Resumo
The goal of this research was to identify the frequency of the DEA 1.1 blood group in dogs from Sinop, Mato Grosso, Brazil, to help in the recruitment of compatible blood donors and recipients, and to assess the risk of transfusion reactions in previously sensitized dogs. Also, from the obtained results, to pick potential blood donors to compose a data bank. 195 adult dogs (1 to 4 years old), males and females, mongrel and purebred dogs were screened at the Veterinary Hospital of the University of Mato Grosso. The DEA 1.1 blood typing was performed using commercially available immunochromatographic strip for DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, France). The results showed a general frequency of 65% for DEA 1.1 positive dogs (n = 126) and 35% for DEA 1 negative dogs (n = 69). The general risk of sensitization of a DEA 1 negative dog following a first transfusion with DEA 1.1 positive blood was 23%, while the risk of this sensitized recipient to receive DEA 1.1 positive blood in a second transfusion and to develop an acute hemolytic reaction was calculated to be 5%. The blood typing of the dogs allowed their classification as DEA 1 typed blood donors, in a preliminary data bank, and also ensured the safety of blood transfusions.
Objetivou-se identificar a frequência do grupo sanguíneo DEA 1.1 em cães de Sinop, Mato Grosso, Brasil, para auxiliar a seleção de doadores e receptores de sangue compatíveis e, adicionalmente, avaliar o risco de reações transfusionais em cães sensibilizados. Além disso, a partir dos resultados obtidos, selecionar potenciais doadores de sangue para compor um banco de dados. Um total de 195 cães adultos (de 1 a 4 anos de idade), machos e fêmeas, mestiços e puros, que nunca haviam recebido transfusões de sangue, foram triados no Hospital Veterinário da Universidade do Mato Grosso. A tipagem sanguínea DEA 1.1 foi realizada utilizando-se ensaio imunocromatográfico comercialmente disponível para DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, França). Os resultados demonstraram uma frequência geral de 65% para cães DEA 1.1 positivos (n = 126) e 35% para cães DEA 1 negativos (n = 69). O risco geral de sensibilização de cães DEA 1 negativos após uma primeira transfusão com sangue DEA 1.1 positivo foi calculado em 23%, enquanto o risco deste receptor sensibilizado receber sangue DEA 1.1 positivo em uma segunda transfusão e desenvolver uma reação hemolítica aguda foi calculado em 5%. A tipagem sanguínea dos cães permitiu sua inserção como doadores de sangue tipados para o grupo DEA 1 em um banco de dados preliminar e garantiu a segurança das transfusões de sangue.
Assuntos
Animais , Cães , Sangue/imunologia , Doadores de Sangue , Antígenos de Grupos Sanguíneos/análise , Transfusão de Sangue/veterinária , Tipagem e Reações Cruzadas Sanguíneas/veterinária , Cães/sangue , Reação Transfusional/veterináriaResumo
Objetivou-se identificar a frequência do grupo sanguíneo DEA 1.1 em cães de Sinop, Mato Grosso, Brasil, para auxiliar a seleção de doadores e receptores de sangue compatíveis e, adicionalmente, avaliar o risco de reações transfusionais em cães sensibilizados. Além disso, a partir dos resultados obtidos, selecionar potenciais doadores de sangue para compor um banco de dados. Um total de 195 cães adultos (de 1 a 4 anos de idade), machos e fêmeas, mestiços e puros, que nunca haviam recebido transfusões de sangue, foram triados no Hospital Veterinário da Universidade do Mato Grosso. A tipagem sanguínea DEA 1.1 foi realizada utilizando-se ensaio imunocromatográfico comercialmente disponível para DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, França). Os resultados demonstraram uma frequência geral de 65% para cães DEA 1.1 positivos (n = 126) e 35% para cães DEA 1 negativos (n = 69). O risco geral de sensibilização de cães DEA 1 negativos após uma primeira transfusão com sangue DEA 1.1 positivo foi calculado em 23%, enquanto o risco deste receptor sensibilizado receber sangue DEA 1.1 positivo em uma segunda transfusão e desenvolver uma reação hemolítica aguda foi calculado em 5%. A tipagem sanguínea dos cães permitiu sua inserção como doadores de sangue tipados para o grupo DEA 1 em um banco de dados preliminar e garantiu a segurança das transfusões de sangue.
The goal of this research was to identify the frequency of the DEA 1.1 blood group in dogs from Sinop, Mato Grosso, Brazil, to help in the recruitment of compatible blood donors and recipients, and to assess the risk of transfusion reactions in previously sensitized dogs. Also, from the obtained results, to pick potential blood donors to compose a data bank. 195 adult dogs (1 to 4 years old), males and females, mongrel and purebred dogs were screened at the Veterinary Hospital of the University of Mato Grosso. The DEA 1.1 blood typing was performed using commercially available immunochromatographic strip for DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, France). The results showed a general frequency of 65% for DEA 1.1 positive dogs (n = 126) and 35% for DEA 1 negative dogs (n = 69). The general risk of sensitization of a DEA 1 negative dog following a first transfusion with DEA 1.1 positive blood was 23%, while the risk of this sensitized recipient to receive DEA 1.1 positive blood in a second transfusion and to develop an acute hemolytic reaction was calculated to be 5%. The blood typing of the dogs allowed their classification as DEA 1 typed blood donors, in a preliminary data bank, and also ensured the safety of blood transfusions.(AU)
Assuntos
Animais , Cães , Cães/sangue , Antígenos de Grupos Sanguíneos/análise , Reação Transfusional/veterináriaResumo
Objetivou-se identificar a frequência do grupo sanguíneo DEA 1.1 em cães de Sinop, Mato Grosso, Brasil, para auxiliar a seleção de doadores e receptores de sangue compatíveis e, adicionalmente, avaliar o risco de reações transfusionais em cães sensibilizados. Além disso, a partir dos resultados obtidos, selecionar potenciais doadores de sangue para compor um banco de dados. Um total de 195 cães adultos (de 1 a 4 anos de idade), machos e fêmeas, mestiços e puros, que nunca haviam recebido transfusões de sangue, foram triados no Hospital Veterinário da Universidade do Mato Grosso. A tipagem sanguínea DEA 1.1 foi realizada utilizando-se ensaio imunocromatográfico comercialmente disponível para DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, França). Os resultados demonstraram uma frequência geral de 65% para cães DEA 1.1 positivos (n = 126) e 35% para cães DEA 1 negativos (n = 69). O risco geral de sensibilização de cães DEA 1 negativos após uma primeira transfusão com sangue DEA 1.1 positivo foi calculado em 23%, enquanto o risco deste receptor sensibilizado receber sangue DEA 1.1 positivo em uma segunda transfusão e desenvolver uma reação hemolítica aguda foi calculado em 5%. A tipagem sanguínea dos cães permitiu sua inserção como doadores de sangue tipados para o grupo DEA 1 em um banco de dados preliminar e garantiu a segurança das transfusões de sangue.
The goal of this research was to identify the frequency of the DEA 1.1 blood group in dogs from Sinop, Mato Grosso, Brazil, to help in the recruitment of compatible blood donors and recipients, and to assess the risk of transfusion reactions in previously sensitized dogs. Also, from the obtained results, to pick potential blood donors to compose a data bank. 195 adult dogs (1 to 4 years old), males and females, mongrel and purebred dogs were screened at the Veterinary Hospital of the University of Mato Grosso. The DEA 1.1 blood typing was performed using commercially available immunochromatographic strip for DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, France). The results showed a general frequency of 65% for DEA 1.1 positive dogs (n = 126) and 35% for DEA 1 negative dogs (n = 69). The general risk of sensitization of a DEA 1 negative dog following a first transfusion with DEA 1.1 positive blood was 23%, while the risk of this sensitized recipient to receive DEA 1.1 positive blood in a second transfusion and to develop an acute hemolytic reaction was calculated to be 5%. The blood typing of the dogs allowed their classification as DEA 1 typed blood donors, in a preliminary data bank, and also ensured the safety of blood transfusions.
Assuntos
Animais , Cães , Antígenos de Grupos Sanguíneos/análise , Cães/sangue , Reação Transfusional/veterináriaResumo
The dog erythrocyte antigen 1 (DEA 1) is the most immunogenic blood group in dogs, and blood transfusions may trigger some undesirable effects in veterinary patients, which are directly associated with incompatible transfusions. The present study aimed to investigate the frequency of positive DEA 1 blood group in blood donor dogs from a blood bank in Salvador, Bahia, Brazil, and also to calculate the risk of managing incompatible blood in both first and second transfusion. A number of 203 dogs of different breeds, aged between 1 and 8 years, weighing 28 kg, with no degree of kinship and of both sexes in Salvador - BA, Brazil were evaluated to investigate the blood type DEA 1 frequency, by means of chromatography and flow cytometry tests for blood typing. The risk of incompatible blood transfusion in either a first or a second transfusion was also calculated. The frequency of the DEA 1 group ranged from 0% to 100% in various breeds, but with a mean positivity of 62.07% (126/203). And the lowest risk of an DEA 1 negative animal receiving DEA 1 positive blood within the group of animals evaluated was 0.92% at a first transfusion; and the risk of the same animal receiving incompatible blood for the DEA group 1 in the second transfusion was 0.008%. The highest risk of an DEA 1 negative animal receiving DEA 1 positive blood from these animals was 69.12%; and the risk of receiving incompatible blood for DEA 1 was 47.77%. In conclusion, the frequency of the DEA 1 group varied between the studied breeds and the risk of incompatible blood transfusions varies according to donor and recipiente breeds, but this can be overridden if blood typing tests are performed along with the cross-reaction test for compatibility.
O antígeno eritrocitário canino 1 (AEC 1) é o grupo sanguíneo mais imunogênico em cães, podendo as transfusões sanguíneas desencadearem alguns efeitos indesejáveis nos pacientes veterinários. Estes estão diretamente associados à transfusões incompatíveis. O presente trabalho teve como objetivo estudar a frequência do grupo sanguíneo AEC 1 em cães doadores de sangue de um banco de sangue de Salvador-BA, Brasil, e calcular o risco de administrar sangue incompatível tanto em uma primeira quanto em uma segunda transfusão. Foram avaliados 203 cães de diversas raças, de ambos os sexos, com idade entre 1 e 8 anos, peso a partir de 28 kg, sem nenhum grau de parentesco originários de Salvador BA, Brasil, para pesquisa da frequência do tipo sanguíneo AEC 1, por meio de testes de imunocromatografia e citometria de fluxo para tipagem sanguínea. E calculado o risco de transfusão sanguínea incompatível tanto em uma primeira como em uma segunda transfusão. A frequência do grupo AEC 1 variou entre as raças estudadas de 0% a 100%, porém com uma positividade média de 62,07% (126/203). O menor risco de um animal AEC 1 negativo receber sangue AEC 1 positivo, dentro do grupo dos animais avaliados foi de 0,92% em uma primeira transfusão e o risco do mesmo animal receber sangue incompatível para o gruo AEC 1 na segunda transfusão foi de 0,008%. Quanto ao maior risco de um animal AEC 1 negativo receber sangue AEC 1 positivo destes animais foi de 69,12% e o risco do mesmo receber sangue incompatível para o AEC 1 foi de 47,77%. A frequência do grupo AEC 1 variou entre as raças estudadas e o risco de transfusões incompatíveis variou de acordo com as raças doadoras e receptoras, mas esse risco pode ser anulado se sempre forem realizados os testes para tipagem sanguínea junto com a prova de reação cruzada para compatibilidade.
Assuntos
Animais , Cães , Transfusão de Sangue/veterinária , Cães/sangue , Índices de Eritrócitos/imunologiaResumo
O presente trabalho estudou a frequência dos grupos sanguíneos identificados como antígenos eritrocitários caninos (AEC) 1, 1.1 e 7 em cães da região metropolitana da cidade de São Paulo-SP, Brasil, e calculou o risco de administração de sangue incompatível tanto em uma primeira quanto em uma segunda transfusão. Para tanto, 300 cães não aparentados foram divididos igualmente em seis grupos de acordo com as raças: Pastor Alemão (PA); Rottweiler (R); Poodle (P); Cocker Spaniel Inglês (CS); raças definidas diversas (RDD) e mestiços (M). Foi avaliada a relação entre a frequência dos AEC e os grupos raciais. A frequência geral de AEC 1 na população foi de 71% (AEC 1.1 53,35%) e houve variações de acordo com as raças: PA- 32% (AEC 1.1 20%), R- 98% (1.1 80%), P- 76% (1.1 54%), CS- 84% (1.1 50%), RDD- 62% (1.1 56%) e M- 74% (1.1 60%). A frequência geral de AEC 7 foi de 39,33% e não houve diferenças significativas entre as raças. O risco de um cão negativo para o AEC 1 receber sangue positivo foi de 0,6 a 66,6% em uma primeira transfusão e de 0,21 a 65,3% do mesmo cão receber sangue incompatível em uma segunda transfusão. O risco quanto ao AEC 7 foi de 23,86% na primeira transfusão e 9,4% numa segunda transfusão. Este trabalho concluiu que houve variação na frequência de AEC1 e AEC 1.1, mas não quanto ao AEC 7 entre raças. Esta variação na porcentagem de animais positivos quanto ao AEC 1 se refletiu na grande variação no risco de uso de sangue incompatível. Portanto, conhecer a frequência dos AEC na população tem impacto direto no manejo entre cães doadores e receptores, mas a utilização conjunta de teste de tipagem sanguínea e reação cruzada reduz a possibilidade de transfusão de sangue incompatível.(AU)
It was investigated the frequency of blood groups identified as Dog Erythrocyte Antigens (DEA) 1, 1.1 and 7 dogs in the metropolitan region of São Paulo-SP, Brazil, and calculated the risk of administering incompatible blood in both first and second transfusion. For both, 300 unrelated dogs were equally divided into six groups according to the breeds: German Shepherd (GS), Rottweiler (R) Poodle (P), Cocker Spaniel (CS); defined several races (DSR), mongrel dogs (M). It was evaluated the relationship between the frequency of AEC and racial groups. The overall frequency of DEA 1 in population was 71% (DEA 1.1 53.35%) and there were variations according to the breeds: GS- 32% (DEA 1.1 20%), R 98% (1.1 80%) P 76% (1.1 54%), CS-84% (1.1 50%), DSR- 62% (1.1 56%) and M 74% (1.1 60%). The overall frequency of BCE 7 was 39.33%, and there were no significant differences between the breeds. The risk of a dog negative DEA receiving 1 positive blood was 0.6 to 66.6% in the first transfusion and 0.21 to 65.3% from the same animal dog receiving incompatible blood transfusion in a second. The risk of the DEA 7 was 23.86% in the first transfusion and 9.4% in a second transfusion. This study concluded that there was variation in the frequency of DEA 1 and 1.1, but not on the DEA 7 between races. This variation in the percentage of positive animals to DEA 1 was reflected in the large variation in the risk of use of incompatible blood. Therefore, knowing the frequency of the DEA in the population has a direct impact on handling dogs between donors and recipients, but the joint use of testing blood typing and cross-reactivity reduces the possibility of incompatible blood transfusion.(AU)
Assuntos
Animais , Policitemia , Cães/classificação , Transfusão de Sangue/métodosResumo
The dog erythrocyte antigen 1 (DEA 1) is the most immunogenic blood group in dogs, and blood transfusions may trigger some undesirable effects in veterinary patients, which are directly associated with incompatible transfusions. The present study aimed to investigate the frequency of positive DEA 1 blood group in blood donor dogs from a blood bank in Salvador, Bahia, Brazil, and also to calculate the risk of managing incompatible blood in both first and second transfusion. A number of 203 dogs of different breeds, aged between 1 and 8 years, weighing 28 kg, with no degree of kinship and of both sexes in Salvador - BA, Brazil were evaluated to investigate the blood type DEA 1 frequency, by means of chromatography and flow cytometry tests for blood typing. The risk of incompatible blood transfusion in either a first or a second transfusion was also calculated. The frequency of the DEA 1 group ranged from 0% to 100% in various breeds, but with a mean positivity of 62.07% (126/203). And the lowest risk of an DEA 1 negative animal receiving DEA 1 positive blood within the group of animals evaluated was 0.92% at a first transfusion; and the risk of the same animal receiving incompatible blood for the DEA group 1 in the second transfusion was 0.008%. The highest risk of an DEA 1 negative animal receiving DEA 1 positive blood from these animals was 69.12%; and the risk of receiving inc
O antígeno eritrocitário canino 1 (AEC 1) é o grupo sanguíneo mais imunogênico em cães, podendo as transfusões sanguíneas desencadearem alguns efeitos indesejáveis nos pacientes veterinários. Estes estão diretamente associados à transfusões incompatíveis. O presente trabalho teve como objetivo estudar a frequência do grupo sanguíneo AEC 1 em cães doadores de sangue de um banco de sangue de Salvador-BA, Brasil, e calcular o risco de administrar sangue incompatível tanto em uma primeira quanto em uma segunda transfusão. Foram avaliados 203 cães de diversas raças, de ambos os sexos, com idade entre 1 e 8 anos, peso a partir de 28 kg, sem nenhum grau de parentesco originários de Salvador BA, Brasil, para pesquisa da frequência do tipo sanguíneo AEC 1, por meio de testes de imunocromatografia e citometria de fluxo para tipagem sanguínea. E calculado o risco de transfusão sanguínea incompatível tanto em uma primeira como em uma segunda transfusão. A frequência do grupo AEC 1 variou entre as raças estudadas de 0% a 100%, porém com uma positividade média de 62,07% (126/203). O menor risco de um animal AEC 1 negativo receber sangue AEC 1 positivo, dentro do grupo dos animais avaliados foi de 0,92% em uma primeira transfusão e o risco do mesmo animal receber sangue incompatível para o gruo AEC 1 na segunda transfusão foi de 0,008%. Quanto ao maior risco de um animal AEC 1 negativo rece