Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Arq. bras. med. vet. zootec ; 64(4): 1065-1069, Aug. 2012. ilus, tab, graf
Artigo em Português | VETINDEX | ID: biblio-1372921

Resumo

In this study, 14 "post mortem" equine metacarpal bones were evaluated to correlate the medial III metacarpus perimeter to dorsal bone density of the same region using Computed Tomography and Quantitative Ultrasound (QUS). According to Pearson's test, there were not correlations between these variables. Considering there are few bone densitometry studies in horses and there are many variables that can interfere with bone mineralization, new studies on equine bone density applying standard variables are recommended.


Assuntos
Animais , Densidade Óssea , Diáfises/anatomia & histologia , Densitometria/veterinária , Ossos Metacarpais/ultraestrutura , Cavalos/anatomia & histologia , Tomografia/veterinária , Ultrassonografia/veterinária
2.
Artigo em Português | VETINDEX | ID: vti-447883

Resumo

In this study, 14 "post mortem" equine metacarpal bones were evaluated to correlate the medial III metacarpus perimeter to dorsal bone density of the same region using Computed Tomography and Quantitative Ultrasound (QUS). According to Pearson's test, there were not correlations between these variables. Considering there are few bone densitometry studies in horses and there are many variables that can interfere with bone mineralization, new studies on equine bone density applying standard variables are recommended.

3.
Braz. j. vet. res. anim. sci ; 48(6): 495-502, 2011.
Artigo em Português | VETINDEX | ID: vti-3589

Resumo

Objetivou-se neste estudo avaliar os efeitos da aplicação de ondas de choque extracorpóreas (ESWT) no terceiro metacarpiano de equinos hígidos através da determinação da elasticidade óssea. Foram utilizados 20 equinos Puro Sangue Inglês, machos e fêmeas, com dois anos de idade, em início de treinamento e selecionados quanto ao estado de higidez. No início do experimento (D0), todos os animais foram submetidos à avaliação da elasticidade óssea do terceiro metacarpiano. Os animais foram divididos em dois grupos (Grupo Controle - GC e Grupo Experimental - GE). A aplicação das ESWT foi realizada no membro torácico direito dos animais do GE, na região coincidente à da avaliação da elasticidade óssea. Foi utilizado aparelho para terapia de ondas extracorpóreas com densidade de fluxo de energia de 0,15mJ/mm2 e 2000 pulsos com probe E6R20, com característica do foco da onda de choque de 20 mm. A ESWT foi repetida a cada 21 dias totalizando três sessões (D0, D21 e D42). A análise da determinação da elasticidade óssea foi realizada no D0, D21, D42 e D72. A média da velocidade ultrassonográfica diferiu entre os grupos no D21, D42 e D72, sendo que os animais do GE apresentaram menor densidade mineral óssea após as aplicações das ESWT. Houve igualmente, diferença na massa óssea entre os grupos no D21 e D42, parâmetro onde os animais do GE apresentaram diminuição significativa da massa óssea. O risco de fratura apresentou-se maior nos animais do GE no D21. Concluiuse que, a ESWT é capaz de promover alteração da densidade mineral óssea.(AU)


The porpoise of this study was to evaluate the effects of extracorporeal shock waves in third metacarpus bone from healthy horses by determination of bone elasticity. It were used 20 Thoroughbred horses, male and female, with two years old, on top of training and selected as the state healthy. At the beginning of the experiment (D0), all animals were submitted for evaluation of bone elasticity held in the third metacarpus bone. The animals were divided into two groups (Control Group - CG and Experimental Group - EG). The application of extracorporeal shock wave therapy (ESWT) was performed on the right forelimb of the animals in the experimental group in the same place evaluated for bone elasticity and was used apparatus for extracorporeal therapy of waves with 0.15 mJ/mm2 energy flux density and 2000 pulses with E6R20 probe, with focus feature of the shock wave of 20 mm. The ESWT were repeated every 21 days, a total of three sessions (D0, D21 and D42). The analysis of bone elasticity determination was realized at D21, D42 and D72. The average of speed ultrasound differed between groups at D21, D42 and D72, and the animals from EG had lower bone mineral density after applications of ESWT. There was also difference in the analysis of bone mass (Z-Score) between the groups at D21 and D42, which animals from EG showed a significant decrease in bone mass. The risk of fracture was higher in animals from experimental group at D21. It was concluded that ESWT is able to promote change in bone mineral density.(AU)


Assuntos
Animais , Densidade Óssea/fisiologia , Elasticidade/fisiologia , Ossos Metacarpais/anatomia & histologia , Eletrochoque , Minerais/análise
4.
São Paulo; s.n; 06/08/2008.
Tese em Português | VETTESES | ID: vtt-6076

Resumo

A fundamentação de métodos diagnósticos precoces na ortopedia de eqüinos é de extrema importância clínica, cirúrgica e econômica. O presente estudo teve como objetivo estudar a correlação da densidade mineral óssea do terceiro metacarpiano de eqüinos, obtida pelo método de absorciometria radiográfica, com a resistência dos mesmos quando submetidos a ensaios biomecânicos de compressão e flexão. Utilizaram-se trinta pares de osso terceiro metacarpiano de eqüinos adultos, os quais foram dissecados, radiografados, analisados pelo método de absorciometria radiográfica, submetidos ao estudo tomográfico e a ensaios biomecânicos. Através dos dados obtidos não se observou correlação significativa entre os valores de densidade óptica radiográfica e as propriedades biomecânicas do osso terceiro metacarpiano. Concluiu-se que não se pode inferir que os valores de densidade óssea obtidos pela absorciometria radiográfica do osso terceiro metacarpiano de um eqüino tenha correlação com a capacidade deste osso de absorver cargas de compressão e flexão


The complete knowledge about non-invasive methods for early disgnostics in equine orthopedy is economicaly important. This experiment has studied the correlation between bone mineral density determined by radiographic absorptiometry and bone resistance of equine third metacarpal bone submitted to both compression and flexion testings. Thirty pairs of third metacarpal bone of adult horses were collected, dissected, radiographed, analysed by the radiographic absorptiometry technique, and submitted to tomographic study and biomechanical testings. The results have shown there is no significant correlation between radiographic bone density values and biomechanical properties of the third metacarpal bone. Therefore, it has been concluded bone mineral density of the third metacarpal bone determined by radiographic absorptiometry do not predict bone capacity to resist compression and flexion loads

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA