Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
Acta sci. vet. (Impr.) ; 51: Pub. 1917, 2023. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1443930

Resumo

Background: Hypertrophic phenotype cardiomyopathy is the most common heart disease in cats. Although the echocardiogram is the gold standard test for diagnosing fHCM, patients with the disease may have electrocardiographic changes. Despite being reported in most 12-lead electrocardiograms, the P wave axis generally receives little attention when compared to other wave parameters. We performed a Doppler echocardiographic and electrocardiographic study in cats, in order to verify the presence of correlation between the electrical axis average P wave and the presence of fCMH, aiming to investigate the possibility of its aid in the early diagnosis of cardiac disorders. Materials, Methods & Results: One hundred cats of different breeds, ages, males and females were evaluated. Those animals with a history of previous disease other than hypertrophic cardiomyopathy were excluded from the study. The groups were formed after obtaining the results of the echocardiographic examination. Eight of the 100 cats did not allow echocardiographic evaluation, and the remaining 92 were divided into 2 groups (control group, n = 64 and heart disease group, n = 28) after the examination. Of these 92 animals, 28 cats had the hypertrophic cardiomyopathy phenotype. The electrocardiographic examination was performed after the allocation of animals into groups lasting 5 min with the recording of tracings for later interpretation. To calculate the axis of the P wave, leads D1 and D3 were used, measuring the amplitude of the P wave in these leads and calculating the resulting amplitude. All cats studied had mean electrical axis of the P wave within the normal range for the species (0º to 90º). Based on mean electrical axis P wave values, there was no significant difference between groups. The control group had a median of 63.7° with a maximum value of 80°, a minimum value of 60° and a mean of 65.1°. The fCMH group had a median of 68.7° with a maximum value of 85.3°, a minimum value of 56.3° and a mean of 68.8°. Of the fCMH group, 3 cats had increased P wave duration (50.33 ± 5.77 ms), suggesting left atrial overload, and 13 cats had increased QRS complex duration (66.30 ± 11.23 ms). Also, 18 cats (Control group: 11; fCMH group: 7) showed T wave amplitude greater than 25% of R, suggesting the presence of myocardial hypoxia and/or electrolyte disturbance. One cat had a prolonged PR interval (from the fCMH group). As for the QT interval, 6 cats had an interval < 120 (2 from the control group and 4 from the affected group) and 3 had an interval > 180 (1 from the control group and 2 from the affected group). The ST segment remained isoelectric in all segments. As for the mean electrical axis of the QRS complex, 5 cats (10.42%) had axis deviation to the right (control: 1; fCMH: 4) suggesting right ventricular overload; 7 cats (14.58%) had left axis deviation (control: 5; fCMH: 2), suggestive of left ventricular overload; and 36 cats (75%) had a normal mean electrical axis. Discussion: Based on the results obtained in the present study, it can be concluded that screening studies in asymptomatic felines should be increasingly implemented in the veterinary clinical routine, since the frequency found was high (30.44%) and that patients may remain asymptomatic for years until the development of signs. It should be concluded that there was no correlation between the mean electric axis of P-wave and the presence of subclinical phenotype hypertrophic cardiomyopathy. Therefore, more studies are needed, with felines at different stages of the disease, to evaluate whether this electrocardiographic measurement allows us to assist in its diagnosis, since it is a feasible measure in cats. Furthermore, it is concluded that the electrocardiogram should be used as an aid method in the diagnosis of the disease and not as a screening test.


Assuntos
Animais , Masculino , Feminino , Gatos , Cardiomiopatia Hipertrófica/veterinária , Análise de Onda de Pulso/veterinária , Ecocardiografia Doppler de Pulso/veterinária
2.
Arq. bras. med. vet. zootec. (Online) ; 74(4): 745-748, July-Aug. 2022. tab
Artigo em Inglês | VETINDEX | ID: biblio-1393900

Resumo

O eletrocardiograma (ECG) é um importante método diagnóstico, essencial para determinar o ritmo e o funcionamento elétrico do coração. Os gambás (D. albiventris) frequentemente são atendidos nos Centros de Triagem de Animais Silvestres (CETAS), contudo pouco se sabe sobre o sistema cardiovascular dessa espécie. Dessa forma, o objetivo foi estabelecer valores de referência dos parâmetros eletrocardiográficos dessa espécie. Foram utilizados 32 filhotes, considerados hígidos nos exames clínicos geral e específico. Avaliaram-se a frequência cardíaca, o ritmo, a morfologia, a amplitude e a duração das ondas P, o complexo QRS e T, a duração dos intervalos PR e QT e o segmento ST. A frequência cardíaca média foi de 214 batimentos por minuto (bpm), o ritmo sinusal mostrou-se normal e houve arritmia sinusal em 25% dos pacientes. O eixo médio foi de 40º(QRS)e 47º (P). A onda P apresentou morfologia positiva (81,3%) e negativa (18,7%), amplitude de 0,03mV (±0,01) e duração de 0,04s (±0,04). O complexo QRS apresentou morfologia QRS ou RS (31%) e duração de 0,05s (±0,06). A amplitude de Q foi de -0,04mV (±0,05), a de R foi 0,23mV (±0,16) e S -0,07mV (±0,08). Já a onda T apresentou morfologia variada, amplitude de 0,04mV (±0,04) e duração de 0,04s (±0,09). O intervalo PR obteve duração de 0,05s (±0,08), QT com intervalo entre 0,08 e 0,21 e o segmento ST médio de 0,05s (±0,02). Dessa forma, observou-se que foi possível realizar o ECG em gambás filhotes e que o sexo e o peso não influenciaram no traçado obtido. Os resultados diferiram de cães, gatos e de outras espécies de gambás.


Assuntos
Animais , Gambás/fisiologia , Sistema Cardiovascular , Didelphis/fisiologia , Eletrocardiografia
3.
Arq. bras. med. vet. zootec. (Online) ; 73(1): 62-72, Jan.-Feb. 2021. tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-1153037

Resumo

Objetivou-se com este estudo comparar a associação de detomidina e cetamina ou dextrocetamina, por via intravenosa contínua, em oito cadelas submetidas a dois protocolos: GCD - indução anestésica com 5mg/kg e infusão intravenosa contínua de 20mg/kg/h de cetamina; e GDD - indução com 3,5mg/kg e infusão de 14mg/kg/h de dextrocetamina. Associou-se detomidina, 30µg/kg/h, em ambos os grupos. Registraram-se frequência cardíaca (FC), pressão arterial (PA), frequência respiratória (f), temperatura (TC), miorrelaxamento, analgesia, hemogasometria e eletrocardiograma, antes e 15 minutos após a MPA (Mbasal e Mmpa); após o início da infusão (Mic); a cada 10 minutos até 90 minutos (M10, M20, M30, M40, M50, M60, M70, M80 e M90); e 30 minutos após o fim da infusão (M120). Foi observada bradicardia em Mmpa no GCD e de Mmpa a M10 no GDD. Ocorreu hipotensão em Mmpa e hipertensão a partir de Mic. A f diminuiu de M10 a M30. Foram observados: onda T de alta amplitude, bloqueios atrioventriculares e parada sinusal. Ocorreu acidose respiratória. O período de recuperação foi de 219,6±72,3 minutos no GCD e de 234,1±96,8 minutos no GDD. A cetamina e a dextrocetamina, associadas à detomidina por infusão contínua, causam efeitos cardiorrespiratórios e anestésicos similares.(AU)


The combination of detomidine and ketamine or dextrocetamine for continuous intravenous infusion was compared in eight female dogs submitted to two protocols: GCD - 5mg/kg of anesthetic induction and continuous intravenous infusion of ketamine 20mg/kg/h; and GDD - induction with 3.5mg/kg and infusion of 14mg/kg/h of dextrocetamine. Detomidine, 30µg/kg/h was associated in both groups. Heart rate (HR), blood pressure (BP), respiratory rate (RR), temperature (CT), myorelaxation, analgesia, blood gas analysis and electrocardiogram were recorded before and 15 minutes after MPA (Mbasal and Mmpa); after the start of infusion (Mic); every 10 minutes to 90 minutes (M10, M20, M30, M40, M50, M60, M70, M80 and M90); and 30 minutes after the end of infusion (M120). Bradycardia was observed in Mmpa in GCD and from Mmpa to M10 in GDD. There was hypotension in Mmpa and hypertension from Mic. The RR decreased from M10 to M30. High amplitude T wave, atrioventricular blocks and sinus arrest were observed. Respiratory acidosis occurred. The recovery period was 219.6±72.3 minutes in GCD and 234.1±96.8 minutes in GDD. Ketamine and S+ ketamine associated with detomidine for continuous infusion cause cardiorespiratory and similar anesthetic effects.(AU)


Assuntos
Animais , Feminino , Cães , N-Metilaspartato/agonistas , Agonistas alfa-Adrenérgicos/análise , Anestésicos Combinados/análise , Ketamina/uso terapêutico , Acidose Respiratória/veterinária , Taxa Respiratória , Frequência Cardíaca , Anestesia Intravenosa/veterinária
4.
Pesqui. vet. bras ; 40(8): 630-636, Aug. 2020. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1135669

Resumo

ABSTRACT: Electrocardiographic markers have been used in people to classify arrhythmogenic risk. The aims of this study were to investigate electrocardiographic markers of conduction and repolarization in Boxers and non-Boxer dogs, and compare such findings between groups. Ten-lead standard electrocardiograms of Boxer dogs and non-Boxers recorded from 2015 to 2018 were retrospectively reviewed. Dogs >/ 4 years of age and weighing > 20kg were included. Animals with valvular insufficiencies, congenital cardiopathies, cardiac dilation, suspected systolic dysfunction, biphasic T-wave, bundle branch blocks, and those receiving antiarrhythmics were excluded. Electrocardiographic markers of conduction, QRS duration (QRSd) and dispersion (QRSD), and repolarization (corrected QT interval, Tpeak-Tend, JT and JTpeak), as well as derived indices, were measured. Two hundred dogs met the inclusion/exclusion requirements, including 97 Boxers (8.1±2.5 years old; 30±7kg) and 103 non-Boxer (8.8±2.5 years old, 30±8kg). QRSd and QRSD, and repolarization markers in lead II and left precordial lead V4 were considered similar between groups. Dispersion of late repolarization on lead rV2, Tpeak-Tend interval, was considered longer in Boxers (45±8ms vs 38±10ms, P=0.01). The Tpeak-Tend/JTpeak and the JTpeak/JT also differed between groups. Our results indicate that the dispersion of myocardial late repolarization in lead rV2 is slower in Boxers than other dog breeds.(AU)


Marcadores eletrocardiográficos têm sido estudados em seres humanos para estratificação do risco arritmogênico. Os objetivos deste estudo foram investigar os marcadores eletrocardiográficos de condução e repolarização miocárdica em Boxers e em cães de outras raças, e comparar tais resultados entre os grupos. Para tal, a eletrocardiografia convencional de 10 derivações registradas de 2015 a 2018 foram avaliadas de maneira retrospectiva. Cães com idade igual ou superior a 4 anos e pesando > 20kg foram incluídos. Animais com insuficiência valvar, cardiopatias congênitas, dilatação cardíaca, suspeita de disfunção sistólica, onda T bifásica, bloqueio(s) de ramo(s), ou aqueles que recebiam antiarrítmicos foram excluídos. Variáveis eletrocardiográficas de condução, como a duração e dispersão do complexo QRS (QRSd e QRSD, respectivamente), e repolarização (intervalo QT corrigido, Tpico-Tfinal, JT e JTpico), bem como índices derivados, foram mensurados. Duzentos cães que se adequaram aos critérios de inclusão/exclusão foram incluídos, 97 Boxers (8,1±2,5 anos; 30±7kg) e 103 não Boxers (8,8±2,5 anos; 30±8kg). O QRSd e o QRSD, e os marcadores de repolarização nas derivações II e V4 foram similares entre os grupos. O marcador de dispersão da repolarização tardia na derivação rV2, Tpico-Tfinal, foi considerado mais longo no Boxers (45±8ms vs 38±10ms, P=0.01). O Tpico-Tfinal/JTpico e o JTpico/JT também diferiram entre os grupos. Nossos resultados indicam que a dispersão da repolarização miocárdica tardia na derivação precordial direita, rV2, é mais lenta no Boxer do que nas outras raças.(AU)


Assuntos
Animais , Cães , Arritmias Cardíacas/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Eletrocardiografia/métodos , Eletrocardiografia/veterinária , Complexos Cardíacos Prematuros/veterinária , Ecocardiografia/veterinária , Sistema de Condução Cardíaco
5.
Pesqui. vet. bras ; 40(8): 630-636, Aug. 2020. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-31722

Resumo

Electrocardiographic markers have been used in people to classify arrhythmogenic risk. The aims of this study were to investigate electrocardiographic markers of conduction and repolarization in Boxers and non-Boxer dogs, and compare such findings between groups. Ten-lead standard electrocardiograms of Boxer dogs and non-Boxers recorded from 2015 to 2018 were retrospectively reviewed. Dogs >/ 4 years of age and weighing > 20kg were included. Animals with valvular insufficiencies, congenital cardiopathies, cardiac dilation, suspected systolic dysfunction, biphasic T-wave, bundle branch blocks, and those receiving antiarrhythmics were excluded. Electrocardiographic markers of conduction, QRS duration (QRSd) and dispersion (QRSD), and repolarization (corrected QT interval, Tpeak-Tend, JT and JTpeak), as well as derived indices, were measured. Two hundred dogs met the inclusion/exclusion requirements, including 97 Boxers (8.1±2.5 years old; 30±7kg) and 103 non-Boxer (8.8±2.5 years old, 30±8kg). QRSd and QRSD, and repolarization markers in lead II and left precordial lead V4 were considered similar between groups. Dispersion of late repolarization on lead rV2, Tpeak-Tend interval, was considered longer in Boxers (45±8ms vs 38±10ms, P=0.01). The Tpeak-Tend/JTpeak and the JTpeak/JT also differed between groups. Our results indicate that the dispersion of myocardial late repolarization in lead rV2 is slower in Boxers than other dog breeds.(AU)


Marcadores eletrocardiográficos têm sido estudados em seres humanos para estratificação do risco arritmogênico. Os objetivos deste estudo foram investigar os marcadores eletrocardiográficos de condução e repolarização miocárdica em Boxers e em cães de outras raças, e comparar tais resultados entre os grupos. Para tal, a eletrocardiografia convencional de 10 derivações registradas de 2015 a 2018 foram avaliadas de maneira retrospectiva. Cães com idade igual ou superior a 4 anos e pesando > 20kg foram incluídos. Animais com insuficiência valvar, cardiopatias congênitas, dilatação cardíaca, suspeita de disfunção sistólica, onda T bifásica, bloqueio(s) de ramo(s), ou aqueles que recebiam antiarrítmicos foram excluídos. Variáveis eletrocardiográficas de condução, como a duração e dispersão do complexo QRS (QRSd e QRSD, respectivamente), e repolarização (intervalo QT corrigido, Tpico-Tfinal, JT e JTpico), bem como índices derivados, foram mensurados. Duzentos cães que se adequaram aos critérios de inclusão/exclusão foram incluídos, 97 Boxers (8,1±2,5 anos; 30±7kg) e 103 não Boxers (8,8±2,5 anos; 30±8kg). O QRSd e o QRSD, e os marcadores de repolarização nas derivações II e V4 foram similares entre os grupos. O marcador de dispersão da repolarização tardia na derivação rV2, Tpico-Tfinal, foi considerado mais longo no Boxers (45±8ms vs 38±10ms, P=0.01). O Tpico-Tfinal/JTpico e o JTpico/JT também diferiram entre os grupos. Nossos resultados indicam que a dispersão da repolarização miocárdica tardia na derivação precordial direita, rV2, é mais lenta no Boxer do que nas outras raças.(AU)


Assuntos
Animais , Cães , Arritmias Cardíacas/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Eletrocardiografia/métodos , Eletrocardiografia/veterinária , Complexos Cardíacos Prematuros/veterinária , Ecocardiografia/veterinária , Sistema de Condução Cardíaco
6.
Pesqui. vet. bras ; 39(2): 142-147, Feb. 2019. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-990244

Resumo

In feline veterinary practice sedation is often needed to perform diagnostic or minimally invasive procedures, minimize stress, and facilitate handling. The mortality rate of cats undergoing sedation is significantly higher than dogs, so it is fundamental that the sedatives provide good cardiovascular stability. Dexmedetomidine (DEX) is an α2-adrenergic receptor agonist utilized in cats to provide sedation and analgesia, although studies have been utilized high doses, and markedly hemodynamic impairments were reported. The aim of this study was to prospectively investigate how the sedative and electrocardiographic effects of a low dose of DEX performing in cats. Eleven healthy cats were recruited; baseline sedative score, systolic arterial pressure, electrocardiography, and vasovagal tonus index (VVTI) were assessed, and repeated after ten minutes of DEX 5μg/kg intramuscularly (IM). A smooth sedation was noticed, and emesis and sialorrhea were common adverse effects, observed on average seven minutes after IM injection. Furthermore, electrocardiographic effects of a low dose of DEX mainly include decreases on heart rate, and increases on T-wave amplitude. The augmentation on VVTI and appearance of respiratory sinus arrhythmia, as well as sinus bradycardia in some cats, suggesting that DEX enhances parasympathetic tonus in healthy cats, and therefore will be best avoid in patients at risk for bradycardia.(AU)


Na rotina clínica da medicina veterinária felina a sedação é frequentemente requerida para realização de procedimentos diagnósticos ou minimamente invasivos, para minimizar o estresse e facilitar o manuseio dos pacientes. A taxa de mortalidade de gatos submetidos à sedação é mais elevada do que em cães, por esse motivo, é fundamental que os sedativos confiram estabilidade hemodinâmica. A dexmedetomidina (DEX) é um α2-agonista utilizado em felinos para promover sedação e analgesia, porém os estudos têm utilizado doses elevadas, e com isso prejuízos hemodinâmicos importantes foram relatados. O objetivo desta investigação foi avaliar os efeitos sedativos e eletrocardiográficos da baixa dose de DEX em gatos. Para tal, onze felinos saudáveis foram recrutados, foram obtidos valores basais para escore de sedação, pressão arterial sistólica e eletrocardiografia, além do índice de tônus vaso vagal (ITVV). Após dez minutos da aplicação intramuscular (IM) de DEX 5μg/kg todos os exames foram repetidos. Após a DEX, sedação suave foi detectada, e a êmese e sialorreia foram efeitos adversos comuns, observados em média 7 minutos após a injeção IM. Ademais, os principais efeitos eletrocardiográficos foram redução na frequência cardíaca e aumento na amplitude da onda T. O ITVV mais elevado e surgimento de arritmia sinusal respiratória, bem como bradicardia sinusal em alguns gatos, sugerem que a DEX eleva o tônus parassimpático, e por esse motivo deve ser utilizada com cautela em pacientes com predisposição à bradicardia.(AU)


Assuntos
Animais , Gatos , Gatos , Dexmedetomidina , Sedação Profunda , Agonistas de Receptores Adrenérgicos alfa 2 , Bradicardia/veterinária
7.
Pesqui. vet. bras ; 39(2): 142-147, Feb. 2019. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-20954

Resumo

In feline veterinary practice sedation is often needed to perform diagnostic or minimally invasive procedures, minimize stress, and facilitate handling. The mortality rate of cats undergoing sedation is significantly higher than dogs, so it is fundamental that the sedatives provide good cardiovascular stability. Dexmedetomidine (DEX) is an α2-adrenergic receptor agonist utilized in cats to provide sedation and analgesia, although studies have been utilized high doses, and markedly hemodynamic impairments were reported. The aim of this study was to prospectively investigate how the sedative and electrocardiographic effects of a low dose of DEX performing in cats. Eleven healthy cats were recruited; baseline sedative score, systolic arterial pressure, electrocardiography, and vasovagal tonus index (VVTI) were assessed, and repeated after ten minutes of DEX 5μg/kg intramuscularly (IM). A smooth sedation was noticed, and emesis and sialorrhea were common adverse effects, observed on average seven minutes after IM injection. Furthermore, electrocardiographic effects of a low dose of DEX mainly include decreases on heart rate, and increases on T-wave amplitude. The augmentation on VVTI and appearance of respiratory sinus arrhythmia, as well as sinus bradycardia in some cats, suggesting that DEX enhances parasympathetic tonus in healthy cats, and therefore will be best avoid in patients at risk for bradycardia.(AU)


Na rotina clínica da medicina veterinária felina a sedação é frequentemente requerida para realização de procedimentos diagnósticos ou minimamente invasivos, para minimizar o estresse e facilitar o manuseio dos pacientes. A taxa de mortalidade de gatos submetidos à sedação é mais elevada do que em cães, por esse motivo, é fundamental que os sedativos confiram estabilidade hemodinâmica. A dexmedetomidina (DEX) é um α2-agonista utilizado em felinos para promover sedação e analgesia, porém os estudos têm utilizado doses elevadas, e com isso prejuízos hemodinâmicos importantes foram relatados. O objetivo desta investigação foi avaliar os efeitos sedativos e eletrocardiográficos da baixa dose de DEX em gatos. Para tal, onze felinos saudáveis foram recrutados, foram obtidos valores basais para escore de sedação, pressão arterial sistólica e eletrocardiografia, além do índice de tônus vaso vagal (ITVV). Após dez minutos da aplicação intramuscular (IM) de DEX 5μg/kg todos os exames foram repetidos. Após a DEX, sedação suave foi detectada, e a êmese e sialorreia foram efeitos adversos comuns, observados em média 7 minutos após a injeção IM. Ademais, os principais efeitos eletrocardiográficos foram redução na frequência cardíaca e aumento na amplitude da onda T. O ITVV mais elevado e surgimento de arritmia sinusal respiratória, bem como bradicardia sinusal em alguns gatos, sugerem que a DEX eleva o tônus parassimpático, e por esse motivo deve ser utilizada com cautela em pacientes com predisposição à bradicardia.(AU)


Assuntos
Animais , Gatos , Gatos , Dexmedetomidina , Sedação Profunda , Agonistas de Receptores Adrenérgicos alfa 2 , Bradicardia/veterinária
8.
Semina ciênc. agrar ; 38(1): 209-220, jan.-fev. 2017. tab
Artigo em Inglês | VETINDEX | ID: vti-24708

Resumo

The aims of this study were compare the electrocardiogram (ECG) and cardiopulmonary effects of methadone or morphine, both injected intravenously (IV) in dogs anesthetized with continuous infusion of propofol. Sixteen healthy female mongrel dogs were used in this study for elective ovariohysterectomy. The animals were allocated in random order into two groups assigned GME (methadone 0.3 mg kg-1, IV) or GMO (morphine 0.3 mg kg-1, IV). Parameters were evaluated: heart rate (HR), P-wave amplitude (Ps and PmV), interval between Ps and R waves (PR), QRS duration (QRS), R-wave amplitude (R), duration the interval between the Q and T waves (QT), systolic blood pressure (SBP), rectal temperature (RT), respiratory rate (RR), end tidal of carbon dioxide (ETCO2 ) and periferic oxyhemoglobin saturation (SpO2 ). Postoperative analgesia was assessed by mechanical nociceptive stimulus based on the scale proposed by Firth and Haldane (1999) and rescue analgesia based on the visual analogue scale. HR was lower in GME in relation to GMO. The P, PmV, PR, QRS, R and QT values remained within their normality tracks, showing no clinical importance. Apnea and ETCO2 increased in both groups. There was no difference between groups of the analgesic effects. It can be concluded that methadone and morphine promote similar cardiovascular effects after IV injection during surgery in dogs anesthetized with propofol by continuous rate infusion, however, when methadone used, assisted ventilation is required. In addition, both drugs promote postoperative analgesia until six hours.(AU)


O presente estudo teve como objetivo comparar as alterações no eletrocardiograma (ECG) e nos parâmetros cardiorrespiratórios da metadona ou morfina administrada pela via intravenosa (I.V.) em cães anestesiados com infusão intravenosa contínua de propofol. Foram utilizados 16 cadelas, sem raça definida submetidos ao procedimento de ovário-histerectomia. Os animais foram distribuídos aleatoriamente em dois grupos, designados como GME (metadona 0,3 mg kg-1, I.V.) ou GMO (morfina 0,3 mg kg-1, I.V.). Os parâmetros avaliados foram frequência cardíaca (FC), tempo e amplitude da onda P (Ps e PmV), intervalo entre as ondas P e R (PR), duração do complexo QRS (QRS), amplitude da onda R (R), duração do intervalo entre as ondas Q e T (QT), pressão arterial sistólica (PAS), temperatura retal (TR), frequência respiratória (f), tensão de dióxido de carbono no final da expiração (ETCO2 ) e saturação de oxigênio na hemoglobina (SpO2 ). A analgesia pós-operatória foi verificada seguindo a proposta de Firth e Haldane (1999) e o regaste analgésico baseado na escala análoga visual. A FC foi menor no GME comparativamente ao GMO. Os valores de Ps, PmV, PR, QRS, R e QT mantiveram-se dentro da normalidade em ambos os grupos e sem significado clínico. Apneia e incremento da ETCO2 em ambos os grupos. Não houve diferença nos efeitos analgésicos entre os grupos. Podemos concluir que a metadona e a morfina promovem efeitos cardiovasculares similares quando administradas I.V. durante o procedimento cirúrgico em cães anestesiados com propofol via infusão continua intravenosa, no entanto, quando a metadona é empregada, ventilação assistida é necessária. Além disso, os dois opioides promoveram analgesia por 6h00 no pós-operatório.(AU)


Assuntos
Animais , Cães , Cães/metabolismo , Cães/cirurgia , Eletrocardiografia/métodos , Eletrocardiografia/veterinária , Período Perioperatório/veterinária , Histerectomia/veterinária , Propofol/análise , Propofol/síntese química
9.
Tese em Português | VETTESES | ID: vtt-218808

Resumo

A cardiologia é uma área em ascensão da medicina veterinária e devido sua relevância na medicina esportiva equina, objetivou-se identificar a influência de do treinamento para o Freio de Ouro nos índices ecocardiográficos e eletrocardiográficos de equinos da raça Crioula. Foram avaliados 31 equinos da raça Crioula, de idade variando entre 5 e 12 anos, com peso médio de 400,23 ± 81,89 kg, altura média de 1.41 ± 0,03 m e perímetro torácico médio de 1,74 ± 0,05 m, distribuídos em dois grupos, sendo eles: Grupo 1: equinos em treinamento para o Freio de Ouro (n = 14); Grupo 2: equinos não treinados (n = 17). Os índices ecocardiográficos aferidos foram: diâmetro do átrio esquerdo (AE) e da aorta (AO) e a relação entre ambos, espessura de septo interventricular (SIV), parede livre do ventrículo esquerdo (PLVE), diâmetro interno do ventrículo esquerdo (DVE), volume sistólico final do ventrículo esquerdo (VSFVE), volume diastólico final do ventrículo esquerdo (VDFVE), espessamento fracional do septo interventricular (EFSIV), encurtamento fracional do diâmetro do ventrículo esquerdo (FEVE), MassaVE, fração de ejeção do ventrículo esquerdo (FE) e volume sistólico (VS). Para investigação dos parâmetros eletrocardiográficos avaliou-se a determinação do ritmo cardíaco, frequência cardíaca (bt/min), duração da onda P (ms), do complexo QRS (ms) e dos intervalos QT (ms), além das amplitudes (mV) da onda P, do complexo QRS, do segmento ST e da onda T na derivação DII. Nas derivações DI, DIII, aVR, aVL e aVF foram mensuradas as durações (ms) e as amplitudes (mV) dos respectivos complexos QRS (velocidade de 50 mm/s, 1cm=1mv), além da avaliação do eixo da onda P e do complexo QRS. Verificou-se diferença entre os grupos nos caracteres ecocardiográficos e eletrocardiográficos, representados pelas variáveis SIVd, SIVs, PPVEd, PPVEs, MassaVE, AO, AE e Duração T. Observou-se hipertrofia cardíaca concêntrica fisiológica nos equinos treinados quando comparados com os não treinados. Foi identificado ritmo sinusal normal como ritmo prevalente nos animais estudados. Portanto, há influência do treinamento em caracteres eco e eletrocardiográficos em equinos atletas da raça Crioula.


Cardiology is a growing area of veterinary medicine and due to its relevance in equine sports medicine, the aim was to identify the influence of training for the Freio de Ouro in the echocardiographic and electrocardiographic indices of Criollo horses. Thirty-one Criollo horses were evaluated, aged between 5 and 12 years, with averages weight of 400.23 ± 81.89kg, height of 1.41 ± 0.03m and chest circumference of 1.74 ± 0.05m, divided into two groups: horses in training for the Freio de Ouro (n = 14); untrained horses (n = 17). The echocardiographic indices measured were: left atrium (LA) and aorta (AO) diameters and the relationship between them, interventricular septum thickness (IVS), left ventricular free wall (LVLP), left ventricular inner diameter (LVD) , left ventricular end-systolic volume (LVSF), left ventricular end-diastolic volume (LVLV), interventricular septal fractional thickening (EFSIV), left ventricular fractional shortening (LVEF), LVMass, left ventricular ejection fraction (EF) and stroke volume (SV). To investigate the electrocardiographic parameters, the determination of heart rate, heart rate (bt/min), P wave duration (ms), QRS complex (ms) and QT intervals (ms), in addition to amplitudes (mV) were evaluated of the P wave, QRS complex, ST segment, and T wave in lead DII. In the DI, DIII, aVR, aVL and aVF leads, the durations (ms) and amplitudes (mV) of the respective QRS complexes (speed of 50 mm/s, 1cm=1mv) were measured, in addition to the evaluation of the P wave axis and of the QRS complex. There was a difference between the groups in the echocardiographic and electrocardiographic measures, represented by the variables SIVd, SIVs, PPVEd, PPVEs, MassaVE, AO, AE and Duration T. Physiological concentric cardiac hypertrophy was observed in trained horses when compared with untrained horses. Normal sinus was identified as the prevalent rhythm in the studied animals. Therefore, there is an influence of training in echo and electrocardiographic characters in Criollo horse athletes.

10.
Ci. Rural ; 46(5): 915-920, May 2016. tab
Artigo em Inglês | VETINDEX | ID: vti-29557

Resumo

The aim of this study was to evaluate the electrocardiographic parameters in Mangalarga Marchador horses submitted to marcha exercise. Twenty-four Mangalarga Marchador horses, thirteen females and eleven males, 6.4±2.7 years old with a mean weight of 428.3±24.7kg, were used. Electrocardiograms were recorded in two different moments: rest and immediately after exercise (40 minutes of aerobic exercise, marcha gait). The electrocardiographic variables analyzed were cardiac rhythm, heart rate (HR), duration of P wave, QRS complex, PR and QT intervals, amplitudes of P, R and T waves, and analysis of QT corrected (QTc) according to Bazett's formula (QT/RR). Variables were analyzed for normality with Kolmogorov-Smirnov test and paired t-test, considering P 0.05. Rhythm analysis revealed 91.7% of sinus rhythm and 8.3% of sinus arrhythmia in rest, with mean HR of 45.7±12.7 beats minute-1, and 100% of sinus tachycardia, with mean HR of 77.3±13.5 beats minute-1 after exercise (P 0.0001). In post-exercise, it was possible to observe decreases in P wave duration (P=0.0121), PR interval (P=0.0007) and QT interval (P 0.0001) and increase of QTc (P=0.0039) and R wave amplitude (P=0.0033). There were no significant differences for amplitude of P and T waves and QRS complex related to atrioventricular enlargement. Although QT interval decreased after exercise, there was an increase on QTc after exercise, indicating changes in ventricular repolarization. It was possible to conclude that the imposed exercise (marcha gait) led to electrocardiographic alterations without causing pathological arrhythmias.(AU)


O objetivo deste estudo foi avaliar os parâmetros eletrocardiográficos de equinos da raça Mangalarga Marchador antes e após a execução da marcha. Para tal, foram usados 24 equinos, treze fêmeas e onze machos, com idade média de 6,4±2,7 anos e peso médio de 428,3±24,7kg. Eletrocardiogramas foram registrados em dois momentos: antes e imediatamente após atividade física (40 minutos de marcha). As variáveis eletrocardiográficas analisadas foram ritmo cardíaco, frequência cardíaca (FC), duração da onda P, complexo QRS, intervalos PR e QT, amplitudes das ondas P, R e T e análise do QT corrigida (QTc) de acordo com a fórmula de Bazett (QT/RR). As variáveis foram analisadas quanto à normalidade (teste de Kolmogorov-Smirnov), seguido da comparação usando teste-t pareado (P 0,05). A análise revelou 91,7% de ritmo sinusal e 8,3% de arritmia sinusal no repouso, com FC média de 45,7±12,7bpm e 100% de taquicardia sinusal após o exercício, com FC média de 77,3±13,5bpm (P 0,0001). No pós-exercício, foi possível observar reduções significativas na duração da onda P (P=0,0121), no intervalo PR (P=0,0007) e no intervalo QT (P 0,0001), além de aumentos significativos de QTc (P=0,0039) e amplitude da onda R (P=0,0033). Não foram registradas diferenças para a amplitude das ondas P e T e na duração do complexo QRS. Apesar da redução no intervalo QT após o exercício, houve um aumento no QTc, indicando alterações na repolarização ventricular. Foi possível concluir que a atividade física (marcha) gerou alterações eletrocardiográficas, sem causar arritmias patológicas.(AU)


Assuntos
Animais , Cavalos , Eletrocardiografia/veterinária , Análise da Marcha/veterinária , Exercício Físico
11.
Pesqui. vet. bras ; 36(supl.1): 1-7, June 2016. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: lil-798020

Resumo

The objective aimed to describe the electrocardiographic behavior of parameters in Holstein pregnant cows and neonates during the perinatal period. The electrocardiograms were performed using a computerized electrocardiogram. The animals selected for the study were 23 cows and 18 neonates. Maternal electrocardiographic examinations were conducted in the 35, 28, 21, 14, 7 days and one-day pre -partum and the neonates were evaluated in six moments; at the time of birth, 7, 14, 21, 28 and 35 days after delivery. The evaluations were done in pre and post-delivery cows and into the group of neonates between female and male. For each electrocardiographic recording P-wave duration and amplitude, PR interval and the QRS complex duration, R, S-wave amplitude and polarity, QT and RR interval duration were examined. Changes in heart rate, ST segment and T wave polarity were recorded in leads of Einthoven and base-apex planes. The mean electrical axis of the QRS complex was calculated. In cows the results when comparing the two leads system, there are significant changes in the amplitude of the waves P, R, S, and T and the duration of the intervals PR, ST and QRS complex. The difference between primiparous and multiparous dairy cows was in the amplitude of the Twave. It was concluded that the base-apex system is a suitable lead for monitoring heart rhythm in Holstein cows and Einthoven in neonates. During the first month of life, no differences in P, Q, S and T waves, in PR, QRS, and ST intervals and in axis orientation was observed in neonates. There was a significant difference in duration of the QT interval. Among sexes, the difference was in the Q amplitude. This study incorporated the calves and Holstein cows in a single study in search of baseline information regarding the duration and morphology of the ECG parameters. In conclusion, it was proved that, with increasing age, there are changes in ECG components associated with variations in the distance between the recording electrode and the heart. The study contributes by providing Holstein reference values for clinical evaluations.(AU)


Tem como objetivo descrever o comportamento eletrocardiográfico de parâmetros em vacas da raça Holandesa grávidas e recém-nascidos durante o período perinatal. Os eletrocardiogramas foram realizados utilizando um eletrocardiógrafo computadorizado. Os animais selecionados para o estudo foram 23 vacas e 18 neonatos. Exames eletrocardiográficos maternos foram realizadas em 35, 28, 21, 14, 7 dias e um dia de pré-parto e nos neonatos foram avaliados em seis momentos; no momento do nascimento, 7, 14, 21, 28 e 35 dias após o parto. As avaliações foram realizadas em vacas pré e pós-parto e no grupo de neonatos entre fêmeas e machos. Para cada duração da gravação eletrocardiográfica analisou-se onda P e amplitude, intervalo PR e da duração do complexo QRS, R, S amplitude de onda e polaridade, QT e duração do intervalo RR. Mudanças na frequência cardíaca, segmento ST e polaridade da onda T foram registradas. A média do eixo eléctrico do complexo QRS foi calculada. Em vacas, há mudanças significativas na amplitude das ondas P, R, S, T, e a duração dos complexos QRS e intervalos PR e ST. A diferença entre as vacas leiteiras multíparas e primíparas estava na amplitude da onda T. Concluiu-se que o sistema base-ápice é adequado para monitorar o ritmo cardíaco em vacas da raça Holandesa e o Einthoven em neonatos. Nos neonatos durante o primeiro mês de vida, não houve diferenças nas ondas P, Q, S e T, em intervalos PR, QRS, e ST e na orientação do eixo. Houve diferença significativa na duração do intervalo QT. Entre os sexos, a diferença estava na amplitude Q. O presente estudo incorporou os bezerros e vacas da raça Holandesa em um único estudo, em busca de informações em relação a duração e morfologia dos parâmetros do ECG. Conclui-se portanto que, com o aumento da idade, ocorrem alterações nos componentes do ECG, associadas com as variações na distância entre o elétrodo de registo e o coração. O estudo contribui, fornecendo valores de referência de bovinos da raça Holandesa para avaliações clínicas.(AU)


Assuntos
Animais , Feminino , Recém-Nascido , Bovinos , Animais Recém-Nascidos , Eletrocardiografia/veterinária , Frequência Cardíaca/fisiologia , Valores de Referência , Fenômenos Fisiológicos Cardiovasculares
12.
Pesqui. vet. bras ; 36(supl.1): 1-7, June 2016. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-8300

Resumo

The objective aimed to describe the electrocardiographic behavior of parameters in Holstein pregnant cows and neonates during the perinatal period. The electrocardiograms were performed using a computerized electrocardiogram. The animals selected for the study were 23 cows and 18 neonates. Maternal electrocardiographic examinations were conducted in the 35, 28, 21, 14, 7 days and one-day pre -partum and the neonates were evaluated in six moments; at the time of birth, 7, 14, 21, 28 and 35 days after delivery. The evaluations were done in pre and post-delivery cows and into the group of neonates between female and male. For each electrocardiographic recording P-wave duration and amplitude, PR interval and the QRS complex duration, R, S-wave amplitude and polarity, QT and RR interval duration were examined. Changes in heart rate, ST segment and T wave polarity were recorded in leads of Einthoven and base-apex planes. The mean electrical axis of the QRS complex was calculated. In cows the results when comparing the two leads system, there are significant changes in the amplitude of the waves P, R, S, and T and the duration of the intervals PR, ST and QRS complex. The difference between primiparous and multiparous dairy cows was in the amplitude of the Twave. It was concluded that the base-apex system is a suitable lead for monitoring heart rhythm in Holstein cows and Einthoven in neonates. During the first month of life, no differences in P, Q, S and T waves, in PR, QRS, and ST intervals and in axis orientation was observed in neonates. There was a significant difference in duration of the QT interval. Among sexes, the difference was in the Q amplitude. This study incorporated the calves and Holstein cows in a single study in search of baseline information regarding the duration and morphology of the ECG parameters. [...](AU)


Tem como objetivo descrever o comportamento eletrocardiográfico de parâmetros em vacas da raça Holandesa grávidas e recém-nascidos durante o período perinatal. Os eletrocardiogramas foram realizados utilizando um eletrocardiógrafo computadorizado. Os animais selecionados para o estudo foram 23 vacas e 18 neonatos. Exames eletrocardiográficos maternos foram realizadas em 35, 28, 21, 14, 7 dias e um dia de pré-parto e nos neonatos foram avaliados em seis momentos; no momento do nascimento, 7, 14, 21, 28 e 35 dias após o parto. As avaliações foram realizadas em vacas pré e pós-parto e no grupo de neonatos entre fêmeas e machos. Para cada duração da gravação eletrocardiográfica analisou-se onda P e amplitude, intervalo PR e da duração do complexo QRS, R, S amplitude de onda e polaridade, QT e duração do intervalo RR. Mudanças na frequência cardíaca, segmento ST e polaridade da onda T foram registradas. A média do eixo eléctrico do complexo QRS foi calculada. Em vacas, há mudanças significativas na amplitude das ondas P, R, S, T, e a duração dos complexos QRS e intervalos PR e ST. A diferença entre as vacas leiteiras multíparas e primíparas estava na amplitude da onda T. Concluiu-se que o sistema base-ápice é adequado para monitorar o ritmo cardíaco em vacas da raça Holandesa e o Einthoven em neonatos. Nos neonatos durante o primeiro mês de vida, não houve diferenças nas ondas P, Q, S e T, em intervalos PR, QRS, e ST e na orientação do eixo. Houve diferença significativa na duração do intervalo QT. Entre os sexos, a diferença estava na amplitude Q. O presente estudo incorporou os bezerros e vacas da raça Holandesa em um único estudo, em busca de informações em relação a duração e morfologia dos parâmetros do ECG. [...] (AU)


Assuntos
Animais , Feminino , Recém-Nascido , Bovinos , Eletrocardiografia/veterinária , Animais Recém-Nascidos , Frequência Cardíaca/fisiologia , Valores de Referência , Fenômenos Fisiológicos Cardiovasculares
13.
Arq. bras. med. vet. zootec. (Online) ; 68(6): 1613-1620, nov.-dez. 2016. tab, ilus
Artigo em Português | VETINDEX | ID: vti-17246

Resumo

O objetivo deste trabalho foi descrever os achados eletrocardiográficos de 11 onças- pardas (Puma concolor). Os animais foram sedados com 0,15mg/kg de detomidina associado a 5mg/kg de cetamina e mantidos anestesiados com sevoflurano (GSEVO, n=6) ou isoflurano (GISO, n=5). A frequência cardíaca foi de 95 ± 13bpm. As alterações observadas nos animais no GSEVO foram: atrial standtill com condução ventricular, episódios isolados de contração ventricular prematura, bloqueio atrioventricular de primeiro grau, diminuição da amplitude do complexo QRS, onda S profunda e aumento da amplitude da onda T. No grupo GISO, observou-se bloqueio de ramo direito do feixe de His, bloqueio atrioventricular de primeiro grau e aumento da amplitude da onda T. Arritmias não puderam ser associadas ao uso dos anestésicos inalatórios devido à não sensibilização do miocárdio às catecolaminas. Achados como o BAV de primeiro grau pode ter ocorrido devido ao uso de agonistas alfa-2 adrenérgicos. Este estudo aumentou o conhecimento sobre as alterações eletrocardiográficas em onças-pardas anestesiadas, entretanto mais estudos são necessários para correlacionar estes achados ao uso de agentes anestésicos.(AU)


The aim of this study was to describe electrocardiographic findings in pumas (Puma concolor). The animals were sedated with 0.15mg/kg of detomidine plus 5mg/kg of ketamine and anesthetized with sevoflurane (GSEVO, n=6), or isoflurane (GISO, n=5). The heart rate was 95 ± 13bpm. The changes observed on GSEVO animals were: atrial standstill with ventricular conduction, isolated episodes of ventricular premature contraction, atrioventricular blockage of first degree, reduction of the amplitude of the QRS complexes, deep S wave, and increase of the amplitude of the T wave. In the GISO group a right bundle branch block of the His bundle, atrioventricular blockage of first degree and of the amplitude of the T wave. Arrhythmias couldn´t be related to the use of inhalant anesthesia due to the lack of myocardial awareness to catecholamines. Findings such as atrioventricular block in first degree may have occurred due to the use of alfa-2 adrenergic agonists. This study improved the knowledge about electrocardiographic alterations in anesthetized pumas, however further studies are required to correlate these findings to the use of anesthetic agents.(AU)


Assuntos
Animais , Eletrocardiografia , Puma , Anestesia por Inalação/veterinária , Frequência Cardíaca , Anestesia Geral/veterinária , Isoflurano
14.
Vet. Zoot. ; 23(3): 476-482, set. 2016. tab
Artigo em Português | VETINDEX | ID: vti-686478

Resumo

Mycobacterium fortuitum es agente causante de enfermidad oportunista en humanos y animales. Es un agente biológico modelo para estudios experimentales que sustituy Mycobacterium bovis, que es más patógeno. Este estudio presenta una metodología alternativa para el recuento de unidades formadoras de colonias por mililitro de inóculo para determinar la concentración de Mycobacterium fortuitum usando espectrofotometría. Catorce muestras se utilizaron Mycobacterium fortuitum, cultivadas en Lowesntein-Jensen, ocho de ellos de siete días de cultivo, y la otra entre 8 y 14 días en la cultura. Todas las muestras se colocaron en placas y se incubaron a 37o.C durante 7 días en un invernadero. De cada muestra se hicieron lecturas las variables de absorbancia (Abs) y transmitancia (T%) en un espectrofotómetro, a una longitud de onda de 560 nm y 600 nm. La comparación de los valores de UFC, ABS y T% por análisis de regresión lineal simple, el estadístico SAS versión 8.2 del software, hubo una fuerte evidencia estadística de que el aumento del valor de transmitancia se asocia con la disminución en el valor de UFC chapado, siguiendo el modelo matemático: LOG10 (UFC) = 21,012 - 0,1936 * transmitancia, con p = 0,0025 y una repetibilidad de más de 80%.(AU)


Mycobacterium fortuitum is an opportunistic agent which causes disease in human and animals. It is also a biological model for experimental studies instead of using Mycobacterium bovis, which is more pathogenic. This work presents an alternative methodology using spectrophotometry to count colony forming units (CFU) per milliliter of inoculum, in order to determinate Mycobacterium fortuitum concentration. Fourteen Mycobacterium fortuitum samples were cultivated in Lowenstein-Jensen culture media, considering that eight of them were seven days old cultures and the others were between eight and 14 days old. All samples were seeded and incubated at 37o.C for 7 days in an incubator. For each sample, the variables absorbance (Abs) and transmitance (T%) were read with an spectrophotometer and wave length of 560nm and 600nm. When the values of CFU, Abs and T% were compared through simple linear regression analysis and using the statistic software SAS Version 8.2., it was observed strong statistical evidence that the increase of transmitance value is associated to the decrease of CFU plate values, according to the mathematic model: LOG10 (CFU) = 21.012 - 0.1936*Transmitance, and p value = 0.0025 and a repeatability over 80%.(AU)


O Mycobacterium fortuitum é um agente oportunista causador de doença em humanos e animais. Além disso, é um modelo biológico para estudos experimentais em substituição ao Mycobacterium bovis, que é mais patogênico. Este estudo apresenta metodologia alternativa à contagem de unidades formadoras de colônia por mililitro de inóculo, para determinar a concentração do Mycobacterium fortuitum utilizando espectrofotometria. Utilizaram-se 14 amostras de Mycobacterium fortuitum, cultivadas em meio Lowesntein-Jensen, sendo oito delas com sete dias de cultivo e as demais entre oito e 14 dias de cultivo. Todas as amostras foram semeadas e incubadas a 37o.C por 7 dias em estufa. Fizeram-se, de cada amostra, leituras das variáveis absorbância (Abs) e transmitância (T%) em espectrofotômetro, nos comprimentos de onda de 560nm e 600nm. Comparando-se os valores obtidos de UFC, Abs e T% por meio da análise de regressão linear simples, pelo programa estatístico SAS versão 8.2, observou-se forte evidência estatística que o aumento do valor da transmitância está associado com o decréscimo do valor de UFC em placas, seguindo o modelo matemático: LOG10 (UFC) = 21.012 - 0.1936*Transmitância, com valor de p = 0,0025 e uma repetibilidade de mais de 80%.(AU)


Assuntos
Mycobacterium fortuitum/isolamento & purificação , Espectrofotometria/veterinária , Contagem de Colônia Microbiana/veterinária
15.
Vet. zootec ; 23(3): 476-482, set. 2016. tab
Artigo em Português | VETINDEX | ID: biblio-1503346

Resumo

Mycobacterium fortuitum es agente causante de enfermidad oportunista en humanos y animales. Es un agente biológico modelo para estudios experimentales que sustituy Mycobacterium bovis, que es más patógeno. Este estudio presenta una metodología alternativa para el recuento de unidades formadoras de colonias por mililitro de inóculo para determinar la concentración de Mycobacterium fortuitum usando espectrofotometría. Catorce muestras se utilizaron Mycobacterium fortuitum, cultivadas en Lowesntein-Jensen, ocho de ellos de siete días de cultivo, y la otra entre 8 y 14 días en la cultura. Todas las muestras se colocaron en placas y se incubaron a 37o.C durante 7 días en un invernadero. De cada muestra se hicieron lecturas las variables de absorbancia (Abs) y transmitancia (T%) en un espectrofotómetro, a una longitud de onda de 560 nm y 600 nm. La comparación de los valores de UFC, ABS y T% por análisis de regresión lineal simple, el estadístico SAS versión 8.2 del software, hubo una fuerte evidencia estadística de que el aumento del valor de transmitancia se asocia con la disminución en el valor de UFC chapado, siguiendo el modelo matemático: LOG10 (UFC) = 21,012 - 0,1936 * transmitancia, con p = 0,0025 y una repetibilidad de más de 80%.


Mycobacterium fortuitum is an opportunistic agent which causes disease in human and animals. It is also a biological model for experimental studies instead of using Mycobacterium bovis, which is more pathogenic. This work presents an alternative methodology using spectrophotometry to count colony forming units (CFU) per milliliter of inoculum, in order to determinate Mycobacterium fortuitum concentration. Fourteen Mycobacterium fortuitum samples were cultivated in Lowenstein-Jensen culture media, considering that eight of them were seven days old cultures and the others were between eight and 14 days old. All samples were seeded and incubated at 37o.C for 7 days in an incubator. For each sample, the variables absorbance (Abs) and transmitance (T%) were read with an spectrophotometer and wave length of 560nm and 600nm. When the values of CFU, Abs and T% were compared through simple linear regression analysis and using the statistic software SAS Version 8.2., it was observed strong statistical evidence that the increase of transmitance value is associated to the decrease of CFU plate values, according to the mathematic model: LOG10 (CFU) = 21.012 - 0.1936*Transmitance, and p value = 0.0025 and a repeatability over 80%.


O Mycobacterium fortuitum é um agente oportunista causador de doença em humanos e animais. Além disso, é um modelo biológico para estudos experimentais em substituição ao Mycobacterium bovis, que é mais patogênico. Este estudo apresenta metodologia alternativa à contagem de unidades formadoras de colônia por mililitro de inóculo, para determinar a concentração do Mycobacterium fortuitum utilizando espectrofotometria. Utilizaram-se 14 amostras de Mycobacterium fortuitum, cultivadas em meio Lowesntein-Jensen, sendo oito delas com sete dias de cultivo e as demais entre oito e 14 dias de cultivo. Todas as amostras foram semeadas e incubadas a 37o.C por 7 dias em estufa. Fizeram-se, de cada amostra, leituras das variáveis absorbância (Abs) e transmitância (T%) em espectrofotômetro, nos comprimentos de onda de 560nm e 600nm. Comparando-se os valores obtidos de UFC, Abs e T% por meio da análise de regressão linear simples, pelo programa estatístico SAS versão 8.2, observou-se forte evidência estatística que o aumento do valor da transmitância está associado com o decréscimo do valor de UFC em placas, seguindo o modelo matemático: LOG10 (UFC) = 21.012 - 0.1936*Transmitância, com valor de p = 0,0025 e uma repetibilidade de mais de 80%.


Assuntos
Espectrofotometria/veterinária , Mycobacterium fortuitum/isolamento & purificação , Contagem de Colônia Microbiana/veterinária
16.
Pesqui. vet. bras ; 36(6): 551-558, jun. 2016. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: lil-792606

Resumo

The veterinary cardiology has growing importance in equine medicine. There are studies of standardization of electrocardiographic parameters of many races, according to their stature and ability. However, no studies are in the literature with the American Miniature Horse. To evaluate the electrocardiogram (ECG) tracing configuration of this breed at rest and to verify the influence of age and sex on ECG parameters, 203 horses including 143 females and 60 males were divided into four age groups (foals, yearlings, adults and elderly). Electrocardiographic parameters were performed by computerized electrocardiogram (TEB), and the parameters were evaluated in six leads of frontal plane (Lead I, II, III, aVR, aVL and aVF) and base-apex (BA). Heart rates (HR) decreased with increasing age were higher in males than in females. Sinus tachycardia followed by sinus arrhythmia was dominant in both sexes. The cardiac axis was higher in males and ranged between 120° and 150° for foals, 30° and 60° for yearlings and adults, and 60° and 90° for the elderly. The P wave was bifid in several animals. The P-wave amplitude and T-wave duration from lead II and BA were larger in males than in females. The majority of the animals exhibited ST segment depression and a negative T-wave. The most common QRS complex morphology was Qr. Differences were observed between the electrocardiographic tracings of males and females, and age influenced the ECG parameters. Therefore, this study established the ECG patterns for the American Miniature Horse breed and could be used to determine the influence of age and sex on several of the studied variables.(AU)


A cardiologia veterinária possui crescente importância na medicina equina. Existem estudos de padronização dos parâmetros eletrocardiográficos de muitas raças, de acordo com sua estatura e aptidão. No entanto, não há na literatura trabalhos com os equinos da raça Miniature Horse. Os objetivos deste trabalho foram avaliar a configuração do traçado do eletrocardiograma (ECG) em repouso, de equinos desta raça, além de verificar a influência do sexo e da idade sobre os parâmetros eletrocardiográficos desses animais. Foram utilizados 203 equinos desta raça, hígidos, sendo 143 fêmeas e 60 machos, classificados em quatro faixas etárias (potros, sobreanos, adultos e idosos). Os exames eletrocardiográficos foram realizados por eletrocardiograma computadorizado (TEB), e os parâmetros foram avaliados em seis derivações do plano frontal (DI, DII, DIII, aVR, aVL e aVF) e base-ápice (BA). A frequência cardíaca (FC) diminuiu com a progressão da idade, e foi maior nos machos do que nas fêmeas. O ritmo mais comum em ambos os sexos foi taquicardia sinusal, seguido de arritmia sinusal. O eixo cardíaco foi maior nos machos do que nas fêmeas, e nos potros ficou entre 120 e 150o, nos sobreano e adultos permaneceu entre 30 e 60o, e nos idosos entre 60 e 90o. A amplitude da onda P e a duração da onda T foram maiores nos machos do que nas fêmeas na DII e BA. A maioria dos animais apresentou segmento ST infradesnivelado e onda T negativa. A morfologia do complexo QRS mais encontrada em todos os casos foi Qr. Este estudo permitiu estabelecer os padrões eletrocardiográficos para a raça Mini Horse e conseguiu verificar a influência da progressão da idade nas diversas variáveis estudadas, bem como a diferença entre os sexos.(AU)


Assuntos
Animais , Arritmia Sinusal/veterinária , Eletrocardiografia/veterinária , Cavalos , Taquicardia Sinusal/veterinária , Técnicas de Diagnóstico Cardiovascular/veterinária , Frequência Cardíaca , Padrões de Referência
17.
Pesqui. vet. bras ; 36(6): 551-558, June 2016. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-339561

Resumo

The veterinary cardiology has growing importance in equine medicine. There are studies of standardization of electrocardiographic parameters of many races, according to their stature and ability. However, no studies are in the literature with the American Miniature Horse. To evaluate the electrocardiogram (ECG) tracing configuration of this breed at rest and to verify the influence of age and sex on ECG parameters, 203 horses including 143 females and 60 males were divided into four age groups (foals, yearlings, adults and elderly). Electrocardiographic parameters were performed by computerized electrocardiogram (TEB), and the parameters were evaluated in six leads of frontal plane (Lead I, II, III, aVR, aVL and aVF) and base-apex (BA). Heart rates (HR) decreased with increasing age were higher in males than in females. Sinus tachycardia followed by sinus arrhythmia was dominant in both sexes. The cardiac axis was higher in males and ranged between 120° and 150° for foals, 30° and 60° for yearlings and adults, and 60° and 90° for the elderly. The P wave was bifid in several animals. The P-wave amplitude and T-wave duration from lead II and BA were larger in males than in females. The majority of the animals exhibited ST segment depression and a negative T-wave. The most common QRS complex morphology was Qr. Differences were observed between the electrocardiographic tracings of males and females, and age influenced the ECG parameters. Therefore, this study established the ECG patterns for the American Miniature Horse breed and could be used to determine the influence of age and sex on several of the studied variables.(AU)


A cardiologia veterinária possui crescente importância na medicina equina. Existem estudos de padronização dos parâmetros eletrocardiográficos de muitas raças, de acordo com sua estatura e aptidão. No entanto, não há na literatura trabalhos com os equinos da raça Miniature Horse. Os objetivos deste trabalho foram avaliar a configuração do traçado do eletrocardiograma (ECG) em repouso, de equinos desta raça, além de verificar a influência do sexo e da idade sobre os parâmetros eletrocardiográficos desses animais. Foram utilizados 203 equinos desta raça, hígidos, sendo 143 fêmeas e 60 machos, classificados em quatro faixas etárias (potros, sobreanos, adultos e idosos). Os exames eletrocardiográficos foram realizados por eletrocardiograma computadorizado (TEB), e os parâmetros foram avaliados em seis derivações do plano frontal (DI, DII, DIII, aVR, aVL e aVF) e base-ápice (BA). A frequência cardíaca (FC) diminuiu com a progressão da idade, e foi maior nos machos do que nas fêmeas. O ritmo mais comum em ambos os sexos foi taquicardia sinusal, seguido de arritmia sinusal. O eixo cardíaco foi maior nos machos do que nas fêmeas, e nos potros ficou entre 120 e 150o, nos sobreano e adultos permaneceu entre 30 e 60o, e nos idosos entre 60 e 90o. A amplitude da onda P e a duração da onda T foram maiores nos machos do que nas fêmeas na DII e BA. A maioria dos animais apresentou segmento ST infradesnivelado e onda T negativa. A morfologia do complexo QRS mais encontrada em todos os casos foi Qr. Este estudo permitiu estabelecer os padrões eletrocardiográficos para a raça Mini Horse e conseguiu verificar a influência da progressão da idade nas diversas variáveis estudadas, bem como a diferença entre os sexos.(AU)


Assuntos
Animais , Cavalos , Eletrocardiografia/veterinária , Taquicardia Sinusal/veterinária , Arritmia Sinusal/veterinária , Padrões de Referência , Técnicas de Diagnóstico Cardiovascular/veterinária , Frequência Cardíaca
18.
Pesqui. vet. bras ; 36(6): 559-563, jun. 2016. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: lil-792615

Resumo

Considering the limited physiological information available on neotropical rodents and the importance of this information for pathophysiological and conservation studies of these species, the aim of this study was to evaluate the cardiac electric physiology of healthy captivity spotted pacas (Cuniculus paca) under chemical restraint, due to wild nature of these animals. Eleven adult female pacas were evaluated by blood count and biochemical dosage to rule out any associate disease. Each animal was evaluated in three periods every 15 days. After chemical restraint with intramuscular midazolam 0.5mg/kg and ketamine 25mg/kg, animals were subjected to a computerized electrocardiogram, where bipolar (DI, DII and DIII) and augmented unipolar leads (aVR, aVL, aVF) were obtained. Descriptive statistics were calculated for each parameter and built the confidence interval (CI) at significance level of 95%. The electrocardiographic examination was performed without difficult. ECG tracing in DII represents a QRS complex with positive polarity, preceded by a P wave of the same polarity and proceeded by T wave of variable polarity. Heart rate mean was 150±17 bpm, and cardiac electrical axis 33.4±21.9°. All animals showed sinusal rhythm. The ECG recording technique associated with chemical restraint was well tolerated, allowing quick acquisition of reliable ECG tracings with high repeatability, which produced sufficient results to determine the heart rhythm and suggest measures of ECG complexes duration and amplitude.(AU)


Considerando a limitada informação sobre a fisiologia cardíaca em roedores neotropicais e a importância desta informação para estudos fisiopatológicos e de conservação desta espécie, objetivou-se com este estudo avaliar a atividade elétrica cardíaca de pacas saudáveis mantidas em cativeiro, sob restrição química, devido à natureza selvagem destes animais. Onze fêmeas adultas foram avaliadas clinicamente e por meio do hemograma e testes bioquímicos no intuito de descartar qualquer co-morbidade associada. Cada animal foi submetido a três períodos experimentais a cada 15 dias. Após a restrição química com 25mg/kg de cetamina e 0,5mg/kg de midazolam pela via intramuscular, os animais eram submetidos a eletrocardiografia (ECG) computadorizada, aonde as derivações bipolares (DI, DII E DIII) e unipolares aumentadas (aVR, aVL, aVF) foram obtidas. A estatística descritiva foi calculada para cada parâmetro e o intervalo de confiança (CI), construído a um nível de significância de 95%. O exame eletrocardiográfico foi realizado sem dificuldade. O traçado eletrocardiográfico em DII apresentou QRS com polaridade positiva, precedido por onda P da mesma polaridade e seguida por onda T de polaridade variável. A frequência cardíaca média foi de 150±17 bpm e o eixo elétrico cardíaco de 33.4±21.9°. Todos os animais mostraram ritmo sinusal. A técnica eletrocardiográfica associada com restrição química foi bem tolerada permitindo a pratica aquisição de traçados de confiança e alta reprodutibilidade, que produziram resultados suficientes para determinar o ritmo cardíaco e sugerir medidas de duração e amplitude dos complexos de ECG.(AU)


Assuntos
Animais , Cuniculidae/fisiologia , Coração/fisiologia , Ketamina , Midazolam , Eletrocardiografia/veterinária , Roedores
19.
Pesqui. vet. bras ; 36(6): 559-563, June 2016. tab, graf, ilus
Artigo em Inglês | VETINDEX | ID: vti-339552

Resumo

Considering the limited physiological information available on neotropical rodents and the importance of this information for pathophysiological and conservation studies of these species, the aim of this study was to evaluate the cardiac electric physiology of healthy captivity spotted pacas (Cuniculus paca) under chemical restraint, due to wild nature of these animals. Eleven adult female pacas were evaluated by blood count and biochemical dosage to rule out any associate disease. Each animal was evaluated in three periods every 15 days. After chemical restraint with intramuscular midazolam 0.5mg/kg and ketamine 25mg/kg, animals were subjected to a computerized electrocardiogram, where bipolar (DI, DII and DIII) and augmented unipolar leads (aVR, aVL, aVF) were obtained. Descriptive statistics were calculated for each parameter and built the confidence interval (CI) at significance level of 95%. The electrocardiographic examination was performed without difficult. ECG tracing in DII represents a QRS complex with positive polarity, preceded by a P wave of the same polarity and proceeded by T wave of variable polarity. Heart rate mean was 150±17 bpm, and cardiac electrical axis 33.4±21.9°. All animals showed sinusal rhythm. The ECG recording technique associated with chemical restraint was well tolerated, allowing quick acquisition of reliable ECG tracings with high repeatability, which produced sufficient results to determine the heart rhythm and suggest measures of ECG complexes duration and amplitude.(AU)


Considerando a limitada informação sobre a fisiologia cardíaca em roedores neotropicais e a importância desta informação para estudos fisiopatológicos e de conservação desta espécie, objetivou-se com este estudo avaliar a atividade elétrica cardíaca de pacas saudáveis mantidas em cativeiro, sob restrição química, devido à natureza selvagem destes animais. Onze fêmeas adultas foram avaliadas clinicamente e por meio do hemograma e testes bioquímicos no intuito de descartar qualquer co-morbidade associada. Cada animal foi submetido a três períodos experimentais a cada 15 dias. Após a restrição química com 25mg/kg de cetamina e 0,5mg/kg de midazolam pela via intramuscular, os animais eram submetidos a eletrocardiografia (ECG) computadorizada, aonde as derivações bipolares (DI, DII E DIII) e unipolares aumentadas (aVR, aVL, aVF) foram obtidas. A estatística descritiva foi calculada para cada parâmetro e o intervalo de confiança (CI), construído a um nível de significância de 95%. O exame eletrocardiográfico foi realizado sem dificuldade. O traçado eletrocardiográfico em DII apresentou QRS com polaridade positiva, precedido por onda P da mesma polaridade e seguida por onda T de polaridade variável. A frequência cardíaca média foi de 150±17 bpm e o eixo elétrico cardíaco de 33.4±21.9°. Todos os animais mostraram ritmo sinusal. A técnica eletrocardiográfica associada com restrição química foi bem tolerada permitindo a pratica aquisição de traçados de confiança e alta reprodutibilidade, que produziram resultados suficientes para determinar o ritmo cardíaco e sugerir medidas de duração e amplitude dos complexos de ECG.(AU)


Assuntos
Animais , Cuniculidae/fisiologia , Coração/fisiologia , Ketamina , Midazolam , Eletrocardiografia/veterinária , Roedores
20.
Arq. bras. med. vet. zootec ; 68(6): 1613-1620, nov.-dez. 2016. tab, ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-827943

Resumo

O objetivo deste trabalho foi descrever os achados eletrocardiográficos de 11 onças- pardas (Puma concolor). Os animais foram sedados com 0,15mg/kg de detomidina associado a 5mg/kg de cetamina e mantidos anestesiados com sevoflurano (GSEVO, n=6) ou isoflurano (GISO, n=5). A frequência cardíaca foi de 95 ± 13bpm. As alterações observadas nos animais no GSEVO foram: atrial standtill com condução ventricular, episódios isolados de contração ventricular prematura, bloqueio atrioventricular de primeiro grau, diminuição da amplitude do complexo QRS, onda S profunda e aumento da amplitude da onda T. No grupo GISO, observou-se bloqueio de ramo direito do feixe de His, bloqueio atrioventricular de primeiro grau e aumento da amplitude da onda T. Arritmias não puderam ser associadas ao uso dos anestésicos inalatórios devido à não sensibilização do miocárdio às catecolaminas. Achados como o BAV de primeiro grau pode ter ocorrido devido ao uso de agonistas alfa-2 adrenérgicos. Este estudo aumentou o conhecimento sobre as alterações eletrocardiográficas em onças-pardas anestesiadas, entretanto mais estudos são necessários para correlacionar estes achados ao uso de agentes anestésicos.(AU)


The aim of this study was to describe electrocardiographic findings in pumas (Puma concolor). The animals were sedated with 0.15mg/kg of detomidine plus 5mg/kg of ketamine and anesthetized with sevoflurane (GSEVO, n=6), or isoflurane (GISO, n=5). The heart rate was 95 ± 13bpm. The changes observed on GSEVO animals were: atrial standstill with ventricular conduction, isolated episodes of ventricular premature contraction, atrioventricular blockage of first degree, reduction of the amplitude of the QRS complexes, deep S wave, and increase of the amplitude of the T wave. In the GISO group a right bundle branch block of the His bundle, atrioventricular blockage of first degree and of the amplitude of the T wave. Arrhythmias couldn´t be related to the use of inhalant anesthesia due to the lack of myocardial awareness to catecholamines. Findings such as atrioventricular block in first degree may have occurred due to the use of alfa-2 adrenergic agonists. This study improved the knowledge about electrocardiographic alterations in anesthetized pumas, however further studies are required to correlate these findings to the use of anesthetic agents.(AU)


Assuntos
Animais , Anestesia por Inalação/veterinária , Eletrocardiografia , Frequência Cardíaca/efeitos dos fármacos , Puma , Anestesia Geral/veterinária , Isoflurano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA