Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 335
Filtrar
1.
Arq. bras. med. vet. zootec. (Online) ; 75(4): 571-590, July-Aug. 2023. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1447355

Resumo

The present study aimed to evaluate and compare the palmar and plantar digital arteries of 10 horses and 10 mules through B-mode and spectral Doppler ultrasound. Likewise, compare the plantar arteries of the pelvic limbs with the palmar arteries of the thoracic limbs, in addition to verifying the differences of the digital arteries in the contralateral limbs (right and left) in horses and mules using B-mode and spectral Doppler ultrasonography. The evaluated parameters were the diameter and the intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI), peak of systolic velocity (pSV), final diastolic velocity (fDV) and mean velocity (MV) of the lateral and medial palmar and plantar arteries digital in healthy horses and mules. The horses presented higher diameters values, IMT, pSV, fDV and MV in comparison to the mules. The variables RI and PI also presented differences between horses and mules. Also, both species showed higher values in the variables of B-mode and Doppler ultrasonography in the thoracic limbs. Differences were also detected in the comparison between the limb sides (right and left) in the two modalities. The B-Mode and spectral Doppler ultrasound techniques are viable tools to identify differences in the palmar and plantar digital arteries in healthy horses and mules, highlight the differences between the thoracic and pelvic limbs and their respective sides (right and left) as well.


O presente estudo teve como objetivo avaliar e comparar as artérias digitais palmares e plantares de 10 equinos e 10 muares, por meio de ultrassom modo B e Doppler espectral. Da mesma forma, buscou-se comparar as artérias plantares dos membros pélvicos com as artérias palmares dos membros torácicos, além de se verificarem as diferenças das artérias digitais nos membros contralaterais (direito e esquerdo) em equinos e mulas, por meio de ultrassonografia modo B e Doppler espectral. Os parâmetros avaliados foram o diâmetro e a espessura médio-intimal (EMI), o índice de resistividade (IR), o índice de pulsatilidade (IP), o pico de velocidade sistólica (pVS), a velocidade diastólica final (VDf) e a velocidade média (VM) das artérias palmares e plantares lateral e medial digitais em equinos e muares sadios. Os equinos apresentaram maiores valores de diâmetros, EMI, pVS, VDf e VM em comparação aos muares. As variáveis IR e IP também apresentaram diferenças entre equinos e muares. Cavalos e mulas apresentaram maiores valores nas variáveis de ultrassonografia modo B e Doppler nos membros torácicos. Também foram detectadas diferenças na comparação entre os lados dos membros (direito e esquerdo) nas duas modalidades. As técnicas de ultrassom modo-B e Doppler espectral são ferramentas viáveis para identificar diferenças nas artérias digitais palmares e plantares em equinos e muares saudáveis, bem como para destacar as diferenças entre os membros torácicos e pélvicos e seus respectivos lados (direito e esquerdo).


Assuntos
Animais , Artérias , Ultrassonografia Doppler/veterinária , Cavalos , Locomoção
2.
Ciênc. Anim. (Impr.) ; 33(1): 71-78, jan.-mar. 2023. graf, ilus
Artigo em Português | VETINDEX | ID: biblio-1434509

Resumo

A hipertensão arterial sistêmica (HAS) é uma enfermidade silenciosa que pode afetar gatos e cães. Embora bastante descrita em felinos, a "Síndrome do Jaleco Branco", ou hipertensão situacional, é pouco relatada em cães. Assim, este trabalho tem como objetivo mostrar a importância do estresse na aferição da pressão arterial de cães adultos. O estudo foi realizado com 46 cães de ambos os sexos, dóceis, adultos, e aparentemente saudáveis. Após anamnese, exame físico, ambientação e manejo amigável dos animais, mensurou-se a pressão arterial sistólica (PAS) pelo método Doppler no membro torácico. Foram feitas várias aferições para obtenção de média aritmética. Animais com até 160mmHg de PAS, na primeira aferição, foram considerados normotensos (36 cães, correspondente a 78,26%). Para os que tiveram PAS maior ou igual a 160mmHg (dez cães, equivalente a 21,74%), realizou-se um segundo momento de aferição, após 15 a 30 minutos, com os animais em repouso. Assim, seis desses cães apresentaram PAS entre 154mmHg e 200mmHg, sendo, então, um considerado pré-hipertenso e cinco hipertensos, e outros quatro considerados normotensos. Para o animal com pré-hipertensão e para os hipertensos, realizaram-se exames complementares, pelos quais quatro cães foram diagnosticados com doença renal crônica e dois com dislipidemia familiar dos Schnauzers. Dessa forma, pode-se concluir que, dos 46 cães avaliados, 36 apresentaram-se normotensos (78,26%), um pré-hipertenso (2,17%), cinco hipertensos (10,87%) e quatro com hipertensão situacional (8,7%). Portanto, para cães em ambiente hospitalar, é importante realizar um manejo amigável e, quando necessário, mais de um momento de aferição de PAS para evitar diagnósticos errôneos de HAS.


Systemic arterial hypertension (SAH) is a silent disease that can affect cats and dogs. Although well described in felines, "white coat syndrome", or situational hypertension, is little reported in dogs. Thus, this paper aims to show the importance of stress in the measurement of blood pressure from adult dogs. The study was conducted with 46 dogs of both sexes, docile, adults, apparently healthy. After anamnesis, physical examination, ambiance, and friendly management of animals, systolic blood pressure (SBP) was measured by the doppler method in the thoracic limb. Several measurements were made to obtain an arithmetic average. Animals up to 160mmHg of SBP, in the first measurement, were considered normotensive (36 dogs, corresponding to 78.26%). For those with SBP higher than or equal to 160mmHg (10 dogs, equivalent to 21.74%), a second measurement was performed after 15 to 30 minutes, with the animals at rest. Therefore, six of these dogs presented SBP between 154mmHg and 200mmHg (one considered prehypertense and five hypertensives) and four normotensives. For the animal with prehypertension and the hypertensives, complementary examinations were performed, in which four dogs were diagnosed with chronic kidney disease and two with family dyslipidemia of the Schnauzers. Thus, it can be concluded that among the 46 dogs evaluated, there were 36 normotenses (78.26%), a one prehypertense (2.17%), five hypertensives (10.87%), and four with situational hypertension (8.7%). Therefore, regarding dogs in a hospital environment, it is important to perform friendly management and, when necessary, more than one moment of SBP measurement to avoid erroneous diagnoses of SAH.


Assuntos
Animais , Cães , Estresse Psicológico , Doenças do Cão , Pressão Arterial , Hipertensão/veterinária
3.
Rev. bras. zootec ; 52: e20220148, 2023. tab, graf
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1507920

Resumo

ABSTRACT The objective of this study was to evaluate the relationships between preovulatory follicle (POF) and corpus luteum (CL) diameters, and POF and CL vascular perfusion with progesterone production, ovulation, and pregnancy in Nellore cows subjected to timed artificial insemination (TAI). Nellore cows (n = 201) were subjected to ovulation synchronization and later to ultrasound evaluation of POF and CL at the time of insemination (D0) and seven days later (D7), respectively. Females were divided into three categories according to the POF diameter assessed at the time of insemination: small (SF), medium (MF), and large (LF) follicles. The LF group had a greater number and intensity of pixels in the POF ultrasound exam compared with the SF group. The CL flow intensity and progesterone concentration were also higher in the LF group. The SF group showed lower flow intensity and lower ovulation rate compared with the others. When non-pregnant females were compared to pregnant ones, no difference was observed in any of the analyzed variables. The results show for the first time in Nellore cattle the relationship between the size of ovarian structures and blood flow (quantity and intensity) as well as the ability of the CL to produce progesterone. The intensity of the POF pixels proved to be relevant, demonstrating correlations with the size and flow of the CL, which were not found when evaluating only the number of pixels, thus revealing the importance of evaluating complementary characteristics of the flow.

4.
Pesqui. vet. bras ; 43: e07212, 2023. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1507030

Resumo

Mammary neoplasia represents the most frequently diagnosed type of neoplasia in bitches. Although surgical removal is the procedure of choice for therapeutic management, chemotherapy protocols appear as important allies and adjuvants. Despite the great advances that have occurred in the field of cancer therapy, the systemic repercussions of these drugs still impose important limitations on their use. In this sense, the development of increasingly targeted therapeutic protocols and preventive monitoring of patients represent important strategies to avoid possible complications - among them, Acute Kidney Injury (AKI). Routinely, ultrasound evaluation is used to identify morphological or metastatic variations in abdominal cavity organs. Acting complementary to the B-mode evaluation, Doppler mapping proves to be efficient in recognizing alterations in vascular hemodynamics. Therefore, the objective of the present study was to evaluate the use of B-mode and Doppler ultrasound to identify renal morphological and hemodynamic alterations in bitches with mammary neoplasia submitted to adjuvant chemotherapy protocols that associate gemcitabine with carboplatin. Thirteen bitches were included, without distinction of breed and between seven and 13 years of age. The animals were evaluated ultrasonographically at two different times during three consecutive chemotherapy cycles: before (T0) and one and a half hours after each cycle (T1), for 42 days. No morphological changes were observed in B-mode throughout the chemotherapy protocol. However, the Doppler velocimetry indices demonstrated statistical differences before (T0) and after (T1) the administration of the drugs. It was concluded that Doppler ultrasound could be used as a complementary method for monitoring the renal response of patients exposed to nephrotoxic drugs and potentially causing renal injury.


As neoplasias mamárias representam o tipo de neoplasma mais frequentemente diagnosticado em fêmeas da espécie canina. Embora a remoção cirúrgica seja o procedimento de eleição para a conduta terapêutica, os protocolos quimioterápicos aparecem como importantes aliados e adjuvantes. Apesar dos grandes avanços ocorridos na área da terapia oncológica, as repercussões sistêmicas destes fármacos ainda impõem importantes limitações ao seu uso. Neste sentido, o desenvolvimento de protocolos terapêuticos cada vez mais direcionados e o monitoramento preventivo dos pacientes representam estratégias importantes para evitar possíveis complicações - dentre elas, a injúria renal aguda (IRA). Rotineiramente, a avaliação ultrassonográfica é utilizada para identificação de variações morfológicas ou metastáticas em órgãos da cavidade abdominal. Atuando de forma complementar à avaliação em modo-B, o mapeamento Doppler mostra-se eficiente no reconhecimento de alterações na hemodinâmica vascular. Portanto, o objetivo do presente estudo foi avaliar a utilização da ultrassonografia modo-B e Doppler como método para identificação de alterações morfológicas e hemodinâmicas renais em cadelas com neoplasias mamárias submetidas a protocolos quimioterápicos adjuvantes que associam a gencitabina à carboplatina. Foram incluídas 13 fêmeas caninas, sem distinção quanto a raça e com idades entre sete e 13 anos. Os animais foram avaliados ultrassonograficamente em dois momentos distintos durante três ciclos quimioterápicos consecutivos: antes (T0) e uma hora e meia após a realização de cada ciclo (T1), totalizando 42 dias. Não foram observadas alterações morfológicas em modo-B ao longo do protocolo quimioterápico. Entretanto, os índices dopplervelocimétricos demonstraram diferenças estatísticas antes (T0) e após (T1) a administração dos fármacos. Concluiu-se que a ultrassonografia Doppler pode ser utilizada como método complementar para o monitoramento da resposta renal de pacientes expostos a fármacos nefrotóxicos e potencialmente causadores de injúrias renais.


Assuntos
Animais , Feminino , Cães , Neoplasias Mamárias Animais/complicações , Quimioterapia Adjuvante/efeitos adversos , Quimioterapia Adjuvante/veterinária , Doenças do Cão , Injúria Renal Aguda/veterinária , Injúria Renal Aguda/diagnóstico por imagem , Carboplatina , Ultrassonografia Doppler/veterinária , Gencitabina
5.
Rev. bras. reprod. anim ; 46(1): 17-27, Janeiro-Março 2022. tab
Artigo em Português | VETINDEX | ID: biblio-1378025

Resumo

O objetivo desta revisão foi descrever as principais técnicas de avaliação e achados ultrassonográficos da próstata canina. A ultrassonografia é o método de escolha para avaliação da glândula prostática, sendo imprescindível como auxílio no diagnóstico na detecção de anormalidades, principalmente quando há suspeita da presença de tumores. Com inovação dos equipamentos, surgiram técnicas complementares à ultrassonografia modo Bidimensional (B), tais como Doppler, ultrassonografia contrastada e elastografia, que aumentam a acurácia diagnóstica. O Doppler fornece informações sobre arquitetura vascular e aspectos hemodinâmicos dos vasos sanguíneos. A ultrassonografia contrastada permite determinar parâmetros relacionados à perfusão sanguínea das estruturas pelos agentes de contraste (ex.: microbolhas), definindo, portanto, padrões de alta e baixa intensidade da arquitetura vascular. A elastografia proporciona a avaliação da rigidez tecidual tanto de forma qualitativa, por meio de elastogramas, quanto quantitativa, por meio das velocidades de cisalhamento. Espera-se que esta revisão possa contribuir com informações relevantes aos leitores e veterinários da área de ultrassonografia e reprodução animal.(AU)


The purpose of this review was to describe the main assessment techniques and ultrasound findings of the canine prostate. Ultrasonography is the method of choice for assessing the prostate gland, being essential as an aid in the diagnosis in the detection of abnormalities, especially when the presence of tumors is suspected. With the innovation of the equipment, complementary techniques to B-mode ultrasonography have emerged, such as Doppler, contrasted ultrasound and elastography, which increase the diagnostic accuracy. Doppler provides information on vascular architecture and hemodynamic aspects of blood vessels. Contrast ultrasonography allows to determine parameters related to the blood perfusion of structures by contrast agents (eg, microbubbles), thus defining high and low intensity patterns of vascular architecture. ARFI elastography provides assessment of tissue stiffness both qualitatively, using elastograms, and quantitative, using shear speeds. It is hoped that this review can contribute with relevant information to readers and veterinarians in the area of asound and animal reproduction.(AU)


Assuntos
Animais , Cães , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Doppler/métodos , Equipamentos para Diagnóstico/veterinária , Técnicas de Imagem por Elasticidade/métodos , Vasos Sanguíneos/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Microbolhas/veterinária , Imagem de Perfusão/veterinária , Rigidez Vascular/fisiologia
6.
Acta sci. vet. (Impr.) ; 50: Pub. 1880, 2022. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1400789

Resumo

Background: Photoplethysmography is widely used in human medicine, with few studies on its use in veterinary medicine. Its sensor detects fluctuations in blood volume at the site, providing direct readings of cardiac pulse and peripheral oxygen saturation, as well as estimating cardiac output, respiratory rate and blood pressure. This study aimed to evaluate the use of photoplethysmography and compare it to vascular Doppler ultrasound as an indirect method of measuring systolic blood pressure in bitches undergoing elective ovariohysterectomy, using the invasive assessment of systolic blood pressure as a reference. Materials, Methods and Results: After clinical and laboratory evaluation, 34 healthy bitches were selected to undergo elective ovariohysterectomy. After food and water fasting, patients received pethidine hydrochloride intramuscularly as pre-anesthetic medication, followed by anesthetic induction with fentanyl citrate and propofol intravenously. General anesthesia was maintained by inhalation with isoflurane diluted in 100% oxygen. Intraoperative analgesia consisted of continuous infusion of fentanyl citrate intravenously. The animals were randomly divided into 2 groups, the thoracic limb group (TLG) and the pelvic limb group (PLG). In each patient, non-invasive blood pressure measurement was obtained simultaneously with Doppler (DOP) and photoplethysmography (PPG). The sensors of both devices were placed on the end of the same limb. The PPG sensor was positioned in the interdigital region. In patients belonging to the TLG, the Doppler sensor was placed in the ventral region of the thoracic limb, under the ulnar artery. In PLG patients, the Doppler sensor was placed in the dorsal region of the pelvic limb, over the dorsal artery of the foot. The sphygmomanometer was positioned close to the sensors. For systolic blood pressure (SBP) measurement, the cuff was inflated until the Doppler sound signal and the plethysmographic wave were lost. The cuff was then deflated until the Doppler pulse sound resumed and the photoplethysmography showed at least 2 continuous waves on a regular basis. The corresponding pressure value observed on the manometer consisted of the SBP. The same 2 evaluators performed all SBP measurements: 1 responsible for the DOP method and the other for the PPG method; both were blind to the other's findings, thus minimizing potential bias in the results. All animals underwent cannulation of the auricular artery for invasive measurement of systolic blood pressure, using a multiparameter monitor. All blood pressure measurements were performed at 5-min intervals, as well as obtaining additional parameters (heart and respiratory rate, esophageal temperature, partial tissue oxygen saturation, carbon dioxide concentration) and electrocardiographic monitoring. All parameters were documented for further statistical analysis. A strong correlation (r² = 0.95) was obtained between the DOP and PPG methods regardless of the limb on which the sensors were placed. There was a low correlation between the invasive method of measuring systolic blood pressure and the other methods. There was better agreement between the DOP and PPG methods (r2 = -0.0061; P = 0.85) when systolic blood pressure was measured in the TLG. Discussion: In the PLG, the values obtained with the DOP and PPG methods were significantly higher than those obtained with the invasive method, while the values obtained in the TLG differed slightly. It was found that the best measurement site by non-invasive methods was the thoracic limb. It was concluded that the non-invasive methods showed a low correlation with the invasive method; however, both methods had similar characteristics and photoplethysmography can be used to replace the vascular Doppler method.


Assuntos
Animais , Feminino , Cães , Determinação da Pressão Arterial/veterinária , Ecocardiografia Doppler/métodos , Fotopletismografia/veterinária , Ovariectomia/veterinária , Histerectomia/veterinária , Anestesia Geral/veterinária
7.
Acta sci. vet. (Online) ; 50: Pub. 1849, Jan. 13, 2022. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-31327

Resumo

Background: Doppler ultrasonography enables the investigation of vascular blood flow indexes in gestational assessment,being able to detect vascular resistances that can affect fetal and maternal circulation, such as cases of placental insufficiency, associated with fetal cerebral oxygenation deficit and fetal distress. The study aims to assume hemodynamicallynormal values in the final third of gestation in bitches, of the umbilical, uteroplacental, middle cerebral and internal carotidarteries, correlating the obtained Doppler velocimetric indexes, for the assessment of the feto-placental circulation, andprediction of fetal viability indexes, fetal centralization and probable date of delivery.Materials, Methods & Results: Thirty healthy bitches were examined in the final third of gestation (40-60 days). Thesewere evaluated by Doppler ultrasonography at 2 times (T): T1: between 40-50 days; T2: between 51-60 of gestation.At each time point, the peak systolic velocities (PSV) and end-diastolic velocities (EDV) used to obtain the pulsatility(IP) and resistivity (IR) indexes of the umbilical, uteroplacental, middle cerebral and internal carotid arteries of fetuseswere evaluated. Also, the systole/diastole (S/D) ratio of these vessels was evaluated. The data obtained were subjected toanalysis of variance and Tukey test, using a P value equal to 5%. A significant difference was observed between velocitiesand Doppler velocimetric indexes between the 2 phases of the gestational final third in all studied vessels. There was anincrease in the values of PSV and EDV and a decrease in the indexes, as the probable date of delivery approached. Theanalysis of the umbilical cord IR showed an increase from P1 to P2 (P < 0.05), while the IP decreased at the same time.For all studied variables there was a statistically significant difference (P < 0.05). In the uteroplacental...(AU)


Assuntos
Animais , Feminino , Gravidez , Cães , Monitorização Hemodinâmica/métodos , Monitorização Hemodinâmica/veterinária , Circulação Placentária , Artérias Umbilicais/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Artérias Cerebrais/embriologia , Ultrassonografia Doppler/veterinária
8.
Acta sci. vet. (Impr.) ; 50: Pub.1849-2022. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1458524

Resumo

Background: Doppler ultrasonography enables the investigation of vascular blood flow indexes in gestational assessment,being able to detect vascular resistances that can affect fetal and maternal circulation, such as cases of placental insufficiency, associated with fetal cerebral oxygenation deficit and fetal distress. The study aims to assume hemodynamicallynormal values in the final third of gestation in bitches, of the umbilical, uteroplacental, middle cerebral and internal carotidarteries, correlating the obtained Doppler velocimetric indexes, for the assessment of the feto-placental circulation, andprediction of fetal viability indexes, fetal centralization and probable date of delivery.Materials, Methods & Results: Thirty healthy bitches were examined in the final third of gestation (40-60 days). Thesewere evaluated by Doppler ultrasonography at 2 times (T): T1: between 40-50 days; T2: between 51-60 of gestation.At each time point, the peak systolic velocities (PSV) and end-diastolic velocities (EDV) used to obtain the pulsatility(IP) and resistivity (IR) indexes of the umbilical, uteroplacental, middle cerebral and internal carotid arteries of fetuseswere evaluated. Also, the systole/diastole (S/D) ratio of these vessels was evaluated. The data obtained were subjected toanalysis of variance and Tukey test, using a P value equal to 5%. A significant difference was observed between velocitiesand Doppler velocimetric indexes between the 2 phases of the gestational final third in all studied vessels. There was anincrease in the values of PSV and EDV and a decrease in the indexes, as the probable date of delivery approached. Theanalysis of the umbilical cord IR showed an increase from P1 to P2 (P < 0.05), while the IP decreased at the same time.For all studied variables there was a statistically significant difference (P < 0.05). In the uteroplacental...


Assuntos
Feminino , Animais , Gravidez , Cães , Artéria Carótida Interna/diagnóstico por imagem , Artérias Cerebrais/embriologia , Artérias Umbilicais/diagnóstico por imagem , Circulação Placentária , Monitorização Hemodinâmica/métodos , Monitorização Hemodinâmica/veterinária , Ultrassonografia Doppler/veterinária
9.
Rev. bras. reprod. anim ; 45(4): 459-469, out.-dez. 2021. ilus
Artigo em Português | VETINDEX | ID: biblio-1492695

Resumo

The use of different ultrasound modalities (color, power and pulsed Doppler) in clinical research has enhanced knowledge of reproductive pathophysiology in equine, in addition to improving the clinical diagnosis of reproductive disorders in both the stallion and the mare. In the stallion, color Doppler ultrasound has improved the diagnostic potential of conventional ultrasound, improving the differential diagnosis of pathologies such as testicular torsion (decrease or absence of blood flow in the cord) and orchitis (increased blood flow in the cord). The function of the testicle is highly dependent on the blood flow it receives; therefore, any vascular alterations can affect both the quality and production of sperm. In recent years there have been a greater number of studies in which Doppler ultrasound is used as a tool in the diagnosis of testicular dysfunction and in the monitoring of medical and surgical treatments. In the mare, ultrasound technology has allowed numerous advances in basic research regarding the vascular hemodynamics of the ovary and uterus. Moreover, it has become an indispensable tool in reproductive practice. Among the clinical applications of this technique in mares are the evaluation of CL (corpus luteum) functionality, being a useful tool in the selection of recipients in embryo transfer programs or the use of power Doppler in the diagnosis of pregnancy as early as 7 days postovulation prior to flushing. Finally, the incorporation of color and pulsed Doppler ultrasound into the examination improves the diagnosis of mares with endometritis due to a pathological increase in uterine blood flow.


Assuntos
Animais , Cavalos , Fertilidade , Ultrassonografia Doppler
10.
Anim. Reprod. (Online) ; 18(2): e20210002, 2021. graf
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1285130

Resumo

Abstract The aim of this study was to evaluate the blood flow of the uterine artery, fetal aorta and umbilical artery in the physiological pregnancy of sheep by means of pulsed Doppler throughout the gestational period. Thirty Santa Inês ewes weighing between 45.4±4.3 kg and aged 2 to 5 years were selected. The evaluations were carried out weekly from the 3rd to the 21st gestational week. Peak systolic velocity (PSV), end diastolic velocity (EDV) and resistance index (RI) were obtained. Analysis of variance was performed, and the minimum significant comparison of means was obtained by the BH test with adjusted P<0.05. The results were expressed as mean ± standard error. For the fetal aorta, there was an increase in the EDV values and a decrease in the PSV and RI throughout pregnancy. For the uterine artery, PSV and EDV did not present significant variation, whereas the RI showed a reduction in the last week. Increased EDV values were found for the umbilical artery throughout pregnancy. For the PSV there was no significant difference, as the RI was reduced at the end of pregnancy. The results obtained are expected to contribute to a more complete understanding of the hemodynamic changes resulting from pregnancy.

11.
Anim. Reprod. ; 18(2): e20210002, 2021. graf
Artigo em Inglês | VETINDEX | ID: vti-31923

Resumo

The aim of this study was to evaluate the blood flow of the uterine artery, fetal aorta and umbilical artery in the physiological pregnancy of sheep by means of pulsed Doppler throughout the gestational period. Thirty Santa Inês ewes weighing between 45.4±4.3 kg and aged 2 to 5 years were selected. The evaluations were carried out weekly from the 3rd to the 21st gestational week. Peak systolic velocity (PSV), end diastolic velocity (EDV) and resistance index (RI) were obtained. Analysis of variance was performed, and the minimum significant comparison of means was obtained by the BH test with adjusted P<0.05. The results were expressed as mean ± standard error. For the fetal aorta, there was an increase in the EDV values and a decrease in the PSV and RI throughout pregnancy. For the uterine artery, PSV and EDV did not present significant variation, whereas the RI showed a reduction in the last week. Increased EDV values were found for the umbilical artery throughout pregnancy. For the PSV there was no significant difference, as the RI was reduced at the end of pregnancy. The results obtained are expected to contribute to a more complete understanding of the hemodynamic changes resulting from pregnancy.(AU)


Assuntos
Animais , Feminino , Ovinos , Artéria Uterina , Fluxo Sanguíneo Regional , Pressão Sanguínea , Prenhez
12.
Acta sci. vet. (Impr.) ; 49: Pub. 1832, 2021. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1363713

Resumo

Veterinary Ophthalmology provides complementary information for the diagnosis of ocular pathologies. Studies in wild species are essential. Among the diagnostic techniques in ophthalmology, two-dimensional ultrasonography stands out. The agouti is a rodent belonging to the Dasyproctidae family that has been widely used as an experimental model. For these animals, sight is one of the crucial senses for their survival. The aim of this study was to evaluate the effectiveness of the two-dimensional ocular ultrasound technique to obtain anatomical measurements and the external ophthalmic artery resistivity index, presumably normal in the species Dasyprocta prymnolopha. Forty eye bulbs of 20 adult rodents of the species were evaluated by ultrasonography. In these animals, B-mode echobiometry was performed using the transpalpebral approach and the hemodynamic study of the external ophthalmic artery using the color Doppler technique. All examinations were initiated by the left eye bulb and all measurements were performed by only one examiner. The collected data related to echobiometry were analyzed using Bioest 5.0 for Windows. Initially, normality was tested using the Shapiro-Wilk test for each parameter, then the paired t-test was performed, comparing right and left eyes, and a significance level of 5% (P < 0.05) was adopted. Based on the methodology used, the following values were obtained for the right and left eyeballs, respectively: anterior chamber thickness - mean of 1.28 ± 0.3 mm and 1.22 ± 0.1 mm; lens thickness - 8.27 ± 0.9 mm and 8.11 ± 0.9 mm; vitreous chamber thickness - 5.35 ± 0.48 mm and 5.30 ± 0.47 mm and axial length - 12.7 ± 0.9 mm and 13 ± 0.68 mm. The mean external ophthalmic artery resistivity values were 0.4305 ± 0.0390 and 0.4258 ± 0.0387 (right and left eye, respectively), characterizing a low resistance. There was no statistical difference between the right and left eyeballs in any of the studied parameters. The use of the convex transducer was feasible, promoting adequate contact with the ocular surface and images of satisfactory quality for obtaining measurements, similar to what was observed in studies evaluating the ocular biometry of primates and dogs. The anterior chamber thickness values in this experiment did not differ statistically between the antimers, as well as observed for dogs. The data obtained for lens thickness did not differ statistically for antimers, like those obtained for other rodent species evaluated with the same methodology. The mean values of vitreous chamber thickness were like those observed in chinchillas but correspond to about half of that obtained for capybaras. In this study, the external ophthalmic artery was characterized in all animals, but obtaining the spectral tracing was difficult due to its fine caliber. In wild animals, and especially in wild rodents, there are few data reporting the resistivity of the ophthalmic artery, and there is a lack of studies, which can be explained by the behavioral characteristics of defense and by the high susceptibility to stress in capture, since the performing the technique requires, as in other procedures, the use of chemical containment. (AU)


Assuntos
Animais , Artéria Oftálmica/anatomia & histologia , Artéria Oftálmica/diagnóstico por imagem , Dasyproctidae , Ultrassonografia/veterinária , Animais Selvagens
13.
Acta sci. vet. (Impr.) ; 49: Pub.1796-2021. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1458435

Resumo

Background: Pyometra is defined as chronic purulent inflammation of the uterus that causes changes in hematologicaland biochemical parameters. The disease is characterized with bacterial infection and pus accumulation in the uterus.Transabdominal B-mode ultrasonography provides easy and certain diagnosis of this disease. The hemodynamic changesin pyometra are evaluated by Doppler ultrasonography. The aim of the study is to determine the changes in hematologicalparameters and Doppler indices in bitches with pyometra, diestrus healthy bitches and evaluate the relationship betweenhematological parameters and hemodynamic indices within the both groups.Materials, Methods & Results: A total number of 27 bitches were enrolled in the study. The healthy diestrus bitches (groupH; n = 7) aged 6.2 ± 1.14 years, weighted 14.57 ± 3.75 kg. The bitches with pyometra (group PYO; n = 20) aged 9.1 ± 0.62years and weighted 17.65 ± 2.60 kg. Before all bitches had ovariohisterectomy, hematological analyses were performed.Transabdominal ultrasonography (USG) was performed with a 6.6 MHz convex transducer. The widest cross-sectionaluterine diameter (UD), wall thickness of uterine horns (UWT) and presence of luminal content were evaluated. Diameterof the uterine artery (DUA) was measured on a mapped color image using the USG software program. The examinationwas carried out with pulsed-wave Doppler USG to characterize the waveform of the uterine artery (UA). Anechogenic areasin uterine lumen, increase in UD and UWT were observed in group PYO. All cases in group PYO had luminal content inboth uterine horns ranging from 1.2 to 5.6 cm. The DUAs were measured in group H and in group PYO as 1.75 ± 0.03mm, 1.94 ± 0.08 mm; respectively (P < 0.05). The PI and RI values of group PYO were lower than group H (P < 0.001).Hematological analysis results showed that...


Assuntos
Feminino , Animais , Cães , Cães/microbiologia , Cães/sangue , Piometra/veterinária , Contagem de Células Sanguíneas/veterinária , Ultrassonografia Doppler de Pulso/veterinária
14.
Acta sci. vet. (Online) ; 49: Pub. 1796, Mar. 25, 2021. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-30235

Resumo

Background: Pyometra is defined as chronic purulent inflammation of the uterus that causes changes in hematologicaland biochemical parameters. The disease is characterized with bacterial infection and pus accumulation in the uterus.Transabdominal B-mode ultrasonography provides easy and certain diagnosis of this disease. The hemodynamic changesin pyometra are evaluated by Doppler ultrasonography. The aim of the study is to determine the changes in hematologicalparameters and Doppler indices in bitches with pyometra, diestrus healthy bitches and evaluate the relationship betweenhematological parameters and hemodynamic indices within the both groups.Materials, Methods & Results: A total number of 27 bitches were enrolled in the study. The healthy diestrus bitches (groupH; n = 7) aged 6.2 ± 1.14 years, weighted 14.57 ± 3.75 kg. The bitches with pyometra (group PYO; n = 20) aged 9.1 ± 0.62years and weighted 17.65 ± 2.60 kg. Before all bitches had ovariohisterectomy, hematological analyses were performed.Transabdominal ultrasonography (USG) was performed with a 6.6 MHz convex transducer. The widest cross-sectionaluterine diameter (UD), wall thickness of uterine horns (UWT) and presence of luminal content were evaluated. Diameterof the uterine artery (DUA) was measured on a mapped color image using the USG software program. The examinationwas carried out with pulsed-wave Doppler USG to characterize the waveform of the uterine artery (UA). Anechogenic areasin uterine lumen, increase in UD and UWT were observed in group PYO. All cases in group PYO had luminal content inboth uterine horns ranging from 1.2 to 5.6 cm. The DUAs were measured in group H and in group PYO as 1.75 ± 0.03mm, 1.94 ± 0.08 mm; respectively (P < 0.05). The PI and RI values of group PYO were lower than group H (P < 0.001).Hematological analysis results showed that...(AU)


Assuntos
Animais , Feminino , Cães , Piometra/veterinária , Cães/sangue , Cães/microbiologia , Ultrassonografia Doppler de Pulso/veterinária , Contagem de Células Sanguíneas/veterinária
15.
Acta sci. vet. (Impr.) ; 49: Pub.1790-2021. ilus, tab
Artigo em Português | VETINDEX | ID: biblio-1458429

Resumo

Background: Recent studies have been conducted with the aim of improving the fertility rates in the FTAI programsin beef females. The observation of the estrus expression constitutes an important indicator of fertility in zebu females.Therefore, this work has as an objective to evaluate the impact of the estrus expression on the follicular, luteal and fertilitymorphofunctional characteristics of Nelore females synchronized for FTAI.Materials, Methods & Results: Sixty five lactating female Nelore (Bos taurus indicus) were used. On a random day, denominatedday 0 (D0), the 65 Nelore females received a progesterone-releasing device associated to the application of 2.0 mg of estradiolbenzoate intramuscularly (IM). On D9, the progesterone-releasing intravaginal devices were removed and was administered500 μg of cloprostenol sodium IM; 0.6 mg of estradiol cypionate IM and 300 UI of Equine Chorionic Gonadotropin IM. At thispoint, the animals were marked with a marking stick for the determination of the estrus expression. On D11 of the synchronization protocol, the animals were characterized in two groups: without estrus expression WITHOUT ESTRUS and with estrusexpression WITH ESTRUS. The evaluation of the follicle diameter (FOLD), of the follicle wall area (FOLA), of the folliclewall vascularization (FOLV) and the percentage of vascularization in the area of the preovulatory follicle wall (%FOLV) wereconducted on D11 using B-mode ultrasonography and color Doppler and then the artificial inseminations were performed. Theevaluation of the corpus luteum diameter (CLD), the total area of the corpus luteum (CLA), of the area of vascularization of thecorpus luteum (CLV), of the percentage of vascularization of the in the area of the corpus luteum (% CLV) and the collectionof blood for the evaluation of the serum...


Assuntos
Feminino , Animais , Bovinos , Bovinos/fisiologia , Estro , Fertilidade , Inseminação Artificial/veterinária , Corpo Lúteo , Folículo Ovariano
16.
R. bras. Reprod. Anim. ; 45(1): 3-11, jan.-mar. 2021. ilus
Artigo em Inglês | VETINDEX | ID: vti-763426

Resumo

The ultrasonographic exam is of great value in animal reproduction and veterinary obstetrics, because it allows gestational diagnosis and monitoring, as well as the evaluation of the female reproductive system, providing diagnosis of the reproductive state and estrous phase of females. One of the techniques that has been employed in the field of theriogenology is the Doppler Mode, which allows qualitative and quantitative evaluation of the hemodynamics of reproductive organs. Several studies were carried out in attempt to elucidate the ultrasonographic aspect of the uterus and ovaries of bitches during the different phases of the estrous cycle in B mode and Doppler mode. The objective of the present study is to review the information present in the literature regarding the sonographic changes of the reproductive organs of bitches during the different hormonal phases.(AU)


O exame ultrassonográfico tem grande importância na reprodução animal e obstetrícia veterinária, pois permite o diagnóstico e acompanhamento gestacional, bem como a avaliação do sistema reprodutor, proporcionando o diagnóstico do status reprodutivo e fase do ciclo estral. Uma das técnicas ultrassonográficas que vêm sendo empregadas no ramo da teriogenologia é o modo Doppler, que permite avaliações qualitativas e quantitativas da hemodinâmica dos órgãos da reprodução. Diversos estudos foram realizados na tentativa de elucidar o aspecto ultrassonográfico do útero e dos ovários das cadelas durante as diferentes fases do ciclo estral ao modo-B e ao modo Doppler. O presente trabalho tem como objetivo revisar as informações presentes na literatura a respeito das mudanças ultrassonográficas dos órgãos reprodutores da cadela durante as diferentes fases hormonais.(AU)


Assuntos
Animais , Feminino , Cães , Cães/anatomia & histologia , Cães/fisiologia , Útero , Ovário , Ciclo Estral , Hemodinâmica
17.
Acta sci. vet. (Online) ; 49: Pub. 1790, 28 fev. 2021. ilus, tab
Artigo em Português | VETINDEX | ID: vti-761941

Resumo

Background: Recent studies have been conducted with the aim of improving the fertility rates in the FTAI programsin beef females. The observation of the estrus expression constitutes an important indicator of fertility in zebu females.Therefore, this work has as an objective to evaluate the impact of the estrus expression on the follicular, luteal and fertilitymorphofunctional characteristics of Nelore females synchronized for FTAI.Materials, Methods & Results: Sixty five lactating female Nelore (Bos taurus indicus) were used. On a random day, denominatedday 0 (D0), the 65 Nelore females received a progesterone-releasing device associated to the application of 2.0 mg of estradiolbenzoate intramuscularly (IM). On D9, the progesterone-releasing intravaginal devices were removed and was administered500 μg of cloprostenol sodium IM; 0.6 mg of estradiol cypionate IM and 300 UI of Equine Chorionic Gonadotropin IM. At thispoint, the animals were marked with a marking stick for the determination of the estrus expression. On D11 of the synchronization protocol, the animals were characterized in two groups: without estrus expression WITHOUT ESTRUS and with estrusexpression WITH ESTRUS. The evaluation of the follicle diameter (FOLD), of the follicle wall area (FOLA), of the folliclewall vascularization (FOLV) and the percentage of vascularization in the area of the preovulatory follicle wall (%FOLV) wereconducted on D11 using B-mode ultrasonography and color Doppler and then the artificial inseminations were performed. Theevaluation of the corpus luteum diameter (CLD), the total area of the corpus luteum (CLA), of the area of vascularization of thecorpus luteum (CLV), of the percentage of vascularization of the in the area of the corpus luteum (% CLV) and the collectionof blood for the evaluation of the serum...(AU)


Assuntos
Animais , Feminino , Bovinos , Bovinos/fisiologia , Inseminação Artificial/veterinária , Estro , Fertilidade , Folículo Ovariano , Corpo Lúteo
18.
Rev. bras. reprod. anim ; 45(1): 3-11, jan.-mar. 2021. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1492633

Resumo

The ultrasonographic exam is of great value in animal reproduction and veterinary obstetrics, because it allows gestational diagnosis and monitoring, as well as the evaluation of the female reproductive system, providing diagnosis of the reproductive state and estrous phase of females. One of the techniques that has been employed in the field of theriogenology is the Doppler Mode, which allows qualitative and quantitative evaluation of the hemodynamics of reproductive organs. Several studies were carried out in attempt to elucidate the ultrasonographic aspect of the uterus and ovaries of bitches during the different phases of the estrous cycle in B mode and Doppler mode. The objective of the present study is to review the information present in the literature regarding the sonographic changes of the reproductive organs of bitches during the different hormonal phases.


O exame ultrassonográfico tem grande importância na reprodução animal e obstetrícia veterinária, pois permite o diagnóstico e acompanhamento gestacional, bem como a avaliação do sistema reprodutor, proporcionando o diagnóstico do status reprodutivo e fase do ciclo estral. Uma das técnicas ultrassonográficas que vêm sendo empregadas no ramo da teriogenologia é o modo Doppler, que permite avaliações qualitativas e quantitativas da hemodinâmica dos órgãos da reprodução. Diversos estudos foram realizados na tentativa de elucidar o aspecto ultrassonográfico do útero e dos ovários das cadelas durante as diferentes fases do ciclo estral ao modo-B e ao modo Doppler. O presente trabalho tem como objetivo revisar as informações presentes na literatura a respeito das mudanças ultrassonográficas dos órgãos reprodutores da cadela durante as diferentes fases hormonais.


Assuntos
Feminino , Animais , Cães , Ciclo Estral , Cães/anatomia & histologia , Cães/fisiologia , Hemodinâmica , Ovário , Útero
19.
Rev. bras. reprod. anim ; 45(4): 574-582, out.-dez. 2021. ilus
Artigo em Português | VETINDEX | ID: biblio-1492711

Resumo

A ultrassonografia do sistema reprodutivo é uma importante ferramenta utilizada em associação ao exame andrológico para avaliação de machos reprodutores. Novas modalidades de análise ultrassonográfica foram descritas na última década, como a análise Doppler da artéria testicular. O objetivo deste texto é apresentar estas modalidades com o intuito de acrescentar informações importantes ao exame andrológico de cães e gatos.


The ultrasound of the reproductive system is an important tool used in association with the andrological examination to evaluate reproductive males. New modalities of ultrasound analysis have been described in the last decade, such as the Doppler analysis of the testicular artery. The objective of this text is to present these tools in order to add important information to the andrological examination of dogs and cats.


Assuntos
Animais , Gatos , Cães , Andrologia , Cães , Gatos , Ultrassonografia Doppler
20.
Arq. bras. med. vet. zootec. (Online) ; 72(4): 1137-1144, July-Aug. 2020. tab, ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-1131517

Resumo

Utilizaram-se quatro garanhões nos meses de janeiro, abril, julho e outubro de 2016, em dois protocolos, em que: GI (n=4; 5mL de solução salina, i.v.) e GII (n=4; 5000UI de hCG, i.v.) e subdividiram-se esses protocolos em ciclos (C1 e C2), seguindo o esquema crossover, sendo: CI=animais 1 (GI) e 2 (GII), avaliados nos dias D1, D3 e D5, e animais 3 (GI) e 4 (GII), em D2, D4 e D6; CII= animais 1 (GII) e 2 (GI), em D1, D3, D5, e animais 3 (GII) e 4 (GI), em D2, D4 e D6. Realizou-se o tratamento em D1 e D2 de cada ciclo e a ultrassonografia testicular no modo color Doppler e Doppler espectral, uma hora antes de cada coleta de sêmen e imediatamente após. Avaliou-se: número de reflexo de Flehmen, de montas sem ereção, início da monta, tempo de reação à ereção e total da monta e análises de qualidade seminal. Estatisticamente foram utilizados os testes de qui-quadrado e ANOVA. Não houve diferenças estatísticas (P>0,05) entre os parâmetros analisados. Concluiu-se que uma única dose de 5000UI de hCG em garanhões não causou alterações significativas nos parâmetros avaliados em diferentes estações do ano.(AU)


Four stallions were used in January, April, July and October 2016 in two protocols: GI (n=4; 5ml saline, iv) and GII (n=4; 5000 hCG, iv), and these protocols were subdivided into cycles (C1 and C2) following the cross over scheme, as follows: CI=animal 1 (GI) and 2 (GII) evaluated on days D1, D3 and D5 and animal 3 (GI) and 4 (GII) at D 2, D 4 and D 6; CII=animal 1 (GII) and 2 (GI) at D1, D3, D5 and animal 3 (GII) and 4 (GI) at D2, D4 and D6. Treatment was performed on D1 and D2 of each cycle and testicular ultrasound in color Doppler and spectral Doppler mode, one hour before each semen collection and immediately after. We evaluated: Flehmen's reflex number, mounts without erection, start of the mount, reaction time to erection and total mount and seminal quality analyzes. Statistically, the Chi-square and ANOVA tests were used. There were no statistical differences (P>0.05) between the analyzed parameters. It was concluded that a single dose of 5000IU hCG in stallions did not cause significant changes in the parameters evaluated in different seasons of the year.(AU)


Assuntos
Animais , Masculino , Testículo/diagnóstico por imagem , Gonadotropina Coriônica/administração & dosagem , Cavalos/fisiologia , Estações do Ano , Ultrassonografia Doppler em Cores/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA