Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ci. Rural ; 35(5)2005.
Artigo em Português | VETINDEX | ID: vti-704807

Resumo

The vegetable unit used as rice seed is a caryopsis protected by glumes, which obstruct the visualization of internal damages. X-ray radiographs in rice seeds make possible to see and identify fissures, without preparing the seeds. The objective of this work was to determine parameters that may be possible to obtain radiographs of rice seeds to evaluate fissures, after drying process. The experiment was conducted at the Laboratory of Analysis of Images of the Department of Vegetal Production, of the Superior School of Agriculture Luiz de Queiroz (ESALQ/USP), in Piracicaba-SP, Brazil. Seeds of irrigated rice of IRGA 417 and IRGA 420 cultivars were used. Seeds were submitted to different radiation intensities obtained by combinations of 11, 13, 14, 15 and 17 Kv and exposition times of 120, 180, 300, and 360 seconds. Radiographs were obtained in equipment of the FAXITRON X-Ray, with the radiographic film (KodaK, size 18x24cm), in a distance of 35 cm from the X-rays source. Films were developed in an automatic processor (Hope X-ray) and images were digitalized in scanner (Umax, PowerLook 1100), for posterior evaluation in computer. Image interpretation was not affected by cultivars, but by seed position on the film. The lateral position, with the embryo positioned to the left side make fissure visualization. Easy Low X-ray intensities produced very clear images, whith difficult identification of the fissures. The combination of 14Kv and 360s was more satisfactory, because it was possible to identify seed parts, and to show fissure without distortions. Even the best combination of calibration did not permit to clearly visualize embryo different parts.


A unidade vegetal usada como semente de arroz é uma cariópse protegida por glumelas, as quais impedem a visualização de danos internos. As radiografias de raios-X em sementes de arroz possibilitam a visualização interna e a identificação de fissuras, sem preparo prévio. O objetivo deste trabalho foi determinar parâmetros para obtenção de radiografias de raios-X em sementes de arroz, capazes de avaliar fissuras após o processo de secagem. O experimento foi conduzido no Laboratório de Análise de Imagens da Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), em Piracicaba - SP. Utilizaram-se sementes de arroz das cultivares IRGA 417 e IRGA 420, submetidas às combinações das intensidades de radiação obtidas com voltagens de 11, 13, 14, 15 e 17 kv e tempos de exposição de 120, 180, 300 e 360 segundos. As radiografias foram obtidas em aparelho de raios-X (Faxitron X-ray), com filme radiográfico Kodak (18x24cm), a uma distância de 35 cm da fonte de raios-X. Os filmes foram revelados em processadora automática (Hope X-ray) e as imagens digitalizadas em "scanner" (Umax, PowerLook, 1100), para posterior avaliação em computador. A interpretação das imagens não foi influenciada pelas cultivares, mas sim pela posição das sementes. A posição lateral, com o embrião posicionado para o lado esquerdo facilitou a visualização das fissuras. A combinação 14kv e 360s foi a mais adequada, uma vez que identificou perfeitamente as partes da semente, apresentando claramente as fissuras, sem distorções.

2.
Artigo em Português | LILACS-Express | VETINDEX | ID: biblio-1476591

Resumo

The vegetable unit used as rice seed is a caryopsis protected by glumes, which obstruct the visualization of internal damages. X-ray radiographs in rice seeds make possible to see and identify fissures, without preparing the seeds. The objective of this work was to determine parameters that may be possible to obtain radiographs of rice seeds to evaluate fissures, after drying process. The experiment was conducted at the Laboratory of Analysis of Images of the Department of Vegetal Production, of the Superior School of Agriculture Luiz de Queiroz (ESALQ/USP), in Piracicaba-SP, Brazil. Seeds of irrigated rice of IRGA 417 and IRGA 420 cultivars were used. Seeds were submitted to different radiation intensities obtained by combinations of 11, 13, 14, 15 and 17 Kv and exposition times of 120, 180, 300, and 360 seconds. Radiographs were obtained in equipment of the FAXITRON X-Ray, with the radiographic film (KodaK, size 18x24cm), in a distance of 35 cm from the X-rays source. Films were developed in an automatic processor (Hope X-ray) and images were digitalized in scanner (Umax, PowerLook 1100), for posterior evaluation in computer. Image interpretation was not affected by cultivars, but by seed position on the film. The lateral position, with the embryo positioned to the left side make fissure visualization. Easy Low X-ray intensities produced very clear images, whith difficult identification of the fissures. The combination of 14Kv and 360s was more satisfactory, because it was possible to identify seed parts, and to show fissure without distortions. Even the best combination of calibration did not permit to clearly visualize embryo different parts.


A unidade vegetal usada como semente de arroz é uma cariópse protegida por glumelas, as quais impedem a visualização de danos internos. As radiografias de raios-X em sementes de arroz possibilitam a visualização interna e a identificação de fissuras, sem preparo prévio. O objetivo deste trabalho foi determinar parâmetros para obtenção de radiografias de raios-X em sementes de arroz, capazes de avaliar fissuras após o processo de secagem. O experimento foi conduzido no Laboratório de Análise de Imagens da Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), em Piracicaba - SP. Utilizaram-se sementes de arroz das cultivares IRGA 417 e IRGA 420, submetidas às combinações das intensidades de radiação obtidas com voltagens de 11, 13, 14, 15 e 17 kv e tempos de exposição de 120, 180, 300 e 360 segundos. As radiografias foram obtidas em aparelho de raios-X (Faxitron X-ray), com filme radiográfico Kodak (18x24cm), a uma distância de 35 cm da fonte de raios-X. Os filmes foram revelados em processadora automática (Hope X-ray) e as imagens digitalizadas em "scanner" (Umax, PowerLook, 1100), para posterior avaliação em computador. A interpretação das imagens não foi influenciada pelas cultivares, mas sim pela posição das sementes. A posição lateral, com o embrião posicionado para o lado esquerdo facilitou a visualização das fissuras. A combinação 14kv e 360s foi a mais adequada, uma vez que identificou perfeitamente as partes da semente, apresentando claramente as fissuras, sem distorções.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA