Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Pesqui. vet. bras ; 32(9): 941-946, set. 2012. ilus, graf
Artigo em Português | VETINDEX | ID: vti-3676

Resumo

The morphometry and haemodynamic aspects of portal vein were studied in 20 normal dogs with less than 120 days of age and in 14 dogs presenting portosystemic shunting with ages between 90 and 360 days. In the control group the hepatic margins were seen 1.50cm to 3.00cm caudal to the costal margin. Collected data indicated that the mean diameter of portal vein (VP), caudal vena cava (VCC) and abdominal aorta (AO) measured respectively, 0.38cm, 0.37cm and 0.41cm. The VP/VCC and VP/AO mean ratios were respectively, 1.10 and 0.94. The average of VP, VCC and AO areas were respectively, 0.12cm², 0.11cm² and 0.14cm². The haemodynamic of portal vein was studied by ultrasound Doppler and the mean velocity of portal blood flow (VMFSP) measured was 17.76cm/s. It was verified that portal blood flow (FSP) average was 83.11ml/min/kg and the congestion index (IC) average was 0.006. In the group of animals presenting portosystemic shunting, the hepatic margins were seen 1.00cm to 2.00cm cranial to the costal margin. The morphometry of VP, VCC and AO presented a mean diameter of 0.40cm, 0.74cm and 0.56cm, respectively. The VP/VCC and VP/AO mean ratios were respectively, 0.54 and 0.69. The average of VP, VCC and AO areas were respectively, 0.14cm², 0.31cm² and 0.25cm². The haemodynamic study demonstrated that the VMFSP measured was 22.29cm/s and the IC average was 0.006.(AU)


Foram realizados o estudo morfométrico e o estudo hemodinâmico da veia porta em vinte cães clinicamente normais, de idade igual e inferior a 120 dias e em quatorze cães portadores de shunt portossistêmico, de idades entre 90 e 360 dias. Nos cães do grupo controle, as margens hepáticas apresentaram-se entre 1,50cm e 3,00cm caudalmente à margem costal. Os diâmetros médios da veia porta (VP), veia cava caudal (VCC) e aorta abdominal (AO) obtidas foram respectivamente, 0,38cm, 0,37cm e 0,41cm. As proporções entre os diâmetros médios VP/VCC e VP/AO apresentaram médias de 1,10 e 0,94, respectivamente. As médias das áreas da VP, VCC e AO resultaram respectivamente em 0,12cm² , 0,11cm² e 0,14cm². No estudo hemodinâmico da VP destes animais, utilizando-se o ultrassom Doppler, a velocidade média de fluxo sangüíneo portal (VMFSP) mediu 17,76cm/s. A média de fluxo sangüíneo portal (FSP) resultou em 83,11ml/min/kg. O índice de congestão (IC) apresentou média de 0,006. Para o grupo de cães portadores de shunt portossistêmico, o fígado apresentou redução de seu volume, sendo as margens hepáticas visibilizadas entre 1,00cm e 2,00cm cranialmente à margem costal. No estudo morfométrico, as médias dos diâmetros médios obtidos de VP, VCC e AO resultaram respectivamente em 0,40cm, 0,74cm e 0,56cm. As proporções entre os diâmetros médios VP/VCC e VP/AO resultaram respectivamente em 0,54 e 0,69. As médias das áreas de VP, VCC e AO resultaram respectivamente em 0,14cm², 0,31cm² e 0,25cm². Ao ultrassom Doppler a VMFSP mediu 22,29cm/s e a média do IC da VP obtido foi de 0,006.(AU)


Assuntos
Animais , Cães , Cães/anormalidades , Veia Porta/anormalidades , Veias Cavas/anormalidades , Pesos e Medidas , Ultrassonografia Doppler/veterinária , Fluxo Sanguíneo Regional
2.
Pesqui. vet. bras ; 30(7): 593-604, 2010. ilus
Artigo em Português | VETINDEX | ID: vti-14425

Resumo

A imagem por ressonância magnética (IRM) é o método de diagnóstico por imagem não invasivo mais sensível para avaliar as partes moles, particularmente o encéfalo, porém trata-se de uma técnica onerosa. O método fundamenta-se no fenômeno da ressonância magnética nuclear que ocorre quando núcleos atômicos com propriedades magnéticas presentes no corpo são submetidos a um campo magnético intenso, sendo posteriormente excitados por energia de radiofrequência e gerando, por sua vez, um sinal de onda de radiofrequência capaz de ser captado por uma antena receptora, passando por um processo matemático, chamado Transformada de Fourier, para posterior formação da imagem. Esse estudo objetivou realizar 10 exames completos da cabeça em cadáveres de cães normais à IRM e confeccionar um Atlas com as estruturas identificadas. As imagens foram adquiridas em um aparelho de ressonância magnética Gyroscan S15/HP Philips com campo magnético de 1,5Tesla. Os cadáveres foram posicionados com a cabeça no interior de uma bobina de cabeça humana e foram submetidos a cortes iniciais sagitais a partir de onde se planejou os cortes transversais e dorsais nas sequências de pulso spin-eco T1, T2 e DP. Em T1 utilizou-se TR=400ms e TE=30ms, T2 utilizou-se TR=2000ms e TE=80ms e na DP utilizou-se TR=2000ms e TE=30ms. A espessura do corte foi de 4mm, o número de médias foi igual a 2, a matriz foi de 256x256, o fator foi igual a 1,0 e o campo de visão foi de 14cm. A duração do exame completo da cabeça foi de 74,5minutos. As imagens obtidas com as sequências utilizadas e com a bobina de cabeça humana foram de boa qualidade. Em T1 a gordura tornou-se hiperintensa e o líquido hipointenso. Em T2 a gordura ficou menos hiperintensa e o líquido hiperintenso. A cortical óssea e o ar foram hipointensos em todas as sequências utilizadas devido a baixa densidade de prótons. A sequência DP mostrou o melhor contraste entre a substância branca e cinzenta quando comparada a T2 e a T1. T2 evidenciou o líquido cefalorraquidiano tornando possível a distinção dos sulcos e giros cerebrais. Através do exame de IRM foi possível, pelo contraste, identificar as estruturas ósseas componentes da arquitetura da região, músculos, grandes vasos venosos e arteriais e estruturas do sistema nervoso central, além de elementos do sistema digestório, respiratório e estruturas dos olhos entre outras. Nesse estudo as IRM adquiridas nas sequências T1, DP e T2 foram complementares para o estudo dos aspectos anatômicos da cabeça de cães demonstrando-os com riqueza de detalhes. O tempo requerido para o exame completo da cabeça é compátivel para uso em animais vivos desde que devidamente anestesiados e controlados. Os resultados obtidos por esse trabalho abrem caminho em nosso meio, para o estudo de animais vivos e para o início da investigação de doenças, principalmente as de origem neurológica, visto ser esta técnica excelente para a visibilização do encéfalo.(AU)


Magnetic resonance imaging (MRI) is the most sensitive method of diagnostic imaging to evaluate soft tissues, specially the brain, however it is expensive. The method is based on the nuclear magnetic resonance phenomenon that occurs when atomic nucleus with magnetic proprieties in the body are submitted to a strong magnetic field, and excited with radio frequency generating a radio frequency signal captured by a receptive antenna. The signal is processed by Fourier Transform for the image formation. This study had the objective to obtain 10 complete exams of heads in cadavers of normal dogs to MRI and to make an Atlas of head structures. The images were obtained with a magnetic resonance unit Gyroscan S15/HP Philips using a magnetic field of 1,5Tesla. The cadavers were positioned with the head into a human head coil and submitted to sagittal slices used to plan transverse and dorsal slices in T1, T2 and DP spin-echo sequences. In T1 we adjusted TR=400ms and TE=30ms, in T2 TR=2000ms and TE=80ms and in DP TR=2000ms and TE=30ms. The slice thickness was 4mm, the number of averages 2, the matrix 256x256, the factor 1,0 and the field of view 14cm. The duration of the complete exam of the head was 74,5minutes. The images obtained with the described sequences and with the human head coil was of good quality. In T1 fat was hyperintense and fluid was hypointense. In T2 fat was less hyperintense and fluid was hyperintense. The cortical bone and the air were hypointense in all sequences used because of the low proton density. The DP sequence showed the best contrast between white and gray matter when compared with T2 and T1 sequences. Distinction of cerebral sulcus and gyrus was possible because T2 showed the cerebrospinal fluid. The identification of bone structures that compound the region, muscles, main venous and arterial vessels and structures of the central nervous system, besides elements of the digestory and respiratory systems and structures of the eyes among others was possible through contrast obtained with MRI. In this study the MRI acquired in T1, DP and T2 were complementary for the anatomic study of the head and been able to demonstrate the structures of the canine head with rich anatomic details. The time used to do the complete exam of the head is compatible with the use in live animals since properly anesthetized and controlled. We had opened a way for the study of live animals and for the beginning of disease investigation, mainly that of neurologic origin because this technique is excellent for brain visualization.(AU)


Assuntos
Animais , Cães , Imageamento por Ressonância Magnética/veterinária , Cabeça/anatomia & histologia , Cães
3.
Ci. Rural ; 37(2)2007.
Artigo em Português | VETINDEX | ID: vti-705247

Resumo

A duplex ultrasound system incorporating a pulsed wave Doppler ultrasound probe with conventional B-mode real-time imaging was used to evaluate the biometric and the hemodynamic of abdominal aorta and external iliac arteries of a hundred and thirty one normal dogs. Results of biometrics of abdominal aorta, presented a mean diameter of 0.80cm in its diaphragmatic segment (AOD); 0.74cm in its segment caudal to the renal arteries (AOR) and 0.69cm in the segment cranial to its termination (AOT). The right-external-iliac artery (AIED) presented a mean diameter of 0.42cm and the left-external iliac artery (AIEE) a mean diameter of 0.39cm. The hemodynamic study of the abdominal aorta presented a medium systolic peak velocity to AOR of 104cm per sec.; to AOT of 99.61cm per sec.; to AIED of 85.47cm per sec. and to AIEE of 99.51cm per sec. Correlations of different intensities between the vascular diameters have been verified between the measured points and the corporeal biometric factors (Crown Rump-Lenght). Low correlations have been observed regarding the diameters in relation to the age.


O ultra-som bidimensional e o ultra-som Doppler foram utilizados para avaliar a biometria e a hemodinâmica da aorta abdominal e artérias ilíacas externas de 131cães clinicamente normais. Os resultados da avaliação biométrica da aorta abdominal indicaram um diâmetro médio de 0,80cm para o seu segmento diafragmático (AOD); 0,74cm para o seu segmento caudal às artérias renais (AOR) e 0,69cm para o segmento cranial à sua bifurcação (AOT). A artéria ilíaca externa direita (AIED) apresentou o diâmetro médio de 0,42cm e a artéria ilíaca externa esquerda (AIEE) o diâmetro médio de 0,39. O estudo hemodinâmico da aorta abdominal apresentou velocidade de pico sistólico médio de 104,00cm/s para AOR; 99,61cm/s para AOT; 85,47cm/s para AIED e 99,51cm/s para AIEE. Verificaram-se correlações de diferentes intensidades entre os diâmetros vasculares em diferentes pontos de tomadas e os fatores biométricos corpóreos (CRL). Correlações baixas foram observadas quando esses diâmetros foram confrontados com a idade.

4.
Artigo em Português | LILACS-Express | VETINDEX | ID: biblio-1477039

Resumo

A duplex ultrasound system incorporating a pulsed wave Doppler ultrasound probe with conventional B-mode real-time imaging was used to evaluate the biometric and the hemodynamic of abdominal aorta and external iliac arteries of a hundred and thirty one normal dogs. Results of biometrics of abdominal aorta, presented a mean diameter of 0.80cm in its diaphragmatic segment (AOD); 0.74cm in its segment caudal to the renal arteries (AOR) and 0.69cm in the segment cranial to its termination (AOT). The right-external-iliac artery (AIED) presented a mean diameter of 0.42cm and the left-external iliac artery (AIEE) a mean diameter of 0.39cm. The hemodynamic study of the abdominal aorta presented a medium systolic peak velocity to AOR of 104cm per sec.; to AOT of 99.61cm per sec.; to AIED of 85.47cm per sec. and to AIEE of 99.51cm per sec. Correlations of different intensities between the vascular diameters have been verified between the measured points and the corporeal biometric factors (Crown Rump-Lenght). Low correlations have been observed regarding the diameters in relation to the age.


O ultra-som bidimensional e o ultra-som Doppler foram utilizados para avaliar a biometria e a hemodinâmica da aorta abdominal e artérias ilíacas externas de 131cães clinicamente normais. Os resultados da avaliação biométrica da aorta abdominal indicaram um diâmetro médio de 0,80cm para o seu segmento diafragmático (AOD); 0,74cm para o seu segmento caudal às artérias renais (AOR) e 0,69cm para o segmento cranial à sua bifurcação (AOT). A artéria ilíaca externa direita (AIED) apresentou o diâmetro médio de 0,42cm e a artéria ilíaca externa esquerda (AIEE) o diâmetro médio de 0,39. O estudo hemodinâmico da aorta abdominal apresentou velocidade de pico sistólico médio de 104,00cm/s para AOR; 99,61cm/s para AOT; 85,47cm/s para AIED e 99,51cm/s para AIEE. Verificaram-se correlações de diferentes intensidades entre os diâmetros vasculares em diferentes pontos de tomadas e os fatores biométricos corpóreos (CRL). Correlações baixas foram observadas quando esses diâmetros foram confrontados com a idade.

5.
São Paulo; s.n; 29/02/2008.
Tese em Português | VETTESES | ID: vtt-5274

Resumo

Foi realizado o estudo morfométrico e o estudo hemodinâmico da veia porta em vinte cães normais, de idade igual e inferior a 120 dias, e em cinco cães portadores de desvio portossistêmico, de idades entre 90 e 360 dias. Dois animais do grupo de cães portadores de desvio portossistêmico foram submetidos ao tratamento cirúrgico (colocação de anel ameróide) e avaliações subseqüentes ao procedimento cirúrgico foram realizados. Nos cães do grupo normal, as margens hepáticas apresentaram-se entre 1,50cm e 3,00cm depois da margem costal. As médias dos diâmetros médios da veia porta (VP), veia cava caudal (VCC) e aorta abdominal (AO) obtidas foram respectivamente, 0,38cm, 0,37cm e 0,41cm. As proporções entre os diâmetros médios VP/VCC e VP/AO apresentaram médias de 1,10 e 0,94, respectivamente. As médias das áreas de VP, VCC e AO mediram respectivamente, 0,12cm2, 0,11cm2 e 0,14cm2. No estudo hemodinâmico de VP destes animais, utilizando-se o ultra-som Doppler, a velocidade média de fluxo sangüíneo portal (VMFSP) mediu 17,77cm/s. A média de fluxo sangüíneo portal (FSP) mediu 83,11ml/min/kg. O índice de congestão (IC) apresentou média de 0,009. Para o grupo de cães portadores de desvio portossistêmico, o fígado apresentou redução de seu volume, sendo visibilizado entre 1,00cm e 2,00cm antes da margem costal. No estudo morfométrico, as médias dos diâmetros médios obtidos de VP, VCC e AO mensuraram respectivamente, 0,52cm, 0,79cm e 0,58cm. As proporções entre os diâmetros médios VP/VCC e VP/AO mediram respectivamente, 0,62 e 0,84. As médias das áreas de VP, VCC e AO mediram respectivamente, 0,22cm2, 0,56cm2 e 0,27cm2. Ao ultra-som Doppler a VMFSP mediu 26,10cm/s e a média do IC obtido foi de 0,009. Nos animais do grupo de cães portadores de desvio portossistêmico submetidos ao procedimento cirúrgico, foi observado aumento de volume hepático na semana seguinte à colocação do anel ameróide e a VMFSP manteve-se inferior a 19,50cm/s em todos exames subseqüentes à cirurgia no cão 1


The morphometry and haemodynamic aspects of portal vein were studied in 20 normal dogs with less than 120 days of age and in 5 dogs presenting portosystemic shunting with ages between 90 and 360 days. 2 dogs of the group of animals with portosystemic shunting were submitted to surgical treatment, using a specialized device (ameroid constrictor). Subsequent evaluations were made after the surgical procedure. In the normal group the hepatic margins were seen 1.50cm to 3.00cm below de costal margin. Collected data indicated that the mean diameter of portal vein (VP), caudal vena cava (VCC) and abdominal aorta (AO) measured respectively, 0.38cm, 0.37cm and 0.41cm. The VP/VCC and VP/AO mean ratios were respectively, 1.10 and 0.94. The average of VP, VCC and AO areas were respectively, 0.12cm2, 0.11cm2 and 0.14cm2. The haemodynamic of portal vein was studied by ultrasound Doppler and the mean velocity of portal blood flow (VMFSP) measured was 17.77cm/s. It was verified that portal blood flow (FSP) average was 83.11ml/min/kg and the congestion index (IC) average was 0.009. In the group of animals presenting portosystemic shunting, the hepatic margins were seen 1.00cm to 2.00cm above the costal margin. The morphometry of VP, VCC and AO presented a mean diameter of 0.52cm, 0.79cm and 0.59cm, respectively. The VP/VCC and VP/AO mean ratios were respectively, 0.62 and 0.84. The average of VP, VCC and AO areas were respectively, 0.22cm2, 0.56cm2 and 0.27cm2. The haemodynamic study demonstrated that the VMFSP measured was 26.10cm/s and de IC average was 0.009. In the group of animals with portosystemic shunting which were submitted to surgical treatment, an increase of the liver size was seen from the first ultrasonographic evaluation. The measurements of VMFSP collected in the post surgical period were <= 19.50cm/s in dog 1

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA