Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 502
Filtrar
1.
Anim. Reprod. (Online) ; 20(1): e20220079, 2023. tab
Artigo em Inglês | VETINDEX | ID: biblio-1418572

Resumo

Logistic and economical limitations are often the causes of dog owners not accurately monitoring the estrous cycle and the optimal insemination time. The aim of this study was to evaluate in vivo early embryonic development in bitches, after the analysis of sequential vaginal cytologies associated to single progesterone measurement and single laparoscopic insemination with high quality semen (fresh and with high spermatozoa concentration) or low-quality semen (frozen/thawed and with low spermatozoa concentration) at 48 h post- ovulation time predicted on a single progesterone measurement. Ten bitches were inseminated with 250 x 106 fresh spermatozoa (80% motility), and ten with 80 x 106 frozen/thawed spermatozoa (60% motility) in the cranial part of each uterine horn. Seven days later, ovariohysterectomy was performed and the oviducts and uterine horns and body were flushed to recover embryos and unfertilized oocytes. In 80% of the bitches inseminated with fresh and 50% of bitches inseminated with frozen/thawed semen, embryos at 2 to 8 cells stage were recovered mostly from the, oviducts. This study indicates that pregnancies can be obtained with a single laparoscopic intrauterine insemination after single serum progesterone measurement, although with a low number of embryos. This result should be taken into account in case economic or logistic restrictions that affect the possibility of owners to plan an accurate monitoring of the optimal breeding time using fresh and frozen semen.(AU)


Assuntos
Animais , Feminino , Progesterona/administração & dosagem , Laparoscopia/métodos , Cães/embriologia , Desenvolvimento Embrionário , Inseminação
2.
Ciênc. rural (Online) ; 53(9): e20210902, 2023. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1418775

Resumo

This study evaluated the feasibility of abdominal liftfor laparoscopic adrenalectomy and compared it with the conventional laparoscopic technique using pneumoperitoneum with medicinal CO2 in dog cadavers. The total surgical time (TST), adrenalectomy time (AT), and gland integrity after removal were evaluated. Thirty-eight adrenalectomies were performed in 19 cadavers. Regardless of the antimere, the TST was significantly lower in the CO2 procedures than in the lift laparoscopy procedures (P=0.001). When comparing the techniques between antimeres, the TST was significantly higher on the left side with lift laparoscopy than with CO2 (P=0.015) and similar between the techniques on the right side of the animals (P=0.086). In the comparison of AT, regardless of the execution side, no differences were observed between the techniques (P=0.05). The same was observed when AT was evaluated separately using antimeres (P=0.902). Of the 38 adrenals evaluated, 92.1% were removed in a single block, and 32.29% had a superficial lesion in the capsule. There was no difference between the groups in the removal capacity in a single block (P=0.340) and capsule integrity (P=0.287). Abdominal lift for laparoscopic adrenalectomy is a feasible technique in dog cadavers; however, it requires a longer surgical time than the conventional technique. The traction force used to elevate the abdominal wall must be evaluated.


O presente trabalho teve como objetivo avaliar a exequibilidade da adrenalectomia laparoscópica utilizando dispositivo de elevação da parede abdominal via liftlaparoscopy e comparar com a técnica laparoscópica convencional utilizando pneumoperitônio com CO2 medicinal em cadáveres de cães. Para isso, avaliou-se tempo cirúrgico total (TCT), tempo de adrenalectomia (TA) e integridade das glândulas após remoção. Foram realizadas 38 adrenalectomias em 19 cadáveres. Independentemente do antímero, o TCT foi significativamente menor nos procedimentos com CO2 do que com liftlaparoscopy (P=0,001). Na comparação das técnicas entre antímeros, o TCT foi significativamente maior no lado esquerdo com liftlaparoscopy do que com CO2 (P = 0,015) e semelhante entre as técnicas no lado direito dos animais (P=0,086). Já na comparação do TA, independente do lado de execução, não foram observadas diferenças entre os métodos (P=0,05). O mesmo foi observado quando o TA foi avaliado separadamente por antímero (P=0,902). Das 38 adrenais avaliadas, 92,1% foram removidas em um único bloco e destas, 32,29% apresentaram lesão superficial na cápsula. Não houve diferença entre grupos para capacidade de remoção em um único bloco (P=0,340) e da integridade da cápsula (P=0,287). A adrenalectomia laparoscópica por elevação da parede abdominal é factível de ser realizada em cadáveres de cães, entretanto, demanda maior tempo cirúrgico quando comparada à técnica convencional. Além disso, a força de tração empregada para elevar a parede abdominal necessita ser avaliada.


Assuntos
Animais , Cães , Pneumoperitônio/veterinária , Cadáver , Laparoscopia/veterinária , Adrenalectomia/veterinária , Doenças do Cão
3.
Acta Vet. Brasilica ; 17(1): 21-27, 2023. tab
Artigo em Inglês | VETINDEX | ID: biblio-1436292

Resumo

Laparoscopy procedures are useful tools to perform some assisted reproductive biotechnologies in ewes, it requi-res general anesthesia and manoeuvres that might result in alteration of the cardiopulmonary function. For this reason, this study aimed to investigate the effects of oxygen supplementation as a therapeutic measure to mitigate these alterations in ewes submitted to laparoscopic ovum pick-up (LOPU) under total intravenous anesthesia (TIVA). Twenty-four healthy adult ewes were submitted to two LOPUs with a 21 days interval, under ketamine-midazolam anesthesia, and receiving each of the two experimental in random order, oxygen treatment (OT) 50 mL/kg/min of oxygen via endotracheal tube and control treatment (CT) not receive any inhalation treatment. Heart rate (HR), respiratory rate (fR), peripheral oxygen saturation (SpO2), mean arterial pressure (MAP), rectal temperature (RT), end-tidal CO2 concentration (EtCO2) and recovery anesthesia time were evaluated during LOPU, arterial blood gases and electrolytes were evaluated after induction of anesthesia and at the end of the LOPU. Variables were compared between groups and moments using ANOVA. MAP, SpO2, PaO2, SaO2 and pH were higher in OT, while EtCO2, PaCO2, temperature loss and recovery time were lower. These results allow to conclude that oxy-gen supplementation in ewes submitted to LOPU under TIVA provides benefits in order to mitigate physiological alterations.(AU)


Os procedimentos de laparoscopia são ferramentas úteis para realizar algumas biotecnologias de reprodução assistida em ovelhas, requer anestesia geral e manobras que podem resultar em alteração da função cardiopulmonar. Por esse motivo, este estudo teve como objetivo investigar os efeitos da suplementação de oxigênio como medida terapêutica para atenuar as alterações em ovelhas submetidas à Aspiração Folicular guiada por Laparoscopia (LOPU) sob anestesia venosa total (TIVA). Vinte e quatro ovelhas adultas saudáveis foram submetidas a duas LOPUs com intervalo de 21 dias, sob anestesia com cetamina-midazolam, recebendo cada um dos dois experimentos em ordem aleatória, tratamento com oxigênio (OT) 50 mL/kg/min de oxigênio via tubo endotraqueal e tratamento de controle (CT) não recebem nenhum tratamento por inalação. Frequência cardíaca (FC), frequência respiratória (FR), saturação periférica de oxigênio (SpO2), pressão arterial média (PAM), temperatura retal (TR), concentração expirada de CO2 (EtCO2) e tempo de recuperação da anestesia foram avaliados durante LOPU, arterial gasometria e eletrólitos foram avaliados após a indução da anestesia e ao final da COL. As variáveis foram comparadas entre grupos e momentos por meio de ANOVA. PAM, SpO2, PaO2, SaO2 e pH foram maiores no TO, enquanto EtCO2, PaCO2, perda de temperatura e tempo de recuperação foram menores. Estes resultados permitem concluir que a suplementação de oxigênio em ovelhas submetidas a LOPU sob TIVA proporciona benefícios no sentido de atenuar as alterações fisiológicas.(AU)


Assuntos
Animais , Oxigênio/efeitos adversos , Ovinos/cirurgia , Laparoscopia/veterinária , Anestesia Intravenosa/métodos , Biotecnologia , Ketamina/análise
4.
Rev. bras. reprod. anim ; 47(2): 140-143, abr.-jun. 2023.
Artigo em Português | VETINDEX | ID: biblio-1435094

Resumo

A onça-pintada encontra-se classificada como "quase ameaçada" na lista vermelha de animais ameaçados da União Internacional para Conservação da Natureza (IUCN), com tendência ao declínio na América Latina, o que pode afetar o fluxo gênico elevando o risco de endogamia. Técnicas de reprodução assistida (TRAs) como colheita de sêmen e inseminação artificial (IA), são ferramentas que podem se tornar essenciais a manutenção da diversidade genética desses animais. A colheita de sêmen pode ser realizada por eletroejaculação (EEJ) ou colheita farmacológica (CF), sendo que podem ser aplicadas individualmente ou associadas, embora EEJ tenha se mostrado mais eficiente em inseminação artificial (IA) com sêmen a fresco. Para realização de IA a utilização de progestina oral (altrenogest), seguida da aplicação de gonadotropinas exógenas (Gonadotropina Coriônica equina-eCG e Hormônio Luteinizante suíno-pLH), tem se mostrado eficiente, promovendo ovulações consistentes. IA intratubárica (IA-IT) mostrou-se eficiente, tendo a vantagem de utilizar sêmen com baixo número de espermatozoides. O sucesso alcançado com o nascimento do primeiro filhote de Panthera onca utilizando TRAs se deve a vários fatores, dentre eles, a utilização de um novo protocolo hormonal ajustado à espécie; e a utilização da IA-IT, que possibilitou a utilização de sêmen com reduzido número de espermatozoides viáveis por inseminação.(AU)


The jaguar is classified as "near threatened" according International Union for Conservation of Nature red list, with a decreasing trend in the population of Latin America, increasing the risk of inbreeding. Assisted reproduction techniques (ARTs), such as semen collection and artificial insemination (AI), are tools that can become essential to maintain the genetic diversity of jaguars. Semen collection can be performed by electroejaculation (EEJ) or pharmacological collection (PC); and can be applied individually or associated, however EEJ was more efficient for artificial insemination (AI) with fresh semen. To perform Artificial Insemination (AI), oral progestin (altrenogest) followed exogenous gonadotropins (Gonadotropin Chorionic equine-eCG e Hormone Luteinizing porcine-pLH) application was efficient, promoting consistent ovulations. Similarly, laparoscopic oviductal insemination (IA-IT) was efficient, with the advantage to use low viable spermatozoa number by insemination. The success of jaguar cub birth using ARTs is due to several factors, among than, a new hormonal protocol adjusted to the species; and the use of IA-IT, which allowed the reduction in the number of sperm by insemination.(AU)


Assuntos
Animais , Inseminação Artificial/veterinária , Panthera , Análise do Sêmen/veterinária , Laparoscopia/métodos , Técnicas de Reprodução Assistida/instrumentação
5.
Acta cir. bras ; 38: e382723, 2023. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1505462

Resumo

Purpose: To compare laparoscopic gynecological surgery training between a developed country's reference center (host center) and a public reference service in a developing country (home center), and use the technicity index (TI) to compare outcomes and to determine the impact of laparoscopic gynecological surgery fellowship training on the home center's TI. Methods: The impact of training on the home center was assessed by comparing surgical performance before and after training. TI was assessed in 2017 in the host center, and before and after training in the home center. Epidemiological and clinical data, and information on reason for surgery, preoperative images, estimated intraoperative bleeding, operative time, surgical specimen weight, hospital stay length, complication and reintervention rates were collected from both institutions. Home center pre-training data were retrospectively collected between 2010 and 2013, while post-training data were prospectively collected between 2015 and 2017. A two-tail Z-score was used for TI comparison. Results: The analysis included 366 hysterectomies performed at the host center in 2017, and 663 hysterectomies performed at the home center between 2015 and 2017. TI in the host center was 82.5%, while in the home center it was 6% before training and 22% after training. There were no statistical differences in length of hospital stay, preoperative uterine volume, surgical specimen weight and complication rate between centers. However, significantly shorter mean operative time and lower blood loss during surgery were observed in the host center. Conclusions: High-quality laparoscopic training in a world-renowned specialized center allowed standardizing laparoscopic hysterectomy procedures and helped to significantly improve TI in the recipient's center with comparable surgical outcomes.


Assuntos
Humanos , Saúde Pública , Laparoscopia , Países em Desenvolvimento , Técnicas de Diagnóstico Obstétrico e Ginecológico
6.
Arq. bras. med. vet. zootec. (Online) ; 74(2): 245-252, Mar.-Apr. 2022. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1374415

Resumo

The aim of the present study is to describe the surgical technique and complications of uterine elevation by laparoscopic surgery, using the broad uterine ligament plication with toogles. Five mares of different breeds, weight and age were selected, presenting poor perineal conformation and pendulous uterus. The surgical technique was performed with a toogle applicator, 0.6mm sterile nylon thread and toogles, using three portals on each side of the flank. After one month, a new laparoscopy was performed, with only one portal on each side, to observe uterine positioning and healing. The average surgical time reached in this study was 82 minutes per procedure, and the uterus of all mares was successfully raised, remaining in a more horizontal orientation and presenting satisfactory healing. There are only two articles published with uteropexy in mares, where the proposed techniques take longer, which consequently increases the surgical risk.


O objetivo do presente estudo é descrever a técnica cirúrgica e as complicações da elevação uterina por cirurgia laparoscópica, utilizando-se a plicatura do ligamento uterino com aplicação de toogles. Foram selecionadas cinco éguas de diferentes raças, peso e idade, as quais apresentavam baixa conformação perineal e útero pendular. A técnica cirúrgica foi realizada com aplicador de toogles, fio de nylon estéril de 0,6mm e toogles, sendo utilizados três portais de cada lado do flanco. Após um mês, uma nova laparoscopia foi realizada, com apenas um portal de cada lado, para observar o posicionamento uterino e a cicatrização. O tempo cirúrgico médio alcançado neste estudo foi de 82 minutos por procedimento, e o útero de todas as éguas foi elevado com sucesso, permanecendo em uma orientação mais horizontal e apresentando cicatrização satisfatória. Existem apenas dois artigos publicados com a utilização da uteropexia em éguas, porém nestes as técnicas propostas demoram mais, o que, consequentemente, aumenta o risco cirúrgico.


Assuntos
Animais , Feminino , Útero/cirurgia , Laparoscopia/métodos , Cavalos , Laparoscopia/veterinária
7.
Arq. bras. med. vet. zootec. (Online) ; 74(4): 741-744, July-Aug. 2022. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1393906

Resumo

O objetivo deste estudo foi identificar o melhor acesso laparoscópico para visualização e manipulação das estruturas umbilicais no interior da cavidade abdominal de fetos bovinos. Foram utilizados nove fetos de bezerros de vacas no terço final da gestação, todos submetidos à laparoscopia com dois portais de acesso, primeiro no flanco direito e depois na região ventral do abdômen, onde foram verificadas as possibilidades de acesso às estruturas umbilicais. Em ambas as abordagens, os portais de acesso permitiram visualizar e manipular as estruturas de interesse, mas a abordagem lateral foi mais eficaz com melhor visualização e manipulação. Os acessos ventrais não proporcionavam a mesma facilidade de visualização e manipulação, pois as estruturas umbilicais fixadas na parede abdominal ficavam muito próximas aos portais. Esses resultados demonstram que a laparoscopia pode ser utilizada para manipulação e visualização das estruturas umbilicais, sendo a abordagem lateral mais eficaz.


Assuntos
Animais , Bovinos , Umbigo , Laparoscopia , Cavidade Abdominal , Feto
8.
Ciênc. Anim. (Impr.) ; 32(3): 191-199, jul.-set. 2022. ilus
Artigo em Português | VETINDEX | ID: biblio-1402659

Resumo

A urolitíase é uma condição rara, mas considerada de emergência na rotina de equinos. Este trabalho relata um caso de correção de urolitíase vesical em equino pela técnica cirúrgica de laparocistotomia parainguinal a campo. Para isso, foi realizado atendimento de um equino macho, sem raça definida, com histórico de disúria e hematúria exacerbada após exercício. Após realização de exame clínico, a suspeita diagnóstica de urolitíase vesical foi confirmada por meio de ultrassonografia transretal, sendo indicado o tratamento cirúrgico. Diante da impossibilidade de realização do procedimento em centro cirúrgico, optou-se por operá-lo em condições a campo. Para o acesso à cavidade abdominal, optou-se pela laparotomia parainguinal. A bexiga foi localizada e esvaziada por punção. Procedeu-se cistotomia para remoção do urólito, seguida da lavagem da bexiga com solução fisiológica para remoção de possíveis detritos. A cistorrafia foi realizada em dois planos de sutura do tipo Schmieden-Cushing, com fio absorvível sintético, seguida pela laparorrafia. O pós-operatório consistiu em curativos diários da ferida cirúrgica, duchas e administração de antimicrobiano e anti-inflamatório. Conclui-se que o exame ultrassonográfico foi fundamental para o correto diagnóstico e que a escolha da técnica cirúrgica de laparocistotomia parainguinal realizada a campo oferece resultados satisfatórios para o tratamento de equino com urolitíase vesical.


Urolithiasis is a rare condition, but it is considered an emergency in the equine routine. The present work reports a correction case of vesical urolithiasis in equines by the surgical technique of parainguinal laparocystotomy in the field. A male horse, of mixed breed, with a history of dysuria and exacerbated hematuria after exercise was treated. After performing the clinical examination, the diagnostic suspicion of bladder urolithiasis was confirmed through transrectal ultrasonography and the surgical treatment was indicated. Given the impossibility of performing the procedure in the operating room, it was decided to operate the animal in field conditions. For access to the abdominal cavity, parainguinal laparotomy was chosen. The bladder was located and emptied by puncture. A cystotomy was performed to remove the urolith, followed by washing the bladder with saline solution to remove possible debris. The cistorrhaphy was performed in two planes of Schmieden-Cushing suture, with synthetic absorbable suture, followed by laparorrhaphy. The postoperative period consisted of daily dressings of the surgical wound, showers, and administration of antimicrobial and anti-inflammatory. It is concluded that the ultrasound examination was essential for the correct diagnosis and that the choice of the surgical technique of parainguinal laparocystotomy performed in the field offers satisfactory results for the treatment of horses with bladder urolithiasis.


Assuntos
Animais , Masculino , Cálculos da Bexiga Urinária/diagnóstico por imagem , Urolitíase/cirurgia , Cavalos/cirurgia , Laparoscopia/veterinária
9.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1487622

Resumo

ABSTRACT: This study aimed to evaluate laparoscopy with abdominal ultrasound exams to establish accurate diagnosis and prognosis. The experimental design was a prospective clinical study. Nine adult crossbred bovines suffering from abdominal disorders were admitted to the cattle clinic for clinical examinations. Abdominal ultrasound was carried out, and complete blood counts were performed. Subsequently, exploratory laparoscopy was performed. After surgery (exploratory laparoscopy on the right or left side), animals with a severe prognosis or untreatable clinical condition were euthanised and necropsied. During laparoscopy, circumscribed reticuloperitonitis could not be detected, nor could other abnormalities in the cranioventral region of the abdomen previously observed on ultrasound and confirmed during necropsy. However, alterations due to peritoneal damage, such as adhesions, were observed dorsally in addition to alterations in macroscopic aspects of the peritoneal fluid. Exploratory standing laparoscopy through the paralumbar fossae may constitute a supplementary procedure for diagnosing abdominal disorders in cattle, but it is not suitable in cases of diseases characterised by focal lesions concentrated in the cranioventral region of the abdomen. When associated with clinical, laboratory, and ultrasound examinations, this technique may improve the accurate diagnosis and prognosis of abdominal disorders in cattle.


RESUMO: Este estudo teve como objetivo avaliar a laparoscopia com exames de ultrassom abdominal para estabelecer um diagnóstico e prognóstico precisos. O desenho experimental foi um estudo clínico prospectivo. Nove bovinos adultos mestiços com distúrbios abdominais foram utilizados. Os bovinos admitidos na Clínica de Bovinos foram submetidos a exame clínico, adicionalmente foram realizadas hemograma e ultrassonografia abdominal. Posteriormente, foi realizada laparoscopia exploratória. Após a cirurgia (laparoscopia exploratória no lado direito ou esquerdo), nove animais com manifestações clínicas graves e intratáveis foram sacrificados e necropsiados. Durante a laparoscopia, não foi possível detectar reticuloperitonite circunscrita, bem como outras anormalidades na região crânio-ventral do abdome, previamente observadas na ultrassonografia e confirmadas durante a necropsia. No entanto, alterações devido a dano peritoneal, como aderências, foram observadas dorsalmente. É possível que a laparoscopia exploratória em apoio quadrupedal através da fossa paralombar constitua um procedimento complementar para o diagnóstico de distúrbios abdominais em bovinos, embora não seja adequado em casos de doenças caracterizadas por lesões focais concentradas na região cranioventral do abdome. Quando associada a exames clínicos, laboratoriais e de ultrassom, essa técnica pode melhorar o diagnóstico e prognóstico preciso dos distúrbios abdominais em bovinos.

10.
Ciênc. rural (Online) ; 51(09): 1-4, 2021. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1480210

Resumo

This case report presents a celioscopy procedure followed by partial salpingectomy (PS) in a pregnant bitch referred to elective video assisted ovariohysterectomy. Through celioscopy it was visualized the embryonic vesicles and PS was performed after conversion to minioceliotomy. The puppies were born by eutocic delivery without clinical alterations. The case suggested that short and regular pneumoperitoneum is not deleterious to dog fetus and video surgery could be used in pregnant bitches. PS allows the fetus development and promotes bitch neutering.


Este trabalho relata um caso de celioscopia seguido de salpingectomia parcial (SP) em fêmea canina gestante encaminhada à ovariohisterectomia eletiva videoassistida. Por celioscopia foram identificadas vesículas gestacionais e a SP foi aplicada após conversão para miniceliotomia. Não foram observadas alterações clínicas nos filhotes, os quais nasceram por parto eutócico. Sugere-se que o pneumoperitônio regular por tempo reduzido não seja deletério para fetos caninos e a videocirurgia pode ser aplicada em caninos gestantes. A SP permite a continuidade do desenvolvimento fetal e a esterilização de fêmeas caninas.


Assuntos
Feminino , Animais , Cães , Desenvolvimento Fetal , Doenças do Cão/cirurgia , Doenças do Cão/diagnóstico , Laparoscopia/veterinária , Salpingectomia/veterinária
11.
Acta sci. vet. (Impr.) ; 49: Pub. 1836, 2021. tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-1363704

Resumo

Videolaparoscopic procedures have gained prominence due to their low invasiveness, causing less surgical trauma and better post-surgical recovery. However, the increase in intra-abdominal pressure due to the institution of pneumoperitoneum can alter the patient's homeostasis. Therefore, volume-controlled ventilation, associated with positive end-expiratory pressure (PEEP), improves arterial oxygenation and prevents pulmonary collapse, but it can lead to important hemodynamic changes. The aim of this study was to evaluate, comparatively, the effects of positive end expiratorypressure (PEEP) on hemodynamic variables of pigs submitted to volume-controlled ventilation, during pneumoperitoneum and maintained in head-down tilt and determine which PEEP value promotes greater stability on hemodynamic variables. Twenty-four pigs were used, between 55 and 65-day-old, weighing between 15 and 25 kg, randomly divided into 3 distinct groups differentiated by positive end-expiratory pressure: PEEP 0 (volume-controlled ventilation and PEEP of 0 cmH2O), PEEP 5 (volume-controlled ventilation and PEEP of 5 cmH2O) and PEEP 10 (volume-controlled ventilation and PEEP of 10 cmH2O). Volume-controlled ventilation was adjusted to 8 mL/kg of tidal volume and a respiratory rate of 25 movements per min. Anesthesia was maintained with continuous infusion of propofol (0.2 mg/kg/min) and midazolam (1 mg/kg/h). Pneumoperitoneum was performed with carbon dioxide (CO2), keeping the intraabdominal pressure at 15 mmHg and the animals were positioned on a 30° head-down tilt. The evaluations of hemodynamic variables started 30 min after induction of anesthesia (M0), followed by measurements at 15-min intervals (from M15 to M90), completing a total of 7 evaluations. The variables of interest were collected over 90 min and submitted to analysis of variance followed by Tukey's post-hoc test, with P < 0.05. The PEEP 10 group had higher values of CVP and mCPP, while the PEEP 5 group, mPAP and PVR were higher. The PEEP 0 group, on the other hand, had higher means of CI. Regarding the moments, there were differences in HR, SAP, DAP, MAP, CO, IC and TPR. According to the literature, important hemodynamic effects due to pneumoperitoneum are reported, which can be caused by the pressure used in abdominal insufflation, CO2 accumulation, duration of the surgical procedure, hydration status and patient positioning. Mechanical ventilation associated with PEEP can also cause an increase in intrathoracic pressure and, therefore, reduce cardiac output. Cardiovascular changes are proportional to the PEEP used. Central venous pressure (PVC) measure the patient's preload, and intrathoracic pressure can interfere with this parameter. The peak pressure values in the PEEP 10 group were higher than the other groups, demonstrating that the increase in intrathoracic pressure results in higher PVC values. Regarding PAPm and PCPm, these variables can be influenced according to the PEEP values and the patient's position. In relation to CI, the increase in PEEP may reflect on intrathoracic pressure, resulting in greater compression of the heart, with a consequent reduction in cardiac output and cardiac index. Therefore, it is concluded that the PEEP effects of 0 cmH2O and 5 cmH2O on hemodynamics are discrete, under the proposed conditions.(AU)


Assuntos
Animais , Pneumoperitônio , Respiração Artificial , Volume de Ventilação Pulmonar , Laparoscopia/veterinária , Decúbito Inclinado com Rebaixamento da Cabeça/efeitos adversos , Suínos
12.
Ci. Rural ; 51(09): 1-4, 2021. ilus
Artigo em Inglês | VETINDEX | ID: vti-32037

Resumo

This case report presents a celioscopy procedure followed by partial salpingectomy (PS) in a pregnant bitch referred to elective video assisted ovariohysterectomy. Through celioscopy it was visualized the embryonic vesicles and PS was performed after conversion to minioceliotomy. The puppies were born by eutocic delivery without clinical alterations. The case suggested that short and regular pneumoperitoneum is not deleterious to dog fetus and video surgery could be used in pregnant bitches. PS allows the fetus development and promotes bitch neutering.(AU)


Este trabalho relata um caso de celioscopia seguido de salpingectomia parcial (SP) em fêmea canina gestante encaminhada à ovariohisterectomia eletiva videoassistida. Por celioscopia foram identificadas vesículas gestacionais e a SP foi aplicada após conversão para miniceliotomia. Não foram observadas alterações clínicas nos filhotes, os quais nasceram por parto eutócico. Sugere-se que o pneumoperitônio regular por tempo reduzido não seja deletério para fetos caninos e a videocirurgia pode ser aplicada em caninos gestantes. A SP permite a continuidade do desenvolvimento fetal e a esterilização de fêmeas caninas.(AU)


Assuntos
Animais , Feminino , Cães , Doenças do Cão/diagnóstico , Doenças do Cão/cirurgia , Desenvolvimento Fetal , Salpingectomia/veterinária , Laparoscopia/veterinária
13.
Pesqui. vet. bras ; 41: e06845, 2021. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1279540

Resumo

This study aimed to evaluate laparoscopy with abdominal ultrasound exams to establish accurate diagnosis and prognosis. The experimental design was a prospective clinical study. Nine adult crossbred bovines suffering from abdominal disorders were admitted to the cattle clinic for clinical examinations. Abdominal ultrasound was carried out, and complete blood counts were performed. Subsequently, exploratory laparoscopy was performed. After surgery (exploratory laparoscopy on the right or left side), animals with a severe prognosis or untreatable clinical condition were euthanised and necropsied. During laparoscopy, circumscribed reticuloperitonitis could not be detected, nor could other abnormalities in the cranioventral region of the abdomen previously observed on ultrasound and confirmed during necropsy. However, alterations due to peritoneal damage, such as adhesions, were observed dorsally in addition to alterations in macroscopic aspects of the peritoneal fluid. Exploratory standing laparoscopy through the paralumbar fossae may constitute a supplementary procedure for diagnosing abdominal disorders in cattle, but it is not suitable in cases of diseases characterised by focal lesions concentrated in the cranioventral region of the abdomen. When associated with clinical, laboratory, and ultrasound examinations, this technique may improve the accurate diagnosis and prognosis of abdominal disorders in cattle.(AU)


Este estudo teve como objetivo avaliar a laparoscopia com exames de ultrassom abdominal para estabelecer um diagnóstico e prognóstico precisos. O desenho experimental foi um estudo clínico prospectivo. Nove bovinos adultos mestiços com distúrbios abdominais foram utilizados. Os bovinos admitidos na Clínica de Bovinos foram submetidos a exame clínico, adicionalmente foram realizadas hemograma e ultrassonografia abdominal. Posteriormente, foi realizada laparoscopia exploratória. Após a cirurgia (laparoscopia exploratória no lado direito ou esquerdo), nove animais com manifestações clínicas graves e intratáveis foram sacrificados e necropsiados. Durante a laparoscopia, não foi possível detectar reticuloperitonite circunscrita, bem como outras anormalidades na região crânio-ventral do abdome, previamente observadas na ultrassonografia e confirmadas durante a necropsia. No entanto, alterações devido a dano peritoneal, como aderências, foram observadas dorsalmente. É possível que a laparoscopia exploratória em apoio quadrupedal através da fossa paralombar constitua um procedimento complementar para o diagnóstico de distúrbios abdominais em bovinos, embora não seja adequado em casos de doenças caracterizadas por lesões focais concentradas na região cranioventral do abdome. Quando associada a exames clínicos, laboratoriais e de ultrassom, essa técnica pode melhorar o diagnóstico e prognóstico preciso dos distúrbios abdominais em bovinos.(AU)


Assuntos
Animais , Bovinos , Bovinos/anormalidades , Ultrassonografia/veterinária , Laparoscopia/veterinária , Sinais e Sintomas , Doenças do Sistema Digestório/diagnóstico
14.
Pesqui. vet. bras ; 41: e06845, 2021. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-33446

Resumo

This study aimed to evaluate laparoscopy with abdominal ultrasound exams to establish accurate diagnosis and prognosis. The experimental design was a prospective clinical study. Nine adult crossbred bovines suffering from abdominal disorders were admitted to the cattle clinic for clinical examinations. Abdominal ultrasound was carried out, and complete blood counts were performed. Subsequently, exploratory laparoscopy was performed. After surgery (exploratory laparoscopy on the right or left side), animals with a severe prognosis or untreatable clinical condition were euthanised and necropsied. During laparoscopy, circumscribed reticuloperitonitis could not be detected, nor could other abnormalities in the cranioventral region of the abdomen previously observed on ultrasound and confirmed during necropsy. However, alterations due to peritoneal damage, such as adhesions, were observed dorsally in addition to alterations in macroscopic aspects of the peritoneal fluid. Exploratory standing laparoscopy through the paralumbar fossae may constitute a supplementary procedure for diagnosing abdominal disorders in cattle, but it is not suitable in cases of diseases characterised by focal lesions concentrated in the cranioventral region of the abdomen. When associated with clinical, laboratory, and ultrasound examinations, this technique may improve the accurate diagnosis and prognosis of abdominal disorders in cattle.(AU)


Este estudo teve como objetivo avaliar a laparoscopia com exames de ultrassom abdominal para estabelecer um diagnóstico e prognóstico precisos. O desenho experimental foi um estudo clínico prospectivo. Nove bovinos adultos mestiços com distúrbios abdominais foram utilizados. Os bovinos admitidos na Clínica de Bovinos foram submetidos a exame clínico, adicionalmente foram realizadas hemograma e ultrassonografia abdominal. Posteriormente, foi realizada laparoscopia exploratória. Após a cirurgia (laparoscopia exploratória no lado direito ou esquerdo), nove animais com manifestações clínicas graves e intratáveis foram sacrificados e necropsiados. Durante a laparoscopia, não foi possível detectar reticuloperitonite circunscrita, bem como outras anormalidades na região crânio-ventral do abdome, previamente observadas na ultrassonografia e confirmadas durante a necropsia. No entanto, alterações devido a dano peritoneal, como aderências, foram observadas dorsalmente. É possível que a laparoscopia exploratória em apoio quadrupedal através da fossa paralombar constitua um procedimento complementar para o diagnóstico de distúrbios abdominais em bovinos, embora não seja adequado em casos de doenças caracterizadas por lesões focais concentradas na região cranioventral do abdome. Quando associada a exames clínicos, laboratoriais e de ultrassom, essa técnica pode melhorar o diagnóstico e prognóstico preciso dos distúrbios abdominais em bovinos.(AU)


Assuntos
Animais , Bovinos , Bovinos/anormalidades , Ultrassonografia/veterinária , Laparoscopia/veterinária , Sinais e Sintomas , Doenças do Sistema Digestório/diagnóstico
15.
Acta sci. vet. (Impr.) ; 49(suppl.1): Pub.624-Jan 4, 2021. ilus
Artigo em Português | VETINDEX | ID: biblio-1458487

Resumo

Background: Incisional hernia in the midline can be a consequence of abdominal surgeries, which incidence is around5.7-18%. Surgical indication occurs in cases of large hernias, and the most common techniques used involve the closingof the musculature in a primary way, with sutures, and the implantation of a mesh on the abdominal wall. Laparoscopichernioplasty emerged as a less invasive option, showing superiority when compared with open surgical techniques in human medicine, however there are few reports describing this technique in equines. So, the aim of this paper is to report acase of hernioplasty, using laparoscopic mesh, in a horse with midline incisional hernia.Case: A 13-year-old castrated male Brasileiro de Hipismo horse, weighing 415 kg, practitioner of classic equestrian, presented an incisional hernia after 14 days from an exploratory laparotomy surgery realized to treat colic syndrome. After 6months, the patient was referred to a Veterinary Medicine Teaching Hospital for the correction of the defect in the abdominal wall. During palpation, the animal did not present local pain or other sign of inflammation, and the hernia measuredapproximately 20 cm in diameter. The animal was submitted to general anesthesia and placed in dorsal decubitus for thehernioplasty surgical procedure. An incision was made in cranial region of the midline, close to the xiphoid to introduce asingle port; the abdomen was inflated with CO2 gas (12 mmHg) and the operating table was tilted in order to displace theorgans cranially, facilitating the laparoscopic procedure. The abdomen was inspected and the presence of a single adherence could be observed, which was disrupted with endoscopic forceps. The mesh was introduced through the single port...


Assuntos
Masculino , Animais , Cavalos/cirurgia , Hérnia Incisional/cirurgia , Hérnia Incisional/veterinária , Laparoscopia/veterinária , Infecções por Pseudomonas/veterinária
16.
Acta sci. vet. (Online) ; 49(suppl.1): Pub. 624, 4 abr. 2021. ilus
Artigo em Português | VETINDEX | ID: vti-763432

Resumo

Background: Incisional hernia in the midline can be a consequence of abdominal surgeries, which incidence is around5.7-18%. Surgical indication occurs in cases of large hernias, and the most common techniques used involve the closingof the musculature in a primary way, with sutures, and the implantation of a mesh on the abdominal wall. Laparoscopichernioplasty emerged as a less invasive option, showing superiority when compared with open surgical techniques in human medicine, however there are few reports describing this technique in equines. So, the aim of this paper is to report acase of hernioplasty, using laparoscopic mesh, in a horse with midline incisional hernia.Case: A 13-year-old castrated male Brasileiro de Hipismo horse, weighing 415 kg, practitioner of classic equestrian, presented an incisional hernia after 14 days from an exploratory laparotomy surgery realized to treat colic syndrome. After 6months, the patient was referred to a Veterinary Medicine Teaching Hospital for the correction of the defect in the abdominal wall. During palpation, the animal did not present local pain or other sign of inflammation, and the hernia measuredapproximately 20 cm in diameter. The animal was submitted to general anesthesia and placed in dorsal decubitus for thehernioplasty surgical procedure. An incision was made in cranial region of the midline, close to the xiphoid to introduce asingle port; the abdomen was inflated with CO2 gas (12 mmHg) and the operating table was tilted in order to displace theorgans cranially, facilitating the laparoscopic procedure. The abdomen was inspected and the presence of a single adherence could be observed, which was disrupted with endoscopic forceps. The mesh was introduced through the single port...(AU)


Assuntos
Animais , Masculino , Hérnia Incisional/cirurgia , Hérnia Incisional/veterinária , Laparoscopia/veterinária , Cavalos/cirurgia , Infecções por Pseudomonas/veterinária
17.
Ciênc. Anim. (Impr.) ; 31(4): 163-173, 2021. ilus
Artigo em Português | VETINDEX | ID: biblio-1369508

Resumo

As práticas cirúrgicas dentro da medicina veterinária vêm se aperfeiçoando ao longo do tempo com o desenvolvimento de técnicas cada vez menos invasivas, visando à diminuição da dor e a recuperação mais rápida da função das estruturas operadas. Este relato teve como objetivo evidenciar os benefícios da técnica de ressecção de um cisto renal por meio de videolaparoscopia em um canino, fêmea, da raça Golden Retriever, castradoe com 10 anos que apresentava histórico de apatia. No exame ultrassonográfico foi evidenciada estrutura cortical no rim direito, sugestiva de cisto renal. Foi realizada a confirmação do diagnóstico e posterior drenagem do cisto de forma percutânea videoassistida, seguida de sua ressecção e omentopexia por técnica laparoscópica a fim de garantir boa condição cicatricial, drenagem de urina e aporte de células de defesa. A técnica apresentou ausência de complicações durante o procedimento, mínima dor no pós-operatório e recuperação rápida do paciente. A análise histopatológica do fragmento retirado do cisto confirmou o diagnóstico de cisto epitelial benigno, que é a forma mais comum de cistos renais, fornecendo um bom prognóstico para o paciente. Não houve complicações ou sinais de recidiva três meses após o procedimento. Os cistos renais ocorrem com pouca frequência em animais domésticos e geralmente não causam sinais clínicos, porém se em grande número ou tamanho considerável podem causar doença renal crônica cursando com sinais clínicos sistêmicos além da deformação renal e dor abdominal. No caso relatado, a ressecção cirúrgica do cisto renal simples por videocirurgia foi eficaz, sem complicações e preservou a função do órgão.


Surgical practices within veterinary medicine have been improving over time with the development of increasingly less invasive techniques, aimed at reducing pain and faster recovery of the function of operated structures. This report aimed to highlight the benefits due a technique of resection of a simple renal cyst through video laparoscopy. A ten years old canine, female, Golden Retriever had history of apathy. Ultrasound examination found a cortical structure in the right kidney, suggestive of renal cyst. Diagnosis was confirmed and the cyst was drained through percutaneously video-assisted technique, followed by its resection and omentopexy by laparoscopic technique in order to ensure a good healing condition, urine drainage and supply of defense cells. The technique showed no complications during the procedure, less pain in the postoperative period and faster recovery of the patient. Histopathology of the fragment removed from the cyst was performed and the diagnosis of benign epithelial cyst was confirmed, which is the most common form of renal cysts, providing a good prognosis for the patient. There were no complications or signs of recurrence three months after the procedure. Renal cysts occur infrequently in domestic animals and generally do not cause clinical signs, but if in large numbers or considerable size is presented, they can cause chronic kidney disease with systemic clinical signs in addition to renal deformation and abdominal pain. In this case, laparoscopic resection of the simple renal cyst was effective, without complications and preserved the organ's function.


Assuntos
Animais , Feminino , Cães , Cistos/cirurgia , Cistos/veterinária , Rim/cirurgia , Laparoscopia/veterinária , Procedimentos Cirúrgicos Minimamente Invasivos/veterinária , Cirurgia Vídeoassistida/veterinária
18.
Acta cir. bras. ; 36(1): e360108, 2021. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-30518

Resumo

Purpose Develop a 3D model for the simulation of laparoscopic inguinal hernioplasty transabdominal preperitoneal (TAPP). Methods This is an experimental study, 18 participants were selected, divided into three groups, experimental (GE) surgeons in training, control (GC) experienced surgeons and Shaw (GS) nonexperienced surgeons. The simulation in the 3D model was carried out in 6 sessions fulfilling the 5 stages. Opening the peritoneum with the creation of the preperitoneal space; identification of important structures; hernia identification and reduction; placement and fixation of the mesh in Coopers ligament and closure of the peritoneum. Results In the 1st stage, the GE obtained an average of 1.25 ± 0.42 in the 1st session and 3.25 ± 0.62 in the 6th session (p = 0.05) and in the 5th stage 0.91 ± 0.29 in the first session. 1st session and 1.91 ± 0.29 in the 6th session (p = 0.001), with no significant difference between groups. The learning and skill curve in the SG represented 1.08 ± 0.29 1st and 3.50 ± 0.90 6th session (p = 0.001). Conclusions The creation of a systematization of training in simulation applied to the three-dimensional model enabled gain in laparoscopic skills and underpinned its theoretical and practical foundations.(AU)


Assuntos
Treinamento por Simulação , Hérnia Inguinal , Laparoscopia , Impressão Tridimensional
19.
Acta Vet. Brasilica ; 15(4): 287-291, 2021. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1453300

Resumo

This work aims to describe the clinical, laboratory, and anatomopathological findings of two bovines, one affected by cecocolic intussusception, and the other by dilation with cecal torsion. The clinical examination demonstrated metallic resonance from the right flank, ruminal and intestinal hypomotility, and abdominal distension, in addition to alterations in feces characteristics. Was observed in the two animals leukocytosis by neutrophilia with regenerative shift to the left, and hyperfibrinogenemia. The analysis of ruminal fluid revealed impairment of the microbiota and an increase in chloride levels. The laparoscopic examination performed on one of the animals showed dilation of the colon, the cecum with hyperemia and serous edema, with a dividing halo between affected and unaffected portions, in addition to reddish peritoneal fluid. In the laparotomy, an enlarged cecum was found, with gaseous and liquid contents, swollen and turgid colon, and peritonitis. In addition to the findings observed during surgery, the anatomopathological examination demonstrated, in bovine 01, intestinal intussusception in the region of the cecocolic valve, and, in bovine 02, twisting of the loop at the ileocecocolic junction. Despite the low occurrence of digestive system disorders in cattle, cecal torsion and intussusception represent serious intestinal clinical conditions. These reports take the attention to the importance of a multidisciplinary approach to provide a correct diagnosis of intestinal diseases.


O objetivo deste trabalho foi descrever os achados clínicos, laboratoriais e anatomopatológicos de dois bovinos, um acometido por intussuscepção cecocólica e o outro por dilatação com torção de ceco. O diagnóstico de ambos os casos foi base-ado nos achados clínicos, laboratoriais, videolaparoscópicos, cirúrgicos e anatomopatológicos. No exame clínico evidenciou-se ressonância metálica no flanco direito, hipomotilidade ruminal e intestinal, distensão abdominal, além de alteração nas carac-terísticas das fezes. Observou-se nos dois animais leucocitose por neutrofilia com desvio para esquerda regenerativo e hiperfi-brinogenia. A análise do fluido ruminal revelou comprometimento da microbiota e elevação nos teores de cloretos. O exame videolaparoscópico, realizado no bovino dois (02), evidenciou dilatação do cólon, ceco com hiperemia e edema de serosa com halo divisório entre porção acometida e não acometida, além de líquido peritoneal de coloração avermelhada. Na laparotomia constatou-se ceco dilatado por conteúdo gasoso e líquido, cólon edemaciado e túrgido e, peritonite. No exame anatomopato-lógico, constatou-se, no bovino um (01), intussuscepção intestinal na região de válvula ceco-cólica e, no bovino (02) torção de alça na junção ileocecocólica. Apesar da baixa ocorrência, a torção de ceco e a intussuscepção acarretam condição intestinal grave e devem ser inseridas na lista de diagnósticos diferenciais das enfermidades digestivas de bovinos. Estes relatos chamam a atenção para a importância da abordagem multidisciplinar no diagnóstico das enfermidades intestinais.


Assuntos
Animais , Bovinos , Intussuscepção/diagnóstico , Laparoscopia , Obstrução Intestinal/diagnóstico , Trato Gastrointestinal
20.
Acta Vet. bras. ; 15(4): 287-291, 2021. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-765278

Resumo

This work aims to describe the clinical, laboratory, and anatomopathological findings of two bovines, one affected by cecocolic intussusception, and the other by dilation with cecal torsion. The clinical examination demonstrated metallic resonance from the right flank, ruminal and intestinal hypomotility, and abdominal distension, in addition to alterations in feces characteristics. Was observed in the two animals leukocytosis by neutrophilia with regenerative shift to the left, and hyperfibrinogenemia. The analysis of ruminal fluid revealed impairment of the microbiota and an increase in chloride levels. The laparoscopic examination performed on one of the animals showed dilation of the colon, the cecum with hyperemia and serous edema, with a dividing halo between affected and unaffected portions, in addition to reddish peritoneal fluid. In the laparotomy, an enlarged cecum was found, with gaseous and liquid contents, swollen and turgid colon, and peritonitis. In addition to the findings observed during surgery, the anatomopathological examination demonstrated, in bovine 01, intestinal intussusception in the region of the cecocolic valve, and, in bovine 02, twisting of the loop at the ileocecocolic junction. Despite the low occurrence of digestive system disorders in cattle, cecal torsion and intussusception represent serious intestinal clinical conditions. These reports take the attention to the importance of a multidisciplinary approach to provide a correct diagnosis of intestinal diseases.(AU)


O objetivo deste trabalho foi descrever os achados clínicos, laboratoriais e anatomopatológicos de dois bovinos, um acometido por intussuscepção cecocólica e o outro por dilatação com torção de ceco. O diagnóstico de ambos os casos foi base-ado nos achados clínicos, laboratoriais, videolaparoscópicos, cirúrgicos e anatomopatológicos. No exame clínico evidenciou-se ressonância metálica no flanco direito, hipomotilidade ruminal e intestinal, distensão abdominal, além de alteração nas carac-terísticas das fezes. Observou-se nos dois animais leucocitose por neutrofilia com desvio para esquerda regenerativo e hiperfi-brinogenia. A análise do fluido ruminal revelou comprometimento da microbiota e elevação nos teores de cloretos. O exame videolaparoscópico, realizado no bovino dois (02), evidenciou dilatação do cólon, ceco com hiperemia e edema de serosa com halo divisório entre porção acometida e não acometida, além de líquido peritoneal de coloração avermelhada. Na laparotomia constatou-se ceco dilatado por conteúdo gasoso e líquido, cólon edemaciado e túrgido e, peritonite. No exame anatomopato-lógico, constatou-se, no bovino um (01), intussuscepção intestinal na região de válvula ceco-cólica e, no bovino (02) torção de alça na junção ileocecocólica. Apesar da baixa ocorrência, a torção de ceco e a intussuscepção acarretam condição intestinal grave e devem ser inseridas na lista de diagnósticos diferenciais das enfermidades digestivas de bovinos. Estes relatos chamam a atenção para a importância da abordagem multidisciplinar no diagnóstico das enfermidades intestinais.(AU)


Assuntos
Animais , Bovinos , Intussuscepção/diagnóstico , Obstrução Intestinal/diagnóstico , Trato Gastrointestinal , Laparoscopia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA