Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Arq. bras. med. vet. zootec. (Online) ; 73(5): 1047-1057, Sept.-Oct. 2021. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1345276

Resumo

Colostrum is the main source of immunoglobulins (Ig) for neonate piglets and plays a crucial role within the health and growth of the piglet. Currently in pig farming, there are still no widespread practical methods for measuring the Ig concentration in colostrum at herd level. We evaluated sows' colostrum IgG concentration using an optical and a digital Brix refractometer and their performance was correlated to an IgG ELISA test, and flow cytometry. Colostrum concentrations of IgG and IgA averaged 74.05 ± 21.37mg/mL and 20.2 ± 5.32mg/mL respectively. The mean value of the Brix percentages for optical refractometer was 26.32%, and for digital was 28.32%. The Brix refractometer measurements of colostrum samples presented high correlation for IgG content analyzed by ELISA (Optical = 0.74, Digital = 0.87; P <0.001). Considering the immunophenotyping, the values for IgG and IgA lymphoblasts indicated a highly significant relationship to ELISA (IgG=0.77, IgA=0.84; P<0.001). The Brix refractometer can be considered a useful tool to be included in a colostrum monitoring program to improve potentially neonatal health. In addition, we demonstrated that flow cytometry can be an important tool to analyze and characterize the immunological potential of sow colostrum.(AU)


O colostro é a principal fonte de imunoglobulinas (Ig) para leitões recém-nascidos e desempenha um papel crucial na saúde e no crescimento dos leitões. Atualmente, na suinocultura, ainda não existem métodos amplamente utilizados na prática de produção para medir a concentração de imunoglobulinas no colostro suíno. Avaliou-se a concentração de IgG no colostro de porcas usando refratômetros Brix óptico e digital, e o desempenho foi comparado com ELISA e citometria de fluxo. As concentrações de IgG e IgA no colostro foram 74,05 ± 21,37mg/mL e 20,2 ± 5,32mg/mL, respectivamente. A percentagem de Brix média das amostras de colostro para o refratômetro óptico foi 26,32%, e para o digital foi 28,32%. As medições dos refratômetros de Brix apresentaram elevada correlação com a concentrações de IgG medidas por ELISA (óptico=0,74, digital=0,87; P<0,001). Considerando a imunofenotipagem, os valores dos linfoblastos IgG e IgA apresentaram alta correlação com o ELISA (IgG=0,77, IgA=0,84; P<0,001). O refratômetro Brix pode ser considerado uma ferramenta útil para ser incluída em um programa de monitoramento de colostro para melhorar a saúde neonatal. Além disso, foi demonstrado que a citometria de fluxo pode ser uma ferramenta importante para analisar e caracterizar o potencial imunológico do colostro de porcas.(AU)


Assuntos
Animais , Feminino , Gravidez , Imunoglobulina G , Colostro , Sus scrofa/imunologia , Imunoglobulina A , Citometria de Fluxo/veterinária
2.
R. bras. Ci. avíc. ; 21(4): eRBCA-2019-1062, 2019. tab
Artigo em Inglês | VETINDEX | ID: vti-25827

Resumo

The objective of this study was to evaluate different strategies for the oxidative stabilization of rice bran (RB) in the diet of broiler chickens using natural antioxidant additives, synthetic antioxidant additives and heat treatment on performance, breast meat quality and liver fat content and the nutrient digestibility coefficients. Furthermore, the study aimed to evaluate the effects of heat treatment and antioxidants, antioxidant additive treatments, without antioxidants, natural, and synthetic, and to three heat treatments, without heat, dry-heat and moist-heat, after the rice bran was stored for 90 days and then incorporated into the experimental diets. 1080 broilers were arranged in a 3 x 3-factorial randomized design with 10 replicates per treatments. The wet heat treatment of the meal resulted in a higher daily feed intake and body weight at 28 days and better feed conversion than did the meal without heat treatment. No significant interactions were observed between the tested factors on the apparent digestibility of dry matter and ether extract as well as the values of apparent metabolizable energy and apparent metabolizable energy corrected for nitrogen. However, there was significant interaction between the tested factors on the nitrogen retention coefficient; the natural antioxidant and dry heat-treated meal combination presented a lower crude protein digestibility coefficient than those without heat treatment. In conclusion, thermal treatment of this bran proved to be more effective as demonstrated by the performance responses of the birds. Broiler chickens reared up to 28 days of age consuming diets containing 6.5% RB stabilized by heat treatment showed better performance, and the use of antioxidants was not necessary.(AU)


Assuntos
Animais , Ração Animal/análise , Galinhas/metabolismo , Antioxidantes/análise , Tratamento Térmico/análise , Óleo de Farelo de Arroz/análise
3.
Rev. bras. ciênc. avic ; 21(4): eRBCA, 2019. tab
Artigo em Inglês | VETINDEX | ID: biblio-1490692

Resumo

The objective of this study was to evaluate different strategies for the oxidative stabilization of rice bran (RB) in the diet of broiler chickens using natural antioxidant additives, synthetic antioxidant additives and heat treatment on performance, breast meat quality and liver fat content and the nutrient digestibility coefficients. Furthermore, the study aimed to evaluate the effects of heat treatment and antioxidants, antioxidant additive treatments, without antioxidants, natural, and synthetic, and to three heat treatments, without heat, dry-heat and moist-heat, after the rice bran was stored for 90 days and then incorporated into the experimental diets. 1080 broilers were arranged in a 3 x 3-factorial randomized design with 10 replicates per treatments. The wet heat treatment of the meal resulted in a higher daily feed intake and body weight at 28 days and better feed conversion than did the meal without heat treatment. No significant interactions were observed between the tested factors on the apparent digestibility of dry matter and ether extract as well as the values of apparent metabolizable energy and apparent metabolizable energy corrected for nitrogen. However, there was significant interaction between the tested factors on the nitrogen retention coefficient; the natural antioxidant and dry heat-treated meal combination presented a lower crude protein digestibility coefficient than those without heat treatment. In conclusion, thermal treatment of this bran proved to be more effective as demonstrated by the performance responses of the birds. Broiler chickens reared up to 28 days of age consuming diets containing 6.5% RB stabilized by heat treatment showed better performance, and the use of antioxidants was not necessary.


Assuntos
Animais , Antioxidantes/análise , Galinhas/metabolismo , Ração Animal/análise , Tratamento Térmico/análise , Óleo de Farelo de Arroz/análise
4.
Arq. bras. med. vet. zootec ; 68(5): 1105-1111, set.-out. 2016. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-827913

Resumo

Computed tomography of the brain is necessary as part of the diagnosis of lesions of the central nervous system. In this study we used six domestic cats, male or female, aged between one and five years, evaluated by Computed Tomography (CT) examination without clinical signs of central nervous system disorders. Two euthanized animals stating a condition unrelated to the nervous system were incorporated into this study. The proposal consisted in establishing detailed anatomical description of tomographic images of normal brain of cats, using as reference anatomical images of cross sections of the stained brain and cranial part, with thicknesses similar to the planes of the CT images. CT examinations were performed with and without intravenous iodinated contrast media for live animals. With one euthanized animal, the brain was removed and immediately preserved in 10% formalin for later achievement in cross-sectional thickness of approximately 4mm and staining technique of Barnard, and Robert Brown. The head of another animal was disarticulated in the Atlanto-occipital region and frozen at -20ºC then sliced to a thickness of about 5mm. The description of visualized anatomical structures using tomography is useful as a guide and allows transcribing with relative accuracy the brain region affected by an injury, and thus correlating it with the clinical symptoms of the patient, providing additional information and consequent improvement to veterinarians during the course of surgical clinic in this species.(AU)


A tomografia computadorizada do cérebro é de suma importância como parte do diagnóstico de lesões do sistema nervoso central. Neste estudo, foram utilizados seis felinos domésticos, machos ou fêmeas, com idade entre um e cinco anos, avaliados pela tomografia computadorizada (TC), sem sinais clínicos de distúrbios do sistema nervoso central. Dois cadáveres indicando a condição relacionada com o sistema nervoso foram incorporados ao presente estudo. A proposta consistiu na criação da descrição anatômica detalhada das imagens tomográficas de cérebro normal de gatos, usando como referência a imagens anatômicas de secções transversais do cérebro coradas, realizadas com espessuras similares aos planos das imagens tomográficas. Exames de TC foram realizados com e sem contraste iodado intravenoso para os animais vivos. Em um dos cadáveres, o cérebro foi removido e imediatamente preservado em formalina a 10% para a realização posterior da técnica de coloração de Barnard e Robert Brown, além de cortes transversais com espessura de, aproximadamente, 4mm. O crânio do outro cadáver foi desarticulado na região atlanto-occipital e congelado a -20ºC. Em seguida, foi realizado corte com espessura de cerca de 5mm. A descrição das estruturas anatômicas visualizadas foi útil e serve como guia, permitindo descrever com relativa precisão a estrutura cerebral normal ou lesionada, e, portanto, correlacionando-a com os sintomas clínicos de um paciente, o que fornece informações adicionais e consequente aprimoramento de veterinários no curso de clínica cirúrgica para essa espécie.(AU)


Assuntos
Animais , Gatos , Cérebro/anatomia & histologia , Cérebro/diagnóstico por imagem , Neuroimagem/veterinária , Tomografia Computadorizada por Raios X/veterinária , Anatomia Transversal
5.
Arq. bras. med. vet. zootec. (Online) ; 68(5): 1105-1111, set.-out. 2016. ilus
Artigo em Inglês | VETINDEX | ID: vti-16520

Resumo

Computed tomography of the brain is necessary as part of the diagnosis of lesions of the central nervous system. In this study we used six domestic cats, male or female, aged between one and five years, evaluated by Computed Tomography (CT) examination without clinical signs of central nervous system disorders. Two euthanized animals stating a condition unrelated to the nervous system were incorporated into this study. The proposal consisted in establishing detailed anatomical description of tomographic images of normal brain of cats, using as reference anatomical images of cross sections of the stained brain and cranial part, with thicknesses similar to the planes of the CT images. CT examinations were performed with and without intravenous iodinated contrast media for live animals. With one euthanized animal, the brain was removed and immediately preserved in 10% formalin for later achievement in cross-sectional thickness of approximately 4mm and staining technique of Barnard, and Robert Brown. The head of another animal was disarticulated in the Atlanto-occipital region and frozen at -20ºC then sliced to a thickness of about 5mm. The description of visualized anatomical structures using tomography is useful as a guide and allows transcribing with relative accuracy the brain region affected by an injury, and thus correlating it with the clinical symptoms of the patient, providing additional information and consequent improvement to veterinarians during the course of surgical clinic in this species.(AU)


A tomografia computadorizada do cérebro é de suma importância como parte do diagnóstico de lesões do sistema nervoso central. Neste estudo, foram utilizados seis felinos domésticos, machos ou fêmeas, com idade entre um e cinco anos, avaliados pela tomografia computadorizada (TC), sem sinais clínicos de distúrbios do sistema nervoso central. Dois cadáveres indicando a condição relacionada com o sistema nervoso foram incorporados ao presente estudo. A proposta consistiu na criação da descrição anatômica detalhada das imagens tomográficas de cérebro normal de gatos, usando como referência a imagens anatômicas de secções transversais do cérebro coradas, realizadas com espessuras similares aos planos das imagens tomográficas. Exames de TC foram realizados com e sem contraste iodado intravenoso para os animais vivos. Em um dos cadáveres, o cérebro foi removido e imediatamente preservado em formalina a 10% para a realização posterior da técnica de coloração de Barnard e Robert Brown, além de cortes transversais com espessura de, aproximadamente, 4mm. O crânio do outro cadáver foi desarticulado na região atlanto-occipital e congelado a -20ºC. Em seguida, foi realizado corte com espessura de cerca de 5mm. A descrição das estruturas anatômicas visualizadas foi útil e serve como guia, permitindo descrever com relativa precisão a estrutura cerebral normal ou lesionada, e, portanto, correlacionando-a com os sintomas clínicos de um paciente, o que fornece informações adicionais e consequente aprimoramento de veterinários no curso de clínica cirúrgica para essa espécie.(AU)


Assuntos
Animais , Gatos , Neuroimagem/veterinária , Cérebro , Tomografia Computadorizada por Raios X/veterinária , Cérebro/anatomia & histologia , Anatomia Transversal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA