Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Acta cir. bras ; 37(2): e370201, 2022. tab, graf, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1374072

Resumo

Purpose: To evaluate fibrosis formation and number of macrophages in capsules formed around textured implants without and with mesh coverage. Methods: Fibrosis was analyzed through transforming growth factor-beta 1 (TGF-ß1) immunomarker expression and the number of macrophages through CD68 percentage of cells in magnified field. Sixty female Wistar rats were distributed into two groups of 30 rats (unmeshed and meshed). Each group was then subdivided into two subgroups for postoperative evaluation after 30 and 90 days. The p value was adjusted by Bonferroni lower than 0.012. Results: No difference was observed in fibrosis between meshed and unmeshed groups (30 days p = 0.436; 90 days p = 0.079) and from 30 to 90 days in the unmeshed group (p = 0.426). The meshed group showed higher fibrosis on the 90th day (p = 0.001). The number of macrophages was similar between groups without and with mesh coverage (30 days p = 0.218; 90 days p = 0.044), and similar between subgroups 30 and 90 days (unmeshed p = 0.085; meshed p = 0.059). Conclusions: In the meshed group, fibrosis formation was higher at 90 days and the mesh-covered implants produced capsules similar to microtextured ones when analyzing macrophages. Due to these characteristics, mesh coating did not seem to significantly affect the local fibrosis formation.


Assuntos
Animais , Feminino , Ratos , Telas Cirúrgicas/veterinária , Fibrose/veterinária , Antígenos CD/análise , Implantes de Mama/veterinária , Implante Mamário/instrumentação , Fator de Crescimento Transformador beta1/análise , Ratos Wistar/cirurgia
2.
Acta cir. bras ; 36(5): e360505, 2021. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1278105

Resumo

ABSTRACT Purpose To evaluate capsules formed by microtextured silicone implants with and without Parietex® mesh coverage histologically. Methods Sixty Wistar rats were divided in two groups (meshed and unmeshed). Each group was, then, divided into two subgroups for evaluation at 30 and 90 days. Capsules were analyzed based on hematoxylin and eosin (HE) and picrosirius staining. Results The number of fibroblasts, neutrophils and macrophages was similar among all subgroups. There was a higher lymphocyte reaction in the 30-day meshed group (p = 0.003). Giant cell reaction, granulation tissue and neoangiogenesis were similar among the subgroups. Synovial metaplasia was milder at 90-day in the unmeshed (p = 0.002) and meshed group (p < 0.001). Capsular thickness was significantly greater in the meshed samples (30-day p < 0.001 and 90-day p < 0.001). There was a similar amount of collagen types I and III in both groups. Conclusions The mesh-covered implants produced capsules similar to the microtextured ones when analyzing inflammatory variables. Synovial metaplasia was milder at 90 than at 30 days, and the capsular thickness was significantly greater in the meshed group. A similar amount of collagen types I and III was observed. Due to these characteristics, the mesh coverage did not seem to significantly affect the local inflammatory activity.


Assuntos
Animais , Feminino , Ratos , Silicones , Implantes de Mama/efeitos adversos , Poliésteres , Telas Cirúrgicas/efeitos adversos , Cápsulas , Colágeno , Ratos Wistar
3.
Acta cir. bras. ; 31(12): 774-782, Dec. 2016. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-20988

Resumo

PURPOSE:To assess the capsules formed by silicone implants coated with polyurethane foam and with a textured surface.METHODS:Sixty-four Wistar albinus rats were divided into two groups of 32 each using polyurethane foam and textured surface. The capsules around the implants were analyzed for 30, 50, 70 and 90 days. Were analyzed the following parameters: foreign body reaction, granulation tissue, presence of myofibroblasts, neoangiogenesis, presence of synovial metaplasia, capsular thickness, total area and collagen percentage of type I and III, in capsules formed around silicone implants in both groups.RESULTS:The foreign body reaction was only present in the four polyurethane subgroups. The formation of granulation tissue and the presence of myofibroblasts were higher in the four polyurethane subgroups. Regarding to neoangiogenesis and synovial metaplasia, there was no statistical difference between the groups. Polyurethane group presented (all subgroups) a greater capsule thickness, a smaller total area and collagen percentage of type I and a higher percentage area of type III, with statistical difference.CONCLUSION:The use of polyurethane-coated implants should be stimulated by the long-term results in a more stable capsule and a lower incidence of capsular contracture, despite developing a more intense and delayed inflammatory reaction in relation to implants with textured surface.(AU)


Assuntos
Animais , Feminino , Ratos , Silicones/análise , Silicones/uso terapêutico , Poliuretanos , Contratura Capsular em Implantes/veterinária , Mamoplastia/veterinária , Implante Mamário/veterinária , Implante Mamário/efeitos adversos , Ratos Wistar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA