Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Arq. bras. med. vet. zootec. (Online) ; 75(4): 571-590, July-Aug. 2023. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1447355

Resumo

The present study aimed to evaluate and compare the palmar and plantar digital arteries of 10 horses and 10 mules through B-mode and spectral Doppler ultrasound. Likewise, compare the plantar arteries of the pelvic limbs with the palmar arteries of the thoracic limbs, in addition to verifying the differences of the digital arteries in the contralateral limbs (right and left) in horses and mules using B-mode and spectral Doppler ultrasonography. The evaluated parameters were the diameter and the intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI), peak of systolic velocity (pSV), final diastolic velocity (fDV) and mean velocity (MV) of the lateral and medial palmar and plantar arteries digital in healthy horses and mules. The horses presented higher diameters values, IMT, pSV, fDV and MV in comparison to the mules. The variables RI and PI also presented differences between horses and mules. Also, both species showed higher values in the variables of B-mode and Doppler ultrasonography in the thoracic limbs. Differences were also detected in the comparison between the limb sides (right and left) in the two modalities. The B-Mode and spectral Doppler ultrasound techniques are viable tools to identify differences in the palmar and plantar digital arteries in healthy horses and mules, highlight the differences between the thoracic and pelvic limbs and their respective sides (right and left) as well.


O presente estudo teve como objetivo avaliar e comparar as artérias digitais palmares e plantares de 10 equinos e 10 muares, por meio de ultrassom modo B e Doppler espectral. Da mesma forma, buscou-se comparar as artérias plantares dos membros pélvicos com as artérias palmares dos membros torácicos, além de se verificarem as diferenças das artérias digitais nos membros contralaterais (direito e esquerdo) em equinos e mulas, por meio de ultrassonografia modo B e Doppler espectral. Os parâmetros avaliados foram o diâmetro e a espessura médio-intimal (EMI), o índice de resistividade (IR), o índice de pulsatilidade (IP), o pico de velocidade sistólica (pVS), a velocidade diastólica final (VDf) e a velocidade média (VM) das artérias palmares e plantares lateral e medial digitais em equinos e muares sadios. Os equinos apresentaram maiores valores de diâmetros, EMI, pVS, VDf e VM em comparação aos muares. As variáveis IR e IP também apresentaram diferenças entre equinos e muares. Cavalos e mulas apresentaram maiores valores nas variáveis de ultrassonografia modo B e Doppler nos membros torácicos. Também foram detectadas diferenças na comparação entre os lados dos membros (direito e esquerdo) nas duas modalidades. As técnicas de ultrassom modo-B e Doppler espectral são ferramentas viáveis para identificar diferenças nas artérias digitais palmares e plantares em equinos e muares saudáveis, bem como para destacar as diferenças entre os membros torácicos e pélvicos e seus respectivos lados (direito e esquerdo).


Assuntos
Animais , Artérias , Ultrassonografia Doppler/veterinária , Cavalos , Locomoção
2.
Arq. bras. med. vet. zootec. (Online) ; 72(2): 419-430, Mar./Apr. 2020. ilus, tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-1128360

Resumo

A ultrassonografia convencional e o Doppler espectral nas artérias carótidas comuns em equinos e muares são considerados escassos, diferentemente do que ocorre na medicina humana. Este trabalho propôs comparar as artérias carótidas comuns de equinos e muares por ultrassonografia modo-B e Doppler espectral, além de verificar as diferenças dessas variáveis entre os gêneros desses animais e a relação com a massa corpórea. Foram avaliados os seguintes parâmetros: massa corpórea, diâmetros das artérias, espessura da camada íntima-média (EIM), índice de resistividade (IR), índice de pulsatilidade (IP), velocidade sistólica (VS), velocidade diastólica (VD) e velocidade média (VM). Salvo a massa corpórea, esses parâmetros foram obtidos de três regiões (cranial, médio e caudal) e submetidos à análise conjuntamente. Os diâmetros das artérias carótidas comuns são diferentes entre equinos e muares, com valores menores nos equinos. O IR, o IP, a VS e a VM diferiram entre equinos e muares, sendo maiores nos equinos, e a VD superior nos muares. Não foi observada diferença das variáveis do modo-B e Doppler entre gêneros nos equinos, diferentemente dos muares, cujos machos apresentaram valores maiores do diâmetro, do IR e do IP, mas menores da VS e da VM. A massa corpórea não influenciou as variáveis do modo-B, independentemente do gênero, mas apresenta correlação significativa nas variáveis do modo Doppler. As artérias carótidas comuns de equinos e muares são diferentes pelos exames ultrassonográficos modo-B e Doppler espectral. O gênero não influencia no modo-B e no Doppler nos equinos, porém influencia parcialmente nos muares. A massa corpórea de equinos e de muares, independentemente do gênero, não tem associação com as variáveis do modo-B, apenas com o Doppler.(AU)


Conventional ultrasound and spectral Doppler in the common carotid arteries in horses and mules are considered scarce, different from human medicine. The aim of this study was to compare the common carotid arteries of horses and mules by B-mode ultrasonography and spectral Doppler ultrasonography, as well as to verify the differences of these variables between their genders and the relation with body mass. The following parameters were evaluated: body mass, artery diameter, intima-media thickness (EIM), resistivity index (IR), pulsatility index (IP), systolic velocity (VS), diastolic velocity (VD) and average velocity (VM). Besides the body mass, the other variables were obtained from three regions (cranial, medium and caudal) and analyzed together. The diameters of the common carotid arteries are different between horses and mules, being smaller in horses. The IR, IP, VS and VM differed between horses and mules, being higher in the horses, but the VD was higher in mules. No difference in the variables in B-mode and Doppler between gender were observed in horses, different from mules, in which the diameters, IR and IP values were higher in males and the VS and VM was higher in females. Body mass did not influence B-Mode, both for horses and mules. A significant correlation was observed for Doppler. The common carotid arteries of horses and mules are different by ultrasound scans B-mode and spectral Doppler. Gender does not influence the B-Mode and Doppler variables in horses, but can in mules. The body mass of horses and mules, regardless of gender, is not associated with B-mode variables, but with Doppler variables.(AU)


Assuntos
Animais , Artérias Carótidas/fisiologia , Artérias Carótidas/diagnóstico por imagem , Equidae/anatomia & histologia , Cavalos/anatomia & histologia , Pressão Sanguínea/fisiologia , Pesos e Medidas Corporais/veterinária , Ultrassonografia/veterinária , Ultrassonografia Doppler/veterinária
3.
Arq. bras. med. vet. zootec. (Online) ; 72(2): 419-430, Mar./Apr. 2020. ilus, tab
Artigo em Português | VETINDEX | ID: vti-29639

Resumo

A ultrassonografia convencional e o Doppler espectral nas artérias carótidas comuns em equinos e muares são considerados escassos, diferentemente do que ocorre na medicina humana. Este trabalho propôs comparar as artérias carótidas comuns de equinos e muares por ultrassonografia modo-B e Doppler espectral, além de verificar as diferenças dessas variáveis entre os gêneros desses animais e a relação com a massa corpórea. Foram avaliados os seguintes parâmetros: massa corpórea, diâmetros das artérias, espessura da camada íntima-média (EIM), índice de resistividade (IR), índice de pulsatilidade (IP), velocidade sistólica (VS), velocidade diastólica (VD) e velocidade média (VM). Salvo a massa corpórea, esses parâmetros foram obtidos de três regiões (cranial, médio e caudal) e submetidos à análise conjuntamente. Os diâmetros das artérias carótidas comuns são diferentes entre equinos e muares, com valores menores nos equinos. O IR, o IP, a VS e a VM diferiram entre equinos e muares, sendo maiores nos equinos, e a VD superior nos muares. Não foi observada diferença das variáveis do modo-B e Doppler entre gêneros nos equinos, diferentemente dos muares, cujos machos apresentaram valores maiores do diâmetro, do IR e do IP, mas menores da VS e da VM. A massa corpórea não influenciou as variáveis do modo-B, independentemente do gênero, mas apresenta correlação significativa nas variáveis do modo Doppler. As artérias carótidas comuns de equinos e muares são diferentes pelos exames ultrassonográficos modo-B e Doppler espectral. O gênero não influencia no modo-B e no Doppler nos equinos, porém influencia parcialmente nos muares. A massa corpórea de equinos e de muares, independentemente do gênero, não tem associação com as variáveis do modo-B, apenas com o Doppler.(AU)


Conventional ultrasound and spectral Doppler in the common carotid arteries in horses and mules are considered scarce, different from human medicine. The aim of this study was to compare the common carotid arteries of horses and mules by B-mode ultrasonography and spectral Doppler ultrasonography, as well as to verify the differences of these variables between their genders and the relation with body mass. The following parameters were evaluated: body mass, artery diameter, intima-media thickness (EIM), resistivity index (IR), pulsatility index (IP), systolic velocity (VS), diastolic velocity (VD) and average velocity (VM). Besides the body mass, the other variables were obtained from three regions (cranial, medium and caudal) and analyzed together. The diameters of the common carotid arteries are different between horses and mules, being smaller in horses. The IR, IP, VS and VM differed between horses and mules, being higher in the horses, but the VD was higher in mules. No difference in the variables in B-mode and Doppler between gender were observed in horses, different from mules, in which the diameters, IR and IP values were higher in males and the VS and VM was higher in females. Body mass did not influence B-Mode, both for horses and mules. A significant correlation was observed for Doppler. The common carotid arteries of horses and mules are different by ultrasound scans B-mode and spectral Doppler. Gender does not influence the B-Mode and Doppler variables in horses, but can in mules. The body mass of horses and mules, regardless of gender, is not associated with B-mode variables, but with Doppler variables.(AU)


Assuntos
Animais , Artérias Carótidas/fisiologia , Artérias Carótidas/diagnóstico por imagem , Equidae/anatomia & histologia , Cavalos/anatomia & histologia , Pressão Sanguínea/fisiologia , Pesos e Medidas Corporais/veterinária , Ultrassonografia/veterinária , Ultrassonografia Doppler/veterinária
4.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1419-1425, nov.-dez. 2017. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-909829

Resumo

Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes.(AU)


A radioterapia é uma modalidade que tem apresentando grandes avanços dentro da medicina veterinária pelo mundo. No Brasil, essa opção terapêutica é pouco realizada. O sucesso dessa modalidade depende de vários fatores, entre eles, o uso de acessórios adequados para a proteção e imobilização dos pacientes. Para a imobilização dos pequenos animais durante o tratamento, além da sedação e da anestesia, são utilizados acessórios imobilizadores semelhantes aos usados na radioterapia humana. Devido a isso, este trabalho teve como objetivo de apresentar propostas de acessórios de imobilização adaptados ao posicionamento de pequenos animais para o uso nos planejamentos radioterápicos. Para a sua realização, foram confeccionados acessórios e testados em um animal vivo simulando um planejamento radioterápico, os quais mostraram ser favoráveis ao uso nos posicionamento de pequenos animais submetidos à radioterapia e para sua implementação.(AU)


Assuntos
Animais , Feminino , Cães , Equipamentos e Provisões/veterinária , Imobilização/instrumentação , Imobilização/veterinária , Radioterapia/veterinária , Posicionamento do Paciente/veterinária
5.
Artigo em Inglês | VETINDEX | ID: vti-20176

Resumo

ABSTRACT Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes.


RESUMO A radioterapia é uma modalidade que tem apresentando grandes avanços dentro da medicina veterinária pelo mundo. No Brasil, essa opção terapêutica é pouco realizada. O sucesso dessa modalidade depende de vários fatores, entre eles, o uso de acessórios adequados para a proteção e imobilização dos pacientes. Para a imobilização dos pequenos animais durante o tratamento, além da sedação e da anestesia, são utilizados acessórios imobilizadores semelhantes aos usados na radioterapia humana. Devido a isso, este trabalho teve como objetivo de apresentar propostas de acessórios de imobilização adaptados ao posicionamento de pequenos animais para o uso nos planejamentos radioterápicos. Para a sua realização, foram confeccionados acessórios e testados em um animal vivo simulando um planejamento radioterápico, os quais mostraram ser favoráveis ao uso nos posicionamento de pequenos animais submetidos à radioterapia e para sua implementação.

6.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1419-1425, Nov.-Dez. 2017. ilus
Artigo em Inglês | VETINDEX | ID: vti-735022

Resumo

Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes.(AU)


A radioterapia é uma modalidade que tem apresentando grandes avanços dentro da medicina veterinária pelo mundo. No Brasil, essa opção terapêutica é pouco realizada. O sucesso dessa modalidade depende de vários fatores, entre eles, o uso de acessórios adequados para a proteção e imobilização dos pacientes. Para a imobilização dos pequenos animais durante o tratamento, além da sedação e da anestesia, são utilizados acessórios imobilizadores semelhantes aos usados na radioterapia humana. Devido a isso, este trabalho teve como objetivo de apresentar propostas de acessórios de imobilização adaptados ao posicionamento de pequenos animais para o uso nos planejamentos radioterápicos. Para a sua realização, foram confeccionados acessórios e testados em um animal vivo simulando um planejamento radioterápico, os quais mostraram ser favoráveis ao uso nos posicionamento de pequenos animais submetidos à radioterapia e para sua implementação.(AU)


Assuntos
Animais , Feminino , Cães , Equipamentos e Provisões/veterinária , Imobilização/instrumentação , Imobilização/veterinária , Radioterapia/veterinária , Posicionamento do Paciente/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA