Resumo
The objective of this study was to establish ophthalmic parameters in the Pomeranian dog breed. Schirmer tear test (STT), tear breakup time test (TBUTT), Jones test (JT), aesthesiometry, biomicroscopy, tonometry, non-contact specular microscopy (SM), ophthalmoscopy and ultrasonography (US) were carried out 48 eyes of 24 male and female Pomeranian dogs from a breeding kennel. Descriptive statistics was applied for data analysis. Means and standard errors found for STT, TBUT, JT, esthesiometry and tonometry were 24.310±0.448mm/min, 14.570±0.406s., 8.420±1.571min, 3.667±0.157cm and 17.960±0.697mmHg, respectively. For biomicroscopy, 43.75% of the eyes presented caruncle trichiasis, 25% chromodacryorrhea, 25% medial entropion and 10,42% distichiasis. SM showed endothelial cells density of 1958.285±36.760 cells/mm². For hexagonality, endothelial cells area and central corneal thickness were 62.229±2.183%, 519.231±9.853mm², 0.567±0.006mm, respectively. Ophthalmoscopy presented a pattern described in other breeds. Amelanotic fundus was reported in 8.33% of the eyes. The US means and standard errors for axial length of the eyeball, lens thickness, anterior and vitreous chamber depth were 16.859±0.148mm, 6.651±0.081mm, 2.673±0.091mm and 7.485±0.101mm. Mild changes in the lacrimal evaluation parameters were influenced by eyelid changes in STT type I. Increased corneal sensitivity was observed in the breed.
O objetivo do estudo foi estabelecer os parâmetros oftálmicos na raça Spitz Alemão anão. Realizaram-se teste lacrimal de Schirmer (TLS), tempo de ruptura do filme lacrimal (TRFL), teste de Jones (TJ), estesiometria, biomicroscopia, tonometria, microscopia especular (MS), oftalmoscopia e ultrassonografia (US) em 48 olhos de 24 cães machos e fêmeas da raça Sptiz Alemão anão, oriundos de canil de criação. Aplicou-se estatística descritiva. As médias e erros padrões encontrados para TLS, TRL, TJ, estesiometria e tonometria foram 24,310±0,448mm/min, 14,570±0,406s., 8,420±1,571min, 3,667±0,157cm e 17,960±0,697mmHg, respectivamente. À biomicroscopia, 43,75% dos olhos apresentaram triquíase de carúncula, 25% cromodacriorreia, 25% entrópio de canto medial e 10,42% distiquíases. À MS, os valores para densidade das células endoteliais, hexagonalidade, área das células endoteliais e espessura corneal central foram 1958,285±36,760 cells/mm², 62,229±2,183%, 519,231±9,853mm² e 0,567±0,006mm, respectivamente. À oftalmoscopia, padrão conforme descrito para cães. Fundo amelanótico foi reportado em 8,33% das retinas. Ao US, os valores identificados para diâmetro axial horizontal, espessura da lente, profundidade das câmaras anterior e posterior foram 16,859±0,148mm, 6,651±0,081mm, 2,673±0,091mm and 7,485±0,101mm. Leves alterações nos parâmetros lacrimais foram influenciadas por alterações palpebrais no TLS tipo I. Sensibilidade corneana aumentada foi identificada na raça.
Assuntos
Animais , Cães , Oftalmologia , Animais de Estimação , Aparelho LacrimalResumo
Eyes from brachycephalic dogs were studied by acoustic radiation force impulse (ARFI) elastography to establish quantitative and qualitative reference values related to the shape and rigidity of some ocular structures. Eighty-four eyes from 42 adult brachycephalic dogs were included in this study. Animals were subjected to physical, laboratory, and ophthalmic examinations. Following confirmation of good health, the dogs were subjected to ultrasonography and ARFI elastography, emphasizing the optic nerve, ciliary body, and lens. On qualitative elastography, homogeneous characteristics were observed on the ciliary body and optic nerve. Aqueous and vitreous humors were visualized as mosaic-like images. Quantitative elastography showed the mean optic nerve shear wave velocity (SWV) was 1.01±0.27m/s, temporal ciliary body was 0.91±0.24m/s, and nasal ciliary body was 0.91±0.3m/s. The SWV of the lens values were out of range, this value was not detectable by this software. Elastography has proved to be a non-invasive procedure and feasible in dogs. The establishmentof the parameters of degree of rigidity of ocular structures will serve as a baseline for animals with eye disorders. Results may be extrapolated to primary research on the applicability of ARFI in the evaluation of ocular bulb in humans.(AU)
Estruturas oculares de cães braquicéfalos foram estudadas por elastografia acoustic radiation force impulse (ARFI) para estabelecer valores quantitativos e qualitativos de referência relacionados com a forma e a rigidez de algumas estruturas oculares. Foram avaliados 84 olhos de 42 cães braquicéfalos neste estudo. Os animais foram submetidos aos exames físico, laboratorial e aos exames oftalmológicos. Após a confirmação da sanidade dos pacientes, os cães foram submetidos à ultrassonografia e à elastografia ARFI, enfatizando-se o nervo óptico, o corpo ciliar e a lente. Para elastografia qualitativa, foram observadas características homogêneas no corpo ciliar e no nervo óptico. Os humores aquoso e vítreo foram visibilizados como imagens tipo mosaico. A elastografia quantitativa demonstrou velocidades de cisalhamento para nervo óptico de 1,01±0,27m/s, para corpo ciliar temporal de 0,91±0,24m/s e para corpo ciliar nasal de 0,91±0,3m/s. Valores dessas velocidades para lentes apresentaram-se fora do intervalo: X.XXm/s. A elastografia provou ser um procedimento não invasivo e viável para cães. Estabelecidos os parâmetros do grau de rigidez das estruturas oculares, futuramente tais dados servirão como padrão para avaliação de animais com os distúrbios oculares. Os resultados podem ser extrapolados para a pesquisa primária sobre a aplicabilidade da ARFI na avaliação do bulbo ocular em seres humanos.(AU)
Assuntos
Animais , Cães , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Técnicas de Imagem por Elasticidade/veterinária , Anormalidades do Olho/diagnóstico por imagem , Cães/anormalidadesResumo
Eyes from brachycephalic dogs were studied by acoustic radiation force impulse (ARFI) elastography to establish quantitative and qualitative reference values related to the shape and rigidity of some ocular structures. Eighty-four eyes from 42 adult brachycephalic dogs were included in this study. Animals were subjected to physical, laboratory, and ophthalmic examinations. Following confirmation of good health, the dogs were subjected to ultrasonography and ARFI elastography, emphasizing the optic nerve, ciliary body, and lens. On qualitative elastography, homogeneous characteristics were observed on the ciliary body and optic nerve. Aqueous and vitreous humors were visualized as mosaic-like images. Quantitative elastography showed the mean optic nerve shear wave velocity (SWV) was 1.01±0.27m/s, temporal ciliary body was 0.91±0.24m/s, and nasal ciliary body was 0.91±0.3m/s. The SWV of the lens values were out of range, this value was not detectable by this software. Elastography has proved to be a non-invasive procedure and feasible in dogs. The establishmentof the parameters of degree of rigidity of ocular structures will serve as a baseline for animals with eye disorders. Results may be extrapolated to primary research on the applicability of ARFI in the evaluation of ocular bulb in humans.(AU)
Estruturas oculares de cães braquicéfalos foram estudadas por elastografia acoustic radiation force impulse (ARFI) para estabelecer valores quantitativos e qualitativos de referência relacionados com a forma e a rigidez de algumas estruturas oculares. Foram avaliados 84 olhos de 42 cães braquicéfalos neste estudo. Os animais foram submetidos aos exames físico, laboratorial e aos exames oftalmológicos. Após a confirmação da sanidade dos pacientes, os cães foram submetidos à ultrassonografia e à elastografia ARFI, enfatizando-se o nervo óptico, o corpo ciliar e a lente. Para elastografia qualitativa, foram observadas características homogêneas no corpo ciliar e no nervo óptico. Os humores aquoso e vítreo foram visibilizados como imagens tipo mosaico. A elastografia quantitativa demonstrou velocidades de cisalhamento para nervo óptico de 1,01±0,27m/s, para corpo ciliar temporal de 0,91±0,24m/s e para corpo ciliar nasal de 0,91±0,3m/s. Valores dessas velocidades para lentes apresentaram-se fora do intervalo: X.XXm/s. A elastografia provou ser um procedimento não invasivo e viável para cães. Estabelecidos os parâmetros do grau de rigidez das estruturas oculares, futuramente tais dados servirão como padrão para avaliação de animais com os distúrbios oculares. Os resultados podem ser extrapolados para a pesquisa primária sobre a aplicabilidade da ARFI na avaliação do bulbo ocular em seres humanos.(AU)
Assuntos
Animais , Cães , Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/veterinária , Anormalidades do Olho/diagnóstico por imagem , Cães/anormalidadesResumo
This study aimed to evaluate the microbiota of donor rabbit corneas stored for tectonic transplantation purposes. Swabs from both corneas of 20 rabbits were carefully collected and submitted to microorganism isolation and identification. After this first swab collection, rabbits were euthanized for reasons other than this project and the eyes were enucleated. The corneas were collected and stored to compose the cornea tissue bank. Corneas were stored in a 0.3% tobramycin solution at -20ºC. After 30 days, the corneas were thawed at room temperature and removed from the antibiotic. New swabs were obtained from the corneas and submitted to microorganism isolation and identification. Gram positive organisms were predominant in the rabbit corneal flora before storage and the Staphylococcus sp. was the most common microorganism isolated from those samples. No growth was observed on the samples collected after storage. The methods used for collection and storage of the corneas were efficient to constitute a sterile donor corneal tissue bank.(AU)
Analisaram-se córneas armazenadas para transplantes tectônicos usando-se suabes coletados de 20 coelhos, visando ao isolamento e à identificação de microrganismos. Após a coleta das amostras, os coelhos foram submetidos à eutanásia, por razões alheias ao estudo, e enucleados. As córneas foram coletadas e armazenadas a fim de se constituir o banco de córneas. O armazenamento deu-se em solução de tobramicina 0,3% a -20ºC, por 30 dias. Após esse período, as córneas foram descongeladas à temperatura ambiente e removidas da solução de antibiótico. Novos suabes foram coletados e submetidos ao isolamento e à identificação dos microrganismos. A flora corneal mostrou-se predominantemente composta por bactérias Gram positivas, sendo o Staphylococcus sp. o mais identificado. Não se verificou crescimento de colônias bacterianas ou fúngicas nas amostras após o armazenamento. Considerando-se a maneira como a pesquisa foi concebida e as injunções do meio em que ela foi realizada, há como admitir, pela ausência de crescimento microbiano nas amostras armazenadas, que a técnica de armazenamento empregada é segura para a estocagem de córneas destinadas a transplantes.(AU)