in the right eye and a cyst in the left eye's third eyelid. The animal was submitted to surgical correction of the right eye's third eyelid prolapse using pocket technique and of the left eye's third eyelid using marsupialization technique for the cyst's treatment. 180 days after th1e surgical procedure no recurrence was observed. The marsupialization technique for the treatment of a third eyelid's lacrimal cyst in a dog allowed the maintenance of its gland and prevented the formation of a new cystic cavity.(AU)
O objetivo do presente trabalho é descrever o primeiro relato no Brasil de tratamento cirúrgico de um cisto da membrana nictitante em um cão. Um Buldogue Francês, fêmea, seis meses, foi atendido no Hosvet-Unime, com queixa de aumento de volume avermelhado no canto medial de ambos os olhos, com histórico de recidiva de prolapso de glândula da terceira pálpebra, onde haviam sido realizadas duas cirurgias anteriormente em outro local. Ao exame físico, foi observado prolapso de glândula da terceira pálpebra no olho direito e a presença de um cisto na terceira pálpebra do olho esquerdo. O animal foi submetido ao procedimento cirúrgico de sepultamento de glândula da terceira pálpebra no olho direito e uma marsupialização na terceira pálpebra do olho esquerdo para o tratamento do cisto. Cento e oitenta dias após o procedimento cirúrgico, não foi observada recidiva. A técnica de marsupialização para tratamento de cisto lacrimal na terceira pálpebra em um cão possibilitou a manutenção da sua glândula e impediu a formação de nova cavidade cística.(AU)
Assuntos
Animais , Feminino , Cães , Cistos/veterinária , Aparelho Lacrimal/cirurgia , Membrana Nictitante/cirurgia , Prolapso , Procedimentos Cirúrgicos Operatórios/veterináriaResumo
This study aims to describe the first Brazilian report of a nictitating membrane cyst's surgical treatment in a dog. A 6-month-old female French Bulldog presented at HOSVET-UNIME with a reddish mass-like structure in the medial canthus of both eyes, with a history of recurrent third eyelid gland prolapse previously treated with two surgeries performed at another clinic. Physical examination revealed a third eyelid gland prolapse in the right eye and a cyst in the left eye's third eyelid. The animal was submitted to surgical correction of the right eye's third eyelid prolapse using pocket technique and of the left eye's third eyelid using marsupialization technique for the cyst's treatment. 180 days after th1e surgical procedure no recurrence was observed. The marsupialization technique for the treatment of a third eyelid's lacrimal cyst in a dog allowed the maintenance of its gland and prevented the formation of a new cystic cavity.(AU)
O objetivo do presente trabalho é descrever o primeiro relato no Brasil de tratamento cirúrgico de um cisto da membrana nictitante em um cão. Um Buldogue Francês, fêmea, seis meses, foi atendido no Hosvet-Unime, com queixa de aumento de volume avermelhado no canto medial de ambos os olhos, com histórico de recidiva de prolapso de glândula da terceira pálpebra, onde haviam sido realizadas duas cirurgias anteriormente em outro local. Ao exame físico, foi observado prolapso de glândula da terceira pálpebra no olho direito e a presença de um cisto na terceira pálpebra do olho esquerdo. O animal foi submetido ao procedimento cirúrgico de sepultamento de glândula da terceira pálpebra no olho direito e uma marsupialização na terceira pálpebra do olho esquerdo para o tratamento do cisto. Cento e oitenta dias após o procedimento cirúrgico, não foi observada recidiva. A técnica de marsupialização para tratamento de cisto lacrimal na terceira pálpebra em um cão possibilitou a manutenção da sua glândula e impediu a formação de nova cavidade cística.(AU)
Assuntos
Animais , Feminino , Cães , Cistos/veterinária , Aparelho Lacrimal/cirurgia , Membrana Nictitante/cirurgia , Prolapso , Procedimentos Cirúrgicos Operatórios/veterináriaResumo
The purpose of this study was to evaluate acrylonitrile butadiene styrene (ABS) and polyamide implants in rabbits submitted to evisceration at the macroscopic and microstructure level and to assess clinical response and histopathological changes as well. For the experimental study implants of 12mm diameter were prepared by rapid prototyping, weighed and the outer and inner surfaces evaluated macroscopically and by electron microscopy. In addition, a compression test was performed and ultrastructural damage was then determined. After evisceration of the left eyeball, nine New Zealand rabbits received ABS implants and nine others received polyamide implants. The animals were assessed daily for 15 days after surgery and every seven days until the end of the study (90 days). Histopathological evaluation was performed at 15, 45 and 90 days after surgery. The ABS implants weighed approximately 0.44g, while the polyamide ones weighed 0.61g. Scanning electron microscopy demonstrated that the ABS implants had regular-sized, equidistant micropores, while the polyamide ones showed micropores of various sizes. The force required to fracture the ABS implant was 14.39 ±0.60 Mpa, while for the polyamide one, it was 16.80 ±1.05 Mpa. Fifteen days after surgery, we observed centripetal tissue infiltration and scarce inflammatory infiltrate. Implants may be used in the filling of anophthalmic cavities, because they are inert, biocompatible and allow tissue integration.(AU)
Avaliou-se a macroscopia, a microestrutura, a resposta clínica e histopatológica de implantes de acrilonitrila butadieno estireno (ABS) e poliamida em coelhos submetidos à evisceração. Para o estudo experimental, os implantes foram elaborados por meio de prototipagem rápida, com 12mm de diâmetro, pesados e tiveram suas superfícies avaliadas macroscopicamente e por microscopia eletrônica de varredura. Adicionalmente, foi realizado ensaio de compressão para determinar a força necessária para fraturar os implantes. Após a evisceração do olho esquerdo, nove coelhos da raça Nova Zelândia receberam implantes de poliamida e nove outros receberam implantes de ABS. Os animais foram avaliados diariamente nos primeiros 15 dias após a cirurgia e a cada sete dias até o fim do período experimental (90 dias). Avaliação histopatológica foi realizada aos 15, 45 e 90 dias após a cirurgia. Os implantes de ABS pesaram 0,44g, e os de poliamida 0,61g. A microscopia eletrônica de varredura demonstrou que os implantes de ABS eram formados por microporos equidistantes, enquanto os de poliamida apresentavam microporos de vários tamanhos. A força necessária para fraturar os implantes de ABS foi de 14.39±0.60 Mpa, enquanto para os de poliamida foi de 16.80±1.05Mpa. Quinze dias após a cirurgia, foi observada infiltração fibrovascular centrípeta. Os implantes podem ser utilizados para correção de cavidades anoftálmicas por se mostrarem inertes, biocompatíveis e permitirem a infiltração tecidual.(AU)
Assuntos
Animais , Coelhos , Materiais Biocompatíveis/análise , Evisceração do Olho/veterinária , Olho Artificial/veterinária , Polímeros , Acrilonitrila/análise , Butadienos/análise , Microscopia Eletrônica de Varredura/veterinária , NylonsResumo
The purpose of this study was to evaluate acrylonitrile butadiene styrene (ABS) and polyamide implants in rabbits submitted to evisceration at the macroscopic and microstructure level and to assess clinical response and histopathological changes as well. For the experimental study implants of 12mm diameter were prepared by rapid prototyping, weighed and the outer and inner surfaces evaluated macroscopically and by electron microscopy. In addition, a compression test was performed and ultrastructural damage was then determined. After evisceration of the left eyeball, nine New Zealand rabbits received ABS implants and nine others received polyamide implants. The animals were assessed daily for 15 days after surgery and every seven days until the end of the study (90 days). Histopathological evaluation was performed at 15, 45 and 90 days after surgery. The ABS implants weighed approximately 0.44g, while the polyamide ones weighed 0.61g. Scanning electron microscopy demonstrated that the ABS implants had regular-sized, equidistant micropores, while the polyamide ones showed micropores of various sizes. The force required to fracture the ABS implant was 14.39 ±0.60 Mpa, while for the polyamide one, it was 16.80 ±1.05 Mpa. Fifteen days after surgery, we observed centripetal tissue infiltration and scarce inflammatory infiltrate. Implants may be used in the filling of anophthalmic cavities, because they are inert, biocompatible and allow tissue integration.(AU)
Avaliou-se a macroscopia, a microestrutura, a resposta clínica e histopatológica de implantes de acrilonitrila butadieno estireno (ABS) e poliamida em coelhos submetidos à evisceração. Para o estudo experimental, os implantes foram elaborados por meio de prototipagem rápida, com 12mm de diâmetro, pesados e tiveram suas superfícies avaliadas macroscopicamente e por microscopia eletrônica de varredura. Adicionalmente, foi realizado ensaio de compressão para determinar a força necessária para fraturar os implantes. Após a evisceração do olho esquerdo, nove coelhos da raça Nova Zelândia receberam implantes de poliamida e nove outros receberam implantes de ABS. Os animais foram avaliados diariamente nos primeiros 15 dias após a cirurgia e a cada sete dias até o fim do período experimental (90 dias). Avaliação histopatológica foi realizada aos 15, 45 e 90 dias após a cirurgia. Os implantes de ABS pesaram 0,44g, e os de poliamida 0,61g. A microscopia eletrônica de varredura demonstrou que os implantes de ABS eram formados por microporos equidistantes, enquanto os de poliamida apresentavam microporos de vários tamanhos. A força necessária para fraturar os implantes de ABS foi de 14.39±0.60 Mpa, enquanto para os de poliamida foi de 16.80±1.05Mpa. Quinze dias após a cirurgia, foi observada infiltração fibrovascular centrípeta. Os implantes podem ser utilizados para correção de cavidades anoftálmicas por se mostrarem inertes, biocompatíveis e permitirem a infiltração tecidual.(AU)
Assuntos
Animais , Coelhos , Evisceração do Olho/veterinária , Olho Artificial/veterinária , Polímeros , Materiais Biocompatíveis/análise , Acrilonitrila/análise , Butadienos/análise , Microscopia Eletrônica de Varredura/veterinária , NylonsResumo
The purpose of this study was to evaluate the macroscopy and microstructure of a double setting alpha-tricalcium phosphate bone cement sphere provided with interconnection channels (alpha-TCP-i), as well as the integration of the implant with the rabbits' orbital tissue, through macroscopic analysis and histopathology. The external and internal surfaces of the alpha-TCP-i were evaluated macroscopically and by electron microscopy. Twelve New Zealand rabbits received 12mm implants of alpha-TCP-i following enucleation of the left eye. The clinical assessment was undertaken daily during the first 15 days, followed by fortnightly assessment until the end of the study period. For the morphological analysis, exenteration was performed in 3 animals per experimental period (15, 45, 90 and 180 days). The external and internal surfaces of the implant appeared solid, smooth and compact, with six channels which interconnected centrally. The micro-architecture was characterized by the formation of columns of hexagonal crystals. No signs of infection, exposure, dehiscence of sutures or extrusion of the implant were noted in any of the animals during the entire period of the study. The morphological evaluation demonstrated the presence of a thin capsule around the implant, from whence appeared fibro-vascular projections, which penetrated it through the interconnecting channels. In the first days after the insertion of the implant, an intense inflammatory reaction was noted. At 180 days, however, there were no signs of inflammation. The alpha-tricalcium phosphate cement implant was well tolerated in this rabbit model and appeared to be relatively inert with some fibrovascular ingrowth through the large channels.(AU)
Avaliaram-se a macroscopia e a microestrutura de esferas compostas por cimento ósseo de alfa-fosfato tricálcico de dupla pega munido de canais de interconexão (alfa-TCP-i) e a integração do implante ao tecido orbital de coelhos através de análise macroscópica e histopatológica. A superfície interna e externa do alfa-TCP-i foi avaliada macroscopicamente e por microscopia eletrônica. Após enucleação do bulbo ocular esquerdo, 12 coelhos da raça Nova Zelândia receberam implantes do alfa-TCP-i com 12mm de diâmetro. A avaliação clínica foi realizada diariamente nos primeiros 15 dias e depois a cada quinze dias até o fim do período de estudo. Para análise morfológica, seguiu-se a exenteração de três animais por período experimental (15, 45, 90 e 180 dias). As superfícies externa e interna do implante mostraram-se compactas, sólidas e lisas, com seis canais que se interconectavam centralmente. A microarquitetura caracterizou-se pela formação de colunas de cristais hexagonais. Sinais de infecção, exposição, deiscência de sutura ou extrusão não foram notados em nenhum dos animais durante o período de estudo. A análise morfológica revelou a presença de fina cápsula ao redor do implante de onde surgiram projeções fibrovasculares que o penetraram através dos canais de interconexão. Nos primeiros dias após a inserção das esferas, notou-se intensa reação inflamatória que se mostrou ausente aos 180 dias. O implante do cimento de alfa-fosfato tricálcico foi bem tolerado em coelhos, mostrou-se relativamente inerte e permitiu a infiltração de tecido fibrovascular através dos canais de interconexão.(AU)
Assuntos
Animais , Coelhos , Anormalidades do Olho/diagnóstico , Anormalidades do Olho/reabilitação , Próteses e ImplantesResumo
Avaliaram-se as ventilações mecânica controlada a volume e espontânea, por meio das variáveis hemogasométricas, cardiovasculares e ventilométricas. Distribuíram-se 28 coelhos nos grupos: GIVC (isofluorano e ventilação controlada a volume), GIVE (isofluorano e ventilação espontânea), GSVC (sevofluorano e ventilação controlada a volume) e GSVE (sevofluorano e ventilação espontânea). Induziu-se por máscara, com isofluorano (GIVE e GIVC) ou sevofluorano (GSVE e GSVC) a 1,5 CAM, em oxigênio a 100%. Para manutenção anestésica, reajustou-se para 1 CAM. No GIVC e no GSVC, administrou-se rocurônio, na dose de 0,6mg/kg, seguida de infusão contínua na mesma dose de 0,6mg/kg/h. No GIVE e no GSVE, foi administrado NaCl 0,9% em vez de rocurônio. Iniciou-se a ventilação controlada ajustando-a de maneira a obter capnometria entre 35 e 45mmHg. Mensuraram-se os parâmetros 60 minutos após a indução anestésica (M0), 15 minutos após o bolus de rocurônio ou NaCl 0,9% (M15) e a cada 15 minutos (M30, M45 e M60). Evidenciou-se hipercapnia e acidose em GIVC, GSVC e GSVE. Concluiu-se que a ventilação mecânica controlada a volume não foi capaz de manter a normocapnia em coelhos, gerando acidose, principalmente quando se utilizou sevofluorano. O uso do isofluorano demonstrou maior estabilidade anestésica que o sevofluorano nesta.(AU)
The volume-controlled mechanical ventilation and spontaneous ventilation, through haemogasometric, cardiovascular and spirometry variables were evaluated. Twenty-eight rabbits were distributed into two groups: GIVC (isoflurane and volume-controlled ventilation), GIVE (isoflurane and spontaneous ventilation), GSVC (sevoflurane and volume-controlled ventilation) and GSVE (sevoflurane and spontaneous ventilation). Induction was performed by mask with isoflurane (GIVE and GIVC) or sevoflurane (GSVE and GSVC) at 1.5 MAC in 100% oxygen. To maintain anesthesia, MAC was reset to 1. In GIVC and GSVC groups, rocuronium was administered at a dose of 0.6 mg/kg followed by its continuous infusion (0.6 mg/kg/h). In GSVE and GIVE, 0.9% NaCl was administered instead of rocuronium. Controlled ventilation was started by adjusting the capnometry in order to obtain values between 35 and 45 mmHg. Parameters were measured 60 minutes after induction of anesthesia (M0), 15 minutes after the bolus of rocuronium or 0.9% NaCl (M15) and every fifteen minutes (M30, M45 and M60). Hypercapnia and acidosis was evident in GIVC, GSVC and GSVE. We concluded that the volume-controlled mechanical ventilation was not able to maintain normocapnia in rabbits, producing acidosis in them, especially when using sevoflurane. The use of isoflurane showed greater stability than the sevoflurane anesthetic in the species studied.(AU)