Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 420
Filtrar
1.
Arq. bras. med. vet. zootec. (Online) ; 75(4): 571-590, July-Aug. 2023. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1447355

Resumo

The present study aimed to evaluate and compare the palmar and plantar digital arteries of 10 horses and 10 mules through B-mode and spectral Doppler ultrasound. Likewise, compare the plantar arteries of the pelvic limbs with the palmar arteries of the thoracic limbs, in addition to verifying the differences of the digital arteries in the contralateral limbs (right and left) in horses and mules using B-mode and spectral Doppler ultrasonography. The evaluated parameters were the diameter and the intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI), peak of systolic velocity (pSV), final diastolic velocity (fDV) and mean velocity (MV) of the lateral and medial palmar and plantar arteries digital in healthy horses and mules. The horses presented higher diameters values, IMT, pSV, fDV and MV in comparison to the mules. The variables RI and PI also presented differences between horses and mules. Also, both species showed higher values in the variables of B-mode and Doppler ultrasonography in the thoracic limbs. Differences were also detected in the comparison between the limb sides (right and left) in the two modalities. The B-Mode and spectral Doppler ultrasound techniques are viable tools to identify differences in the palmar and plantar digital arteries in healthy horses and mules, highlight the differences between the thoracic and pelvic limbs and their respective sides (right and left) as well.


O presente estudo teve como objetivo avaliar e comparar as artérias digitais palmares e plantares de 10 equinos e 10 muares, por meio de ultrassom modo B e Doppler espectral. Da mesma forma, buscou-se comparar as artérias plantares dos membros pélvicos com as artérias palmares dos membros torácicos, além de se verificarem as diferenças das artérias digitais nos membros contralaterais (direito e esquerdo) em equinos e mulas, por meio de ultrassonografia modo B e Doppler espectral. Os parâmetros avaliados foram o diâmetro e a espessura médio-intimal (EMI), o índice de resistividade (IR), o índice de pulsatilidade (IP), o pico de velocidade sistólica (pVS), a velocidade diastólica final (VDf) e a velocidade média (VM) das artérias palmares e plantares lateral e medial digitais em equinos e muares sadios. Os equinos apresentaram maiores valores de diâmetros, EMI, pVS, VDf e VM em comparação aos muares. As variáveis IR e IP também apresentaram diferenças entre equinos e muares. Cavalos e mulas apresentaram maiores valores nas variáveis de ultrassonografia modo B e Doppler nos membros torácicos. Também foram detectadas diferenças na comparação entre os lados dos membros (direito e esquerdo) nas duas modalidades. As técnicas de ultrassom modo-B e Doppler espectral são ferramentas viáveis para identificar diferenças nas artérias digitais palmares e plantares em equinos e muares saudáveis, bem como para destacar as diferenças entre os membros torácicos e pélvicos e seus respectivos lados (direito e esquerdo).


Assuntos
Animais , Artérias , Ultrassonografia Doppler/veterinária , Cavalos , Locomoção
2.
Rev. bras. reprod. anim ; 47(2): 267-274, abr.-jun. 2023.
Artigo em Português | VETINDEX | ID: biblio-1435388

Resumo

A ultrassonografia (US) Doppler colorido fornece uma ferramenta não invasiva valiosa para detectar e monitorar mudanças dinâmicas na rede vascular e fluxo sanguíneo em vários órgãos e tecidos reprodutivos. Em apoio as biotécnicas da reprodução animal assistida, a US Doppler colorido tem mostrada alta eficiência no monitoramento funcional das estruturas ovarianas. A previsão de respostas ovarianas e produções embrionária em ovinos pela identificação de sinais Doppler na parede folicular já se mostrou eficiente. A aplicação da US Doppler colorido para a identificação da funcionalidade do tecido luteal é ainda maior, desde acompanhamentos fisiológicos e diagnósticos de disfunções luteais até ampla aplicação em conjunto as diferentes biotécnicas reprodutivas. Destaca-se em ovelhas e cabras, a aplicação comercial da US Doppler colorido para o diagnóstico de gestação precoce, de disfunções luteais, de determinação de respostas ovarianas em fêmeas doadoras e receptoras de embriões, para identificar efeitos luteotrófico de estratégias hormonais, e ainda para amparar as estratégias de ressincronização de estro.(AU)


Color Doppler ultrasonography (US) provides a valuable non-invasive tool for detecting and monitoring dynamic changes in the vascular network and blood flow in various reproductive organs and tissues. In support of assisted animal reproduction biotechniques, color Doppler US has shown high efficiency in the functional monitoring of ovarian structures. The prediction of ovarian responses and embryonic production in sheep by identifying Doppler signals in the follicular wall has already proved to be efficient. The application of color Doppler US for identifying the functionality of the luteal tissue is even greater, from physiological monitoring and diagnosis of luteal dysfunctions to wide application together with different reproductive biotechniques. It stands out in sheep and goats, the commercial application of color Doppler US for the diagnosis of early pregnancy, luteal dysfunctions, determination of ovarian responses in embryo donor and recipient females, to identify luteotrophic effects of hormonal strategies, and even to support estrus resynchronization strategies.(AU)


Assuntos
Animais , Feminino , Cabras/fisiologia , Ovinos/fisiologia , Ultrassonografia Doppler/instrumentação , Corpo Lúteo/diagnóstico por imagem , Folículo Ovariano/diagnóstico por imagem
3.
Acta sci. vet. (Impr.) ; 51(supl.1): Pub. 857, 2023. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1434541

Resumo

Background: Portosystemic shunt (PSS), an alteration commonly found in toy dogs, is caused by an anastomosis between the systemic and portal circulation, interfering with the metabolism of several toxins. It can be of congenital or acquired origin and is classified as intra- or extrahepatic. Clinical signs include the gastrointestinal tract, nervous system, and urinary system according to the fraction of the shunt. It is diagnosed by several imaging tests and exploratory laparotomy. Therapy involves drug therapy and/or surgical correction of the anomalous vessels. Thus, the aim is to present an unusual case of extrahepatic cPSS originating from the left gastric vein and insertion into the azygos vein. Case: A 2-year-old female toy poodle, spayed, weighing 2.7 kg was treated with a history of recurrent cystitis and neurological signs such as focal seizures, ataxia, tremors, blindness, lethargy, head pressing, and compulsive gait. Complementary tests revealed normochromic microcytic anemia, neutrophilia-induced leukocytosis, monocytosis, and lymphopenia. Biochemical analysis revealed hypoproteinemia due to hypoglobulinemia, an increase in alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, and gamma-glutamyl transferase, and a decrease in urea. In the urinalysis, ammonium biurate crystals were detected, and Doppler ultrasound revealed microhepathy and the presence of an anomalous gastrosplenic vein inserted into the azygos vein, a finding compatible with the congenital extrahepatic PSS. Abdominal tomography confirmed vascular deviation with a sinuous path originating from the left gastric and splenic veins, inserting into the azygos vein, measuring approximately 5.95 cm in length. Cranial tomography revealed changes consistent with hepatic encephalopathy. Drug therapy was performed with hydration, liver chow, lactulose, probiotics, metronidazole, S-adenosyl-L-methionine, and ursodeoxycholic acid, and after 15 days, surgery was performed to place a 3.5 mm ameroid constrictor ring for gradual occlusion of the anomalous vessel. The animal recovered well, and a control abdominal ultrasound was repeated 30 days after the procedure, noting that the constrictor had not yet fully occluded the deviation. Doppler imaging revealed a favorable evolution with an increase in the diameter of the portal vein in the hepatopetal direction. The patient was followed-up for a year and had a normal and healthy life. Discussion: Extrahepatic PSS is frequently diagnosed in purebred and toy dogs, commonly occurring between the portal vein and one of its tributaries, with a lower frequency of anomalous vessels between the azygos veins, as in the present report. The patient's age and clinical signs were compatible with the disease, in addition to ammonia biurate crystals and hematological and biochemical alterations. The neurological clinical signs observed were compatible with hepatic encephalopathy secondary to congenital PSS. The imaging examinations facilitated the identification of the extrahepatic vascular anomaly, with the tomography being more accurate and helping in proper surgical planning. Clinical treatment should be performed for presurgical stabilization, and occlusion can be performed by placing cellophane bands or an ameroid constrictor, which is the technique of choice for congenital PSS, as it allows for slow constriction to avoid acute portal hypertension, as in this case, emphasizing that anesthesia in animals with portosystemic shunts must be performed with care.


Assuntos
Animais , Feminino , Cães , Veia Ázigos/cirurgia , Derivação Portossistêmica Cirúrgica/veterinária , Ductos Biliares Extra-Hepáticos , Ultrassonografia Doppler/veterinária
4.
Pesqui. vet. bras ; 43: e07212, 2023. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1507030

Resumo

Mammary neoplasia represents the most frequently diagnosed type of neoplasia in bitches. Although surgical removal is the procedure of choice for therapeutic management, chemotherapy protocols appear as important allies and adjuvants. Despite the great advances that have occurred in the field of cancer therapy, the systemic repercussions of these drugs still impose important limitations on their use. In this sense, the development of increasingly targeted therapeutic protocols and preventive monitoring of patients represent important strategies to avoid possible complications - among them, Acute Kidney Injury (AKI). Routinely, ultrasound evaluation is used to identify morphological or metastatic variations in abdominal cavity organs. Acting complementary to the B-mode evaluation, Doppler mapping proves to be efficient in recognizing alterations in vascular hemodynamics. Therefore, the objective of the present study was to evaluate the use of B-mode and Doppler ultrasound to identify renal morphological and hemodynamic alterations in bitches with mammary neoplasia submitted to adjuvant chemotherapy protocols that associate gemcitabine with carboplatin. Thirteen bitches were included, without distinction of breed and between seven and 13 years of age. The animals were evaluated ultrasonographically at two different times during three consecutive chemotherapy cycles: before (T0) and one and a half hours after each cycle (T1), for 42 days. No morphological changes were observed in B-mode throughout the chemotherapy protocol. However, the Doppler velocimetry indices demonstrated statistical differences before (T0) and after (T1) the administration of the drugs. It was concluded that Doppler ultrasound could be used as a complementary method for monitoring the renal response of patients exposed to nephrotoxic drugs and potentially causing renal injury.


As neoplasias mamárias representam o tipo de neoplasma mais frequentemente diagnosticado em fêmeas da espécie canina. Embora a remoção cirúrgica seja o procedimento de eleição para a conduta terapêutica, os protocolos quimioterápicos aparecem como importantes aliados e adjuvantes. Apesar dos grandes avanços ocorridos na área da terapia oncológica, as repercussões sistêmicas destes fármacos ainda impõem importantes limitações ao seu uso. Neste sentido, o desenvolvimento de protocolos terapêuticos cada vez mais direcionados e o monitoramento preventivo dos pacientes representam estratégias importantes para evitar possíveis complicações - dentre elas, a injúria renal aguda (IRA). Rotineiramente, a avaliação ultrassonográfica é utilizada para identificação de variações morfológicas ou metastáticas em órgãos da cavidade abdominal. Atuando de forma complementar à avaliação em modo-B, o mapeamento Doppler mostra-se eficiente no reconhecimento de alterações na hemodinâmica vascular. Portanto, o objetivo do presente estudo foi avaliar a utilização da ultrassonografia modo-B e Doppler como método para identificação de alterações morfológicas e hemodinâmicas renais em cadelas com neoplasias mamárias submetidas a protocolos quimioterápicos adjuvantes que associam a gencitabina à carboplatina. Foram incluídas 13 fêmeas caninas, sem distinção quanto a raça e com idades entre sete e 13 anos. Os animais foram avaliados ultrassonograficamente em dois momentos distintos durante três ciclos quimioterápicos consecutivos: antes (T0) e uma hora e meia após a realização de cada ciclo (T1), totalizando 42 dias. Não foram observadas alterações morfológicas em modo-B ao longo do protocolo quimioterápico. Entretanto, os índices dopplervelocimétricos demonstraram diferenças estatísticas antes (T0) e após (T1) a administração dos fármacos. Concluiu-se que a ultrassonografia Doppler pode ser utilizada como método complementar para o monitoramento da resposta renal de pacientes expostos a fármacos nefrotóxicos e potencialmente causadores de injúrias renais.


Assuntos
Animais , Feminino , Cães , Neoplasias Mamárias Animais/complicações , Quimioterapia Adjuvante/efeitos adversos , Quimioterapia Adjuvante/veterinária , Doenças do Cão , Injúria Renal Aguda/veterinária , Injúria Renal Aguda/diagnóstico por imagem , Carboplatina , Ultrassonografia Doppler/veterinária , Gencitabina
5.
Acta sci. vet. (Impr.) ; 51(supl.1): Pub. 893, 2023. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1444627

Resumo

Background: A 10-year-old spayed bitch with hip dysplasia was referred for periarticular ultrasound evaluation. A poorly marginated structure of mixed echogenicity, predominantly hypoechoic, with heterogeneous echotexture, was identified in the vastus lateralis muscle of the right pelvic limb with increased stiffness, assessed using acoustic radiation force impulse (ARFI) elastography, compared to that of the adjacent muscle tissues, and intense vascularization by pulsed Doppler and contrast-enhanced ultrasound (CEUS). Guided biopsy was performed to confirm the diagnosis of hemangiosarcoma. The objective of this study was to describe B-mode ultrasound, CEUS, and ARFI findings of hemangiosarcoma in the vastus lateralis musculature of a bitch. Case: A 10-year-old spayed bitch Golden Retriever weighing 36 kg was evaluated for pelvic limb lameness. The patient presented with bilateral pain during hip extension. The primary diagnostic suspicion was degenerative joint disease and secondary hip dysplasia. The patient was referred for imaging evaluation of the hip joints (radiography and ultrasound) under anesthesia. Right lateral and ventrodorsal projections with the pelvic limbs extended were obtained to confirm the diagnosis. In the right pelvic limb, an amorphous hypoechoic structure with irregular contours and heterogeneous echotexture was observed in the vastus lateralis muscle. In ARFI elastography, it was possible to identify differences in tissue stiffness between healthy and compromised portions. Pulsed-wave Doppler evaluation demonstrated an arterial waveform pattern with a peak systolic velocity of 38.8 cm/s, end-diastolic velocity of 6.9 cm/s, pulsatility index of 1.76, and resistive index of 0.82. CEUS study identified a mean peak of 27.26 %, mean time to peak of 39.95 s, and mean transmission time of 49.96 s. The popliteal lymph node was hyperechoic and heterogeneous in B-mode. In ARFI elastography, the average stiffness was 2.52 m/s, and the CEUS obtained an average peak of 19.98%, average time to peak of 17.52 s, and mean transit time of 22.83 s. Doppler assessment revealed no clear vascularization in the lymph node. Thoracic radiography in 3 projections and abdominal ultrasonography were performed. Radiographic evidence of pulmonary nodules was not observed. On abdominal ultrasound evaluation, it was possible to identify changes in the spleen, which presented with splenomegaly, mixed echogenicity, and heterogeneous echotexture. The animal underwent ultrasound-guided muscle biopsy, which confirmed the presence of hemangiosarcoma in the muscle. The bitch was referred for splenectomy and lymphadenectomy of the right popliteal, which confirmed neoplastic involvement of the same neoplasm. Discussion: On B-mode ultrasound, the observed changes were similar to those in a report of hemangiosarcoma in the muscles of the chest wall in dogs, which contributed to the diagnosis. Although it was only one patient, ARFI elastography results suggest that muscle hemangiosarcoma tends to follow the same elastographic characteristics as malignant lesions in other tissues. Additionally, the popliteal lymph node had a stiffness suggestive of malignancy (mean 2.52 m/s) because it presented a similar result and greater elasticity of metastatic axillary lymph nodes in bitches (>2.5 m/s) and women (> 1.44 m/s) with breast tumor. With CEUS, it was possible to identify vascularization in the sentinel lymph node that was not visible by pulsed Doppler, and in muscle mass. The findings of this report provided relevant results on muscle hemangiosarcoma in a bitch and demonstrated that the information obtained with the association of imaging methods supported the malignancy criteria described in other studies.


Assuntos
Animais , Feminino , Cães , Neoplasias Pélvicas/veterinária , Pelve/diagnóstico por imagem , Hemangiossarcoma/diagnóstico por imagem , Ultrassonografia/veterinária , Ultrassonografia Doppler de Pulso/veterinária , Técnicas de Imagem por Elasticidade/veterinária
6.
Rev. bras. zootec ; 52: e20220148, 2023. tab, graf
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1507920

Resumo

ABSTRACT The objective of this study was to evaluate the relationships between preovulatory follicle (POF) and corpus luteum (CL) diameters, and POF and CL vascular perfusion with progesterone production, ovulation, and pregnancy in Nellore cows subjected to timed artificial insemination (TAI). Nellore cows (n = 201) were subjected to ovulation synchronization and later to ultrasound evaluation of POF and CL at the time of insemination (D0) and seven days later (D7), respectively. Females were divided into three categories according to the POF diameter assessed at the time of insemination: small (SF), medium (MF), and large (LF) follicles. The LF group had a greater number and intensity of pixels in the POF ultrasound exam compared with the SF group. The CL flow intensity and progesterone concentration were also higher in the LF group. The SF group showed lower flow intensity and lower ovulation rate compared with the others. When non-pregnant females were compared to pregnant ones, no difference was observed in any of the analyzed variables. The results show for the first time in Nellore cattle the relationship between the size of ovarian structures and blood flow (quantity and intensity) as well as the ability of the CL to produce progesterone. The intensity of the POF pixels proved to be relevant, demonstrating correlations with the size and flow of the CL, which were not found when evaluating only the number of pixels, thus revealing the importance of evaluating complementary characteristics of the flow.

7.
Anim. Reprod. (Online) ; 20(2): e20220110, 2023. tab, ilus, graf
Artigo em Inglês | VETINDEX | ID: biblio-1444259

Resumo

The aim of this study was to investigate uterine involution using ultrasonography techniques during postpartum. Postpartum ultrasonography evaluation (B-mode, color Doppler and Acoustic Radiation Force Impulse elastography) of the uterus was performed by transabdominal approach at immediate after birth and sequentially every 48 hours, during 30 days. The uterine echotexture did not present significant variations (P >0.05) being homogeneous in most evaluations; echogenicity of the uterus increased along the evaluation period (P =0.0452). Progressive and remarkable decrease of the total uterine diameter (UD) were observed (P <0.0001), especially during the first days postpartum. The thickness of uterine wall gradually decreased, as well the endometrial, myometrium and lumen diameters (P <0.0001). Uterine blood flow was assessed by Doppler and decreased during postpartum period, being significantly lower (P=0.0225) on the 30th day of postpartum. Uterine parenchyma presented as homogeneous dark areas (not deformable) on qualitative ultrasound elastography and the means shear velocity values of the uterine wall on quantitative elastography did not differ. This is the first study that evaluate the stiffness of uterine wall in healthy ewes, providing baseline data about quantitative and qualitative stiffness of the normal uterus, and it may be a useful tool for early diagnosis of uterine alterations during the postpartum period, using the reference parameter established for the assessment of uterine integrity during postpartum period.(AU)


Assuntos
Animais , Feminino , Útero/crescimento & desenvolvimento , Ovinos/fisiologia , Ultrassonografia/métodos , Período Pós-Parto/fisiologia , Rigidez Muscular/veterinária
8.
Rev. bras. zootec ; 52: e20220041, 2023. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1441369

Resumo

The objective of this study was to evaluate characteristics of the testicular parenchyma and vascular parameters of the pampiniform plexus obtained by ultrasound, semen quality parameters, and sperm freezability in Nellore bulls classified based on residual feed intake (RFI). Twenty-seven bulls (21.82±0.88 months of age) evaluated for feed efficiency were sampled for the study, including 15 with low RFI (−0.592±0.09 kg dry matter/day) and 12 with high RFI (0.792±0.10 kg dry matter/day). In ultrasound and Doppler assessment, the most efficient animals (low RFI) showed higher pulsatility and resistive indexes, as well as a tendency towards greater heterogeneity of the testicular parenchyma (0.625±0.032 vs. 0.508±0.032, 1.012±0.072 vs. 0.802±0.072, and 12.9±0.96 vs. 10.2±0.96, respectively, for low vs. high RFI). However, these animals tended to have lower peak diastolic velocity (5.19±0.50 for low RFI vs. 6.54±0.50 for high RFI). Analysis of fresh semen showed a lower percentage of minor defects in low RFI animals (2.67±1.19%) compared with high RFI animals (8.10±1.19%), without differences in the other parameters in fresh or thawed semen and after thermoresistance testing. Evaluation of flow cytometry parameters showed a higher quality of mitochondrial respiration in semen samples of low RFI animals (22.04±2.50%) compared with high RFI animals (12.29±2.71%). Therefore, although RFI exerts an effect on the Doppler parameters of the pampiniform plexus, it is not sufficient to affect the quality of fresh or thawed semen.(AU)


Assuntos
Animais , Masculino , Testículo/fisiologia , Bovinos/fisiologia , Ingestão de Alimentos , Análise do Sêmen/veterinária
9.
Acta sci. vet. (Impr.) ; 51(supl.1): Pub. 847, 2023. ilus
Artigo em Português | VETINDEX | ID: biblio-1416633

Resumo

Background: Peritoneopericardial diaphragmatic hernia is a rare pathogenesis of congenital origin, which occurs due to a failure in the communication between the diaphragm and the pericardium during embryogenesis. Symptoms may be non-existent or non-specific, depending on the herniated organ involved and, in most cases, the diagnosis is incidental. Regarding the most indicated treatment, there are still divergences in the literature concerning the indication of conservative or surgical treatment. This study reports the case of a feline peritoneopericardial hernia, for which surgical correction was the treatment of choice. Case: A 3-month-old female kitten, no defined racial pattern, was referred to the Veterinary Hospital of the Federal Rural University of Pernambuco for treatment of a peritoneopericardial diaphragmatic hernia. This condition was diagnosed through radiographic examination after the patient having been submitted to pediatric castration and presented anesthetic complications in the transsurgery. Blood count, biochemical profile and Doppler echocardiogram were performed, which showed no significant changes. To obtain a better study and surgical planning, computed tomography was performed to observe the heart located cranially in the pericardial cavity. Caudally to the heart, hepatic parenchyma located in the pericardial cavity was observed; and hepatic vessels presenting slightly enlarged dimensions. These tomographic findings suggested peritoneopericardial diaphragmatic hernia; being the liver present in the pericardial cavity and signs of congestion in the hepatic parenchyma. Due to the likelihood of future worsening of the hernia, surgical correction was performed, with an abdominal midline incision in the preumbilical region to reposition the liver to its normal anatomy, followed by diaphragm reconstitution through a herniorrhaphy. After the surgical procedure, the patient was referred for observation in internment and, after 15 days, the skin sutures were removed. Complete correction of the hernial defect was observed on radiography performed 30 days after the surgical procedure. However, the examination showed the presence of deviation/ deformity in the topography of the sternum and costal cartilages, with slight cardiac displacement to the right hemithorax, suggesting the presence of pectus excavatum. Discussion: Peritoneopericardial diaphragmatic hernia is considered rare and, despite being one of the most common causes of congenital pericardial anomaly in felines, it has a low prevalence ranging from 0.06% to 1.45%. They are usually diagnosed from two years of age, with prevalence for older animals. However, due to having presented anesthetic changes, the patient of this case report could be diagnosed early. Among the most common organs that migrate to the thoracic cavity, the liver is the most commonly observed, which is also the hernia content of the present report. Peritoneopericardial hernia is often diagnosed through radiography and ultrasound, and these imaging tests proved to be sufficient for the diagnosis in this report. However, computed tomography was important for providing a better study of case and for the adoption of median celiotomy as a treatment. Associations with other malformations are described in the literature, with pectus excavatum being the most common and also observed in this report. Peritoneopericardial diaphragmatic hernia is a rare anomaly, rarely reported in the literature and with divergences regarding its treatment. The adoption of early surgical treatment performed in this report showed satisfactory evolution and the possibility of a favorable prognosis.


Assuntos
Animais , Feminino , Gatos , Pericárdio/anormalidades , Peritônio/cirurgia , Hérnias Diafragmáticas Congênitas/veterinária , Radiografia/veterinária
10.
Acta sci. vet. (Impr.) ; 50: Pub. 1871, 2022. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1400654

Resumo

Background: Diagnostic ultrasound has revolutionized obstetric practice. Doppler techniques provided in vivo studies of the fetus-placental and uterus-placental circulations, in an increasingly precise manner. The assessment of fetal well-being is essential in obstetric practice, however, in veterinary medicine, there is a deficit of ultrasound parameters related to fetal distress. The main of this research was to determine the hemodynamic characteristics and behavior, through Doppler ultrasonography, of maternal-fetal vessels during the final third of gestation in bitches with fetuses under stress, as well as correlating them with each other and with fetal distress. Materials, Methods & Results: An observational, prospective study was carried out, in which 30 healthy bitches were examined, during the last third of pregnancy, with fetuses under fetal distress. Fetuses were evaluated in 2 stages: (1st): 50-54 days and (2nd): 55-60 days of gestation. All fetuses were calmly assessed, one by one, and fetal heart rate (FHR) was measured 5 times, for at least 3 min, to identify and confirm fetal distress. At least 3 fetuses were evaluated in each bitch and each measurement was performed in triplicate, setting a hemodynamic mean for each value evaluated. The flow pattern in the middle cerebral artery (MCA), internal carotid artery (ICA) and umbilical artery (UA) was evaluated. The analyzed vessel was initially visualized in B mode, followed by evaluation by color and spectral Doppler. The variables observed were: peak systolic velocity (PSV), end diastolic velocity (EDV) and the resistivity (RI) and pulsatility (PI) index, as well as the systole/diastole ratio (S/D). The analysis of RI and PI of the umbilical artery showed a statistically significant difference between the mean values found for the times studied, increasing from time 1 to time 2. For middle cerebral and internal carotid arteries, PI, RI and the relationship systole/diastole (S/D), showed a statistically significant difference between the mean values found for the times studied, decreasing from time 1 to time 2. Discussion: Fetal heart rate (HR) findings are considered normal above 200 beats per minute (bpm), only if preceded by acceleration and deceleration. This fact confirms the presence of fetal stress, by this parameter, for the fetuses in the present study. Corroborating the picture of fetal distress, another study concluded that HR tends to increase up to 20 days before delivery, a fact that did not occur in the study in question, where animals in the same gestational period were evaluated. Recent research has concluded that an elevated umbilical artery PI at 28 weeks of gestation, in the absence of fetal growth restriction or prematurity, is associated with some adverse cognitive findings in 12-year-olds children. In the present study, a progressive increase in this index was observed throughout the final third of pregnancy. Although the pups were not monitored after birth, this data serves as a warning for veterinarians, and can be useful in the assessment and diagnosis of possible postnatal nervous alterations. Like what was found in the present study, a study reported that from the 4th week to birth, the PSV of the umbilical artery (UA) increased almost linearly, with high significance. For the middle cerebral arteries, the PI showed a statistically significant difference between the mean values found for the times studied, however, decreasing throughout the final third of pregnancy.


Assuntos
Animais , Feminino , Gravidez , Cães , Sofrimento Fetal/veterinária , Sofrimento Fetal/diagnóstico por imagem , Monitorização Hemodinâmica/veterinária , Troca Materno-Fetal/fisiologia , Ultrassonografia Doppler/veterinária
11.
Anim. Reprod. (Online) ; 19(3): e20220014, set. 2022. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1396857

Resumo

The objective was to evaluate the blood flow of the uterine artery (UA) and umbilical artery (UMB) in the physiological pregnancy of goats by means of Doppler throughout the gestational period. Twenty-five Saanen goats weighing 55 ± 10 kg and aged between 2 and 5 were evaluated weekly, from the 21st until the 143rd day of gestation, and daily from that period until parturition. Values for peak systolic velocity (PSV), end diastolic velocity (EDV) and resistance (RI) and pulsatility (PI) indices of the uterine and umbilical arteries were determined. The values obtained were correlated with gestational age by Spearman's test, tested for adjustment to regression models and compared with the number of fetuses by ANOVA. The umbilical cord was first visualized at 28 days. Of the variables evaluated, RIUMB and PIUMB correlated with gestational age (p<0.001; and 0.046; respectively) and RIUMB had a low negative correlation with the number of fetuses per pregnancy (p = 0.003; r- Spearman = - 0.218). PSVUMB and EDVUMB values did not correlate with gestational age (p=0.737 and 0.768, respectively), but there was a decrease in the mean values throughout pregnancy (PSVUMB= 0.07; 0.31 and EDVUMB= 0.01; 0.06) as well as the change in the flow pattern of the spectral trace. The mean values of the uterine artery dopplervelocimetric variables PSVUT, EDVUT, PIUT and RIUT did not correlate with gestational age (p= 0.324; 0.372, 0.143; 0.13; respectively). It is expected that the results obtained will contribute to a broader understanding of the hemodynamic changes resulting from pregnancy in goats.(AU)


Assuntos
Animais , Feminino , Gravidez , Artérias Umbilicais/diagnóstico por imagem , Cabras/anatomia & histologia , Ultrassonografia Doppler/veterinária , Artéria Uterina/diagnóstico por imagem , Circulação Placentária/fisiologia
12.
Acta sci. vet. (Impr.) ; 50: Pub. 1880, 2022. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1400789

Resumo

Background: Photoplethysmography is widely used in human medicine, with few studies on its use in veterinary medicine. Its sensor detects fluctuations in blood volume at the site, providing direct readings of cardiac pulse and peripheral oxygen saturation, as well as estimating cardiac output, respiratory rate and blood pressure. This study aimed to evaluate the use of photoplethysmography and compare it to vascular Doppler ultrasound as an indirect method of measuring systolic blood pressure in bitches undergoing elective ovariohysterectomy, using the invasive assessment of systolic blood pressure as a reference. Materials, Methods and Results: After clinical and laboratory evaluation, 34 healthy bitches were selected to undergo elective ovariohysterectomy. After food and water fasting, patients received pethidine hydrochloride intramuscularly as pre-anesthetic medication, followed by anesthetic induction with fentanyl citrate and propofol intravenously. General anesthesia was maintained by inhalation with isoflurane diluted in 100% oxygen. Intraoperative analgesia consisted of continuous infusion of fentanyl citrate intravenously. The animals were randomly divided into 2 groups, the thoracic limb group (TLG) and the pelvic limb group (PLG). In each patient, non-invasive blood pressure measurement was obtained simultaneously with Doppler (DOP) and photoplethysmography (PPG). The sensors of both devices were placed on the end of the same limb. The PPG sensor was positioned in the interdigital region. In patients belonging to the TLG, the Doppler sensor was placed in the ventral region of the thoracic limb, under the ulnar artery. In PLG patients, the Doppler sensor was placed in the dorsal region of the pelvic limb, over the dorsal artery of the foot. The sphygmomanometer was positioned close to the sensors. For systolic blood pressure (SBP) measurement, the cuff was inflated until the Doppler sound signal and the plethysmographic wave were lost. The cuff was then deflated until the Doppler pulse sound resumed and the photoplethysmography showed at least 2 continuous waves on a regular basis. The corresponding pressure value observed on the manometer consisted of the SBP. The same 2 evaluators performed all SBP measurements: 1 responsible for the DOP method and the other for the PPG method; both were blind to the other's findings, thus minimizing potential bias in the results. All animals underwent cannulation of the auricular artery for invasive measurement of systolic blood pressure, using a multiparameter monitor. All blood pressure measurements were performed at 5-min intervals, as well as obtaining additional parameters (heart and respiratory rate, esophageal temperature, partial tissue oxygen saturation, carbon dioxide concentration) and electrocardiographic monitoring. All parameters were documented for further statistical analysis. A strong correlation (r² = 0.95) was obtained between the DOP and PPG methods regardless of the limb on which the sensors were placed. There was a low correlation between the invasive method of measuring systolic blood pressure and the other methods. There was better agreement between the DOP and PPG methods (r2 = -0.0061; P = 0.85) when systolic blood pressure was measured in the TLG. Discussion: In the PLG, the values obtained with the DOP and PPG methods were significantly higher than those obtained with the invasive method, while the values obtained in the TLG differed slightly. It was found that the best measurement site by non-invasive methods was the thoracic limb. It was concluded that the non-invasive methods showed a low correlation with the invasive method; however, both methods had similar characteristics and photoplethysmography can be used to replace the vascular Doppler method.


Assuntos
Animais , Feminino , Cães , Determinação da Pressão Arterial/veterinária , Ecocardiografia Doppler/métodos , Fotopletismografia/veterinária , Ovariectomia/veterinária , Histerectomia/veterinária , Anestesia Geral/veterinária
13.
Acta sci. vet. (Online) ; 50: Pub. 1849, Jan. 13, 2022. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-31327

Resumo

Background: Doppler ultrasonography enables the investigation of vascular blood flow indexes in gestational assessment,being able to detect vascular resistances that can affect fetal and maternal circulation, such as cases of placental insufficiency, associated with fetal cerebral oxygenation deficit and fetal distress. The study aims to assume hemodynamicallynormal values in the final third of gestation in bitches, of the umbilical, uteroplacental, middle cerebral and internal carotidarteries, correlating the obtained Doppler velocimetric indexes, for the assessment of the feto-placental circulation, andprediction of fetal viability indexes, fetal centralization and probable date of delivery.Materials, Methods & Results: Thirty healthy bitches were examined in the final third of gestation (40-60 days). Thesewere evaluated by Doppler ultrasonography at 2 times (T): T1: between 40-50 days; T2: between 51-60 of gestation.At each time point, the peak systolic velocities (PSV) and end-diastolic velocities (EDV) used to obtain the pulsatility(IP) and resistivity (IR) indexes of the umbilical, uteroplacental, middle cerebral and internal carotid arteries of fetuseswere evaluated. Also, the systole/diastole (S/D) ratio of these vessels was evaluated. The data obtained were subjected toanalysis of variance and Tukey test, using a P value equal to 5%. A significant difference was observed between velocitiesand Doppler velocimetric indexes between the 2 phases of the gestational final third in all studied vessels. There was anincrease in the values of PSV and EDV and a decrease in the indexes, as the probable date of delivery approached. Theanalysis of the umbilical cord IR showed an increase from P1 to P2 (P < 0.05), while the IP decreased at the same time.For all studied variables there was a statistically significant difference (P < 0.05). In the uteroplacental...(AU)


Assuntos
Animais , Feminino , Gravidez , Cães , Monitorização Hemodinâmica/métodos , Monitorização Hemodinâmica/veterinária , Circulação Placentária , Artérias Umbilicais/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Artérias Cerebrais/embriologia , Ultrassonografia Doppler/veterinária
14.
Acta sci. vet. (Impr.) ; 50: Pub.1849-2022. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1458524

Resumo

Background: Doppler ultrasonography enables the investigation of vascular blood flow indexes in gestational assessment,being able to detect vascular resistances that can affect fetal and maternal circulation, such as cases of placental insufficiency, associated with fetal cerebral oxygenation deficit and fetal distress. The study aims to assume hemodynamicallynormal values in the final third of gestation in bitches, of the umbilical, uteroplacental, middle cerebral and internal carotidarteries, correlating the obtained Doppler velocimetric indexes, for the assessment of the feto-placental circulation, andprediction of fetal viability indexes, fetal centralization and probable date of delivery.Materials, Methods & Results: Thirty healthy bitches were examined in the final third of gestation (40-60 days). Thesewere evaluated by Doppler ultrasonography at 2 times (T): T1: between 40-50 days; T2: between 51-60 of gestation.At each time point, the peak systolic velocities (PSV) and end-diastolic velocities (EDV) used to obtain the pulsatility(IP) and resistivity (IR) indexes of the umbilical, uteroplacental, middle cerebral and internal carotid arteries of fetuseswere evaluated. Also, the systole/diastole (S/D) ratio of these vessels was evaluated. The data obtained were subjected toanalysis of variance and Tukey test, using a P value equal to 5%. A significant difference was observed between velocitiesand Doppler velocimetric indexes between the 2 phases of the gestational final third in all studied vessels. There was anincrease in the values of PSV and EDV and a decrease in the indexes, as the probable date of delivery approached. Theanalysis of the umbilical cord IR showed an increase from P1 to P2 (P < 0.05), while the IP decreased at the same time.For all studied variables there was a statistically significant difference (P < 0.05). In the uteroplacental...


Assuntos
Feminino , Animais , Gravidez , Cães , Artéria Carótida Interna/diagnóstico por imagem , Artérias Cerebrais/embriologia , Artérias Umbilicais/diagnóstico por imagem , Circulação Placentária , Monitorização Hemodinâmica/métodos , Monitorização Hemodinâmica/veterinária , Ultrassonografia Doppler/veterinária
15.
Rev. bras. reprod. anim ; 46(1): 17-27, Janeiro-Março 2022. tab
Artigo em Português | VETINDEX | ID: biblio-1378025

Resumo

O objetivo desta revisão foi descrever as principais técnicas de avaliação e achados ultrassonográficos da próstata canina. A ultrassonografia é o método de escolha para avaliação da glândula prostática, sendo imprescindível como auxílio no diagnóstico na detecção de anormalidades, principalmente quando há suspeita da presença de tumores. Com inovação dos equipamentos, surgiram técnicas complementares à ultrassonografia modo Bidimensional (B), tais como Doppler, ultrassonografia contrastada e elastografia, que aumentam a acurácia diagnóstica. O Doppler fornece informações sobre arquitetura vascular e aspectos hemodinâmicos dos vasos sanguíneos. A ultrassonografia contrastada permite determinar parâmetros relacionados à perfusão sanguínea das estruturas pelos agentes de contraste (ex.: microbolhas), definindo, portanto, padrões de alta e baixa intensidade da arquitetura vascular. A elastografia proporciona a avaliação da rigidez tecidual tanto de forma qualitativa, por meio de elastogramas, quanto quantitativa, por meio das velocidades de cisalhamento. Espera-se que esta revisão possa contribuir com informações relevantes aos leitores e veterinários da área de ultrassonografia e reprodução animal.(AU)


The purpose of this review was to describe the main assessment techniques and ultrasound findings of the canine prostate. Ultrasonography is the method of choice for assessing the prostate gland, being essential as an aid in the diagnosis in the detection of abnormalities, especially when the presence of tumors is suspected. With the innovation of the equipment, complementary techniques to B-mode ultrasonography have emerged, such as Doppler, contrasted ultrasound and elastography, which increase the diagnostic accuracy. Doppler provides information on vascular architecture and hemodynamic aspects of blood vessels. Contrast ultrasonography allows to determine parameters related to the blood perfusion of structures by contrast agents (eg, microbubbles), thus defining high and low intensity patterns of vascular architecture. ARFI elastography provides assessment of tissue stiffness both qualitatively, using elastograms, and quantitative, using shear speeds. It is hoped that this review can contribute with relevant information to readers and veterinarians in the area of asound and animal reproduction.(AU)


Assuntos
Animais , Cães , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Doppler/métodos , Equipamentos para Diagnóstico/veterinária , Técnicas de Imagem por Elasticidade/métodos , Vasos Sanguíneos/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Microbolhas/veterinária , Imagem de Perfusão/veterinária , Rigidez Vascular/fisiologia
16.
Arq. bras. med. vet. zootec. (Online) ; 74(3): 412-418, May-June 2022. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1383769

Resumo

This retrospective case series study describes the clinical and vascular ultrasound findings of 26 dogs diagnosed with abdominal thrombosis. Images were selected based on the detection of intravascular echogenic thrombus or the absence of vascular flow on color Doppler, confirmed by surgery or necropsy. Images were acquired using the Mylab 40 model, with linear and microconvex multifrequency probes. All the reports were evaluated along with the corresponding images by a veterinary diagnostic imaging radiologist. The ultrasonographic aspects evaluated were echogenicity (92.3%), anechogenicity (7.7%), vascularization (11.5%), mineralization (15.4%), and recanalization (7.7%) of the thrombosis. The vascular and hemodynamic findings were dilation of the affected vein (57.7%), total occlusion of blood flow (30.8%), presence of turbulent flow (65.38%), and visualization of smoke signal (blood flow detected as moving echogenic points in dynamic bidimensional mode) (11.5%). Neoplasms (19 cases) and nephropathies (13 cases) were the most common clinical conditions in the affected dogs. Eleven cases of vascular invasion due to adrenal neoplasms were identified. The results indicate that the vascular ultrasound examination is an important method for diagnosis, as 23 of the 26 cases did not show any clinical signs of thrombosis.


Este estudo de série de casos retrospectivos descreve os achados clínicos e ultrassonográficos vasculares de 26 cães diagnosticados com trombose. As imagens foram selecionadas baseadas na detecção de trombo ecogênico intravascular ou na ausência de fluxo vascular ao Doppler colorido, confirmado por cirurgia ou necropsia. O equipamento utilizado na aquisição das imagens foi o modelo Mylab 40, com probes multifrequenciais linear e microconvexa. Todos os relatórios foram avaliados com as imagens correspondentes por um veterinário radiologista. As características ultrassonográficas avaliadas foram: ecogenicidade (92,3%), anecogenicidade (7,7%), vascularização (11,5%), mineralização (15,4%) e recanalização (7,7%) das tromboses. Os achados vasculares e hemodinâmicos observados foram: dilatação da veia afetada (57,7%), oclusão total do fluxo sanguíneo (30,8%), presença de fluxo turbulento (65,38%) e visibilização do sinal de fumaça (fluxo vascular visível como pontos ecogênicos em modo bidimensional dinâmico) (11,5%). As neoplasias (19 casos) e as nefropatias (13 casos) foram as condições clínicas mais comuns nos cães afetados. Foram identificados 11 casos de invasão vascular decorrentes de neoplasia de adrenais. Os resultados indicaram que o exame ultrassonográfico vascular é um método importante para diagnóstico, considerando-se que, em 23 casos, não ocorreram sinais clínicos determinantes de trombose.


Assuntos
Animais , Cães , Trombose , Doenças do Cão/diagnóstico por imagem , Nefropatias , Neoplasias
17.
Semina ciênc. agrar ; 43(6): 2643-2656, nov.-dez. 2022. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1425817

Resumo

For this study, ½ blood Nelore × Aberdeen Angus heifers (n = 40; 14 months) were divided into two groups: control (n=20; 310 kg) and Pró-Cio (n=20; 304 kg). For Pró-Cio group, 20g of homeopathic product (Pró-cio®, Real H, Campo Grande, Brazil) was supplied together with corn eighteen days prior (D-18) to the beginning of the fixed-time artificial insemination protocol (FTAI). On D0, all females received an intravaginal P4 device and 2 mg BE. On D5, the AFC was assessed by ultrasound and blood was collected for AMH dosage. On D8, P4 device was removed; 300 IU eCG, 0.530 mg of cloprostenol sodium and 0.5 mg of EC were administered; an estrus-identifying adhesive was fixed at the tail insertion and the diameter of the dominant follicle (DF) was measured. On D10, all heifers were inseminated, estrus manifestation was assessed and the preovulatory follicle (POF) was measured. On D20, the CL area was measured and blood flow was assessed using Doppler ultrasound. Data were analyzed by Student, Mann-Whitney or Friedman test. The rates of heat expression, ovulation, and blood flow score with Doppler were analyzed using Fisher's exact test and pregnancy rate by binary logistic regression model (P ≤ 0.05). There was no difference in AFC or AMH dosage (P > 0.05). Pró-Cio group had greater diameters of the DF (9.94 ± 0.42 mm) and POF (11.61 ± 0.56 mm) than the controls (DF: 7.72 ± 0.34 mm and POF: 9.91 ± 0.37 mm), as well a larger CL area (3.26 ± 0.26 versus 2.35 ± 0.16 cm2) and a higher mean CL vascularization score (3.06 versus 2.26; P < 0.05). There was no significant difference (P > 0.05) between estrus manifestation or conception rate for control and Pró-Cio groups. Heifers supplemented with the homeopathic product showed larger follicular diameters at the end of the FTAI protocol and CL with better blood flow scores compared to the control group.


Para esse estudo, novilhas ½ sangue Nelore x Aberdeen Angus (n = 40; 14 meses) foram divididas em dois grupos: Controle (n = 20; 310 kg) e Pró-cio (n = 20; 304 kg). Para o grupo Pró-Cio, 20 g/animal de produto homeopático (Pró-cio®, Real H, Campo Grande, Brazil) foi fornecido juntamente com o milho dezoito dias antes (D-18) de inicar o protocolo de inseminaçãoa artificial em tempo-fixo (IATF). No D0, todas as fêmeas receberam um dispositivo intravaginal de P4 e 2 mg BE. No D5, avaliou-se a contagem de folículos antrais (CFA) por ultrassonografia e realizou-se coleta de sangue para dosagem de AMH. No D8, procedeu-se a retirada do dispositivo de P4; aplicação de 300 UI de eCG, 0,530 mg de cloprostenol sódico e 0,5 mg de CE; um adesivo identificador de estro foi fixado na inserção da cauda e foi feita a mensuração do diâmetro do folículo dominante (FD). No D10, todas as novilhas foram inseminadas, foi realizada a avaliação da manifestação de estro e mensuração do folículo pré-ovulatório (FPO). No D20, realizou-se mensuração da área e avaliação do fluxo sanguíneo do CL por ultrassonografia Doppler. Os dados foram analisados pelos testes de Student, Mann-Whitney ou Friedman. As taxas de expressão de estro, ovulação e escore de fluxo sanguíneo com Doppler foram analisadas usando o teste exato de Fisher e taxa de prenhez pelo modelo de regressão logística binária (p ≤ 0,05). Não houve diferença na CFA nem na dosagem de AMH (p > 0,05). O grupo PróCio apresentou maior diâmetro do FD (9,94 ± 0,42 mm) e FPO (11,61 ± 0,56 mm) em relação ao controle (FD: 7,72 ± 0,34 mm e FPO: 9,91 ± 0,37 mm), além de maior área do CL (3,26 ± 0,26 versus 2,35 ± 0,16 cm2; p < 0,05) e maior escore de vascularização médio do CL (3,06 versus 2,26; p < 0,05). Não houve diferença (p > 0,05) na taxa de manifestação de estro e nem na taxa de concepção entre os grupos Controle e Pró-Cio, respectivamente. Novilhas suplementadas com o produto homeopático apresentaram maiores diâmetros foliculares ao final do protocolo de IATF e CL com melhores escores de fluxo sanguíneo em relação ao grupo controle.


Assuntos
Animais , Bovinos , Reprodução , Inseminação Artificial/veterinária , Corpo Lúteo , Homeopatia/veterinária
18.
Acta sci. vet. (Impr.) ; 50(suppl.1): Pub.763-4 jan. 2022. ilus
Artigo em Português | VETINDEX | ID: biblio-1458571

Resumo

Background: The myxomatosis degeneration is a degenerative cardiac valve disease, with a higher incidence in maleand senile canids. The diagnosis is made by a doppler echocardiography exam. Although there are few reports on the occurrence of cardiopathies in wild dogs (Cerdocyon thous), some studies on their cardiological parameters can be found.Considering this, and knowing that the cardiopathies in wild canids are common post mortem findings, the objective of thisstudy is to describe the echocardiography diagnosis of a case of myxomatous degeneration of the atrioventricular valvesin 1 wild dog (Cerdocyon thous) living in captivity.Case: It was treated at the Diagnostic Imaging Department of the Veterinary Hospital of the Federal University of Mato Grosso(HOVET-UFMT), 1 wild dog (C. thous), male, living in captivity with approximately 10-year-old, directed by the Center ofMedicine and Research in Wild Animals of Cuiabá, to perform echocardiography exam. The patient was submitted to anesthesiafor proper examination, which was used Esaote® machine model MyLabFive VET with sector scan transducer (4.0 -7.5 MHz).The longitudinal, transverse and apical scan planes were obtained through left and right parasternal windows. The evaluation ofM mode exposed ejection fraction and shortening increased, of 81% and 47%, respectively, however it showed no increase insystolic and diastolic values of left ventricle, nor in right cavities on subjective evaluation. The relation between the left atrium(LA) and the aorta (Ao) remained normal, at 1.2 mm, with dimensions of 13.4 mm from the AO and 16.3 mm from LA, compatible with species parameters or domestic canines. The atrioventricular valves showed thickening and irregularities in their cusps,with great intensity in the left atrioventricular valve (LAV). The Doppler mode analysis revealed a turbulent systolic flow into the...


Assuntos
Masculino , Animais , Canidae , Cardiopatias/diagnóstico por imagem , Cardiopatias/veterinária , Doença Crônica/veterinária , Valvas Cardíacas/patologia , Animais Selvagens , Ecocardiografia/veterinária
19.
Rev. bras. reprod. anim ; 45(4): 574-582, out.-dez. 2021. ilus
Artigo em Português | VETINDEX | ID: biblio-1492711

Resumo

A ultrassonografia do sistema reprodutivo é uma importante ferramenta utilizada em associação ao exame andrológico para avaliação de machos reprodutores. Novas modalidades de análise ultrassonográfica foram descritas na última década, como a análise Doppler da artéria testicular. O objetivo deste texto é apresentar estas modalidades com o intuito de acrescentar informações importantes ao exame andrológico de cães e gatos.


The ultrasound of the reproductive system is an important tool used in association with the andrological examination to evaluate reproductive males. New modalities of ultrasound analysis have been described in the last decade, such as the Doppler analysis of the testicular artery. The objective of this text is to present these tools in order to add important information to the andrological examination of dogs and cats.


Assuntos
Animais , Gatos , Cães , Andrologia , Cães , Gatos , Ultrassonografia Doppler
20.
Rev. bras. reprod. anim ; 45(4): 459-469, out.-dez. 2021. ilus
Artigo em Português | VETINDEX | ID: biblio-1492695

Resumo

The use of different ultrasound modalities (color, power and pulsed Doppler) in clinical research has enhanced knowledge of reproductive pathophysiology in equine, in addition to improving the clinical diagnosis of reproductive disorders in both the stallion and the mare. In the stallion, color Doppler ultrasound has improved the diagnostic potential of conventional ultrasound, improving the differential diagnosis of pathologies such as testicular torsion (decrease or absence of blood flow in the cord) and orchitis (increased blood flow in the cord). The function of the testicle is highly dependent on the blood flow it receives; therefore, any vascular alterations can affect both the quality and production of sperm. In recent years there have been a greater number of studies in which Doppler ultrasound is used as a tool in the diagnosis of testicular dysfunction and in the monitoring of medical and surgical treatments. In the mare, ultrasound technology has allowed numerous advances in basic research regarding the vascular hemodynamics of the ovary and uterus. Moreover, it has become an indispensable tool in reproductive practice. Among the clinical applications of this technique in mares are the evaluation of CL (corpus luteum) functionality, being a useful tool in the selection of recipients in embryo transfer programs or the use of power Doppler in the diagnosis of pregnancy as early as 7 days postovulation prior to flushing. Finally, the incorporation of color and pulsed Doppler ultrasound into the examination improves the diagnosis of mares with endometritis due to a pathological increase in uterine blood flow.


Assuntos
Animais , Cavalos , Fertilidade , Ultrassonografia Doppler
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA