Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Rev. bras. zootec ; 52: e20200241, 2023. tab
Artigo em Inglês | VETINDEX | ID: biblio-1449867

Resumo

The objective of this study was to assess the effects of two levels of soybean hulls (0 and 400.1 g/kg) and whole or ground corn in the diet of newborn crossbred dairy male calves on intake, performance, blood indicators, and feeding cost. Twenty-eight calves with an average weight of 33.0±6.2 kg and four days of age were distributed into four treatment groups in a completely randomized design (n = 7) for 56 days. Weekly samples of feed, diets, and leftovers were collected to determine dry matter and nutrient intakes. To evaluate apparent digestibility, samples were taken using titanium dioxide as a maker. Blood samples were also collected to evaluate blood indicators. The inclusion of soybean hulls resulted in greater neutral detergent fiber intake by the calves, but reduced their non-fibrous carbohydrates intake, which was also reduced by the use of whole corn in the diet. Although the total digestible nutrients content of diets decreased with the use of whole corn and inclusion of soybean hulls, its intake did not vary (0.75 kg/d), regardless of the factors analyzed. The apparent digestibilities of dry matter (0.87 kg/kg) and crude protein (0.89 kg/kg) were similar, resulting in similar performance between the animals, regardless of the factors analyzed. In the quantities evaluated, the use of soybean hulls or whole corn did not affect blood indicators and was insufficient to reduce feed costs; the cost of daily feed was $2.06, while the cost per kilogram of gain was $3.74. The inclusion of up to 400.1 g/kg of soybean hulls or the replacement of ground corn with whole corn does not affect the performance of crossbred dairy calves during the preweaning period, demonstrating that both can be used in animal feed during this phase of production.(AU)


Assuntos
Animais , Masculino , Glycine max/fisiologia , Bovinos/fisiologia , Zea mays/fisiologia , Ingestão de Alimentos/fisiologia , Grão Comestível/fisiologia
2.
Artigo em Português | VETINDEX | ID: biblio-1428473

Resumo

O jejum pré-anestésico de cães é de suma importância, pois com ele podem ser evitados problemas antes, durante e após o procedimento cirúrgico. Como o animal encontra-se em uma posição jacente, o jejum inadequado pode ocasionar refluxo, que pode levar a uma broncoaspiração e esofagite, causando complicações pós-cirúrgicas, como: apatia, pneumonia, regurgitação, êmese, disfagia e emagrecimento. Um dos carboidratos fundamentais no jejum é a glicose, que tem como função básica o fornecimento de energia. Para que o procedimento aconteça de forma equilibrada, a mensuração da concentração de glicose é indispensável, pois a identificação de um animal hiperglicêmico ou hipoglicêmico possibilita o diagnóstico precoce de inúmeras morbidades, além de atuar diretamente na terapêutica. O ideal é que o cão esteja com os níveis glicêmicos adequados (60 a 120 mg/dL), dessa forma, evita-se a ocorrência de adversidades.(AU)


Pre-anesthetic fasting of dogs is of paramount importance, because with it it is possible the avoidance of some problems before, during and after the surgery procedure. Since the animal is in a recumbent position, inadequate fasting can cause reflux, which can lead to bronchoaspiration and esophagitis, causing post-surgical complications, such as: apathy, pneumonia, regurgitation, emesis, dysphagia and slimming. One of the fundamental carbohydrates in fasting is glucose, because its basic function is to provide energy. For the procedure to happen in a balanced way, the measurement of glucose concentration is essential, since identifying a hyperglycemic or hypoglycemic animal helps the early diagnosis of numerous morbidities, in addition to acting directly in the therapy. The ideal is that the dog has adequate glycemic levels (60 to 120 mg/dL), thus avoiding possible adversities.(AU)


Assuntos
Animais , Glicemia/análise , Cães/fisiologia , Anestesia/veterinária , Jejum/fisiologia , Esofagite/diagnóstico
3.
Ciênc. rural (Online) ; 53(10): e20220415, 2023. graf
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1430200

Resumo

ABSTRACT: Using portable blood glucose meters (PBGMs) to measure blood glucose (BG) concentration is a common procedure in veterinary practice. Our objective was to evaluate the analytical and clinical accuracy of a human PBGM (Accu-Chek Performa®), (AC) and a veterinary PBGM (GlucoCalea®), (GC) in feline patients. Central venous blood samples were collected from 48 cats at a Brazilian Veterinary teaching hospital. Two devices from each model were used and compared to a reference method (RM). Analytical accuracy was assessed according to ISO 15197:2013 requirements for human PBGMs. Data were compared using Wilcoxon's nonparametric test and represented by Bland-Altman plots. Hematocrit's effect on BG measurements was evaluated by the Spearman correlation coefficient. Clinical accuracy was determined using error grid analysis (EGA). Values of BG were significantly higher in all PBGMs compared to the RM. Although ISO's analytical accuracy requirements could not be met by any of the devices, AC meters were more accurate than GC meters. All AC measurements - but not GC ones - were within zones A and B of the EGA, meeting ISO requirements for clinical accuracy. Significant hematocrit interference was observed in all devices. Therefore, AC showed greater accuracy compared to GC using feline whole blood samples.


RESUMO: O uso de glicosímetros portáteis (GPs) para aferição da glicemia é um procedimento comum na rotina clínica veterinária. O objetivo deste trabalho é avaliar a acurácia analítica e clínica de um GP humano (Accu-Chek Performa®), (AC) e um GP veterinário (GlucoCalea®), (GC) em gatos. Amostras de sangue venoso central foram coletadas de 48 gatos atendidos em um hospital veterinário-escola no Brasil. Foram utilizados dois GPs de cada modelo e comparados a um método de referência (MR). A acurácia analítica foi avaliada de acordo com os requisitos estipulados pela ISO 15197:2013 para GPs de uso humano. Os dados foram comparados pelo teste não-paramétrico de Wilcoxon e representados em gráficos de Bland-Altman. O efeito do hematócrito sobre os valores de glicemia foi avaliado pelo coeficiente de correlação de Spearman. A acurácia clínica foi avaliada pela análise da grade de erros (AGE). Em comparação com o MR, os valores de glicemia foram maiores em todos os GPs avaliados. Nenhum deles atendeu aos requisitos da ISO quanto à acurácia analítica, mas o AC mostrou-se mais acurado que o GC. Todos os valores de glicemia obtidos pelos GPs humanos - mas não pelos GPs veterinários - estiveram dentro das zonas A e B da AGE, demonstrando acurácia clínica de acordo com as exigências da ISO. A interferência do hematócrito da amostra mostrou-se significativa em todos os aparelhos testados. Portanto, o AC apresentou maior acurácia quando comparado ao GC em amostras de sangue total em felinos.

4.
Ciênc. rural (Online) ; 53(10): e20220415, 2023. graf
Artigo em Inglês | VETINDEX | ID: biblio-1434798

Resumo

Using portable blood glucose meters (PBGMs) to measure blood glucose (BG) concentration is a common procedure in veterinary practice. Our objective was to evaluate the analytical and clinical accuracy of a human PBGM (Accu-Chek Performa®), (AC) and a veterinary PBGM (GlucoCalea®), (GC) in feline patients. Central venous blood samples were collected from 48 cats at a Brazilian Veterinary teaching hospital. Two devices from each model were used and compared to a reference method (RM). Analytical accuracy was assessed according to ISO 15197:2013 requirements for human PBGMs. Data were compared using Wilcoxon's nonparametric test and represented by Bland-Altman plots. Hematocrit's effect on BG measurements was evaluated by the Spearman correlation coefficient. Clinical accuracy was determined using error grid analysis (EGA). Values of BG were significantly higher in all PBGMs compared to the RM. Although ISO's analytical accuracy requirements could not be met by any of the devices, AC meters were more accurate than GC meters. All AC measurements - but not GC ones - were within zones A and B of the EGA, meeting ISO requirements for clinical accuracy. Significant hematocrit interference was observed in all devices. Therefore, AC showed greater accuracy compared to GC using feline whole blood samples.


O uso de glicosímetros portáteis (GPs) para aferição da glicemia é um procedimento comum na rotina clínica veterinária. O objetivo deste trabalho é avaliar a acurácia analítica e clínica de um GP humano (Accu-Chek Performa®), (AC) e um GP veterinário (GlucoCalea®), (GC) em gatos. Amostras de sangue venoso central foram coletadas de 48 gatos atendidos em um hospital veterinário-escola no Brasil. Foram utilizados dois GPs de cada modelo e comparados a um método de referência (MR). A acurácia analítica foi avaliada de acordo com os requisitos estipulados pela ISO 15197:2013 para GPs de uso humano. Os dados foram comparados pelo teste não-paramétrico de Wilcoxon e representados em gráficos de Bland-Altman. O efeito do hematócrito sobre os valores de glicemia foi avaliado pelo coeficiente de correlação de Spearman. A acurácia clínica foi avaliada pela análise da grade de erros (AGE). Em comparação com o MR, os valores de glicemia foram maiores em todos os GPs avaliados. Nenhum deles atendeu aos requisitos da ISO quanto à acurácia analítica, mas o AC mostrou-se mais acurado que o GC. Todos os valores de glicemia obtidos pelos GPs humanos - mas não pelos GPs veterinários - estiveram dentro das zonas A e B da AGE, demonstrando acurácia clínica de acordo com as exigências da ISO. A interferência do hematócrito da amostra mostrou-se significativa em todos os aparelhos testados. Portanto, o AC apresentou maior acurácia quando comparado ao GC em amostras de sangue total em felinos.


Assuntos
Animais , Gatos , Glicemia , Gatos/sangue , Hemócitos
5.
Braz. j. biol ; 83: 1-6, 2023. graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1468873

Resumo

Plinia cauliflora (Mart.) Kausel, popularly known as jabuticaba, is rich in polyphenols. Phenolic compounds exhibit several biological properties, which reflect on biomarkers such as biochemical parameters. In the present study, we evaluated the plasmatic levels of glucose, total cholesterol, HDL-cholesterol, triglycerides, and uric acid of Chinese hamsters fed for 45 days with a regular diet or cholesterol-enriched diet supplemented with a liquid extract obtained from P. cauliflora fruits residues standardized in ellagic acid and total phenolic compounds. The results showed that the concentrated extract obtained from jabuticaba residues increased the glycemia of animals fed with a regular diet and reduced the plasmatic uric acid levels of animals fed with a cholesterol-enriched diet. Since hyperuricemia is considered to be a significant risk factor of metabolic disorders and the principal pathological basis of gout, the liquid extract from P. cauliflora fruits residues would be a promising candidate as a novel hypouricaemic agent for further investigation.


Plinia cauliflora (Mart.) Kausel, popularmente conhecida como jabuticaba, é rica em polifenois. Os compostos fenólicos apresentam diversas propriedades biológicas, que refletem em biomarcadores, como os parâmetros bioquímicos. No presente estudo, avaliamos os níveis plasmáticos de glicose, colesterol total, HDL-colesterol, triglicerídeos e ácido úrico em hamsters chineses alimentados por 45 dias com dieta regular ou dieta enriquecida com colesterol suplementada com extrato líquido obtido de resíduos de frutos de P. cauliflora padronizado em ácido elágico e compostos fenólicos totais. Os resultados mostraram que o extrato concentrado obtido dos resíduos de jabuticaba aumentou a glicemia dos animais alimentados com dieta regular e reduziu os níveis plasmáticos de ácido úrico dos animais alimentados com dieta rica em colesterol. Uma vez que a hiperuricemia é considerada um fator de risco significativo de distúrbios metabólicos e a principal base patológica da gota, o extrato líquido dos resíduos de frutas de P. cauliflora seria um candidato promissor como um novo agente hipouricêmico para investigação posterior.


Assuntos
Masculino , Animais , Cricetulus/sangue , Hiperuricemia/prevenção & controle , Hiperuricemia/tratamento farmacológico
6.
Braz. j. biol ; 832023.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469089

Resumo

Abstract Plinia cauliflora (Mart.) Kausel, popularly known as jabuticaba, is rich in polyphenols. Phenolic compounds exhibit several biological properties, which reflect on biomarkers such as biochemical parameters. In the present study, we evaluated the plasmatic levels of glucose, total cholesterol, HDL-cholesterol, triglycerides, and uric acid of Chinese hamsters fed for 45 days with a regular diet or cholesterol-enriched diet supplemented with a liquid extract obtained from P. cauliflora fruits residues standardized in ellagic acid and total phenolic compounds. The results showed that the concentrated extract obtained from jabuticaba residues increased the glycemia of animals fed with a regular diet and reduced the plasmatic uric acid levels of animals fed with a cholesterol-enriched diet. Since hyperuricemia is considered to be a significant risk factor of metabolic disorders and the principal pathological basis of gout, the liquid extract from P. cauliflora fruits residues would be a promising candidate as a novel hypouricaemic agent for further investigation.


Resumo Plinia cauliflora (Mart.) Kausel, popularmente conhecida como jabuticaba, é rica em polifenois. Os compostos fenólicos apresentam diversas propriedades biológicas, que refletem em biomarcadores, como os parâmetros bioquímicos. No presente estudo, avaliamos os níveis plasmáticos de glicose, colesterol total, HDL-colesterol, triglicerídeos e ácido úrico em hamsters chineses alimentados por 45 dias com dieta regular ou dieta enriquecida com colesterol suplementada com extrato líquido obtido de resíduos de frutos de P. cauliflora padronizado em ácido elágico e compostos fenólicos totais. Os resultados mostraram que o extrato concentrado obtido dos resíduos de jabuticaba aumentou a glicemia dos animais alimentados com dieta regular e reduziu os níveis plasmáticos de ácido úrico dos animais alimentados com dieta rica em colesterol. Uma vez que a hiperuricemia é considerada um fator de risco significativo de distúrbios metabólicos e a principal base patológica da gota, o extrato líquido dos resíduos de frutas de P. cauliflora seria um candidato promissor como um novo agente hipouricêmico para investigação posterior.

7.
Braz. J. Biol. ; 83: 1-6, 2023. graf
Artigo em Inglês | VETINDEX | ID: vti-765450

Resumo

Plinia cauliflora (Mart.) Kausel, popularly known as jabuticaba, is rich in polyphenols. Phenolic compounds exhibit several biological properties, which reflect on biomarkers such as biochemical parameters. In the present study, we evaluated the plasmatic levels of glucose, total cholesterol, HDL-cholesterol, triglycerides, and uric acid of Chinese hamsters fed for 45 days with a regular diet or cholesterol-enriched diet supplemented with a liquid extract obtained from P. cauliflora fruits residues standardized in ellagic acid and total phenolic compounds. The results showed that the concentrated extract obtained from jabuticaba residues increased the glycemia of animals fed with a regular diet and reduced the plasmatic uric acid levels of animals fed with a cholesterol-enriched diet. Since hyperuricemia is considered to be a significant risk factor of metabolic disorders and the principal pathological basis of gout, the liquid extract from P. cauliflora fruits residues would be a promising candidate as a novel hypouricaemic agent for further investigation.(AU)


Plinia cauliflora (Mart.) Kausel, popularmente conhecida como jabuticaba, é rica em polifenois. Os compostos fenólicos apresentam diversas propriedades biológicas, que refletem em biomarcadores, como os parâmetros bioquímicos. No presente estudo, avaliamos os níveis plasmáticos de glicose, colesterol total, HDL-colesterol, triglicerídeos e ácido úrico em hamsters chineses alimentados por 45 dias com dieta regular ou dieta enriquecida com colesterol suplementada com extrato líquido obtido de resíduos de frutos de P. cauliflora padronizado em ácido elágico e compostos fenólicos totais. Os resultados mostraram que o extrato concentrado obtido dos resíduos de jabuticaba aumentou a glicemia dos animais alimentados com dieta regular e reduziu os níveis plasmáticos de ácido úrico dos animais alimentados com dieta rica em colesterol. Uma vez que a hiperuricemia é considerada um fator de risco significativo de distúrbios metabólicos e a principal base patológica da gota, o extrato líquido dos resíduos de frutas de P. cauliflora seria um candidato promissor como um novo agente hipouricêmico para investigação posterior.(AU)


Assuntos
Animais , Masculino , Cricetulus/sangue , Hiperuricemia/tratamento farmacológico , Hiperuricemia/prevenção & controle
8.
Rev. bras. ciênc. vet ; 29(3): 125-129, jul./set. 2022. il.
Artigo em Espanhol | LILACS, VETINDEX | ID: biblio-1411217

Resumo

La medición de glucosa en caninos es un procedimiento habitual en la clínica diaria, actualmente este valor se puede obtener mediante dispositivos portátiles y pruebas laboratoriales. Se realizó esta investigación con el fin de aportar mayor conocimiento sobre la importancia de la medición de glucosa, ya que en los últimos años ha perdido valor entre las pruebas hematológicas a considerar debido a que solo se relaciona con determinadas patologías como la diabetes u otras enfermedades metabólicas. El presente trabajo tiene como objetivo comparar los valores de glucosa en caninos obtenidos mediante un glucómetro portátil de uso humano (Accu-chek® Active, Roche Diagnostic, Mannheim, Alemania); veterinario (aLcose® Vet Glu, jjPlus Corporation, New Taipei, Taiwán) y la prueba estándar de laboratorio, esto nos indicará la fiabilidad de los resultados obtenidos mediante estos métodos. Se realizó la toma de muestras de sangre de 50 caninos clínicamente sanos, de los cuales se obtuvo el resultado de glucemia mediante estos tres métodos. Los resultados de nuestra investigación evidenciaron que las tres formas de evaluación de la glucosa sanguínea en perros brindaban resultados estadísticamente diferentes (p < 0.05). Se obtuvo valores de glucosa diferentes entre los tres métodos de medición, teniendo como promedios finales 84.14 mg/dL, 101.12 mg/dL y 91.12 mg/dL correspondientes al glucómetro portátil de uso humano, veterinario y a la prueba estándar de laboratorio respectivamente. En conclusión, los glucómetros portátiles de uso humano subestiman los valores reales de glucosa, mientras que los de uso veterinario lo sobreestiman, comparados con la prueba estándar de laboratorio.


A medição de glicose nos cães é um procedimento habitual realizado no atendimento clínico. Atualmente este valor pode ser obtido por meio de dispositivos portáteis e testes laboratoriais. Esta pesquisa foi realizada com a finalidade de destacar a importância da medição de glicose, visto que nos últimos anos esta avaliação não tem sido muito valorada entre os testes hematológicos, sendo considerada relevante apenas em relação a patologias como a diabetes e outras doenças metabólicas. O presente estudo teve como objetivo comparar os valores de glicose em cães obtidos com glicômetro portátil de uso humano; veterinário e o teste padrão de laboratório. Esta comparação poderá indicar a confiabilidade dos resultados obtidos mediante os métodos avaliados. Foi realizada a amostragem do sangue de 50 caninos clinicamente sadios os quais foram submetidos a avaliação de glicose mediante os três métodos. Os resultados de nossa investigação evidenciaram que as três formas de avaliação da glicose sanguínea têm resultados estatisticamente diferentes (p < 0,05). Os valores de glicose tiveram medias finais de 84,14 mg/dL, 101,12 mg/dL e 91,12 mg/dL para o glicômetro portátil de uso humano (Accu-chek® Active, Roche Diagnostic, Mannheim, Alemanha), veterinário (aLcose® Vet Glu, jjPlus Corporation, Nova Taipei, Taiwan) e o teste padrão de laboratório, respectivamente. Ao concluir, os glicômetros portáteis de uso humano subestimam os valores reais de glicose e os de uso veterinário os superestimam quando comparados com o teste padrão de laboratório.


The measurement of glucose in canines is a common procedure in daily clinical practice. Currently this value can be obtained by use of portable devices and laboratory tests. This research was carried out in order to provide more knowledge about the importance of glucose measurement, since in recent years it has lost value among the hematological tests to be considered because it is only related to certain pathologies such as diabetes or other metabolic diseases. The present study aimed to compare the glucose values in dogs obtained with a portable glucometer for human use, veterinarian use, and the standard laboratory test. This comparison may indicate the reliability of the results obtained through the evaluated methods. A blood sampling of 50 clinically healthy canines was taken and submitted to glucose evaluation using the three methods. Our investigation showed that the three ways of assessing blood glucose have statistically different results (p < 0.05). Glucose values had final averages of 84.14 mg/dL, 101.12 mg/dL, and 91.12 mg/dL for the portable glucometer for human use (Accu-chek® Active, Roche Diagnostic, Mannheim, Germany), veterinary (aLcose® Vet Glu, jjPlus Corporation, New Taipei, Taiwan) and the standard laboratory test, respectively. In conclusion, portable glucometers for human use underestimate the glucose values, and those for veterinary use overestimate them compared to the standard laboratory test.


Assuntos
Animais , Cães , Análise Química do Sangue/veterinária , Glicemia/análise , Automonitorização da Glicemia/veterinária , Cães/sangue , Glucose/análise , Teste de Tolerância a Glucose/veterinária
9.
Rev. bras. zootec ; 50: e20200213, 2021. tab
Artigo em Inglês | VETINDEX | ID: biblio-1443547

Resumo

The objective of this work was to determine the repercussion of the metabolic changes that occur in induced subclinical pregnancy toxemia in single- or twin-bearing ewes on the duration of gestation, type and length of lambing, and placental expulsion time. Fifty-one adult Corriedale ewes with a known gestation date and fed in the wild were randomly divided at day 145 of gestation into four groups. Group A included single-bearing ewes, and C twin-bearing ewes, all of which were fed ad libitum. Group B was composed of single-bearing ewes, and D of twin-bearing ewes, all subjected to a 75% feed restriction until glycemic values were compatible with subclinical pregnancy toxemia. Metabolic parameters were determined in all ewes from day 145 of gestation to 72 h postpartum. Likewise, the duration of gestation, type of lambing (eutocic/dystocic), labor length, and placental expulsion time were recorded. Glycemia and ß-hydroxybutyrate values compatible with subclinical pregnancy toxemia were achieved after 48 h of feed restriction, being 30.67±2.37 mg/dL and 1.87±0.12 mmol/L in single-bearing ewes and 28.40±3.39 mg/dL and 2.21±0.42 mmol/L in twin-bearing ewes, respectively. It is concluded that subclinical pregnancy toxemia induced by feed restriction at the end of gestation, frequent situation that occurs in flock management, produces mild metabolic changes, which return to normal values after the delivery. These metabolic changes registered before lambing do not modify the gestation length, do not increase the percentage of dystocical deliveries, nor influence labor length or placental expulsion time.


Assuntos
Animais , Feminino , Gravidez , Pré-Eclâmpsia/veterinária , Glicemia , Ovinos , Período Periparto
10.
Ars vet ; 36(1): 47-51, 2020. tab
Artigo em Português | VETINDEX | ID: biblio-1463516

Resumo

Os glicosímetros (GT) são uma ferramenta muito utilizada no monitoramento da glicemia em cães e o hematócrito (HT) é um dos fatores que pode alterar sua acurácia, possivelmente devido a modificação da viscosidade do sangue, ao impedimento da reação com o plasma na superfície da tira, à alteração da cinética de difusão e/ou da modificação do volume plasmático, resultando em volume insuficiente de plasma para o teste dos GT. Este estudo avaliou o efeito do HT sobre o desempenho de dois GT veterinários para uso em cães em comparação a dois métodos laboratoriais de referência: glicose hexoquinase (Hx) e glicose oxidase (GOx). Ambos os GT apresentaram boa performance em amostras com HT inferior à 37%: GT1 r=0,90 com MLab Hx e r=0,94para GOx. Por sua vez, GT2 apresentou r=0,84 tanto para Hx quanto para GOx. Entretanto, apenas GT1 demonstrou desempenho adequado em amostras com HT (entre 37% e 55% (r=0,90 para Hx) e nenhum GT ofereceu atuação apropriada em amostras com HT superior à 55%. Conclui-se que o resultado apresentado por ambos GT altera de acordo com o hematócrito do animal. Deve-se considerar que pacientes com disglicemias estão frequentemente expostos às alterações clínico-patológicas, e a adoção destes GT específicos como estratégia de monitoramento pode não ser adequada, por isso a importância de outros procedimentos de medição da glicose serem empregados.


Glucometers (GT) are widely used as tools for monitoring blood glucose in dogs and hematocrit (HT) is one of the factors that can change its accuracy, possibly due to the change in blood viscosity, preventing the reaction with plasma on the surface of the strip, alteration of the diffusion kinetics and / or modification of the plasma volume, resulting in insufficient plasma volume for the GT test. This study evaluated the effect of HT on the performance of two veterinary GT for use in dogs compared to two reference laboratory methods (MLab): glucose hexokinase (Hx) and glucose oxidase (GOx). Both GT showed good performance in samples with HT below 37%: GT1 r = 0.90 with MLab Hx and r = 0.94 for GOx. In turn, GT2 presented r = 0.84 for both Hx and GOx. However, only GT1 demonstrated adequate performance in samples with HT between 37% and 55% (r = 0.90 for Hx) and no GT offered adequate performance in samples with HT greater than 55%. It can be concluded that the result presented by both GT changes according to the animal's hematocrit. It should be considered that patients with dysglycemias are frequently exposed to clinical-pathological changes, and the adoption of these specific GT as a monitoring strategy may not be adequate, so the importance of other procedures glucose measurement devices are employed.


Assuntos
Animais , Cães , Glicemia/análise , Hematócrito/veterinária , Índice Glicêmico , Teste de Tolerância a Glucose/veterinária
11.
Ars Vet. ; 36(1): 47-51, 2020. tab
Artigo em Português | VETINDEX | ID: vti-26038

Resumo

Os glicosímetros (GT) são uma ferramenta muito utilizada no monitoramento da glicemia em cães e o hematócrito (HT) é um dos fatores que pode alterar sua acurácia, possivelmente devido a modificação da viscosidade do sangue, ao impedimento da reação com o plasma na superfície da tira, à alteração da cinética de difusão e/ou da modificação do volume plasmático, resultando em volume insuficiente de plasma para o teste dos GT. Este estudo avaliou o efeito do HT sobre o desempenho de dois GT veterinários para uso em cães em comparação a dois métodos laboratoriais de referência: glicose hexoquinase (Hx) e glicose oxidase (GOx). Ambos os GT apresentaram boa performance em amostras com HT inferior à 37%: GT1 r=0,90 com MLab Hx e r=0,94para GOx. Por sua vez, GT2 apresentou r=0,84 tanto para Hx quanto para GOx. Entretanto, apenas GT1 demonstrou desempenho adequado em amostras com HT (entre 37% e 55% (r=0,90 para Hx) e nenhum GT ofereceu atuação apropriada em amostras com HT superior à 55%. Conclui-se que o resultado apresentado por ambos GT altera de acordo com o hematócrito do animal. Deve-se considerar que pacientes com disglicemias estão frequentemente expostos às alterações clínico-patológicas, e a adoção destes GT específicos como estratégia de monitoramento pode não ser adequada, por isso a importância de outros procedimentos de medição da glicose serem empregados.(AU)


Glucometers (GT) are widely used as tools for monitoring blood glucose in dogs and hematocrit (HT) is one of the factors that can change its accuracy, possibly due to the change in blood viscosity, preventing the reaction with plasma on the surface of the strip, alteration of the diffusion kinetics and / or modification of the plasma volume, resulting in insufficient plasma volume for the GT test. This study evaluated the effect of HT on the performance of two veterinary GT for use in dogs compared to two reference laboratory methods (MLab): glucose hexokinase (Hx) and glucose oxidase (GOx). Both GT showed good performance in samples with HT below 37%: GT1 r = 0.90 with MLab Hx and r = 0.94 for GOx. In turn, GT2 presented r = 0.84 for both Hx and GOx. However, only GT1 demonstrated adequate performance in samples with HT between 37% and 55% (r = 0.90 for Hx) and no GT offered adequate performance in samples with HT greater than 55%. It can be concluded that the result presented by both GT changes according to the animal's hematocrit. It should be considered that patients with dysglycemias are frequently exposed to clinical-pathological changes, and the adoption of these specific GT as a monitoring strategy may not be adequate, so the importance of other procedures glucose measurement devices are employed.(AU)


Assuntos
Animais , Cães , Glicemia/análise , Hematócrito/veterinária , Índice Glicêmico , Teste de Tolerância a Glucose/veterinária
12.
Acta sci. vet. (Impr.) ; 48: Pub.1734-Jan. 30, 2020. tab
Artigo em Português | VETINDEX | ID: biblio-1458257

Resumo

Background: Changes in glycemic levels can negatively affect the body. Several techniques for the measurement of bloodglucose have been described, but the enzymatic method is considered standard and more accurate in both humans andanimals. The College of American Pathologists recommends the use of portable glucometers (PGs), which are routinelyused in human medicine because this is an easy, relatively inexpensive method that delivers results quickly. The aim ofthis study was to compare the results of the measurement of blood glucose in cattle obtained using portable Accu-Check®glucometer with the enzymatic method (EM), which is still considered standard.Materials, Methods & Results: Thirty crossbred cattle (Bos taurus), male and female, of different ages were evaluated.Through a puncture of the jugular vein, 10 mL of blood was collected, and one drop was immediately used in an AccuChek® PG; the remaining blood was stored in tubes containing sodium fluoride and tubes containing EDTA. The sampleswere packaged and sent to the laboratory for processing. Blood glucose was measured in the sodium fluoride samples using the enzymatic-colorimetric method (EM) employing Labtest® glucose kits with automatic ELISA spectrophotometerreadings. The glycemic values obtained in this study with PG and EM ranged from 62 to 163.3 mg/dL. Mean glucoseconcentrations for the PG and EM methods were 93.53 mg/dL and 94.84 mg/dL, respectively, with no statistical difference(P > 0.05). The glycemia measurement results generated by both tests were normally distributed by the Shapiro–Wilk test(P > 0.05) and equal variances by the Levene test (P > 0.05).


Assuntos
Animais , Bovinos , Análise Química do Sangue/veterinária , Bovinos/sangue , Glicemia , Contagem de Células Sanguíneas/veterinária , Ensaio de Imunoadsorção Enzimática/veterinária
13.
Acta sci. vet. (Online) ; 48: Pub. 1734, 2 junho 2020. tab
Artigo em Português | VETINDEX | ID: vti-29431

Resumo

Background: Changes in glycemic levels can negatively affect the body. Several techniques for the measurement of bloodglucose have been described, but the enzymatic method is considered standard and more accurate in both humans andanimals. The College of American Pathologists recommends the use of portable glucometers (PGs), which are routinelyused in human medicine because this is an easy, relatively inexpensive method that delivers results quickly. The aim ofthis study was to compare the results of the measurement of blood glucose in cattle obtained using portable Accu-Check®glucometer with the enzymatic method (EM), which is still considered standard.Materials, Methods & Results: Thirty crossbred cattle (Bos taurus), male and female, of different ages were evaluated.Through a puncture of the jugular vein, 10 mL of blood was collected, and one drop was immediately used in an AccuChek® PG; the remaining blood was stored in tubes containing sodium fluoride and tubes containing EDTA. The sampleswere packaged and sent to the laboratory for processing. Blood glucose was measured in the sodium fluoride samples using the enzymatic-colorimetric method (EM) employing Labtest® glucose kits with automatic ELISA spectrophotometerreadings. The glycemic values obtained in this study with PG and EM ranged from 62 to 163.3 mg/dL. Mean glucoseconcentrations for the PG and EM methods were 93.53 mg/dL and 94.84 mg/dL, respectively, with no statistical difference(P > 0.05). The glycemia measurement results generated by both tests were normally distributed by the Shapiro–Wilk test(P > 0.05) and equal variances by the Levene test (P > 0.05). (AU)


Assuntos
Animais , Bovinos , Glicemia , Análise Química do Sangue/veterinária , Bovinos/sangue , Ensaio de Imunoadsorção Enzimática/veterinária , Contagem de Células Sanguíneas/veterinária
14.
Vet. Zoot. ; 26: 1-8, 25 nov. 2019. graf
Artigo em Português | VETINDEX | ID: vti-25140

Resumo

Os efeitos da altitude sobre parâmetros fisiológicos são amplamente estudados no homem, porém em equinos esses estudos são escassos e pouco conclusivos. O presente estudo teve como objetivo avaliar a influência da altitude nos níveis de glicose e lactato no sangue de equinos de enduro em diferentes fases de condicionamento físico. Foram utilizados 40 equinos praticantes de enduro em diferentes estágios de treinamento. Esses animais foram submetidos a testes físicos em diferentes altitudes, onde foram coletadas amostras de sangue para análise de glicose e lactato antes e após o exercício de enduro. Os animais em início de treinamento sofreram influência da alta altitude com valores maiores de lactato e glicose, enquanto que os animais melhor condicionados fisicamente sofreram pouca influência nesses dois parâmetros independente da altitude. Conclui-se que os animais com melhor condicionamento físico são pouco influenciados pelos efeitos da baixa pressão de oxigênio nos parâmetros avaliados.(AU)


The effects of altitude on physiological parameters are widely studied in humans, but in horses these studies are scarce and inconclusive. The purpose of the present study was to determine whether there is an influence of altitude in endurance horses with different fits on the glucose and lactate blood values. Forty endurance horses performed standardized exercise tests at various altitudes, and blood samples collected for analysis of glucose and lactate. The animals at the beginning of training was influenced by high altitude with increase in lactate and glucose while the best-fit animals suffered little influence in both parameters independent of altitude. Best-fit animals are little influenced by the effects of low oxygen pressure in the evaluated parameters.(AU)


Los efectos de la altitud en los parámetros fisiológicos son ampliamente estudiados en humanos, pero en los caballos estos estudios son escasos e inconclusos. El propósito del presente estudio fue determinar si existe una influencia de la altitud en caballos de resistencia con diferentes ajustes en los valores de glucosa y lactato. Cuarenta caballos de resistencia realizaron pruebas de ejercicio estandarizadas en varias altitudes y se tomaron muestras de sangre para el análisis de glucosa y lactato. Los animales al comienzo del entrenamiento fueron influenciados por la alta altitud con el aumento del lactato y la glucosa, mientras que los animales más aptos tuvieron poca influencia en ambos parámetros, independientemente de la altitud. Los animales que mejor se adaptan son poco influenciados por los efectos de la baja presión de oxígeno en los parámetros evaluados.(AU)


Assuntos
Animais , Cavalos/fisiologia , Condicionamento Físico Animal , Glicemia/análise , Ácido Láctico/sangue , Doença da Altitude/veterinária
15.
Vet. zootec ; 26: 1-8, 25 fev. 2019. graf
Artigo em Português | VETINDEX | ID: biblio-1503553

Resumo

Os efeitos da altitude sobre parâmetros fisiológicos são amplamente estudados no homem, porém em equinos esses estudos são escassos e pouco conclusivos. O presente estudo teve como objetivo avaliar a influência da altitude nos níveis de glicose e lactato no sangue de equinos de enduro em diferentes fases de condicionamento físico. Foram utilizados 40 equinos praticantes de enduro em diferentes estágios de treinamento. Esses animais foram submetidos a testes físicos em diferentes altitudes, onde foram coletadas amostras de sangue para análise de glicose e lactato antes e após o exercício de enduro. Os animais em início de treinamento sofreram influência da alta altitude com valores maiores de lactato e glicose, enquanto que os animais melhor condicionados fisicamente sofreram pouca influência nesses dois parâmetros independente da altitude. Conclui-se que os animais com melhor condicionamento físico são pouco influenciados pelos efeitos da baixa pressão de oxigênio nos parâmetros avaliados.


The effects of altitude on physiological parameters are widely studied in humans, but in horses these studies are scarce and inconclusive. The purpose of the present study was to determine whether there is an influence of altitude in endurance horses with different fits on the glucose and lactate blood values. Forty endurance horses performed standardized exercise tests at various altitudes, and blood samples collected for analysis of glucose and lactate. The animals at the beginning of training was influenced by high altitude with increase in lactate and glucose while the best-fit animals suffered little influence in both parameters independent of altitude. Best-fit animals are little influenced by the effects of low oxygen pressure in the evaluated parameters.


Los efectos de la altitud en los parámetros fisiológicos son ampliamente estudiados en humanos, pero en los caballos estos estudios son escasos e inconclusos. El propósito del presente estudio fue determinar si existe una influencia de la altitud en caballos de resistencia con diferentes ajustes en los valores de glucosa y lactato. Cuarenta caballos de resistencia realizaron pruebas de ejercicio estandarizadas en varias altitudes y se tomaron muestras de sangre para el análisis de glucosa y lactato. Los animales al comienzo del entrenamiento fueron influenciados por la alta altitud con el aumento del lactato y la glucosa, mientras que los animales más aptos tuvieron poca influencia en ambos parámetros, independientemente de la altitud. Los animales que mejor se adaptan son poco influenciados por los efectos de la baja presión de oxígeno en los parámetros evaluados.


Assuntos
Animais , Cavalos/fisiologia , Condicionamento Físico Animal , Doença da Altitude/veterinária , Glicemia/análise , Ácido Láctico/sangue
16.
Rev. Soc. Bras. Ciênc. Anim. Lab ; 5(1): 35-44, jun. 2017. tab, graf
Artigo em Português | VETINDEX | ID: biblio-1489753

Resumo

Yacon é considerado um alimento funcional, que tem entre suas propriedades capacidadehipoglicêmica. O objetivo deste estudo foi avaliar o efeito modulador do yaconno perfil glicêmico de ratos Wistar. O experimento teve duração de 60 dias com 32animais. A matriz alimentar desidratada (yacon pó / YP) foi adicionada à dieta dos gruposque receberam intervenção na dose de 7,5% de frutanos tipo inulina (FTI). As variáveisanalisadas foram: composição centesimal e conteúdo de frutanos tipo inulina, ganhode peso, peso relativo do ceco (PRC), consumo alimentar, coeficiente de eficiênciaalimentar e glicemia. Todas as análises seguiram os protocolos da AOAC. Na análiseestatística foram utilizados os seguintes testes: ANOVA ou Kruskal Wallis seguidosde testes de comparação de médias, teste t e teste t pareado. O nível de significânciaestatística foi p <0,05 para todas as análises. Este estudo foi aprovado pelo Comitê deÉtica em Uso de Animais da Universidade Federal de Alfenas, protocolo nº. 698/2015.Os resultados mostraram que no grupo controle que recebeu YP, houve uma reduçãosignificativa nos valores glicêmicos. Em todos os grupos que receberam YP houve umaumento significativo do ceco, como esperado. O desenvolvimento de diabetes nãofoi observado com o uso de estreptozotocina associado a 35% de sacarose. Portanto,a avaliação do efeito do yacon sobre a hipoglicemia foi prejudicada. Isto sugere queestudos nesta linha sejam encorajados para elucidações adicionais.


Yacon is considered a functional food, which has among its properties, and has ahypoglycemic capacity. The aim of this study was to evaluate the modulatory effectof yacon in the glycemic profile of Wistar rats. The experiment lasted 60 days with32 animals. Was used the dehydrated food matrix (yacon powder / YP) added tothe diet of the groups that received intervention in the dose of 7.5% of inulin typefructan (ITF). The analyzed variables were: centesimal composition and content ofinulin type frutans, weight gain, relative weight of cecum (RWC), food consumption,coefficient of food efficiency and glycemia. All analyzes followed the AOAC protocols.In the statistical analysis, the following tests were used: ANOVA or Kruskal Wallisfollowed by comparison tests of means, t test and paired t test. The level of statisticalsignificance was p <0.05 for all analyzes. This study was approved by the EthicsCommittee on the Use of Animals of the Federal University of Alfenas, protocol nº698/2015. The results showed that in the control group receiving YP, was a significantreduction in glycemic values. In all groups receiving YP there was a significantincrease of cecum, as expected. The development of diabetes was not observeddue to the use of streptozotocin with 35% sucrose. Therefore, the evaluation of theeffect of yacon on hypoglycaemia has been impaired. This suggests that studies inthis line are encouraged for further elucidations.


Assuntos
Animais , Ratos , Asteraceae , Dieta/veterinária , Estreptozocina/análise , Índice Glicêmico/fisiologia , Inulina/análise , Oligossacarídeos/análise
17.
R. Soc. bras. Ci. Anim. Lab. ; 5(1): 35-44, jun. 2017. tab, graf
Artigo em Português | VETINDEX | ID: vti-16761

Resumo

Yacon é considerado um alimento funcional, que tem entre suas propriedades capacidadehipoglicêmica. O objetivo deste estudo foi avaliar o efeito modulador do yaconno perfil glicêmico de ratos Wistar. O experimento teve duração de 60 dias com 32animais. A matriz alimentar desidratada (yacon pó / YP) foi adicionada à dieta dos gruposque receberam intervenção na dose de 7,5% de frutanos tipo inulina (FTI). As variáveisanalisadas foram: composição centesimal e conteúdo de frutanos tipo inulina, ganhode peso, peso relativo do ceco (PRC), consumo alimentar, coeficiente de eficiênciaalimentar e glicemia. Todas as análises seguiram os protocolos da AOAC. Na análiseestatística foram utilizados os seguintes testes: ANOVA ou Kruskal Wallis seguidosde testes de comparação de médias, teste t e teste t pareado. O nível de significânciaestatística foi p <0,05 para todas as análises. Este estudo foi aprovado pelo Comitê deÉtica em Uso de Animais da Universidade Federal de Alfenas, protocolo nº. 698/2015.Os resultados mostraram que no grupo controle que recebeu YP, houve uma reduçãosignificativa nos valores glicêmicos. Em todos os grupos que receberam YP houve umaumento significativo do ceco, como esperado. O desenvolvimento de diabetes nãofoi observado com o uso de estreptozotocina associado a 35% de sacarose. Portanto,a avaliação do efeito do yacon sobre a hipoglicemia foi prejudicada. Isto sugere queestudos nesta linha sejam encorajados para elucidações adicionais.(AU)


Yacon is considered a functional food, which has among its properties, and has ahypoglycemic capacity. The aim of this study was to evaluate the modulatory effectof yacon in the glycemic profile of Wistar rats. The experiment lasted 60 days with32 animals. Was used the dehydrated food matrix (yacon powder / YP) added tothe diet of the groups that received intervention in the dose of 7.5% of inulin typefructan (ITF). The analyzed variables were: centesimal composition and content ofinulin type frutans, weight gain, relative weight of cecum (RWC), food consumption,coefficient of food efficiency and glycemia. All analyzes followed the AOAC protocols.In the statistical analysis, the following tests were used: ANOVA or Kruskal Wallisfollowed by comparison tests of means, t test and paired t test. The level of statisticalsignificance was p <0.05 for all analyzes. This study was approved by the EthicsCommittee on the Use of Animals of the Federal University of Alfenas, protocol nº698/2015. The results showed that in the control group receiving YP, was a significantreduction in glycemic values. In all groups receiving YP there was a significantincrease of cecum, as expected. The development of diabetes was not observeddue to the use of streptozotocin with 35% sucrose. Therefore, the evaluation of theeffect of yacon on hypoglycaemia has been impaired. This suggests that studies inthis line are encouraged for further elucidations.(AU)


Assuntos
Animais , Ratos , Índice Glicêmico/fisiologia , Estreptozocina/análise , Asteraceae , Dieta/veterinária , Oligossacarídeos/análise , Inulina/análise
18.
Pesqui. vet. bras ; 37(8): 891-896, Aug. 2017. tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-895503

Resumo

Clinical evaluations of newborns, as well as defining the therapeutic decision, represent significant challenges to the veterinarian. This study aimed to evaluate neonatal vitality using the modified Apgar score and blood glucose, lactate, and cortisol concentrations in newborn equines. Twenty foals of the Paint Horse breed born by normal delivery were evaluated during the first 48 hours of life. The modified Apgar score was determined at birth and 10 minutes later, with values ranging from 0 to 10. Blood samples for the laboratory tests were collected at birth and at 4, 8, 12, 16, 20, 24, 36, and 48 hours. The mean Apgar score was significantly lower at birth than at 10 minutes (p < 0.001). Blood glucose concentrations increased significantly between birth (98.90 ± 35.97 mg/dL) and 8 hours (127.90 ± 27.15 mg/dL), stabilizing after the first 12 hours (148.95 ± 29.59 mg/dL). Serum lactate concentrations showed a significant decrease across the time points tested, with the highest value occurring at birth (5.48 ± 2.17 mmol/L) and stabilizing after 24 hours (2.76 ± 1.31 mmol/L). Cortisol concentrations significantly decreased (p < 0.01) between 4 (10.46 ± 7.46 µg/dL) and 48 hours (5.21 ± 3.35 µg/dL), with the highest value occurring 4 hours after birth. The common occurrence of laboratory abnormalities in healthy newborn foals reinforces the need to conduct regular clinical examinations and to develop laboratory reference values for different breeds and ages.(AU)


A avaliação clínica dos recém-nascidos, bem como a definição da conduta terapêutica adotada representam expressivos desafios ao Médico Veterinário. O objetivo deste estudo foi avaliar a vitalidade neonatal pelo escore de Apgar modificado, glicemia, lactatemia e cortisol em neonatos equinos. Para tal, foram utilizados 20 potros da raça Paint Horse, nascidos em eutocia, durante as primeiras 48 horas de vida. O escore de Apgar modificado foi realizado ao nascimento e 10 minutos após, atribuindo-se notas de 0 a 10. As colheitas das amostras de sangue, para a realização das análises laboratoriais, ocorreram nos momentos ao nascimento, 4, 8, 12, 20 16, 20, 24, 36 e 48 horas de vida. A média do escore de Apgar ao nascimento foi significativamente menor que aos 10 minutos (p<0,001). A glicemia aumentou significativamente entre o nascimento (98,90 ± 35,97 mg/dL) e às 8 horas (127,90 ± 23 27,15 mg/dL), com estabilização após as primeiras 12 horas (148,95 ± 29,59 mg/dL). A concentração sérica de lactato apresentou decréscimo significativo entre os momentos estudados, sendo o maior valor encontrado ao nascimento (5,48 ± 2,17 mmol/L), com estabilização a partir das 24 horas (2,76 ± 1.31 mmol/L). As concentrações de cortisol, reduziram significativamente (p<0,01), entre as 4 (10,46 ± 7,46 µg/dL) e as 48 horas (5,21 ± 3,35 µg/dL), sendo o maior valor encontrado as 4 horas após o nascimento. A ocorrência comum de anormalidades laboratoriais em potros recém-nascidos, aparentemente saudáveis, reforça a necessidade da realização de exames clínicos regulares e o desenvolvimento de valores laboratoriais de referência, em diferentes raças e idades.(AU)


Assuntos
Animais , Recém-Nascido , Hidrocortisona/sangue , Ácido Láctico/sangue , Índice Glicêmico , Cavalos/crescimento & desenvolvimento , Animais Recém-Nascidos/sangue , Índice de Apgar
19.
Pesqui. vet. bras ; 37(8): 891-896, Aug. 2017. tab
Artigo em Inglês | VETINDEX | ID: vti-23562

Resumo

Clinical evaluations of newborns, as well as defining the therapeutic decision, represent significant challenges to the veterinarian. This study aimed to evaluate neonatal vitality using the modified Apgar score and blood glucose, lactate, and cortisol concentrations in newborn equines. Twenty foals of the Paint Horse breed born by normal delivery were evaluated during the first 48 hours of life. The modified Apgar score was determined at birth and 10 minutes later, with values ranging from 0 to 10. Blood samples for the laboratory tests were collected at birth and at 4, 8, 12, 16, 20, 24, 36, and 48 hours. The mean Apgar score was significantly lower at birth than at 10 minutes (p < 0.001). Blood glucose concentrations increased significantly between birth (98.90 ± 35.97 mg/dL) and 8 hours (127.90 ± 27.15 mg/dL), stabilizing after the first 12 hours (148.95 ± 29.59 mg/dL). Serum lactate concentrations showed a significant decrease across the time points tested, with the highest value occurring at birth (5.48 ± 2.17 mmol/L) and stabilizing after 24 hours (2.76 ± 1.31 mmol/L). Cortisol concentrations significantly decreased (p < 0.01) between 4 (10.46 ± 7.46 µg/dL) and 48 hours (5.21 ± 3.35 µg/dL), with the highest value occurring 4 hours after birth. The common occurrence of laboratory abnormalities in healthy newborn foals reinforces the need to conduct regular clinical examinations and to develop laboratory reference values for different breeds and ages.(AU)


A avaliação clínica dos recém-nascidos, bem como a definição da conduta terapêutica adotada representam expressivos desafios ao Médico Veterinário. O objetivo deste estudo foi avaliar a vitalidade neonatal pelo escore de Apgar modificado, glicemia, lactatemia e cortisol em neonatos equinos. Para tal, foram utilizados 20 potros da raça Paint Horse, nascidos em eutocia, durante as primeiras 48 horas de vida. O escore de Apgar modificado foi realizado ao nascimento e 10 minutos após, atribuindo-se notas de 0 a 10. As colheitas das amostras de sangue, para a realização das análises laboratoriais, ocorreram nos momentos ao nascimento, 4, 8, 12, 20 16, 20, 24, 36 e 48 horas de vida. A média do escore de Apgar ao nascimento foi significativamente menor que aos 10 minutos (p<0,001). A glicemia aumentou significativamente entre o nascimento (98,90 ± 35,97 mg/dL) e às 8 horas (127,90 ± 23 27,15 mg/dL), com estabilização após as primeiras 12 horas (148,95 ± 29,59 mg/dL). A concentração sérica de lactato apresentou decréscimo significativo entre os momentos estudados, sendo o maior valor encontrado ao nascimento (5,48 ± 2,17 mmol/L), com estabilização a partir das 24 horas (2,76 ± 1.31 mmol/L). As concentrações de cortisol, reduziram significativamente (p<0,01), entre as 4 (10,46 ± 7,46 µg/dL) e as 48 horas (5,21 ± 3,35 µg/dL), sendo o maior valor encontrado as 4 horas após o nascimento. A ocorrência comum de anormalidades laboratoriais em potros recém-nascidos, aparentemente saudáveis, reforça a necessidade da realização de exames clínicos regulares e o desenvolvimento de valores laboratoriais de referência, em diferentes raças e idades.(AU)


Assuntos
Animais , Recém-Nascido , Hidrocortisona/sangue , Ácido Láctico/sangue , Índice Glicêmico , Cavalos/crescimento & desenvolvimento , Animais Recém-Nascidos/sangue , Índice de Apgar
20.
Pesqui. vet. bras ; 37(8)2017.
Artigo em Inglês | VETINDEX | ID: vti-743696

Resumo

ABSTRACT: Clinical evaluations of newborns, as well as defining the therapeutic decision, represent significant challenges to the veterinarian. This study aimed to evaluate neonatal vitality using the modified Apgar score and blood glucose, lactate, and cortisol concentrations in newborn equines. Twenty foals of the Paint Horse breed born by normal delivery were evaluated during the first 48 hours of life. The modified Apgar score was determined at birth and 10 minutes later, with values ranging from 0 to 10. Blood samples for the laboratory tests were collected at birth and at 4, 8, 12, 16, 20, 24, 36, and 48 hours. The mean Apgar score was significantly lower at birth than at 10 minutes (p 0.001). Blood glucose concentrations increased significantly between birth (98.90 ± 35.97 mg/dL) and 8 hours (127.90 ± 27.15 mg/dL), stabilizing after the first 12 hours (148.95 ± 29.59 mg/dL). Serum lactate concentrations showed a significant decrease across the time points tested, with the highest value occurring at birth (5.48 ± 2.17 mmol/L) and stabilizing after 24 hours (2.76 ± 1.31 mmol/L). Cortisol concentrations significantly decreased (p 0.01) between 4 (10.46 ± 7.46 g/dL) and 48 hours (5.21 ± 3.35 g/dL), with the highest value occurring 4 hours after birth. The common occurrence of laboratory abnormalities in healthy newborn foals reinforces the need to conduct regular clinical examinations and to develop laboratory reference values for different breeds and ages.


RESUMO: A avaliação clínica dos recém-nascidos, bem como a definição da conduta terapêutica adotada representam expressivos desafios ao Médico Veterinário. O objetivo deste estudo foi avaliar a vitalidade neonatal pelo escore de Apgar modificado, glicemia, lactatemia e cortisol em neonatos equinos. Para tal, foram utilizados 20 potros da raça Paint Horse, nascidos em eutocia, durante as primeiras 48 horas de vida. O escore de Apgar modificado foi realizado ao nascimento e 10 minutos após, atribuindo-se notas de 0 a 10. As colheitas das amostras de sangue, para a realização das análises laboratoriais, ocorreram nos momentos ao nascimento, 4, 8, 12, 20 16, 20, 24, 36 e 48 horas de vida. A média do escore de Apgar ao nascimento foi significativamente menor que aos 10 minutos (p 0,001). A glicemia aumentou significativamente entre o nascimento (98,90 ± 35,97 mg/dL) e às 8 horas (127,90 ± 23 27,15 mg/dL), com estabilização após as primeiras 12 horas (148,95 ± 29,59 mg/dL). A concentração sérica de lactato apresentou decréscimo significativo entre os momentos estudados, sendo o maior valor encontrado ao nascimento (5,48 ± 2,17 mmol/L), com estabilização a partir das 24 horas (2,76 ± 1.31 mmol/L). As concentrações de cortisol, reduziram significativamente (p 0,01), entre as 4 (10,46 ± 7,46 g/dL) e as 48 horas (5,21 ± 3,35 g/dL), sendo o maior valor encontrado as 4 horas após o nascimento. A ocorrência comum de anormalidades laboratoriais em potros recém-nascidos, aparentemente saudáveis, reforça a necessidade da realização de exames clínicos regulares e o desenvolvimento de valores laboratoriais de referência, em diferentes raças e idades.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA