Resumo
Most genetic diseases affect purebred animals and are inherited as recessive genes. Cranioschisis refers to dysraphism, which occurs in the midline of the skull due to failure to close the cranial symphysis, which can lead to herniation of the meninges filled with cerebrospinal fluid (meningocele), where there is usually a projection of the meningeal tissue. Diagnosis is performed based on clinical examination, characteristic anatomopathological data, and complementary imaging tests. The surgical approach for correction of cranioschisis is the only described as a therapeutic solution and is indicated in cases in which the cranial synthesis defect does not allow for brain protrusion and there is only the occurrence of meningocele, in addition to the absence of severe signs of neurological alteration. This paper reports a case of the use of polymethylmethacrylate (PMMA) plaque to treat cranioschisis associated with meningocele in a Girolando heifer. The surgical opening of the frontonasal sacculation allowed draining a total liquid content of 488 mL, inspection, and suture of the envelope membrane. APMMA plaque, molded to the bone surface and anchored in the adjacent soft tissue, was used to cover the evidenced frontonasal bone opening. Despite the unfavorable prognosis of the disease, the cranioplasty surgery for the treatment of cranioschisis associated with meningocele using PMMA plaque obtained satisfactory results relative to the quality and maintenance of this animal's life, evaluated at 19 months postoperatively.(AU)
A maioria das doenças genéticas acometem animais de raça pura e herdados como genes recessivos.Acraniosquise refere-se à disrafia, que acontece na linha média do crânio pelo não fechamento da sínfise craniana, podendo levar a herniação das meninges repletas de líquido cefalorraquidiano (meningocele), onde geralmente existe projeção do tecido meningeal. O diagnóstico é realizado a partir do exame clínico, dados anatomopatológicos característicos e através da realização de exames complementares de imagem. Como solução terapêutica, a abordagem cirúrgica para correção das craniosquises é a única descrita, e é indicada em casos em que o defeito de síntese craniana não permita a protrusão encefálica e exista a ocorrência apenas da meningocele, além da inexistência de sinais graves de alteração neurológica. O artigo relata um caso de uso de placa de polimetilmetacrilato (PMMA) no tratamento de craniosquise associada à meningocele em uma bezerra Girolando. Instituiu-se a abertura cirúrgica da saculação fronto-nasal, permitindo a drenagem de conteúdo líquido total de 488 mL, inspeção e rafia de membrana envoltória. Para recobrimento da abertura óssea fronto-nasal evidenciada, utilizou-se uma placa de polimetilmetacrilato (PMMA), moldada à superfície óssea e ancorada em tecido mole adjacente. Concluiu-se que, apesar do prognóstico desfavorável da enfermidade, a cirurgia de cranioplastia para tratamento de craniosquise associada à meningocele, com a utilização de placa de PMMA, neste caso, obteve resultados satisfatórios em relação a qualidade e manutenção da vida deste animal, avaliando-se em 19 meses pós-operatório.(AU)
Assuntos
Animais , Feminino , Bovinos , Disrafismo Espinal/tratamento farmacológico , Polimetil Metacrilato/uso terapêutico , Meningocele/tratamento farmacológico , Doenças Genéticas Inatas/veterináriaResumo
Polymethylmethacrylate bone cement is a standard material used as antibiotic carrier in the orthopedic surgery. The ultrasonic energy method is capable of triggering biological effects based on both thermal and non-thermal mechanisms. The aim of the current study is to analyze methylene blue dispersion in polymethylmethacrylate beads, in association with the acoustic field generated by non-thermal ultrasound. Forty-nine specimens were used, and each specimen comprised one polymethylmethacrylate bead (0.6-mm diameter) doped with methylene blue and deposited in gelatin sample. Forty test specimens were divided into four groups comprising 10 samples, each, based on different ultrasound intensities (Group 1: 1.0 W/cm2; Group 2: 1.5 W/cm2) and polymethylmethacrylate bead depths (A - 2 cm; B - 3 cm) in gelatin sample. The control group comprised other nine specimens and statistically differed from the other groups. All groups irradiated with ultrasound have shown statistically significant differences in methylene blue dispersion, except for Groups 2A and 2B. Methylene blue dispersion in gelatin among groups was 1A> 1B; 2A> 1A; 2B> 1A; 2A> 1B; and 2B> 1B. Low-intensity ultrasound enabled the highest methylene blue dispersion when polymethylmethacrylate bead was positioned superficial; bead depth associated with high-intensity ultrasound did not influence methylene blue dispersion.
O cimento ósseo de polimetilmetacrilato é considerado um material padrão como carreador de antibiótico em cirurgias ortopédicas. A energia ultrassônica é um método capaz de gerar efeitos biológicos por mecanismos térmicos e não térmicos. Este estudo teve como objetivo analisar a dispersão de azul de metileno em pérolas de polimetilmetacrilato combinada com a exposição em campo acústico gerado por ultrassom não térmico. Foram utilizados 49 corpos-de-prova, cada um composto por uma pérola de polimetilmetacrilato (0,6 mm de diâmetro) dopada com azul de metileno e depositada em amostra de gelatina. Quarenta espécimes foram divididos em quatro grupos de 10 amostras com base nas intensidades de ultrassom (Grupo 1: 1,0 W/cm2; Grupo 2: 1,5 W/cm2) e profundidade (A - 2 cm; B - 3 cm) dos grânulos de polimetilmetacrilato na amostra de gelatina. Os outros nove espécimes constituíram o grupo controle. O grupo controle diferiu estatisticamente dos outros grupos. Todos os grupos irradiados com ultrassom apresentaram diferenças significativas, exceto os Grupos 2A e 2B. A dispersão de azul de metileno na gelatina entre os grupos foi: 1A> 1B; 2A> 1A; 2B> 1A; 2A> 1B; 2B> 1B. Ultrassom de baixa intensidade permitiu maior dispersão de azul de metileno com polimetilmetacrilato posicionado mais superficialmente, e não ocorreu influência da profundidade da pérola com ultrassom de alta intensidade.
Assuntos
Consolidação da Fratura , Polimetil Metacrilato , Procedimentos Ortopédicos , Azul de Metileno , Fonoforese , AntibacterianosResumo
ABSTRACT Purpose To analyze and compare the reactions at the interface between the composite, composed of fragmented heterologous mineralized bone matrix (MOMHF) and polymethylmethacrylate (PMMA), and the rabbit's tibias, through macroscopic evaluation and scanning electron microscopy (SEM) in different periods. Methods In this study, 12 New Zealand adult rabbits were used (E1: n = 3, E2: n = 3, E3: n = 3 and E4: n = 3). They had the right tibial defects filled with composite and were evaluated immediately after surgery and at 30, 60, 90, and 120 days. Results The composites were incorporated and integrated into the recipient beds in 100% of the cases, defined by the MOMHF osseointegration and the PMMA fibrointegration, with no sign of infection, migration, or rejection. Conclusions The behavior of the composites in the recipient beds demonstrates that these biomaterials have the potential to be used in bone defect repairs, offering, thus, better quality of life to the orthopedic patient.
Assuntos
Matriz Óssea , Polimetil Metacrilato , Qualidade de Vida , Coelhos , Tíbia/cirurgia , Materiais Biocompatíveis , OsseointegraçãoResumo
O cimento ósseo de polimetilmetacrilato é considerado um material padrão como carreador de antibiótico em cirurgias ortopédicas. A energia ultrassônica é um método capaz de gerar efeitos biológicos por mecanismos térmicos e não térmicos. Este estudo teve como objetivo analisar a dispersão de azul de metileno em pérolas de polimetilmetacrilato combinada com a exposição em campo acústico gerado por ultrassom não térmico. Foram utilizados 49 corpos-de-prova, cada um composto por uma pérola de polimetilmetacrilato (0,6 mm de diâmetro) dopada com azul de metileno e depositada em amostra de gelatina. Quarenta espécimes foram divididos em quatro grupos de 10 amostras com base nas intensidades de ultrassom (Grupo 1: 1,0 W/cm2; Grupo 2: 1,5 W/cm2) e profundidade (A - 2 cm; B - 3 cm) dos grânulos de polimetilmetacrilato na amostra de gelatina. Os outros nove espécimes constituíram o grupo controle. O grupo controle diferiu estatisticamente dos outros grupos. Todos os grupos irradiados com ultrassom apresentaram diferenças significativas, exceto os Grupos 2A e 2B. A dispersão de azul de metileno na gelatina entre os grupos foi: 1A> 1B; 2A> 1A; 2B> 1A; 2A> 1B; 2B> 1B. Ultrassom de baixa intensidade permitiu maior dispersão de azul de metileno com polimetilmetacrilato posicionado mais superficialmente, e não ocorreu influência da profundidade da pérola com ultrassom de alta intensidade.
Polymethylmethacrylate bone cement is a standard material used as antibiotic carrier in the orthopedic surgery. The ultrasonic energy method is capable of triggering biological effects based on both thermal and non-thermal mechanisms. The aim of the current study is to analyze methylene blue dispersion in polymethylmethacrylate beads, in association with the acoustic field generated by non-thermal ultrasound. Forty-nine specimens were used, and each specimen comprised one polymethylmethacrylate bead (0.6-mm diameter) doped with methylene blue and deposited in gelatin sample. Forty test specimens were divided into four groups comprising 10 samples, each, based on different ultrasound intensities (Group 1: 1.0 W/cm2; Group 2: 1.5 W/cm2) and polymethylmethacrylate bead depths (A - 2 cm; B - 3 cm) in gelatin sample. The control group comprised other nine specimens and statistically differed from the other groups. All groups irradiated with ultrasound have shown statistically significant differences in methylene blue dispersion, except for Groups 2A and 2B. Methylene blue dispersion in gelatin among groups was 1A> 1B; 2A> 1A; 2B> 1A; 2A> 1B; and 2B> 1B. Low-intensity ultrasound enabled the highest methylene blue dispersion when polymethylmethacrylate bead was positioned superficial; bead depth associated with high-intensity ultrasound did not influence methylene blue dispersion.
Assuntos
Azul de Metileno , Cimentos Ósseos , Fonoforese , Polimetil Metacrilato/efeitos da radiaçãoResumo
Background: Acute spinal traumas can lead to irreversible damage associated with vascular and inflammatory changes in neural tissue. Since spine and spinal cord traumas have an unfavorable prognosis in small animals, and reports of the use of Steinmann pins and polymethylmethacrylate repair of lumbar vertebra fracture-luxation in puppies are rare in the literature, the present paper aimed to report the surgical treatment of transversal fracture through the body of the fourth lumbar vertebra, with dorsocranial displacement of the caudal fragment by using Steinmann pins and polymethylmethacrylate in a 7-month-old Labrador Retriever male dog. Case: A 7-month-old intact male Labrador Retriever dog, weighing 24.0 kg was attended at School Veterinary Hospital with a history of hit by car and paraplegia of the hind limbs. On neurological examination was observed no proprioception and no deep pain sensitivity on the both pelvic limbs. The lumbar spinal palpation showed intense pain, and the motor function and patellar reflexes were reduced. The values of haematological and biochemical analysis remained within the reference values for the species. Radiographs revealed a transversal fracture through the body of the fourth lumbar vertebra, with dorsocranial displacement of the caudal fragment, and was decided to perform a surgical treatment by open reduction and internal fixation of the fracture. The dog was positioned in ventral recumbency for surgery, and a dorsal midline incision was made from the second lumbar vertebra to the sixth lumbar vertebra. Two crossed 1.5 mm Kirschner wires were placed through the caudal articular facets of the fourth lumbar vertebra to provide initial stability...
Assuntos
Masculino , Animais , Cães , Luxações Articulares/veterinária , Pinos Ortopédicos/veterinária , Polimetil Metacrilato , Vértebras Lombares/cirurgia , Vértebras Lombares/lesões , Traumatismos da Medula Espinal/cirurgia , Traumatismos da Medula Espinal/veterináriaResumo
Background: Acute spinal traumas can lead to irreversible damage associated with vascular and inflammatory changes in neural tissue. Since spine and spinal cord traumas have an unfavorable prognosis in small animals, and reports of the use of Steinmann pins and polymethylmethacrylate repair of lumbar vertebra fracture-luxation in puppies are rare in the literature, the present paper aimed to report the surgical treatment of transversal fracture through the body of the fourth lumbar vertebra, with dorsocranial displacement of the caudal fragment by using Steinmann pins and polymethylmethacrylate in a 7-month-old Labrador Retriever male dog. Case: A 7-month-old intact male Labrador Retriever dog, weighing 24.0 kg was attended at School Veterinary Hospital with a history of hit by car and paraplegia of the hind limbs. On neurological examination was observed no proprioception and no deep pain sensitivity on the both pelvic limbs. The lumbar spinal palpation showed intense pain, and the motor function and patellar reflexes were reduced. The values of haematological and biochemical analysis remained within the reference values for the species. Radiographs revealed a transversal fracture through the body of the fourth lumbar vertebra, with dorsocranial displacement of the caudal fragment, and was decided to perform a surgical treatment by open reduction and internal fixation of the fracture. The dog was positioned in ventral recumbency for surgery, and a dorsal midline incision was made from the second lumbar vertebra to the sixth lumbar vertebra. Two crossed 1.5 mm Kirschner wires were placed through the caudal articular facets of the fourth lumbar vertebra to provide initial stability...(AU)
Assuntos
Animais , Masculino , Cães , Polimetil Metacrilato , Vértebras Lombares/lesões , Vértebras Lombares/cirurgia , Luxações Articulares/veterinária , Pinos Ortopédicos/veterinária , Traumatismos da Medula Espinal/cirurgia , Traumatismos da Medula Espinal/veterináriaResumo
Background: The hemangiossarcoma (HSA) is a malignant tumor originated from the alterations of vascular endothelialcells. As it has an aggressive behavior, it is indicated, as initial treatment, wide surgical excision, such as the exenteration, which results in the surgical removal of the ocular bulb and adjacent tissues. The referred technique has as a resulta concave orbit and aesthetically unacceptable. Therefore, various materials, used as orbital implants, have been studiedand used in several species. Thus, it was aimed to report the use of the polymethylmethacrylate (PMMA) to fill the orbitalcavity after exenteration in a dog with conjunctival HSA.Case: A 10-year-old male Pitbull dog was assisted, with a clinical history of growth of a reddish tissue in the left eye, causingconstant hemorrhage, with an evolution of two months. At ophthalmic examination of the left eye, in the temporal bulbar conjunctive was found a reddish neoformation, with an irregular surface, measuring approximately 4 x 2 x 2 cm. The biopsy andaspiration cytology of the neoformation, revealed cells that inferred that they were those of conjunctival HSA. The hemogramrevealed normocytic anemia; the biochemical profile was with the standards of normality and no metastasis were found in theultrasonography and X-ray. The treatment of choice was the exenteration. Initially, the palpebral borders were approximatedusing continuous simple suture wit monofilament nylon thread. An incision was made in the skin, along the orbital rim andthen was performed a rhombus dissection of the conjunctive and all the extraocular muscles. Next, the eye globe, together withthe neoplasia, soft tissues of the orbital cavity and third eyelid were removed. The PMMA was obtained from a mixture of thepowder (polymer) and of the liquid (monomer) in the ratio of 1:1 in a sterile recipient, in...
Assuntos
Animais , Cães , Implantes Orbitários/veterinária , Olho Artificial/veterinária , Polimetil Metacrilato , Resinas Acrílicas , Hemangiossarcoma/cirurgia , Hemangiossarcoma/veterinária , Neoplasias Oculares/cirurgia , Neoplasias Oculares/veterináriaResumo
Background: The hemangiossarcoma (HSA) is a malignant tumor originated from the alterations of vascular endothelialcells. As it has an aggressive behavior, it is indicated, as initial treatment, wide surgical excision, such as the exenteration, which results in the surgical removal of the ocular bulb and adjacent tissues. The referred technique has as a resulta concave orbit and aesthetically unacceptable. Therefore, various materials, used as orbital implants, have been studiedand used in several species. Thus, it was aimed to report the use of the polymethylmethacrylate (PMMA) to fill the orbitalcavity after exenteration in a dog with conjunctival HSA.Case: A 10-year-old male Pitbull dog was assisted, with a clinical history of growth of a reddish tissue in the left eye, causingconstant hemorrhage, with an evolution of two months. At ophthalmic examination of the left eye, in the temporal bulbar conjunctive was found a reddish neoformation, with an irregular surface, measuring approximately 4 x 2 x 2 cm. The biopsy andaspiration cytology of the neoformation, revealed cells that inferred that they were those of conjunctival HSA. The hemogramrevealed normocytic anemia; the biochemical profile was with the standards of normality and no metastasis were found in theultrasonography and X-ray. The treatment of choice was the exenteration. Initially, the palpebral borders were approximatedusing continuous simple suture wit monofilament nylon thread. An incision was made in the skin, along the orbital rim andthen was performed a rhombus dissection of the conjunctive and all the extraocular muscles. Next, the eye globe, together withthe neoplasia, soft tissues of the orbital cavity and third eyelid were removed. The PMMA was obtained from a mixture of thepowder (polymer) and of the liquid (monomer) in the ratio of 1:1 in a sterile recipient, in...(AU)
Assuntos
Animais , Cães , Resinas Acrílicas , Polimetil Metacrilato , Implantes Orbitários/veterinária , Olho Artificial/veterinária , Hemangiossarcoma/cirurgia , Hemangiossarcoma/veterinária , Neoplasias Oculares/cirurgia , Neoplasias Oculares/veterináriaResumo
Fraturas ósseas podem ser corrigidas com a utilização de fixadores esqueléticos externos (FEE), método de estabilização bastante comum. Para tanto, têm-se utilizado barras conectoras de polimetilmetacrilato (PMMA) sem critério de diâmetro, as quais podem quebrar, se ficarem muito delgadas, ou ocasionar incômodo, quando muito pesadas e volumosas. O objetivo deste trabalho foi testar, por meio de ensaio biomecânico de compressão axial e flexão, qual é o diâmetro ideal da barra conectora de PMMA, correlacionado com o diâmetro ósseo para utilização em FEE tipo Ia. Utilizaram-se 24 úmeros para se realizarem medidas de comprimento, diâmetro, circunferência e ensaios biomecânicos. Após, foram confeccionadas barras de 1,5 vezes a média do diâmetro ósseo (grupo I), do mesmo diâmetro ósseo (grupo II) e de 0,5 vezes o diâmetro (grupo III). Com os resultados obtidos ao se compararem os valores dos ossos com os dos grupos II e III, verificou-se que as barras conectoras do grupo II mostraram-se mais resistentes do que o tecido ósseo no ensaio de compressão. No ensaio de flexão, os ossos resistiram mais quando comparados aos grupos II e III, sendo 4,3 vezes mais resistentes do que o grupo III nesse mesmo ensaio mecânico. Os resultados permitem um direcionamento para confecção de barras considerando-se o diâmetro ósseo como referência.(AU)
Bone fractures can be corrected from external skeletal fixators (ESF) in a fairly common internal stabilization method, in which connector bars polymethylmethacrylate (PMMA) is used. PMMA is used without criterion of diameter, and it can break if it is too thin or too heavy. It can be uncomfortable when bulky. The aim of this study was to test, through biomechanical axial compression and bending which is the ideal connector bar diameter PMMA, correlated to bone diameter for use in type Ia ESF. Twenty-four humerus were used to make measurements of length, diameter, circumference, and biomechanical testing. After the bars confected with 1.5 times the average diameter of the bone (group I), the same diameter (group II) and 0.5 times the diameter of the bone (group III). With the obtained results, using GII and GIII results, it was observed that the connector bars in group II were more resistant than the bones in the compression test. In the bending test, the bones resisted flexion strength when compared to group III and the group II was 4.3 times more resistant than group III in the same mechanical test. The results allow a direction for making bars considering bone diameter as a reference.(AU)
Assuntos
Animais , Fixação de Fratura/estatística & dados numéricos , Fraturas por Compressão/veterinária , Suínos/lesões , Fenômenos Biomecânicos , Polimetil MetacrilatoResumo
Fraturas ósseas podem ser corrigidas com a utilização de fixadores esqueléticos externos (FEE), método de estabilização bastante comum. Para tanto, têm-se utilizado barras conectoras de polimetilmetacrilato (PMMA) sem critério de diâmetro, as quais podem quebrar, se ficarem muito delgadas, ou ocasionar incômodo, quando muito pesadas e volumosas. O objetivo deste trabalho foi testar, por meio de ensaio biomecânico de compressão axial e flexão, qual é o diâmetro ideal da barra conectora de PMMA, correlacionado com o diâmetro ósseo para utilização em FEE tipo Ia. Utilizaram-se 24 úmeros para se realizarem medidas de comprimento, diâmetro, circunferência e ensaios biomecânicos. Após, foram confeccionadas barras de 1,5 vezes a média do diâmetro ósseo (grupo I), do mesmo diâmetro ósseo (grupo II) e de 0,5 vezes o diâmetro (grupo III). Com os resultados obtidos ao se compararem os valores dos ossos com os dos grupos II e III, verificou-se que as barras conectoras do grupo II mostraram-se mais resistentes do que o tecido ósseo no ensaio de compressão. No ensaio de flexão, os ossos resistiram mais quando comparados aos grupos II e III, sendo 4,3 vezes mais resistentes do que o grupo III nesse mesmo ensaio mecânico. Os resultados permitem um direcionamento para confecção de barras considerando-se o diâmetro ósseo como referência.(AU)
Bone fractures can be corrected from external skeletal fixators (ESF) in a fairly common internal stabilization method, in which connector bars polymethylmethacrylate (PMMA) is used. PMMA is used without criterion of diameter, and it can break if it is too thin or too heavy. It can be uncomfortable when bulky. The aim of this study was to test, through biomechanical axial compression and bending which is the ideal connector bar diameter PMMA, correlated to bone diameter for use in type Ia ESF. Twenty-four humerus were used to make measurements of length, diameter, circumference, and biomechanical testing. After the bars confected with 1.5 times the average diameter of the bone (group I), the same diameter (group II) and 0.5 times the diameter of the bone (group III). With the obtained results, using GII and GIII results, it was observed that the connector bars in group II were more resistant than the bones in the compression test. In the bending test, the bones resisted flexion strength when compared to group III and the group II was 4.3 times more resistant than group III in the same mechanical test. The results allow a direction for making bars considering bone diameter as a reference.(AU)
Assuntos
Animais , Fixação de Fratura , Fraturas por Compressão/veterinária , Suínos/lesões , Fenômenos Biomecânicos , Polimetil MetacrilatoResumo
Pelvic fractures correspond to 20 to 30 % of the fractures observed in dogs. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques is of utmost importance to assess the best way of treating these injuries. This study compared, biomechanically, the use of a dynamic compression plate (DCP) and screws (group 1) or screws and polymethylmethacrylate (PMMA) (group 2) to stabilize an iliac fracture using a static test. Sixteen canine synthetic hemi-pelvises (test specimens) with a transverse iliac osteotomy were used. After fixation with implants, a load was applied to the acetabulum until failure. Group 1 maximal compressive load was 133.9±18.60 N, displacement at yield 21.10±3.59mm and stiffness 125.22±12.25N/mm. Group 2 maximal compressive load was 183.50±27.38N, displacement at yield 16.66±5.42mm and stiffness 215.68±33.34N/mm. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate since it resisted a greater load in all test specimens.(AU)
As fraturas da pelve são frequentes em cães, correspondendo a 20-30% das fraturas encontradas na espécie. A grande maioria delas é tratada cirurgicamente, principalmente aquelas que apresentam desvio ósseo. O estudo mecânico das técnicas cirúrgicas é de extrema importância para avaliação da melhor maneira de tratamento destas lesões. O objetivo deste estudo foi comparar, do ponto de vista biomecânico, a fixação das fraturas do ílio utilizando uma placa de compressão dinâmica ou parafusos associados ao polimetilmetacrilato, por meio de um teste estático. Foram utilizadas 16 hemipelves caninas de origem sintética, nas quais uma osteotomia transversa foi realizada no corpo do ílio. As fixações foram divididas em dois grupos: fixação com placa de compressão dinâmica e parafusos (grupo1) ou parafusos associados ao polimetilmetacrilato (grupo 2). Posteriormente à fixação dos implantes foi aplicada uma carga no acetábulo de cada corpo de prova até a falha. O grupo 2 apresentou força máxima de aplicação de carga a média de 133.9±18.60N, deflexão 21.10±3.59mm e rigidez 125.22±12.25N/mm. O grupo 2 apresentou força máxima de aplicação de carga a média de 183.50±27.38N, deflexão 16.66±5.42mm e rigidez 215.68±33.34N/mm. A estabilização com o polimetilmetacrilato mostrou ser mais resistente, pois resistiu a uma maior quantidade de carga em relação à placa de compressão dinâmica, em todos os corpos de prova.(AU)
Assuntos
Animais , Fixadores Internos/veterinária , Fixação Interna de Fraturas/veterinária , Pelve/lesões , Fenômenos Biomecânicos , Polimetil Metacrilato/uso terapêutico , Poliuretanos , Fraturas Ósseas/cirurgiaResumo
Pelvic fractures correspond to 20 to 30 % of the fractures observed in dogs. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques is of utmost importance to assess the best way of treating these injuries. This study compared, biomechanically, the use of a dynamic compression plate (DCP) and screws (group 1) or screws and polymethylmethacrylate (PMMA) (group 2) to stabilize an iliac fracture using a static test. Sixteen canine synthetic hemi-pelvises (test specimens) with a transverse iliac osteotomy were used. After fixation with implants, a load was applied to the acetabulum until failure. Group 1 maximal compressive load was 133.9±18.60 N, displacement at yield 21.10±3.59mm and stiffness 125.22±12.25N/mm. Group 2 maximal compressive load was 183.50±27.38N, displacement at yield 16.66±5.42mm and stiffness 215.68±33.34N/mm. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate since it resisted a greater load in all test specimens.(AU)
As fraturas da pelve são frequentes em cães, correspondendo a 20-30% das fraturas encontradas na espécie. A grande maioria delas é tratada cirurgicamente, principalmente aquelas que apresentam desvio ósseo. O estudo mecânico das técnicas cirúrgicas é de extrema importância para avaliação da melhor maneira de tratamento destas lesões. O objetivo deste estudo foi comparar, do ponto de vista biomecânico, a fixação das fraturas do ílio utilizando uma placa de compressão dinâmica ou parafusos associados ao polimetilmetacrilato, por meio de um teste estático. Foram utilizadas 16 hemipelves caninas de origem sintética, nas quais uma osteotomia transversa foi realizada no corpo do ílio. As fixações foram divididas em dois grupos: fixação com placa de compressão dinâmica e parafusos (grupo1) ou parafusos associados ao polimetilmetacrilato (grupo 2). Posteriormente à fixação dos implantes foi aplicada uma carga no acetábulo de cada corpo de prova até a falha. O grupo 2 apresentou força máxima de aplicação de carga a média de 133.9±18.60N, deflexão 21.10±3.59mm e rigidez 125.22±12.25N/mm. O grupo 2 apresentou força máxima de aplicação de carga a média de 183.50±27.38N, deflexão 16.66±5.42mm e rigidez 215.68±33.34N/mm. A estabilização com o polimetilmetacrilato mostrou ser mais resistente, pois resistiu a uma maior quantidade de carga em relação à placa de compressão dinâmica, em todos os corpos de prova.(AU)
Assuntos
Animais , Cães , Fenômenos Biomecânicos , Fixação Interna de Fraturas/veterinária , Fixadores Internos/veterinária , Pelve/lesões , Polimetil Metacrilato/uso terapêutico , Poliuretanos , Fraturas Ósseas/cirurgiaResumo
As afecções ortopédicas com perda de tecido ósseo são um desafio não só na medicina veterinária mas também na medicina humana. Analisou a interface entre compósito, constituído de esferas de quitosana e polimetilmetacrilato em falha óssea (leito receptor) de tíbia de coelhos, por meio de técnica radiológica, avaliação macroscópica e pela microscopia eletrônica de varredura, em diferentes tempos. Foram utilizados 12 coelhos adultos da raça Nova Zelândia, divididos em quatro Grupos Experimentais (E1, n=3; E2, n=3; E3, n=3 e E4, n=3), que tiveram as falhas ósseas das tibiais direitas preenchidas com compósito, e avaliadas no pós-operatório imediato, aos 30, 60 e 90 e 120 dias. Dos compósitos implantados nas tíbias de coelhos, apenas dois permaneceram em seus leitos receptores, enquanto que os demais se encontravam encapsulados no tecido subcutâneo. As esferas de quitosana, presentes nas superfícies dos biomateriais implantados, que mantiveram contato direto com o leito receptor de tíbias de coelhos apresentavam-se preservadas e não integraram ao tecido ósseo. Diante disso, para melhor compreensão do comportamento da quitosana como substituto ósseo, novas pesquisas serão necessárias.(AU)
Orthopedic diseases with bone loss are challenging in both veterinary and human medicine. The aim of this investigation was to analyze and compare the reactions at the interface between the composite, made of chitosan and polymethylmethacrylate, and the bone defect (receptor site) of the rabbits tibia through radiological and microscopic techniques and by scanning electron microscopy, in different periods. Twelve adult New Zealand rabbits were divided into four experimental groups (E1, n=3; E2, n=3; E3, n=3 and E4, n=3), which had the right tibial bone defects filled with the composite, and evaluated in the immediate postoperative, 30, 60, 90 and 120 days. Composite implanted in the tibia of rabbits, only two remained in their beds receivers, while the remaining were encapsulated in the subcutaneous tissue. Spheres of chitosan present in the biomaterial that has been deployed and were in direct contact with the bone defect, were preserved, however, were not integrated into the bone tissue. Therefore, to understand the behavior of chitosan as a bone substitute, further research is needed.(AU)
Assuntos
Animais , Coelhos , Tíbia/cirurgia , Fraturas da Tíbia/veterinária , Resinas Compostas , Substitutos Ósseos/análise , Polimetil Metacrilato , QuitosanaResumo
As afecções ortopédicas com perda de tecido ósseo são um desafio não só na medicina veterinária mas também na medicina humana. Analisou a interface entre compósito, constituído de esferas de quitosana e polimetilmetacrilato em falha óssea (leito receptor) de tíbia de coelhos, por meio de técnica radiológica, avaliação macroscópica e pela microscopia eletrônica de varredura, em diferentes tempos. Foram utilizados 12 coelhos adultos da raça Nova Zelândia, divididos em quatro Grupos Experimentais (E1, n=3; E2, n=3; E3, n=3 e E4, n=3), que tiveram as falhas ósseas das tibiais direitas preenchidas com compósito, e avaliadas no pós-operatório imediato, aos 30, 60 e 90 e 120 dias. Dos compósitos implantados nas tíbias de coelhos, apenas dois permaneceram em seus leitos receptores, enquanto que os demais se encontravam encapsulados no tecido subcutâneo. As esferas de quitosana, presentes nas superfícies dos biomateriais implantados, que mantiveram contato direto com o leito receptor de tíbias de coelhos apresentavam-se preservadas e não integraram ao tecido ósseo. Diante disso, para melhor compreensão do comportamento da quitosana como substituto ósseo, novas pesquisas serão necessárias.(AU)
Orthopedic diseases with bone loss are challenging in both veterinary and human medicine. The aim of this investigation was to analyze and compare the reactions at the interface between the composite, made of chitosan and polymethylmethacrylate, and the bone defect (receptor site) of the rabbits tibia through radiological and microscopic techniques and by scanning electron microscopy, in different periods. Twelve adult New Zealand rabbits were divided into four experimental groups (E1, n=3; E2, n=3; E3, n=3 and E4, n=3), which had the right tibial bone defects filled with the composite, and evaluated in the immediate postoperative, 30, 60, 90 and 120 days. Composite implanted in the tibia of rabbits, only two remained in their beds receivers, while the remaining were encapsulated in the subcutaneous tissue. Spheres of chitosan present in the biomaterial that has been deployed and were in direct contact with the bone defect, were preserved, however, were not integrated into the bone tissue. Therefore, to understand the behavior of chitosan as a bone substitute, further research is needed.(AU)
Assuntos
Animais , Coelhos , Tíbia/cirurgia , Fraturas da Tíbia/veterinária , Resinas Compostas , Substitutos Ósseos/análise , Polimetil Metacrilato , QuitosanaResumo
Tibiotarsal fractures are common in birds because in most birds this is the longest, most exposed bone in the leg. Transverse fractures are most common and rotational and shear forces must be stabilized in order to achieve good bone regeneration. A 230g male Slender-billed Parakeet or Choroy parakeet (Enicognathus leptorhynchus), with more than five years of age, was received with non-weight bearing lameness with 24 hours duration. X-rays were taken, and these revealed a closed, complete, non-comminuted transverse fracture of the distal diaphysis of the left tibiotarsal bone. Fixation was planned with 10-minute fast-setting epoxy putty. In order to assess the temperature of polymerization of the epoxy dough and the possibility of heat-bone necrosis, the temperature was recorded every 30 seconds for 12 minutes with three different amounts of the epoxy material in an ex vivo test. The temperature of the pieces reached a peak of 50-60ºC, where the highest peak corresponds to the highest amount of material. When approximately 6g of putty were used, the peak temperature reached only 51ºC. This peak changed to 58ºC when 4 times more epoxy was mixed and measured. If the temperature of the pins inserted in the bone exceeds 70ºC, bone necrosis could occur. In light of these results, the fracture was treated with 6 g of epoxy putty that was allowed to polymerize over a 1A 2/2 external skeletal fixation, with 1-mm pins bent at 90º and joined together with cerclage wire. At 6 weeks after surgery the bird had formed a good primary bone callus, and the external fixators were therefore removed. With this approach a satisfactory recovery of the patient was achieved with normal use of the affected limb(AU)
Fraturas tibiotársicas são comuns em aves, pois, na maioria das aves, o tibiotarso é o osso mais longo e exposto nesses animais. Fraturas transversais são mais comuns, sendo que as forças de rotação e cisalhamento devem ser estabilizadas de modo a alcançar uma boa regeneração óssea. Um periquito macho do tipo psitacídeo de 230g, com mais de 5 anos, foi recebido apresentando claudicação a 24 horas não devido a transferência de carga. Os exames radiográficos revelaram uma fratura fechada completa, não triturada, transversal de diáfise distal do osso esquerdo tibiotársico. A fixação foi feita com massa epóxi de endurecimento rápido (10 minutos). A fim de avaliar a temperatura de polimerização da massa epóxi e a possibilidade de necrose desses ossos, a temperatura foi registrada a cada 30 segundos durante 12 minutos, com três quantidades diferentes de epóxi em teste in vivo. A temperatura das amostras fragmentadas atingiu um pico de 50-60ºC, em que o pico mais elevado corresponde à maior quantidade de massa epóxi. Quando foram utilizados cerca de 6g de massa de vidraceiro, o pico de temperatura foi de apenas 51ºC. Esse pico foi alterado para 58ºC quando se aumentou a quantidade de massa epóxi quatro vezes. Se a temperatura dos pinos inseridos no osso for superior a 70ºC, pode ocorrer necrose do osso. À luz desses resultados, a fratura foi tratada com 6g de massa epóxi deixada polimerizar sobre uma fixação externa, em configurações 1A 2/2 usando pinos de 1mm, dobrados em 90º e unidos com fios de cerclage. Após 6 semanas da cirurgia, o pássaro tinha formado um calo ósseo primário, sendo os fixadores externos removidos. Com essa abordagem, conclui-se que houve a restauração das funções normais do membro e total recuperação da ave(AU)
Assuntos
Animais , Periquitos/lesões , Polimetil Metacrilato/análise , Ossos do Tarso/lesões , Fixação de Fratura/veterinária , Fixadores Externos/veterináriaResumo
Foi realizada falha segmentar com 6mm de diâmetro na região metafisária medial de tíbias de 12 coelhos, onde foi implantado uma associação de micro e macrofragmentos de matriz óssea cortical heteróloga fragmentada conservada em glicerina (98%) e polimetilmetacrilato autoclavados, para a sua reconstrução, e avaliados radiológica e macroscopicamente aos 30, 60, 90 e 120 dias. Houve adesão, em relação ao tempo, dos micro e macrocompósitos ao leito receptor, em 100% dos casos, mostrando ser biologicamente biocompatível, pois promoveram a reparação de falhas ósseas, sem sinais de infecção, migração e/ou rejeição, podendo, dessa forma, ser mais uma opção como substituto para preencher grandes defeitos ósseos.(AU)
A segmental defect of 6mm diameter was performed in the medial metaphyseal region of the tibia of 12 rabbits. For the bone defect reconstruction there was implanted a combination of micro and macro fragments of heterologous fragmented cortical bone matrix preserved in glycerin (98%) and polymethylmethacrylate, both autoclaved. Radiological and macroscopic evaluation was performed at 30, 60, 90 and 120 days. Adhesion in relation to time of the micro and macro composites to the recipient bed was observed in 100% of the cases. This showed that this implant is biologically biocompatible, since it promoted bone defects repair, with no signs of infection, migration and/or rejection. In this way, this implant can be classified as one more option of substitute to fill large bone defects.(AU)
Assuntos
Animais , Coelhos/lesões , Tíbia/lesões , Matriz Óssea , Polimetil Metacrilato/uso terapêutico , Materiais Biocompatíveis/uso terapêutico , Tecnologia RadiológicaResumo
As fraturas são afecções bastante frequentes na rotina clínica de cães e gatos, e vários métodos para sua estabilização são propostos na literatura. Neste trabalho, avaliou-se uma nova técnica de estabilização das fraturas femorais e umerais constituída pelo uso de pino intramedular e fixação de pinos paracorticais com polimetilmetacrilato. Foram utilizados doze animais (seis gatos e seis cães), sendo que três deles apresentaram fratura de úmero e os demais apresentaram fratura femoral. A cicatrização óssea foi avaliada através do acompanhamento radiográfico trinta, sessenta e noventa dias após o procedimento cirúrgico. Observou-se imediatamente após a implantação da técnica (período transoperatório) que o método neutralizou eficientemente as forças de rotação, flexão, deslocamento axial e cisalhamento, proporcionando graus de alinhamento e aposição adequados. No entanto, ao longo do tempo, a estabilidade requerida não permaneceu, gerando, em alguns animais, retardo na união óssea. Além disso, foram observados fenômenos de deiscência de ferida, perda da integridade dos implantes e osteomielite. Essa técnica de estabilização de fraturas é aplicável apenas a fraturas transversas ou levemente oblíquas e pode ser considerada pouco eficiente, diante do número de vicissitudes, observadas durante a pesquisa.
Fractures are very frequent affections in clinical routine of dogs and cats, and several methods of stabilizing them are proposed in the literature. In this work, a new technique for stabilization of femoral and humeral fractures constituted by the use of intramedullary pin and paracortical pins fixed with polymethylmethacrylate was evaluated. Twelve animals (six cats and six dogs) were used. Three of them had humeral fracture and the others had femoral fractures. The bone healing was evaluated by radiographic monitoring 30, 60 and 90 days after the surgery. It was observed, immediately after the deployment of the technology (trans-operative period), that the method effectively neutralized the forces of rotation, bending, shear and axial displacement, providing degrees of alignment and adequate affixing; however, over time, the required stability did not remain, causing delay in bone union of some animals. Moreover, wound dehiscence, integrity loss of the implants and osteomyelitis were observed. This approach to fractures stabilization is applicable only to transverse fractures or slightly oblique ones, and can be considered inefficient, facing the number of imperfections observed during the research.
Assuntos
Gatos , Cães , Cães/classificação , Fraturas do Fêmur/reabilitação , Gatos/classificação , Pinos Ortopédicos , Polimetil Metacrilato/administração & dosagemResumo
Esforço de tração foi aplicado perpendicularmente ao eixo do bico e para realização do ensaio foi utilizado um dinamômetro. O bico íntegro fraturou quando submetido a uma tração de 270,40 N, com deslocamento de 22,59mm. Para a fixação dos bicos fraturados foi utilizada resina acrílica e a área compreendeu uma faixa com 2,0 cm de largura. O segundo bico ensaiado apresentou resistência até 69.75 N. O bico submetido a condicionamento ácido resistiu a uma força de 63,29 N. Outros dois novos ensaios foram realizados, preenchendo-se toda a superfície da rinoteca. Aquele não submetido ao condicionamento ácido resistiu até 134,40 N e, aquele submetido ao condicionamento ácido, resistiu até 101,50 N. No presente trabalho não se observou correlação estatística e, conseqüentemente, diferença entre os procedimentos com utilização prévia de condicionamento ácido e aqueles sem a utilização do mesmo.(AU)
Traction effort was applied perpendicularly to the axis of toucan beaks and for accomplishment of the essay a dynamometer was used. The beak was completely fractured when submitted to traction of 270.40 N. For fixation of the fractured beaks acrylic resin was applied using a strip of 2.0cm of width. The second beak presented resistance up to 69.75 N. The third beak was submitted to acid conditioning and resisted to force of 63.29 N. Other two new tests were accomplished the whole surface of the rhinotheca filled out. The fourth beak was not submitted to the acid attack and it resisted up to 134.40 N, and the fifth was submitted to the acid etch and it resisted up to 101.50 N. The present work did not observe statistical correlation and, consequently, differences among the procedures with previous use of acid attack and those without the use of the same.(AU)
Assuntos
Animais , Fenômenos Biomecânicos/métodos , Aderências Teciduais , Resinas Acrílicas , Polimetil Metacrilato , Aves , BicoResumo
A redução das lesões decorrentes de um ato cirúrgico é um objetivo comum aos cirurgiões. Neste relato é descrita uma técnica minimamente invasiva, associando suturas circuncostais à placa pré-moldada de polimetilmetacrilato, como método de estabilização de múltiplas fraturas costais, sem anecessidade de realização de toracotomia. Técnica que possibilitou adequada redução e estabilizaçãodos fragmentos costais.AU
The reduction of injuries resulting from a surgical procedure is a common goal for surgeons. Therefore in this report aimed at describing minimally invasive technique involving cicumcostal suturestrough preformed plate of polymethylmethacrylate as a method for stabilizing multiple rib fractureswithout the need for thoracotomy. The proposed technique allowed adequate reduction and stabilization of the costal fragments.AU
Assuntos
Animais , Cães , Cães/cirurgia , Fixação de Fratura/veterinária , Ferimentos e Lesões/veterinária , Polimetil Metacrilato/uso terapêuticoResumo
A redução das lesões decorrentes de um ato cirúrgico é um objetivo comum aos cirurgiões. Neste relato é descrita uma técnica minimamente invasiva, associando suturas circuncostais à placa pré-moldada de polimetilmetacrilato, como método de estabilização de múltiplas fraturas costais, sem anecessidade de realização de toracotomia. Técnica que possibilitou adequada redução e estabilizaçãodos fragmentos costais.
The reduction of injuries resulting from a surgical procedure is a common goal for surgeons. Therefore in this report aimed at describing minimally invasive technique involving cicumcostal suturestrough preformed plate of polymethylmethacrylate as a method for stabilizing multiple rib fractureswithout the need for thoracotomy. The proposed technique allowed adequate reduction and stabilization of the costal fragments.