1.
Arq. bras. med. vet. zootec. (Online) ; 74(5): 948-953, Sep.-Oct. 2022. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1403408

Resumo

The aim of this study was to develop a modified tibial plateau leveling osteotomy (TPLO) plate and to compare its biomechanical properties with a locking compression plate (LCP) and plate-rod constructs for the stabilization of experimentally induced gap fractures in canine synthetic tibias. The tibial models were assigned to either repair with a modified TPLO plate (Group 1), locking compression plate construct (Group 2), or plate-rod construct (Group 3). The specimens were loaded to failure in axial compression, three-point mediolateral and craniocaudal bending. There was no statistical difference between the three groups regarding stiffness (N/mm) and deformation (mm) in axial compression. The modified TPLO plate achieved load to failure similar to the plate-rod construct in craniocaudal bending. There was no significant difference between groups on mediolateral bending tests regarding load to failure and deformation. Furthermore, there was no significant difference in stiffness between groups 1 and 2. In conclusion, the modified TPLO plate had similar mechanical properties to LCP and plate-rod construct in the axial compression and bending tests. Nonetheless, clinical studies with a large population of dogs are required to determine the value of this new implant in proximal tibial fracture repair.


Objetivou-se desenvolver uma placa de osteotomia niveladora do platô tibial (TPLO) modificada e compará-la biomecanicamente à placa de compressão bloqueada (LCP) e à construção placa-pino intramedular na estabilização da fratura cominutiva proximal em tíbias sintéticas caninas. Para tal, tíbias caninas sintéticas foram divididas em três grupos, sendo o grupo 1 formado pela placa de TPLO modificada, o grupo 2 por placas LCP e o grupo 3 pela construção placa-pino intramedular. Os espécimes foram submetidos à carga até a falha em compressão axial, flexão mediolateral e craniocaudal em três pontos. Não houve diferença estatística entre os três grupos quanto à rigidez (N/mm) e à deformação (mm) nos testes de compressão axial. A placa de TPLO modificada obteve carga até a falha semelhante à construção placa-pino intramedular em flexão craniocaudal. Não houve diferença significativa entre os grupos nos testes de flexão mediolateral em relação à carga até a falha e a deformação, e a variável rigidez não apresentou diferenças significativas entre os grupos 1 e 2. Em conclusão, a placa de TPLO modificada apresentou similaridade mecânica em comparação com a LCP e a construção placa-pino. No entanto, estudos clínicos são necessários para determinar o valor desse novo implante na fixação de fraturas tibiais proximais.


Assuntos
Osteotomia/veterinária , Fraturas da Tíbia/cirurgia , Placas Ósseas/veterinária , Fenômenos Biomecânicos
2.
Arq. bras. med. vet. zootec. (Online) ; 71(5): 1535-1540, set.-out. 2019. ilus, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1038647

Resumo

The objective of this study was to develop a locked tibial-plateau-leveling osteotomy (TPLO) plate and to compare this implant with the conventional bone fixation method using a locked plate to determine bone stabilization against torsion forces. Maximum force, angle at peak torque, and stiffness values were determined. Ten synthetic tibias were used, divided into 2 groups. The results in Group 1 (modified TPLO plate) and Group 2 (locked plate) were assessed using analysis of variance and the means were compared using Tukey's test at 5% probability. There were significant differences in the angle at peak torque and stiffness. The group Modified TPLO plate had higher mean values of stiffness compared with Group locked plate. Group locked plate showed a greater angle at peak torque compared with Group modified TPLO plate. All constructs failed due to tibial fractures distal to the plate. The modified TPLO plate presented higher stiffness indexes than conventional locked plate in torsion. The locked plate presented greater elasticity than modified TPLO plate having greater angle at the peak of torque.(AU)


O objetivo do presente estudo foi desenvolver placa de TPLO bloqueada modificada e avaliar, em ensaio de torção, a estabilização óssea proporcionada pelo implante desenvolvido comparativamente a método de fixação óssea convencional com placa reta bloqueada. As variáveis obtidas foram força máxima, ângulo no pico de torque e rigidez. Foram utilizadas 10 tíbias sintéticas, dividas em dois grupos. Os resultados obtidos do grupo 1 (placa TPLO modificada) e do grupo 2 (placa bloqueada) foram submetidos à análise de variância, e as médias comparadas entre si pelo teste de Tukey a 5% de probabilidade. Houve diferença significativa em relação às variáveis, ângulo no pico de torque e rigidez. Na variável rigidez, a média do grupo placa de TPLO modificada foi maior que a do grupo placa reta bloqueada. Em relação à variável ângulo no pico de torque, o grupo placa reta bloqueada foi superior ao grupo placa de TPLO modificada. Todas as montagens falharam devido à quebra do corpo de prova distal à placa. Conclui-se que a placa de TPLO modificada apresentou maior índice de rigidez que a placa reta convencional sob força de torção. A placa reta bloqueada apresentou maior ângulo no pico de torque, sendo, portando, mais elástica.(AU)


Assuntos
Animais , Cães , Próteses e Implantes/veterinária , Procedimentos Ortopédicos/veterinária , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Tíbia
3.
Arq. bras. med. vet. zootec. (Online) ; 71(5): 1535-1540, set.-out. 2019. ilus, graf
Artigo em Inglês | VETINDEX | ID: vti-25293

Resumo

The objective of this study was to develop a locked tibial-plateau-leveling osteotomy (TPLO) plate and to compare this implant with the conventional bone fixation method using a locked plate to determine bone stabilization against torsion forces. Maximum force, angle at peak torque, and stiffness values were determined. Ten synthetic tibias were used, divided into 2 groups. The results in Group 1 (modified TPLO plate) and Group 2 (locked plate) were assessed using analysis of variance and the means were compared using Tukey's test at 5% probability. There were significant differences in the angle at peak torque and stiffness. The group Modified TPLO plate had higher mean values of stiffness compared with Group locked plate. Group locked plate showed a greater angle at peak torque compared with Group modified TPLO plate. All constructs failed due to tibial fractures distal to the plate. The modified TPLO plate presented higher stiffness indexes than conventional locked plate in torsion. The locked plate presented greater elasticity than modified TPLO plate having greater angle at the peak of torque.(AU)


O objetivo do presente estudo foi desenvolver placa de TPLO bloqueada modificada e avaliar, em ensaio de torção, a estabilização óssea proporcionada pelo implante desenvolvido comparativamente a método de fixação óssea convencional com placa reta bloqueada. As variáveis obtidas foram força máxima, ângulo no pico de torque e rigidez. Foram utilizadas 10 tíbias sintéticas, dividas em dois grupos. Os resultados obtidos do grupo 1 (placa TPLO modificada) e do grupo 2 (placa bloqueada) foram submetidos à análise de variância, e as médias comparadas entre si pelo teste de Tukey a 5% de probabilidade. Houve diferença significativa em relação às variáveis, ângulo no pico de torque e rigidez. Na variável rigidez, a média do grupo placa de TPLO modificada foi maior que a do grupo placa reta bloqueada. Em relação à variável ângulo no pico de torque, o grupo placa reta bloqueada foi superior ao grupo placa de TPLO modificada. Todas as montagens falharam devido à quebra do corpo de prova distal à placa. Conclui-se que a placa de TPLO modificada apresentou maior índice de rigidez que a placa reta convencional sob força de torção. A placa reta bloqueada apresentou maior ângulo no pico de torque, sendo, portando, mais elástica.(AU)


Assuntos
Animais , Cães , Próteses e Implantes/veterinária , Procedimentos Ortopédicos/veterinária , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Tíbia
4.
Arq. bras. med. vet. zootec. (Online) ; 69(4): 901-907, jul.-ago. 2017. ilus, tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-876682

Resumo

Pelvic fractures correspond to 20 to 30 % of the fractures observed in dogs. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques is of utmost importance to assess the best way of treating these injuries. This study compared, biomechanically, the use of a dynamic compression plate (DCP) and screws (group 1) or screws and polymethylmethacrylate (PMMA) (group 2) to stabilize an iliac fracture using a static test. Sixteen canine synthetic hemi-pelvises (test specimens) with a transverse iliac osteotomy were used. After fixation with implants, a load was applied to the acetabulum until failure. Group 1 maximal compressive load was 133.9±18.60 N, displacement at yield 21.10±3.59mm and stiffness 125.22±12.25N/mm. Group 2 maximal compressive load was 183.50±27.38N, displacement at yield 16.66±5.42mm and stiffness 215.68±33.34N/mm. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate since it resisted a greater load in all test specimens.(AU)


As fraturas da pelve são frequentes em cães, correspondendo a 20-30% das fraturas encontradas na espécie. A grande maioria delas é tratada cirurgicamente, principalmente aquelas que apresentam desvio ósseo. O estudo mecânico das técnicas cirúrgicas é de extrema importância para avaliação da melhor maneira de tratamento destas lesões. O objetivo deste estudo foi comparar, do ponto de vista biomecânico, a fixação das fraturas do ílio utilizando uma placa de compressão dinâmica ou parafusos associados ao polimetilmetacrilato, por meio de um teste estático. Foram utilizadas 16 hemipelves caninas de origem sintética, nas quais uma osteotomia transversa foi realizada no corpo do ílio. As fixações foram divididas em dois grupos: fixação com placa de compressão dinâmica e parafusos (grupo1) ou parafusos associados ao polimetilmetacrilato (grupo 2). Posteriormente à fixação dos implantes foi aplicada uma carga no acetábulo de cada corpo de prova até a falha. O grupo 2 apresentou força máxima de aplicação de carga a média de 133.9±18.60N, deflexão 21.10±3.59mm e rigidez 125.22±12.25N/mm. O grupo 2 apresentou força máxima de aplicação de carga a média de 183.50±27.38N, deflexão 16.66±5.42mm e rigidez 215.68±33.34N/mm. A estabilização com o polimetilmetacrilato mostrou ser mais resistente, pois resistiu a uma maior quantidade de carga em relação à placa de compressão dinâmica, em todos os corpos de prova.(AU)


Assuntos
Animais , Cães , Fenômenos Biomecânicos , Fixação Interna de Fraturas/veterinária , Fixadores Internos/veterinária , Pelve/lesões , Polimetil Metacrilato/uso terapêutico , Poliuretanos , Fraturas Ósseas/cirurgia
5.
Arq. bras. med. vet. zootec. (Online) ; 69(4): 901-907, jul.-ago. 2017. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-18003

Resumo

Pelvic fractures correspond to 20 to 30 % of the fractures observed in dogs. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques is of utmost importance to assess the best way of treating these injuries. This study compared, biomechanically, the use of a dynamic compression plate (DCP) and screws (group 1) or screws and polymethylmethacrylate (PMMA) (group 2) to stabilize an iliac fracture using a static test. Sixteen canine synthetic hemi-pelvises (test specimens) with a transverse iliac osteotomy were used. After fixation with implants, a load was applied to the acetabulum until failure. Group 1 maximal compressive load was 133.9±18.60 N, displacement at yield 21.10±3.59mm and stiffness 125.22±12.25N/mm. Group 2 maximal compressive load was 183.50±27.38N, displacement at yield 16.66±5.42mm and stiffness 215.68±33.34N/mm. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate since it resisted a greater load in all test specimens.(AU)


As fraturas da pelve são frequentes em cães, correspondendo a 20-30% das fraturas encontradas na espécie. A grande maioria delas é tratada cirurgicamente, principalmente aquelas que apresentam desvio ósseo. O estudo mecânico das técnicas cirúrgicas é de extrema importância para avaliação da melhor maneira de tratamento destas lesões. O objetivo deste estudo foi comparar, do ponto de vista biomecânico, a fixação das fraturas do ílio utilizando uma placa de compressão dinâmica ou parafusos associados ao polimetilmetacrilato, por meio de um teste estático. Foram utilizadas 16 hemipelves caninas de origem sintética, nas quais uma osteotomia transversa foi realizada no corpo do ílio. As fixações foram divididas em dois grupos: fixação com placa de compressão dinâmica e parafusos (grupo1) ou parafusos associados ao polimetilmetacrilato (grupo 2). Posteriormente à fixação dos implantes foi aplicada uma carga no acetábulo de cada corpo de prova até a falha. O grupo 2 apresentou força máxima de aplicação de carga a média de 133.9±18.60N, deflexão 21.10±3.59mm e rigidez 125.22±12.25N/mm. O grupo 2 apresentou força máxima de aplicação de carga a média de 183.50±27.38N, deflexão 16.66±5.42mm e rigidez 215.68±33.34N/mm. A estabilização com o polimetilmetacrilato mostrou ser mais resistente, pois resistiu a uma maior quantidade de carga em relação à placa de compressão dinâmica, em todos os corpos de prova.(AU)


Assuntos
Animais , Fixadores Internos/veterinária , Fixação Interna de Fraturas/veterinária , Pelve/lesões , Fenômenos Biomecânicos , Polimetil Metacrilato/uso terapêutico , Poliuretanos , Fraturas Ósseas/cirurgia
6.
Arq. bras. med. vet. zootec ; 59(1): 127-133, fev. 2007. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-7451

Resumo

It was studied the arrangement of the collagen fibrils of the medial collateral ligament of the canine elbow joint and evaluated its diameter, when it was isolated or associated to the oblique ligament and loaded in tension until failure. Eighteen joints were divided in three groups. The first group had the medial collateral ligament collected and not loaded, the second group had the medial collateral ligament tested separately and the third group had both ligaments associately tested. Medial collateral ligament not submitted to strain presented a wavy and reticular pattern of the collagen fibers, which was not totally destroyed when it was loaded associated to the oblique ligament, and totally loses the reticular pattern when stretched separately. When the medial collateral ligament was loaded in tension separately, the mean collagen fibrils diameter increased in relation to the group not submitted to the tensile strain. Associated to the oblique ligament, the mean collagen fibrils diameter was the largest in the insertion area and the smallest in the mid-substance, in relation to the other groups. It was concluded that the oblique ligament could favor the integrity of the medial collateral ligament insertion area, facilitating its reconstruction after lesion with larger efficiency.(AU)


Foram estudados o arranjo e o diâmetro médio das fibrilas colágenas do ligamento colateral medial da articulação do cotovelo do cão, isolado ou associado ao ligamento oblíquo e tracionado até a ruptura. Dezoito articulações foram divididas em três grupos. O primeiro grupo teve o ligamento colateral medial coletado, mas não tracionado; o segundo grupo teve o ligamento colateral medial tracionado isoladamente; o terceiro grupo teve os ligamentos colateral medial e oblíquo tracionados associadamente. O ligamento colateral medial não submetido ao ensaio de tração apresentou um padrão ondulado das fibras colágenas, o qual não foi totalmente destruído quando foi tracionado, associado ao ligamento oblíquo, e perdeu totalmente o padrão reticular das fibras colágenas quando testado isoladamente. Quando o ligamento colateral medial foi submetido à tensão isoladamente, o diâmetro médio das fibrilas colágenas aumentou em relação ao grupo não submetido à tensão. Associado ao ligamento oblíquo, o diâmetro médio das fibrilas colágenas foi o maior na região de inserção e o menor na região média, em relação aos outros grupos. Concluiu-se que o ligamento oblíquo pode favorecer a integridade da região de inserção do ligamento colateral medial, aumentando a eficácia de sua reconstrução após a lesão.(AU)


Assuntos
Animais , Masculino , Feminino , Articulação do Cotovelo/anatomia & histologia , Ligamentos Colaterais/anatomia & histologia , Ligamentos Colaterais/lesões , Colágenos Associados a Fibrilas/efeitos adversos , Cães