Resumo
This review will focus on the main findings of our experiments that used B-mode and color-Doppler ultrasonography during the preovulatory period to study the morphological and blood flow/perfusion changes of the preovulatory follicle in mares. The topics to be addressed herein will be: ultrasonographic characteristics of the preovulatory follicle; B-mode echotextural changes of the follicle wall; blood flow and perfusion changes of the follicle wall; signs of impending ovulation; prediction of impending ovulation; types of preovulatory follicle outcomes such as ovulation, septated evacuation, hemorrhagic anovulatory follicle, and atresia; follicle blood flow during evacuation; early corpus luteum blood flow; and vascularity of the preovulatory follicle versus fertility.(AU)
This review will focus on the main findings of our experiments that used B-mode and color-Doppler ultrasonography during the preovulatory period to study the morphological and blood flow/perfusion changes of the preovulatory follicle in mares. The topics to be addressed herein will be: ultrasonographic characteristics of the preovulatory follicle; B-mode echotextural changes of the follicle wall; blood flow and perfusion changes of the follicle wall; signs of impending ovulation; prediction of impending ovulation; types of preovulatory follicle outcomes such as ovulation, septated evacuation, hemorrhagic anovulatory follicle, and atresia; follicle blood flow during evacuation; early corpus luteum blood flow; and vascularity of the preovulatory follicle versus fertility.(AU)
Assuntos
Animais , Ultrassonografia/veterinária , Ovulação , Fertilidade , Folículo Ovariano , Evacuação EstratégicaResumo
This review will focus on the main findings of our experiments that used B-mode and color-Doppler ultrasonography during the preovulatory period to study the morphological and blood flow/perfusion changes of the preovulatory follicle in mares. The topics to be addressed herein will be: ultrasonographic characteristics of the preovulatory follicle; B-mode echotextural changes of the follicle wall; blood flow and perfusion changes of the follicle wall; signs of impending ovulation; prediction of impending ovulation; types of preovulatory follicle outcomes such as ovulation, septated evacuation, hemorrhagic anovulatory follicle, and atresia; follicle blood flow during evacuation; early corpus luteum blood flow; and vascularity of the preovulatory follicle versus fertility.
This review will focus on the main findings of our experiments that used B-mode and color-Doppler ultrasonography during the preovulatory period to study the morphological and blood flow/perfusion changes of the preovulatory follicle in mares. The topics to be addressed herein will be: ultrasonographic characteristics of the preovulatory follicle; B-mode echotextural changes of the follicle wall; blood flow and perfusion changes of the follicle wall; signs of impending ovulation; prediction of impending ovulation; types of preovulatory follicle outcomes such as ovulation, septated evacuation, hemorrhagic anovulatory follicle, and atresia; follicle blood flow during evacuation; early corpus luteum blood flow; and vascularity of the preovulatory follicle versus fertility.
Assuntos
Animais , Fertilidade , Folículo Ovariano , Ovulação , Ultrassonografia/veterinária , Evacuação EstratégicaResumo
Devido à carência de informações sobre o tema e à ausência de estudos que confrontem as técnicas de biópsia hepática em ovinos, foi desenvolvido um estudo comparativo entre oito técnicas de biópsia nesta espécie. Neste estudo foram utilizadas oito borregas (17,95kg ± 2,71) mestiças (Santa Inês) em procedimentos seriados por oito semanas consecutivas e avaliados os aspectos clínicos, os achados de patologia clínica, o peso das amostras hepáticas, a qualidade histológica, o número de veias centrolobulares e espaços-porta e a presença de artefatos no corte histológico de amostras hepáticas obtidas através de seis técnicas percutâneas e duas técnicas videolaparoscópicas. Para as técnicas percutâneas empregaram-se dois tipos de agulhas, Menghini modificada (M) e Tru-cut semi-automática (T), combinadas com biópsias cegas, guiadas por ultra-sonografia (US) e monitoradas por videolaparoscopia (VL). No caso dos procedimentos vídeolaparoscópicos utilizaram-se pinça laparoscópica de biópsia Blakesley e método de ressecção de fragmento hepático por VL. Não foram observadas alterações hematológicas ou bioquímicas relevantes e as manifestações clínicas detectadas foram leves e transitórias. De uma forma geral, o uso da US e da VL nas biópsias percutâneas não resultou em acréscimo significativo do peso e da qualidade histológica das amostras hepáticas, porém as técnicas videolaparoscópicas permitiram acesso mais amplo ao fígado do que as técnicas percutâneas. A qualidade das amostras recuperadas com ambas as técnicas VL foram equivalentes, entretanto o uso da técnica de ressecção permitiu a colheita de amostras de maior peso, mas determinou a formação de aderências perihepáticas. Verificaram-se maior dificuldade na recuperação de fragmentos, maior oscilação do peso e menor qualidade das amostras obtidas com o uso das agulhas M do que com o das agulhas T.(AU)
Due to lack of information about the subject and lack of studies that confront the techniques of liver biopsy in sheep, a comparative study between eight biopsy techniques in this species was developed. In this study, eight crossbred (Santa Inês) ewe lambs (17.95 kg ± 2.71) were used in serial procedures for eight consecutive weeks. Liver samples obtained through six percutaneous techniques and two videolaparoscopic techniques were analyzed. The clinical aspects, clinical pathological findings, hepatic sample weights, histology quality, number of centrilobular veins and portal spaces, and the presence of artifacts in the histology slices were recorded. For the percutaneous techniques, two types of needles were used, modified Menghini (M) and semi-automatic tru-cut (T). They were used in combinations with blind biopsies, guided by ultrasound (US) and monitored by video laparoscopy (VL) biopsies. In the videolaparoscopy procedures, Blakesley biopsy forceps and the method of liver fragment resection by VL were used. No relevant hematological or biochemical alterations were found and the clinical manifestations were slight and transitory. In a general way, the use of US and VL in percutaneous biopsies did not yield a significant improvement in weight and histology quality of the liver samples; however, the videolaparoscopic techniques allowed a wider access to the liver than the percutaneous techniques. The quality of the samples obtained through both VL techniques were equivalent; however, the resection technique enabled the collection of heavier samples, but determined the formation of perihepatic adherences. More difficulty in fragment retrieval, more fluctuation in weight and less quality were found in samples obtained with M needles when compared to T needles.(AU)
Assuntos
Animais , Técnicas e Procedimentos Diagnósticos/veterinária , Biópsia/instrumentação , Biópsia/veterinária , Ovinos , Laparoscopia , UltrassonografiaResumo
O objetivo deste experimento foi de avaliar a proporção de ossos, músculo e gordura em cordeiros puros e cruzados das raças Morada Nova, Santa Inês e Dorper, bem como a correlação das medidas de olho de lombo na carcaça e in vivo. Foram utilizados 24 cordeiros, terminados em confinamento até atingirem 35 kg e agrupados em 4 tratamentos: Morada Nova, Morada Nova cruzado com Dorper, Santa Inês e Santa Inês cruzado com Dorper. Antes do abate, foram realizadas avaliaçõs através da técnica de ultra-sonografia em tempo real para predição da área de olho-de-lombo (AOL) e espessura da camada de gordura subcutânea (ECG). As mesmas caracteristicas foram avaliadas na carcaça, que posteriormente foram seccionadas em duas meias carcaças, sendo a metade esquerda usada para a obtenção dos cortes cárneos: Pescoço, Paleta, Costela, Fralda, Carré descoberto, Carré coberto, Lombo e Pernil, os quais foram dissecados completamente. As fêmeas do grupo genético Morada Nova e Santa Inês cruzados carneiros da raça Dorper mostraram-se efetivos em melhorar a proporção e o peso de músculo. A seção HH da costela de cordeiros mostra-se adequada para avaliação da composição tecidual de cordeiros pois a proporção de músculo, osso e gordura na costela apresentaram correlação significativa com as respectivas proporções na carcaça, sendo uma alternativa mais prática e rápida nas avaliações de proporção dos constituintes em ovinos jovens. O grupo genético Dorper x Morada Nova apresentou quantidade de músculo similar com o grupo genético Dorper x Santa Inês, com quantidade superior de gordura e idade superior de abate.
The objective of this experiment was to evaluate the proportion of bones, meat and fat in lambs pure and crossed races Morada Nova, Santa Inês and Dorper, as well as the correlation of ribeye área (RA) measures in carcass and in vivo. A total of 24 lambs were kept in a confinement until they reached 35 kg, and after divided into four treatment: Morada Nova, Morada Nova crossed with Dorper, Santa Ines and Santa Ines crossed with Dorper. Before slaughter, were evaluations performed by ultrasonographic measurement in real time to predict RA and subcutaneous fat thickness (SFT). The same characteristics were evaluated in the carcass, which were subsequently sectioned into two half carcasses, with the left half used for obtaining the meat cuts: neck, palette, rib, flank steak, lamb loin chop without fat, lamb loin chop with fat, loin and leg of lamb, which were dissected completely. Females of genetic group Morada Nova and Santa Ines crossed with Dorper sheep showed significant improvement in the proportion and the weight of meat. The Hankins e Howe (HH) section of lambs proved to be adequate to evaluate the tissue composition of lambs because the proportion of meat, bone and fat in the rib was significantly correlated with the proportions in the carcass, and a more practical and fast alternative in the proportion of ratings the constituents in young sheep. The genetic group Dorper x Morada Nova showed similar amount of meat with the genetic group Dorper x Santa Inês, with higher amount of fat and the age of slaughter.
Resumo
An osteosarcoma involving the pelvis was diagnosed in a 9-year-old neutered Labrador bitch. The clinical signs manifested by the patient before surgical removal of the tumor included urinary difficulty, dyschezia, and inconstant non-weight-bearing on the hindlimbs. These signs were linked to the localization of the tumor, which was identified as a firm and painful mass of the size of an orange in the caudal abdomen. The favorable short term clinical results after surgery and carboplatin chemotherapy showed that the association of these approaches can be employed to manage discomfort inflicted by tumor and, therefore improve the quality of life of patient of bone cancer.(AU)
Diagnosticou-se um osteossarcoma pélvico em uma cadela da raça Labrador de nove anos. Os sinais clínicos manifestados pela paciente antes da remoção do tumor incluiam dificuldade urinária, disquezia e dificuldade de sustentação do trem posterior. Estes sinais estavam associados à localização do tumor, identificado como uma massa firme e dolorosa do tamanho de uma laranja à região caudal do abdômen. Os resultados clínicos favoráveis observados em curto prazo depois da instauração de tratamento cirúrgico e quimioterápico com carboplatina mostram que a associação dessas condutas pode ser empregada para diminuir o desconforto imposto pelo tumor e, portanto melhorar a qualidade de vida em pacientes com câncer ósseo.(AU)
Assuntos
Animais , Feminino , Neoplasias Pélvicas , Osteossarcoma , Tratamento Farmacológico , CãesResumo
Total hepatic perfusion by portal system and hepatic arteria as well as its respective average contributions, can be affected for several hepatic processes, such as diffuse liver disease, neoplasm and intrahepatic shunts. Blood flow exams of the liver vessels using Doppler ultrasonography, appeared as a viable, non-invasive and helpful diagnostic method for the hemoportal dynamic evaluation. There are two Doppler ultrasonographic modalities most frequently used in routine for evaluation of the abdominal vessels flow, spectral Doppler imaging and color-flow Doppler imaging. In chronic liver disease, alteration of hepatic complacency occurs because of either fibrosis or cirrhosis, bringing to vascular alterations which provoke an increase in portal pressure. The main indications for this exam are cases suspicious of portal hypertension. Portal hemodynamics is evaluated by measurements of the area, average speed, flow volume and portal vein congestion index. The objectives of this review are to describe the basic physical principles of Doppler ultrasonography and its use for evaluation of portal hemodynamics in dogs.
A perfusão total do fígado e suas contribuições relativas, pelo sistema portal e pela artéria hepática, podem estar alteradas por vários processos hepáticos, como doença hepato-celular difusa, neoplasia e shunts intra-hepáticos. O estudo do comportamento do fluxo sangüíneo nos vasos do fígado por meio da ultra-sonografia Doppler tem demonstrado que este é um método viável não-invasivo e de grande auxílio, principalmente na avaliação da hemodinâmica portal. São duas as modalidades de ultra-sonografia Doppler com maior aplicação na rotina para avaliação de fluxo nos vasos abdominais, o Doppler espectral e o Doppler colorido. Na doença hepática crônica, ocorre alteração da complacência hepática devido à fibrose ou à cirrose, as quais acarretam alterações vasculares, levando ao aumento da pressão venosa portal. As principais indicações desse exame são os casos em que há suspeita de hipertensão portal. A hemodinâmica portal é avaliada pela mensuração de sua área, da velocidade média, do volume de fluxo no vaso e do índice de congestão portal. Esta revisão de literatura tem como objetivo descrever os princípios físicos básicos da ultra-sonografia Doppler e sua aplicação na avaliação da hemodinâmica portal nos cães.
Resumo
Total hepatic perfusion by portal system and hepatic arteria as well as its respective average contributions, can be affected for several hepatic processes, such as diffuse liver disease, neoplasm and intrahepatic shunts. Blood flow exams of the liver vessels using Doppler ultrasonography, appeared as a viable, non-invasive and helpful diagnostic method for the hemoportal dynamic evaluation. There are two Doppler ultrasonographic modalities most frequently used in routine for evaluation of the abdominal vessels flow, spectral Doppler imaging and color-flow Doppler imaging. In chronic liver disease, alteration of hepatic complacency occurs because of either fibrosis or cirrhosis, bringing to vascular alterations which provoke an increase in portal pressure. The main indications for this exam are cases suspicious of portal hypertension. Portal hemodynamics is evaluated by measurements of the area, average speed, flow volume and portal vein congestion index. The objectives of this review are to describe the basic physical principles of Doppler ultrasonography and its use for evaluation of portal hemodynamics in dogs.
A perfusão total do fígado e suas contribuições relativas, pelo sistema portal e pela artéria hepática, podem estar alteradas por vários processos hepáticos, como doença hepato-celular difusa, neoplasia e shunts intra-hepáticos. O estudo do comportamento do fluxo sangüíneo nos vasos do fígado por meio da ultra-sonografia Doppler tem demonstrado que este é um método viável não-invasivo e de grande auxílio, principalmente na avaliação da hemodinâmica portal. São duas as modalidades de ultra-sonografia Doppler com maior aplicação na rotina para avaliação de fluxo nos vasos abdominais, o Doppler espectral e o Doppler colorido. Na doença hepática crônica, ocorre alteração da complacência hepática devido à fibrose ou à cirrose, as quais acarretam alterações vasculares, levando ao aumento da pressão venosa portal. As principais indicações desse exame são os casos em que há suspeita de hipertensão portal. A hemodinâmica portal é avaliada pela mensuração de sua área, da velocidade média, do volume de fluxo no vaso e do índice de congestão portal. Esta revisão de literatura tem como objetivo descrever os princípios físicos básicos da ultra-sonografia Doppler e sua aplicação na avaliação da hemodinâmica portal nos cães.
Resumo
Total hepatic perfusion by portal system and hepatic arteria as well as its respective average contributions, can be affected for several hepatic processes, such as diffuse liver disease, neoplasm and intrahepatic shunts. Blood flow exams of the liver vessels using Doppler ultrasonography, appeared as a viable, non-invasive and helpful diagnostic method for the hemoportal dynamic evaluation. There are two Doppler ultrasonographic modalities most frequently used in routine for evaluation of the abdominal vessels flow, spectral Doppler imaging and color-flow Doppler imaging. In chronic liver disease, alteration of hepatic complacency occurs because of either fibrosis or cirrhosis, bringing to vascular alterations which provoke an increase in portal pressure. The main indications for this exam are cases suspicious of portal hypertension. Portal hemodynamics is evaluated by measurements of the area, average speed, flow volume and portal vein congestion index. The objectives of this review are to describe the basic physical principles of Doppler ultrasonography and its use for evaluation of portal hemodynamics in dogs.
A perfusão total do fígado e suas contribuições relativas, pelo sistema portal e pela artéria hepática, podem estar alteradas por vários processos hepáticos, como doença hepato-celular difusa, neoplasia e shunts intra-hepáticos. O estudo do comportamento do fluxo sangüíneo nos vasos do fígado por meio da ultra-sonografia Doppler tem demonstrado que este é um método viável não-invasivo e de grande auxílio, principalmente na avaliação da hemodinâmica portal. São duas as modalidades de ultra-sonografia Doppler com maior aplicação na rotina para avaliação de fluxo nos vasos abdominais, o Doppler espectral e o Doppler colorido. Na doença hepática crônica, ocorre alteração da complacência hepática devido à fibrose ou à cirrose, as quais acarretam alterações vasculares, levando ao aumento da pressão venosa portal. As principais indicações desse exame são os casos em que há suspeita de hipertensão portal. A hemodinâmica portal é avaliada pela mensuração de sua área, da velocidade média, do volume de fluxo no vaso e do índice de congestão portal. Esta revisão de literatura tem como objetivo descrever os princípios físicos básicos da ultra-sonografia Doppler e sua aplicação na avaliação da hemodinâmica portal nos cães.
Resumo
The aim of the current study was to evaluate the resistivity index (RI) and pulsatility index (PI) of hepatic artery (HA) by Triplex Doppler in health adult dogs on pre and postprandial periods. The experimental group was formed by 14 mongrel dogs, 9 females and five males, weighing 6-19 kg and 4-16 kg, respectively. The animals were previously prepared, remaining 24 hours of starvation, and feeding with milk or pellet show food to perform posprandial analysis. The ultrasound PHILIPS HDI 4000 equipped with a micro convex transducer (5-8MHz) was used. The RI and PI measurements of HA were performed on tree times: T0 (pre-prandial period), T1 (30 minutes postprandial) and T2 (90 minutes postprandial). There are no statistical differences between T0 and T2 when compared RI and PI of HA. However, both indices were significantly diminished on T1 in relation with T0 and T2, which represents an increase of AH blood flow 30 min postprandial. The employment of HA Triplex Doppler improves the blood flow evaluation pre and posprandial and can be one important technique to establish comparative parameter to distinguish between hepatic metabolic homeostasis from different physiopathologics states. KEY WORDS: Dogs, hepatic artery, pulsatility index, resistivity index, ultrasound.
O objetivo deste trabalho foi avaliar por meio do triplex doppler as variações dos índices de resistividade (IR) e pulsatilidade (IP) da artéria hepática (AH) de cães adultos saudáveis em períodos pré e pós-prandiais. O grupo amostral foi composto por quatorze cães sem raça definida, sendo nove fêmeas e cinco machos com peso entre seis e dezenove quilos e quatro e dezesseis quilos, respectivamente. Previamente aos exames ultrassonográficos, os animais foram submetidos a 24 horas de jejum e, para os exames pós-prandiais, foram alimentados com leite ou ração comercial. Utilizou-se o ultrassom Philips HDI 4000, munido de um transdutor microconvexo (5-8MHz). Dividiram-se as mensurações dos IR e IP da AH em três tempos: T0 (período pré-prandial), T1 (trinta minutos pós-prandial) e T2 (noventa minutos pós-prandial). Não houve diferença estatística quando comparadas as médias de IR e IP da AH entre T0 e T2. No entanto, ambos os índices foram significativamente menores no T1 quando comparado com os outros períodos de análise, comprovando aumento de fluxo sanguíneo na AH trinta minutos pós-prandial. O uso do triplex doppler da AH possibilitou mensurações do fluxo sanguíneo pré e pós-prandial, sendo uma técnica importante para estabelecer parâmetros comparativos entre homeostasia metabólica e diferentes estados fisiopatológicos hepáticos.PALAVRAS-CHAVES: Artéria hepática, cães, índice de
Resumo
Este estudo objetivou estabelecer características morfológicas e endócrinas da dinâmica luteal de fêmeas nulíparas da raça Toggenburg, e avaliar a função luteal utilizando a análise de atributos de imagens ultrassonográficas. A dinâmica luteal foi acompanhada por ultrassonografia transretal. A ecotextura luteal foi determinada em um software próprio. Cada ponto da imagem (pixel) foi quantificado dentro de uma escala de cinza (0=preto e 255=branco). Os CLs foram primeiramente detectados no dia 5,00±0,19 (D0=estro), com área média de 0,63±0,07cm2 e aumentaram progressivamente (P<0,001) até o D9, atingindo uma área máxima de 1,26±0,08cm2. A concentração plasmática de P4 aumentou progressivamente até o D9, não apresentando aumento significativo até o momento da luteólise, e 24hs depois atingiu valores inferiores a 1 ng/mL. Diferentemente, a área luteal diminuiu de forma mais lenta e gradual. Houve uma correlação significativa (P<0,05) entre a área luteal e a concentração de P4 durante o processo de luteogênese e de luteólise (r=0,63 e r=0,50, respectivamente). As alterações morfológicas, histológicas e bioquímicas observadas no CL, durante o ciclo estral, refletiram sobre a ecotextura luteal. Houve uma correlação positiva (P<0,05) entre o valor médio dos pixels e a área luteal durante a luteogênese e luteólise (r=0,34 e r=0,26, respectivamente), assim como com a P4 (r=0,24 e r=0,37, respectivamente). Estas características demonstram que a dinâmica luteal em cabras Toggenburg segue padrões semelhantes às observadas em outras raças e outras espécies e que a quantificação do valor médio dos pixels apresenta um potencial para a avaliação da função luteal na espécie caprina
The purpose of this study was to establish morphological and endocrine characteristics of luteal dymanics in Nuliparous Toggenburg goats, and evaluate luteal function by using computer-assisted ultrasonographic image analysis. Luteal dynamics was conducted by transrectal ultrasonography. Luteal echotexture was determined with the use of customized software, in which each image dot (pixel) received a numeric value ranging from 0 (black) to 255 (white). Corpora lutea were first visualized on day 5.00±0.19 with a average area of 0.63±0.07 cm2, and progressively increased in size (P<0.001) until the day 9, when reached a maximum area of 1.26±0.08 cm2. Plasma progesterone also increased until day 9 and no significant increase was observed until luteolysis - it reached values below 1 ng/mL after 24 h. Differently, the luteal area decreased in size slowly and gradually. Significant correlation (P<0.05) between progesterone levels and luteal area was observed during the processes of luteogenesis and luteolysis (r = 0.63 and r = 0.50, respectively). Morphological, edocrinological and biochemical changes noticed in CL during the estrous cycle reflected on the luteal echotexture. Positive correlation (P<0.05) was observed between the mean pixel value and the luteal tissue area during luteogenesis and luteolysis (r = 0.34 e r = 0.26, respectively), and also between mean pixel value and plasma progesterone level (r = 0.24 e r = 0.37, respectively). These characteristics showed that the luteal dynamics in Toggenbur goats present patterns similar to those noticed in other goat breeds and species and that pixel value quantification plays a potential role for the luteal function evaluation in goats
Este estudio tuvo como objetivo establecer características morfológicas y endocrinas de la dinámica luteal de hembras nulíparas de raza Toggenburg, y evaluar la función luteal utilizando el análisis de atributos de imágenes ultrasonográficas. La dinámica luteal fue acompañada por ultrasonografía transrectal. La ecotextura luteal fue determinada en un software propio. Cada punto de la imagen (pixel) fue cuantificado según una escala gris (0=negro y 255=blanco). Los CLs fueron primeramente detectados en el día 5,00±0,19 (D0=estro), con área media de 0,63±0,07cm2 y aumentaron progresivamente (P<0,001) hasta el día D9, alcanzando área máxima de 1,26±0,08cm2. La concentración plasmática de P4 se incrementó progresivamente hasta el día D9, no presentando aumento significativo hasta el momento de la luteólisis, y tras 24hs alcanzó valores inferiores a 1 ng/mL. Diferentemente, el área luteal disminuyó de forma más lenta y gradual. Hubo una correlación significativa (P<0,05) entre el área luteal y la concentración de P4 durante el proceso de "luteogênese" y de luteólisis (r=0,63 y r=0,50, respectivamente). Las alteraciones morfológicas, histológicas y bioquímicas observadas en el CL durante el ciclo estral, reflejaron sobre la ecotextura luteal. Hubo una correlación positiva (P<0,05) entre el valor medio de los pixels y el área luteal durante la "luteogênese" y luteólisis (r=0,34 e r=0,26, respectivamente), así como con la P4 (r=0,24 e r=0,37, respectivamente). Estas características demuestran que la dinámica luteal en cabras Toggenburg sigue patrones semejantes a las observadas en otras razas y otras especies, y que la cuantificación del valor medio de los pixels presenta un potencial para la evaluación de la función luteal en la especie caprina
Assuntos
Animais , Cabras , Ciclo Estral/fisiologia , Fase Luteal , Progesterona , Ultrassonografia/efeitos adversos , Ultrassonografia/métodosResumo
A ultra-sonografia Doppler é um método relativamente recente dentro da rotina veterinária que fornece informações em tempo real da arquitetura vascular e dos aspectos hemodinâmicos dos vasos sanguíneos examinados em diversos órgãos vitais. Pode determinar a presença, a direção e o tipo de fluxo sanguíneo. Esta revisão de literatura compila as informações sobre os princípios físicos da ultra-sonografia Doppler. A ampliação do conhecimento desta tecnologia possibilita a melhor compreensão das aplicações e limitações deste método diagnóstico, que tem se tornado rotina na medicina veterinária de pequenos animais.(AU)
Doppler ultrasonography is a relatively new diagnostic tool in veterinary medicine that provides real time details about vascular architecture and hemodynamic aspects of examinated blood vessels in several internal organs. Doppler can identify the presence, direction and type of blood flow. This literature review provides information about the physical principles of Doppler ultrasonography. The enlargement of expertise about this technology lead to a better comprehension of its use and limitations as a diagnostic technique, which already becomes usual in veterinary medicine of small animals.(AU)
Assuntos
Ultrassonografia Doppler , UltrassonografiaResumo
Este estudo objetivou estabelecer características morfológicas e endócrinas da dinâmica luteal de fêmeas nulíparas da raça Toggenburg, e avaliar a função luteal utilizando a análise de atributos de imagens ultrassonográficas. A dinâmica luteal foi acompanhada por ultrassonografia transretal. A ecotextura luteal foi determinada em um software próprio. Cada ponto da imagem (pixel) foi quantificado dentro de uma escala de cinza (0=preto e 255=branco). Os CLs foram primeiramente detectados no dia 5,00±0,19 (D0=estro), com área média de 0,63±0,07cm2 e aumentaram progressivamente (P<0,001) até o D9, atingindo uma área máxima de 1,26±0,08cm2. A concentração plasmática de P4 aumentou progressivamente até o D9, não apresentando aumento significativo até o momento da luteólise, e 24hs depois atingiu valores inferiores a 1 ng/mL. Diferentemente, a área luteal diminuiu de forma mais lenta e gradual. Houve uma correlação significativa (P<0,05) entre a área luteal e a concentração de P4 durante o processo de luteogênese e de luteólise (r=0,63 e r=0,50, respectivamente). As alterações morfológicas, histológicas e bioquímicas observadas no CL, durante o ciclo estral, refletiram sobre a ecotextura luteal. Houve uma correlação positiva (P<0,05) entre o valor médio dos pixels e a área luteal durante a luteogênese e luteólise (r=0,34 e r=0,26, respectivamente), assim como com a P4 (r=0,24 e r=0,37, respectivamente). Estas características demonstram que a dinâmica luteal em cabras Toggenburg segue padrões semelhantes às observadas em outras raças e outras espécies e que a quantificação do valor médio dos pixels apresenta um potencial para a avaliação da função luteal na espécie caprina(AU)
The purpose of this study was to establish morphological and endocrine characteristics of luteal dymanics in Nuliparous Toggenburg goats, and evaluate luteal function by using computer-assisted ultrasonographic image analysis. Luteal dynamics was conducted by transrectal ultrasonography. Luteal echotexture was determined with the use of customized software, in which each image dot (pixel) received a numeric value ranging from 0 (black) to 255 (white). Corpora lutea were first visualized on day 5.00±0.19 with a average area of 0.63±0.07 cm2, and progressively increased in size (P<0.001) until the day 9, when reached a maximum area of 1.26±0.08 cm2. Plasma progesterone also increased until day 9 and no significant increase was observed until luteolysis - it reached values below 1 ng/mL after 24 h. Differently, the luteal area decreased in size slowly and gradually. Significant correlation (P<0.05) between progesterone levels and luteal area was observed during the processes of luteogenesis and luteolysis (r = 0.63 and r = 0.50, respectively). Morphological, edocrinological and biochemical changes noticed in CL during the estrous cycle reflected on the luteal echotexture. Positive correlation (P<0.05) was observed between the mean pixel value and the luteal tissue area during luteogenesis and luteolysis (r = 0.34 e r = 0.26, respectively), and also between mean pixel value and plasma progesterone level (r = 0.24 e r = 0.37, respectively). These characteristics showed that the luteal dynamics in Toggenbur goats present patterns similar to those noticed in other goat breeds and species and that pixel value quantification plays a potential role for the luteal function evaluation in goats(AU)
Este estudio tuvo como objetivo establecer características morfológicas y endocrinas de la dinámica luteal de hembras nulíparas de raza Toggenburg, y evaluar la función luteal utilizando el análisis de atributos de imágenes ultrasonográficas. La dinámica luteal fue acompañada por ultrasonografía transrectal. La ecotextura luteal fue determinada en un software propio. Cada punto de la imagen (pixel) fue cuantificado según una escala gris (0=negro y 255=blanco). Los CLs fueron primeramente detectados en el día 5,00±0,19 (D0=estro), con área media de 0,63±0,07cm2 y aumentaron progresivamente (P<0,001) hasta el día D9, alcanzando área máxima de 1,26±0,08cm2. La concentración plasmática de P4 se incrementó progresivamente hasta el día D9, no presentando aumento significativo hasta el momento de la luteólisis, y tras 24hs alcanzó valores inferiores a 1 ng/mL. Diferentemente, el área luteal disminuyó de forma más lenta y gradual. Hubo una correlación significativa (P<0,05) entre el área luteal y la concentración de P4 durante el proceso de "luteogênese" y de luteólisis (r=0,63 y r=0,50, respectivamente). Las alteraciones morfológicas, histológicas y bioquímicas observadas en el CL durante el ciclo estral, reflejaron sobre la ecotextura luteal. Hubo una correlación positiva (P<0,05) entre el valor medio de los pixels y el área luteal durante la "luteogênese" y luteólisis (r=0,34 e r=0,26, respectivamente), así como con la P4 (r=0,24 e r=0,37, respectivamente). Estas características demuestran que la dinámica luteal en cabras Toggenburg sigue patrones semejantes a las observadas en otras razas y otras especies, y que la cuantificación del valor medio de los pixels presenta un potencial para la evaluación de la función luteal en la especie caprina(AU)
Assuntos
Animais , Fase Luteal , Progesterona , Ciclo Estral/fisiologia , Ultrassonografia/efeitos adversos , Ultrassonografia/métodos , CabrasResumo
A ultra-sonografia Doppler é um método relativamente recente dentro da rotina veterinária que fornece informações em tempo real da arquitetura vascular e dos aspectos hemodinâmicos dos vasos sanguíneos examinados em diversos órgãos vitais. Pode determinar a presença, a direção e o tipo de fluxo sanguíneo. Esta revisão de literatura compila as informações sobre os princípios físicos da ultra-sonografia Doppler. A ampliação do conhecimento desta tecnologia possibilita a melhor compreensão das aplicações e limitações deste método diagnóstico, que tem se tornado rotina na medicina veterinária de pequenos animais.
Doppler ultrasonography is a relatively new diagnostic tool in veterinary medicine that provides real time details about vascular architecture and hemodynamic aspects of examinated blood vessels in several internal organs. Doppler can identify the presence, direction and type of blood flow. This literature review provides information about the physical principles of Doppler ultrasonography. The enlargement of expertise about this technology lead to a better comprehension of its use and limitations as a diagnostic technique, which already becomes usual in veterinary medicine of small animals.
Assuntos
Ultrassonografia , Ultrassonografia DopplerResumo
Realizaram-se exames ultra-sonográficos dúplex-Doppler abdominal em dois gatos que apresentavam sinais clínicos de encefalopatia hepática. Os principais achados ultra-sonográficos foram: identificação de um vaso anômalo tortuoso desviando o fluxo portal, velocidade de pico sistólico portal aumentada, presença de fluxo turbulento na veia cava caudal e redução do tamanho do fígado e do calibre dos vasos portais. Os achados de necropsia confirmaram os resultados dos exames ultra-sonográficos e clínicos. Pode-se concluir que o diagnóstico de shunt portossistêmico deve ser uma hipótese a ser considerada em gatos com sinais clínicos de encefalopatia hepática.(AU)
Abdominal duplex Doppler ultrasonography was used in two cats with hepatic encephalopathy clinical signs. The main ultrasonographic findings were: identification of a tortuous strange vessel shunting portal flow; elevated portal flow velocity; turbulence in the caudal vena cava, and reduced size of liver and hepatic portal branches. Necropsy findings were similar to that found at ultrasonographic and clinical exams. It is concluded that portosystemic shunt diagnosis may be a real hypothesis to be considered in cats with clinical signs of hepatic encephalopathy.(AU)
Assuntos
Animais , Hepatopatias , Ultrassonografia , Encefalopatia Hepática , Veia Porta , GatosResumo
As papilas mamárias de 23 búfalas foram avaliadas por meio de exame clínico e ultra-sonográfico. Em oito animais do mesmo grupo, as papilas mamárias foram submetidas ao exame teloscópico. Os resultados mostraram que o exame ultra-sonográfico e a teloscopia podem ser utilizados para a avaliação das papilas mamárias na espécie bubalina. As restrições ao uso desses exames, com a metodologia e os equipamentos empregados, foram: a identificação ultra-sonográfica dos ductos papilares foi precária para as papilas mais curtas, e em matrizes jovens, a resistência do ducto papilar limita o uso de telescopia axial.(AU)
All the mammart papillae from 23 water buffaloes were clinically and ultrasonographically examined, and eight animals from the same herd were submitted to theloscopic examination. The results showed that ultrasonography and theloscopy are satisfactory methods to evaluate the mammary papillae of the water buffalo. However, the ultrasonographic identification of the streak canal of the shorter papillae was poor and, it was not possible to proceed with axial theloscopy in some animals, specially the primiparous.(AU)
Assuntos
Animais , Feminino , Ultrassonografia/métodos , Ultrassonografia/veterinária , Glândulas Mamárias Animais , BúfalosResumo
A ultra-sonografia duplex Doppler é capaz de fornecer informações anatômicas e hemodinâmicas em tempo real. O conhecimento do espectro Doppler normal de cada vaso sanguíneo é importante na sua identificação, pois cada vaso possui um sinal Doppler específico. Reconhecer as alterações de morfologia do espectro somente é possível mediante o conhecimento das variações na normalidade. O objetivo deste artigo foi revisar as informações publicadas em literatura que descrevem o padrão Doppler normal dos principais vasos sanguíneos abdominais de pequenos animais.(AU)
Duplex Doppler ultrasonography is able to provide real time anatomic and hemodynamic information. The complete knowledge of the normal Doppler spectrum of each blood vessel is important to their identification, since each vessel has a specific Doppler sign. Recognizing the changes in the morphology of Doppler spectrum is only possible based on previous knowledge of its variations. This is a literature review about Doppler pattern of the major abdominal blood vessels in small animals.(AU)
Assuntos
Animais , Ultrassonografia Doppler , UltrassonografiaResumo
The aim of this study was to evaluate the effect of timing of artificial insemination on the fertility and calf sex ratio in Nelore heifers (n = 200) submitted a protocol of timed artificial insemination (TAI). The heifers, distributed into five groups (GC, GT6, GT12, GT18 and GT24), presented a mean of 2.5 years old and 342 Kg of body weight. The inseminations were performed in the moments 0 (GC), 6 (GT6), 12 (GT12), 18 (GT18) and 24 (GT24) hours after the injection of GnRH. The conception rates were 87.5% (GC), 82.5% (GT6), 77.5% (GT12), 85.0% (GT18) and 77.5% (GT24). There was no statistical difference (p>0.05) in the conception rates between the five treatments. The percentage of calved males was 38.2% (GC), 48.5% (GT6), 45.2% (GT12), 55.9% (GT18) and 58.6% (GT24). The male/female ratio was 0.62 (GC), 0.94 (GT6), 0.82 (GT12), 1.27 (GT18) and 1.42 (GT24). Statistical difference was found (p 0.05) in the male/female ratio between the five treatments. The timing of artificial insemination has influence on the sex ratio, showing an increase in the proportion of calved males when the insemination is progressively delayed. Within of the measured interval of time (0-24h after GnRH), the fertility of Nelore heifers is not influenced by the moment of the artificial insemination.KEY WORDS: Beef cattle, management, pregnancy test, ultrasound, sexing.
Objetivou-se avaliar o efeito do momento da inseminação artificial (IA) sobre a fertilidade e a proporção do sexo da cria de novilhas da raça Nelore (n = 200) submetidas a protocolo de IATF. As novilhas, distribuídas em cinco tratamentos (GC, GT6, GT12, GT18 e GT24), apresentavam idade média de 2,5 anos e peso médio de 342 kg. Realizaram-se as inseminações nos momentos 0 (GC), 6 (GT6), 12 (GT12), 18 (GT18) e 24 (GT24) horas após a aplicação do GnRH. As taxas de concepção foram de 87,5% (GC), 82,5% (GT6), 77,5% (GT12), 85,0% (GT18) e de 77,5% (GT24). Não houve diferença estatística (p>0,05) entre as taxas de concepção dos cinco tratamentos. A proporção de machos foi 38,2% (GC), 48,5% (GT6), 45,2% (GT12), 55,9% (GT18) e de 58,6% (GT24). A relação macho/fêmea foi de 0,62 (GC), 0,94 (GT6), 0,82 (GT12), 1,27 (GT18) e de 1,42 (GT24). Houve diferença significativa (p 0,05) na relação macho/fêmea entre os cinco tratamentos. O momento da inseminação artificial exerce influência sobre a relação macho/fêmea, aumentando a proporção de machos na medida em que as inseminações são realizadas mais tardiamente. Dentro do intervalo de tempo avaliado (0 a 24h após GnRH), a fertilidade das novilhas da raça Nelore não é influenciada pelo momento da inseminação artificial.PALAVRAS-CHAVES: Diagnóstico de gestação, gado de corte, manejo, ultra-sonografia, sexagem.
Resumo
A duplex ultrasound system incorporating a pulsed wave Doppler ultrasound probe with conventional B-mode real-time imaging was used to evaluate the biometric and the hemodynamic of abdominal aorta and external iliac arteries of a hundred and thirty one normal dogs. Results of biometrics of abdominal aorta, presented a mean diameter of 0.80cm in its diaphragmatic segment (AOD); 0.74cm in its segment caudal to the renal arteries (AOR) and 0.69cm in the segment cranial to its termination (AOT). The right-external-iliac artery (AIED) presented a mean diameter of 0.42cm and the left-external iliac artery (AIEE) a mean diameter of 0.39cm. The hemodynamic study of the abdominal aorta presented a medium systolic peak velocity to AOR of 104cm per sec.; to AOT of 99.61cm per sec.; to AIED of 85.47cm per sec. and to AIEE of 99.51cm per sec. Correlations of different intensities between the vascular diameters have been verified between the measured points and the corporeal biometric factors (Crown Rump-Lenght). Low correlations have been observed regarding the diameters in relation to the age.
O ultra-som bidimensional e o ultra-som Doppler foram utilizados para avaliar a biometria e a hemodinâmica da aorta abdominal e artérias ilíacas externas de 131cães clinicamente normais. Os resultados da avaliação biométrica da aorta abdominal indicaram um diâmetro médio de 0,80cm para o seu segmento diafragmático (AOD); 0,74cm para o seu segmento caudal às artérias renais (AOR) e 0,69cm para o segmento cranial à sua bifurcação (AOT). A artéria ilíaca externa direita (AIED) apresentou o diâmetro médio de 0,42cm e a artéria ilíaca externa esquerda (AIEE) o diâmetro médio de 0,39. O estudo hemodinâmico da aorta abdominal apresentou velocidade de pico sistólico médio de 104,00cm/s para AOR; 99,61cm/s para AOT; 85,47cm/s para AIED e 99,51cm/s para AIEE. Verificaram-se correlações de diferentes intensidades entre os diâmetros vasculares em diferentes pontos de tomadas e os fatores biométricos corpóreos (CRL). Correlações baixas foram observadas quando esses diâmetros foram confrontados com a idade.
Resumo
Avaliaram-se 55 cães com distúrbios neurológicos e verificou-se a ocorrência de afecções neurológicas de origem central, detectadas pela ultra-sonografia transcraniana (USTC). Vinte e nove (52,9 por cento) animais apresentaram diagnóstico compatível com hidrocefalia, e destes, 16 (55,1 por cento) eram fêmeas e 15 (51,7 por cento) tinham menos de dois anos. Quinze (27,3 por cento) cães apresentaram lesões focais, quatro (7,2 por cento), alterações difusas e quatro (7,2 por cento) apresentavam imagens sugestivas de lissencefalia; em três (5,4 por cento) não foram detectadas alterações pela USTC. A hidrocefalia foi o distúrbio neurológico de origem central mais freqüente e a USTC é uma alternativa viável para auxiliar na rotina clínica veterinária como ferramenta diagnóstica na detecção de alterações morfológicas e estruturais do cérebro no cão(AU)
In this work, 55 dogs with neurologycal disorder were examined and central neurological affections were detected by transcranial ultrasonography (TCUS). They were classifyed in hydrocephaly, lissencephaly, focal and difuse parenchimal disorders, and none changes. From the examinated dogs, 52.9 percent presented diagnosis compatible with hydrocephaly, being 55.1 percent female and 51.7 percent younger than 2 year-old. Fifteen dogs (27.3 percent) presented focal lesions, 7.2 percent diffuse lesions, 7.2 percent images that suggested lissencephaly, and in 5.4 percent no changes were detected by TCUS. It was concluded that hydrocephaly was the most frequent central neurologycal disorder and TCUS is a valuable alternative to be used in clinical routine as a tool of diagnostic to detect morphological and structural cerebral disorders in dogs(AU)
Assuntos
Animais , Cães , Ultrassonografia Doppler Transcraniana/veterinária , Hidrocefalia , Hidrocefalia/veterináriaResumo
A duplex ultrasound system incorporating a pulsed wave Doppler ultrasound probe with conventional B-mode real-time imaging was used to evaluate the biometric and the hemodynamic of abdominal aorta and external iliac arteries of a hundred and thirty one normal dogs. Results of biometrics of abdominal aorta, presented a mean diameter of 0.80cm in its diaphragmatic segment (AOD); 0.74cm in its segment caudal to the renal arteries (AOR) and 0.69cm in the segment cranial to its termination (AOT). The right-external-iliac artery (AIED) presented a mean diameter of 0.42cm and the left-external iliac artery (AIEE) a mean diameter of 0.39cm. The hemodynamic study of the abdominal aorta presented a medium systolic peak velocity to AOR of 104cm per sec.; to AOT of 99.61cm per sec.; to AIED of 85.47cm per sec. and to AIEE of 99.51cm per sec. Correlations of different intensities between the vascular diameters have been verified between the measured points and the corporeal biometric factors (Crown Rump-Lenght). Low correlations have been observed regarding the diameters in relation to the age.
O ultra-som bidimensional e o ultra-som Doppler foram utilizados para avaliar a biometria e a hemodinâmica da aorta abdominal e artérias ilíacas externas de 131cães clinicamente normais. Os resultados da avaliação biométrica da aorta abdominal indicaram um diâmetro médio de 0,80cm para o seu segmento diafragmático (AOD); 0,74cm para o seu segmento caudal às artérias renais (AOR) e 0,69cm para o segmento cranial à sua bifurcação (AOT). A artéria ilíaca externa direita (AIED) apresentou o diâmetro médio de 0,42cm e a artéria ilíaca externa esquerda (AIEE) o diâmetro médio de 0,39. O estudo hemodinâmico da aorta abdominal apresentou velocidade de pico sistólico médio de 104,00cm/s para AOR; 99,61cm/s para AOT; 85,47cm/s para AIED e 99,51cm/s para AIEE. Verificaram-se correlações de diferentes intensidades entre os diâmetros vasculares em diferentes pontos de tomadas e os fatores biométricos corpóreos (CRL). Correlações baixas foram observadas quando esses diâmetros foram confrontados com a idade.