Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acta cir. bras. ; 34(3): e201900304, Mar. 18, 2019. tab
Artigo em Inglês | VETINDEX | ID: vti-20869

Resumo

Purpose:To evaluate if the type of electrode (needle vs. surface) affects the electromyoneurography parameters in rats.Methods:Twenty male rats were anesthetized, then compound muscle action potential were recorded using a Neuropack S1 MEB- 9400©. All animals were submitted to two electroneuromyography analysis: first with surface electrode and then by needle electrode. We evaluated the latency, amplitude, duration and area of the negative peak of the gastrocnemius and cranial tibial muscles.Results:There were no significant differences between the groups in the mean of duration, latency, amplitude or area of the negative peak in gastrocnemius and cranial tibial muscles.Conclusion:The type of electrode does not affect the electroneuromyography parameters.(AU)


Assuntos
Animais , Ratos , Eletrodos/veterinária , Monitorização Neurofisiológica/veterinária , Músculo Esquelético , Exame Neurológico/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA