Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
Ciênc. rural (Online) ; 53(12): e20220027, 2023. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1434389

Resumo

Cervical arthroplasty with disc prosthesis has been proposed as a treatment option for dogs with Cervical Spondylomyelopathy. The present study developed a novel vertebral disc prosthesis for dogs. Sixteen Functional Spinal Units (C5-C6) were collected from dog cadavers with body weights ranging between 25 and 35 kg, and their vertebral measurements were used to design a prosthetic disc. The sizing of the prosthesis was performed based on the averages of the measurements of width, height, and length of the vertebral bodies from C5-C6 of all specimens. The prosthesis was developed using the Rhinoceros 3D® and SolidWorks® programs, and 3D prototyping was carried out to define the best design. The developed prosthesis consisted of two independent parts that are fixed to the cranial and caudal vertebral bodies, in the intervertebral space, and fitted together by metal-to-metal surfaces capable of moving in the lateral, ventral, and dorsal directions. Each part of the prosthesis is angled in two portions: vertically, in the intervertebral space, and horizontally, in contact with the ventral surface of the vertebral bodies, both of which are fixed by means of monocortical locking screws. The design of the developed prototype allowed a good fit in the intervertebral space between C4-C5, C5-C6, and C6-C7.


A artroplastia cervical com prótese de disco tem sido proposta como uma opção de tratamento para cães com Espondilomielopatia Cervical. O presente estudo teve como objetivo desenvolver uma nova prótese de disco intervertebral para cães. Dezesseis Unidades Funcionais de Coluna Vertebral (C5-C6) foram coletadas de cadáveres de cães com peso corporal variando entre 25 e 35 kg, e suas medidas vertebrais foram usadas para projetar um disco intervertebral protético. O dimensionamento da prótese foi realizado com base nas médias das mensurações da largura, altura e comprimento dos corpos vertebrais de C5-C6 de todos os espécimes. A prótese foi desenvolvida nos programas Rhinoceros 3D® e SolidWorks® e utilizou-se prototipagem em 3D para a definição do melhor design. A prótese desenvolvida é formada por duas partes independentes que se fixam às espífises dos corpos vertebrais cranial e caudalmente ao espaço intervertebral, e se encaixam entre si por superfícies de metal-metal com capacidade de movimentação nas direções lateral, ventral e dorsal. Cada parte da prótese é angulada em duas porções: a vertical, que fica no espaço intervertebral, e a horizontal, que fica em contato com a superfície ventral dos corpos vertebrais, ambas as quais são fixadas por meio de parafusos bloqueados monocorticais. O design do protótipo desenvolvido permitiu bom encaixe no espaço intervertebral entre C4-C5, C5-C6 e C6-C7.


Assuntos
Animais , Cães , Artroplastia/veterinária , Próteses e Implantes/veterinária , Doenças da Coluna Vertebral/veterinária , Doenças do Cão
2.
Ars vet ; 39(2): 34-39, 2023. ilus, tab, graf
Artigo em Português | VETINDEX | ID: biblio-1438478

Resumo

Diversos estudos relacionados à viabilidade e eficiência do uso de materiais alternativos ao globo de Vernon têm sido realizados, principalmente em decorrência ao preço elevado do cobre, componente do instrumento padrão. O objetivo foi avaliar a eficiência da utilização de caneca de alumínio como material alternativo para substituição do globo de Vernon. Para a confecção do protótipo empregou-se uma caneca de alumínio, utilizada em pistola de pintura, com capacidade de 50 ml. A caneca foi pintada com tinta preto-fosca, em duas camadas e um termômetro de mercúrio foi inserido ao centro. Para realização dos testes foram utilizados quatro equipamentos (dois globos de Vernon e dois globos negros alternativos). Foram efetuados testes prévios de comportamento temporal. Estabelecido o tempo, as temperaturas dos globos foram coletadas durante sete dias consecutivos, em três períodos, de 15 minutos cada. Os registros de temperatura foram realizados a cada cinco minutos, num total de 84 por equipamento. Os dados foram submetidos a análise de correlação de Pearson. Os resultados indicaram correlação positiva com o r2 de 0,9927, estabelecendo uma forte correlação entre os resultados de temperatura média do globo negro alternativo e globo de Vernon. Conclui-se que o globo negro alternativo do tipo caneca de alumínio mostrou-se eficiente para aferição da temperatura de globo negro em estudos de ambiência em substituição ao Globo de Vernon.(AU)


Several studies related to the feasibility and efficiency of using alternative materials to Vernon's globe have been carried out, mainly due to the high price of copper, a component of the standard instrument. The objective was to evaluate the efficiency of using an aluminum mug as an alternative material for replacing Vernon's globe. To make the prototype, an aluminum mug was used, used in a paint gun, with a capacity of 50 ml. The mug was painted with matte black paint, in two layers and a mercury thermometer was inserted in the center. Four pieces of equipment were used to carry out the tests (two Vernon globes and two alternative black globes). Previous temporal behavior tests were carried out. Once the time was established, the globes' temperatures were collected for seven consecutive days, in three periods of 15 minutes each. Temperature records were taken every five minutes, a total of 84 per equipment. Data were subjected to Pearson's correlation analysis. The results indicated a positive correlation with the r2 of 0.9927, establishing a strong correlation between the mean temperature results of the alternative black globe and Vernon's globe. It is concluded that the alternative black globe of the aluminum mug type proved tobe efficient for measuring the temperature of the black globe in ambience studies, replacing the Vernon Globe.(AU)


Assuntos
Bem-Estar do Animal , Proteínas Anticongelantes/análise , Alumínio/química
3.
Acta sci., Biol. sci ; 44: e60663, mar. 2022. graf, tab
Artigo em Inglês | VETINDEX | ID: biblio-1391124

Resumo

In this study, nickel tolerance (NiSO4.7H2O) of some Turkish national barley (Hordeum vulgare L.) genotypes (Bülbül-89, Kalayci-97, Karatay-94, Larende, Tarm-92, Tokak-157/37, Yesevi-93 and Zeynel Aga) was investigated. Barley genotypes were exposed to different nickel concentrations [0 mM (control), 250, 500, 1000, 1500, and 2000 ppm]. Nickel toxicity significantly inhibited root and coleoptile growth in all barley genotypes in a concentration-dependent manner. However, root growth was much more inhibited by nickel applications in comparison with coleoptile growth, probably due to a higher level of sensitivity of root meristems against nickel toxicity or direct contact of roots with nickel ions in the growth medium. Root growth in the genotype Karatay-94 and coleoptile growth in the genotype Yesevi-93 was more remarkably reduced by nickel toxicity. Root and coleoptile growth in the genotypes Larende and Kalayci-97 were less affected under nickel toxicity, respectively. In addition, nickel toxicity disturbed water relations in barley genotypes dependent on the organ type, as demonstrated by more severe inhibition in root fresh weight as compared to coleoptile fresh weight. These results could show that nickel toxicity reduced water uptake from growth medium in barley genotypes used in this study. Changes in dry weight of roots and coleoptiles indicated that nickel toxicity more severely decreased biomass accumulation in roots of barley genotypes. The calculated tolerance indices demonstrated that the genotype Kalayci-97 is the most tolerant to nickel toxicity, while the genotype Karatay-94 is the most susceptible one.(AU)


Assuntos
Hordeum/genética , Níquel/toxicidade , Níquel/química , Raízes de Plantas/química , Estudo de Prova de Conceito
4.
Braz. J. Vet. Res. Anim. Sci. (Online) ; 59: e181942, fev. 2022. tab, graf, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1363107

Resumo

The project is based on a test of a thoracic vibration vest prototype, adapted to equines by the Expector® vest's company, on healthy animals. Ten (10) equines were used in the project, male or female, adults, healthy, belonging to FMVZ-USP or private owners. Each animal went through two phases: A and B. Phase A consisted of the placement of the vest without turning on the vibrators, evaluating the animal's acceptability, facility, adaptation to the animal's body, and discomfort due to the vest's use. Phase B included the placement of the vest and turning on the vibrators, evaluating the animal's acceptability, reaction to the vibrators, and, if present, to which velocity/type of vibration, and the presence of adverse effects. Both phases were done three times on separate days. The behavioral parameters: "placement facility" and "adaptation to the animal's body" were observed. In phase B, the response to the vibration was classified from 0 to 5. The answer was evaluated on low and high intensities for the four vibration types. The heart rate (HR) and respiratory rate (RR) were also evaluated at the beginning and end of each repetition. The animals' HR was kept on normal, except for one animal on one day of the test. Concerning the RR, most animals presented moments of tachypnea. On the experiment's first day, 100% of grade Great to "facility of placement" and "adaptation to the animal's body" was obtained, but on days 2 and 3 this value dropped to 90% due to alterations in one animal's responses. Regarding vibration's responses, 77.3% were evaluated as no discomfort (grade 0), 17.1% little discomfort (grade 1), 3.3% medium discomfort (grade 2), 0.4% great discomfort (grade 3), 0.21% extreme discomfort (grade 4), and 1.6% non-acceptance of the vest (grade 5). Some possible changes on the prototype were also verified to be suggested to the manufacturer, such as the change of the buckle and the use of wireless control. Vest use appears promising for equine respiratory physiotherapy, considering the acceptability was good, and its efficiency on the expectoration of diseased animals must be tested.


O projeto consistiu no teste de um protótipo de colete de vibração torácica, adaptado aos equinos pela empresa do colete Expector®, em animais saudáveis. Foram utilizados 10 equinos, machos ou fêmeas, adultos, saudáveis, pertencentes à FMVZ-USP e a proprietários particulares. Cada animal passou por duas fases: A e B. A Fase A consistiu na colocação do colete sem ligar os vibradores, avaliando-se a aceitabilidade do animal; facilidade; adaptação ao corpo do animal e incômodo do mesmo à sua presença. Já a Fase B contava com a colocação do colete e funcionamento dos vibradores, avaliando-se a aceitabilidade do animal; reação aos vibradores e, se presente, a qual velocidade/tipo de vibração; presença de reações ou efeitos adversos. As duas fases foram realizadas em triplicata em dias separados. Foram observados os parâmetros comportamentais "facilidade de colocação" e "adaptação ao corpo do animal". Na fase B, a resposta à vibração foi classificada de 0 a 5. A resposta foi avaliada nas intensidades baixa e alta para os quatro diferentes tipos de vibração. Foram avaliadas também as frequências cardíaca (FC) e respiratória (FR) no início e final de cada repetição. A FC dos animais se manteve dentro do intervalo de normalidade, com exceção de um animal em um dia de avaliação. Em relação à FR, a maioria apresentou momentos de taquipneia. No primeiro dia de experimento obteve-se 100% de avaliação Ótima para "facilidade de colocação" e "adaptação ao corpo do animal", mas nos dias 2 e 3 esse valor caiu para 90% devido à alteração na resposta de um animal. Em relação à resposta à vibração, 77,3% das respostas foram avaliadas como nenhum incômodo (nota 0), 17,1% pouco incômodo (nota 1), 3,3% médio incômodo (nota 2), 0,4% muito incômodo (nota 3), 0,21% incômodo extremo (nota 4) e 1,6% não aceitação do colete (nota 5). Foram também verificadas algumas possíveis mudanças no protótipo a serem sugeridas ao fabricante, como mudança do tipo de fivela e uso de controle sem fio. A utilização do colete parece ser muito promissora para a fisioterapia respiratória em equinos, visto que a aceitabilidade foi muito boa, devendo-se agora realizar a avaliação de sua eficácia na expectoração de animais enfermos.(AU)


Assuntos
Animais , Adaptação Fisiológica , Modalidades de Fisioterapia/veterinária , Desenho de Equipamento , Taxa Respiratória/fisiologia , Frequência Cardíaca/fisiologia , Cavalos/fisiologia
5.
Acta cir. bras ; 36(7): e360708, 2021. graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1284914

Resumo

ABSTRACT Purpose To develop a specific device for pleural drainage in hypertensive pneumothorax. Methods The prototype was modeled from the free version of a 3D modeling application, printed on a 3D printer using ABS® plastic material, and tested in a pleural drainage simulator. Results Pleural drainage in the simulator using the prototype was feasible and reproducible. Conclusions While the prototype is functional in the simulator, it requires improvement and refinement for use in humans.


Assuntos
Humanos , Pneumotórax/cirurgia , Pleura , Drenagem
6.
Sci. agric. ; 78(4): 1-9, 2021. ilus, tab, mapas
Artigo em Inglês | VETINDEX | ID: vti-31350

Resumo

The method used to sample the runoff collected from soil erosion plots can be a significant source of error. In this study, we performed a laboratory experiment to evaluate the efficiency of the runoff sampling method most commonly used in Brazil. It is based on the manual homogenization and sampling of the collected runoff. Using soil material with 583 g kg-¹ of sand and 89 g kg-¹ of clay, the manual sampling method was tested for its ability to produce representative samples of artificial suspensions with a concentration of 2, 10 and 50 g L-¹ of total solids. An underestimation of 30 % or more of the concentration of total solids was observed, with a variation of the same magnitude (CV between 20 and 45 %). We then developed a prototype sample splitter to replace the manual sampling method and tested it using the same artificial suspensions. The splitter was efficient in producing samples representative of the artificial suspensions, even without altering the particle size distribution of the total solids. Both absolute percentage errors (|< 5 %|) and the variation between five replicates (CV < 3 %) were small. The problems with the manual method are due to the inefficient homogenization that facilitates the differential sedimentation of particles of different sizes. If these problems are also found in other areas, then the prototype that we developed is a reasonable alternative.(AU)


Assuntos
Monitoramento do Solo , Erosão do Solo/análise , Erosão do Solo/métodos
7.
Sci. agric ; 78(4): 1-9, 2021. ilus, tab, map
Artigo em Inglês | VETINDEX | ID: biblio-1497963

Resumo

The method used to sample the runoff collected from soil erosion plots can be a significant source of error. In this study, we performed a laboratory experiment to evaluate the efficiency of the runoff sampling method most commonly used in Brazil. It is based on the manual homogenization and sampling of the collected runoff. Using soil material with 583 g kg-¹ of sand and 89 g kg-¹ of clay, the manual sampling method was tested for its ability to produce representative samples of artificial suspensions with a concentration of 2, 10 and 50 g L-¹ of total solids. An underestimation of 30 % or more of the concentration of total solids was observed, with a variation of the same magnitude (CV between 20 and 45 %). We then developed a prototype sample splitter to replace the manual sampling method and tested it using the same artificial suspensions. The splitter was efficient in producing samples representative of the artificial suspensions, even without altering the particle size distribution of the total solids. Both absolute percentage errors (-< 5 %-) and the variation between five replicates (CV < 3 %) were small. The problems with the manual method are due to the inefficient homogenization that facilitates the differential sedimentation of particles of different sizes. If these problems are also found in other areas, then the prototype that we developed is a reasonable alternative.


Assuntos
Erosão do Solo/análise , Erosão do Solo/métodos , Monitoramento do Solo
8.
J. venom. anim. toxins incl. trop. dis ; 27: e20200073, 2021. tab, graf, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1154769

Resumo

he resistance against antimalarial drugs represents a global challenge in the fight and control of malaria. The Brazilian biodiversity can be an important tool for research and development of new medicinal products. In this context, toxinology is a multidisciplinary approach on the development of new drugs, including the isolation, purification, and evaluation of the pharmacological activities of natural toxins. The present study aimed to evaluate the cytotoxicity, as well as the antimalarial activity in silico and in vitro of four compounds isolated from Rhinella marina venom as potential oral drug prototypes. Methods: Four compounds were challenged against 35 target proteins from P. falciparum and screened to evaluate their physicochemical properties using docking assay in Brazilian Malaria Molecular Targets (BraMMT) software and in silico assay in OCTOPUS® software. The in vitro antimalarial activity of the compounds against the 3D7 Plasmodium falciparum clones were assessed using the SYBR Green I based assay (IC50). For the cytotoxic tests, the LD50 was determined in human pulmonary fibroblast cell line using the [3(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] (MTT) assay. Results: All compounds presented a ligand-receptor interaction with ten Plasmodium falciparum-related protein targets, as well as antimalarial activity against chloroquine resistant strain (IC50 = 3.44 µM to 19.11 µM). Three of them (dehydrobufotenine, marinobufagin, and bufalin) showed adequate conditions for oral drug prototypes, with satisfactory prediction of absorption, permeability, and absence of toxicity. In the cell viability assay, only dehydrobufotenin was selective for the parasite. Conclusions: Dehydrobufotenin revealed to be a potential oral drug prototype presenting adequate antimalarial activity and absence of cytotoxicity, therefore should be subjected to further studies.(AU)


Assuntos
Bufanolídeos/administração & dosagem , Bufonidae , Biodiversidade , Malária/imunologia , Antimaláricos , Técnicas In Vitro , Simulação por Computador
9.
J. Venom. Anim. Toxins incl. Trop. Dis. ; 27: e20200073, 2021. tab, graf, ilus
Artigo em Inglês | VETINDEX | ID: vti-31982

Resumo

he resistance against antimalarial drugs represents a global challenge in the fight and control of malaria. The Brazilian biodiversity can be an important tool for research and development of new medicinal products. In this context, toxinology is a multidisciplinary approach on the development of new drugs, including the isolation, purification, and evaluation of the pharmacological activities of natural toxins. The present study aimed to evaluate the cytotoxicity, as well as the antimalarial activity in silico and in vitro of four compounds isolated from Rhinella marina venom as potential oral drug prototypes. Methods: Four compounds were challenged against 35 target proteins from P. falciparum and screened to evaluate their physicochemical properties using docking assay in Brazilian Malaria Molecular Targets (BraMMT) software and in silico assay in OCTOPUS® software. The in vitro antimalarial activity of the compounds against the 3D7 Plasmodium falciparum clones were assessed using the SYBR Green I based assay (IC50). For the cytotoxic tests, the LD50 was determined in human pulmonary fibroblast cell line using the [3(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] (MTT) assay. Results: All compounds presented a ligand-receptor interaction with ten Plasmodium falciparum-related protein targets, as well as antimalarial activity against chloroquine resistant strain (IC50 = 3.44 µM to 19.11 µM). Three of them (dehydrobufotenine, marinobufagin, and bufalin) showed adequate conditions for oral drug prototypes, with satisfactory prediction of absorption, permeability, and absence of toxicity. In the cell viability assay, only dehydrobufotenin was selective for the parasite. Conclusions: Dehydrobufotenin revealed to be a potential oral drug prototype presenting adequate antimalarial activity and absence of cytotoxicity, therefore should be subjected to further studies.(AU)


Assuntos
Bufanolídeos/administração & dosagem , Bufonidae , Biodiversidade , Malária/imunologia , Antimaláricos , Técnicas In Vitro , Simulação por Computador
10.
Braz. J. Vet. Res. Anim. Sci. (Online) ; 58(n.esp): e173333, 2021. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1348204

Resumo

The donkey population has increased in the last 10 years, with an estimated 50 million donkeys currently worldwide. Donkey welfare, meanwhile, is an increasing global concern that receives close public scrutiny. However, multiple challenges are surrounding how donkey welfare is assessed and recorded. The Animal Welfare Indicators (AWIN) project is the first project, funded by the European Commission, intended to improve donkey welfare by developing a scientifically sound and practical on-farm welfare assessment protocol. The present study describes the procedure for the development of the AWIN welfare assessment protocol for donkeys: 1) selection of promising welfare indicators; 2) research to cover gaps in knowledge; 3) stakeholder consultation; 4) testing the prototype protocol on-farm. The proposed two-level strategy improved on-farm feasibility, while the AWIN donkey app enables the standardized collection of data with prompt results. Although limitations are linked with a relatively small reference population, the AWIN welfare assessment protocol represents the first scientific and standardized approach to evaluate donkey welfare on-farm.(AU)


Na última década, a população de jumentos vem aumentando; estima-se que existam aproximadamente 50 milhões de em todo o mundo. O bem-estar dos jumentos é uma preocupação global crescente, que recebe um escrutínio público próximo. No entanto, existem vários desafios em torno de como o bem-estar do jumento é avaliado e registrado. O projeto Indicadores de Bem-Estar Animal (AWIN) foi o primeiro projeto, financiado pela Comissão Europeia, destinado a melhorar o bem-estar dos jumentos, desenvolvendo um protocolo de avaliação do bem-estar cientificamente válido e prático na fazenda. O presente estudo descreve o procedimento para o desenvolvimento do protocolo de avaliação de bem-estar AWIN para jumentos: 1) seleção de indicadores promissores de bem-estar; 2) pesquisa para cobrir lacunas no conhecimento; 3) consulta às partes interessadas; 4) testando o protocolo do protótipo em fazendas. A estratégia proposta em dois níveis de avaliação melhorou a viabilidade na fazenda, além disso, o aplicativo AWIN donkey permite coletar dados de maneira padronizada e mostrar resultados rapidamente. Embora a limitação esteja ligada a uma população de referência relativamente pequena, o protocolo de avaliação de bem-estar do AWIN representa a primeira abordagem científica e padronizada para avaliar o bem-estar de jumentos em fazendas.(AU)


Assuntos
Animais , Bem-Estar do Animal , Equidae/crescimento & desenvolvimento
11.
Braz. j. vet. res. anim. sci ; 58(n.esp): e173333, 2021. ilus
Artigo em Inglês | VETINDEX | ID: vti-764848

Resumo

The donkey population has increased in the last 10 years, with an estimated 50 million donkeys currently worldwide. Donkey welfare, meanwhile, is an increasing global concern that receives close public scrutiny. However, multiple challenges are surrounding how donkey welfare is assessed and recorded. The Animal Welfare Indicators (AWIN) project is the first project, funded by the European Commission, intended to improve donkey welfare by developing a scientifically sound and practical on-farm welfare assessment protocol. The present study describes the procedure for the development of the AWIN welfare assessment protocol for donkeys: 1) selection of promising welfare indicators; 2) research to cover gaps in knowledge; 3) stakeholder consultation; 4) testing the prototype protocol on-farm. The proposed two-level strategy improved on-farm feasibility, while the AWIN donkey app enables the standardized collection of data with prompt results. Although limitations are linked with a relatively small reference population, the AWIN welfare assessment protocol represents the first scientific and standardized approach to evaluate donkey welfare on-farm.(AU)


Na última década, a população de jumentos vem aumentando; estima-se que existam aproximadamente 50 milhões de em todo o mundo. O bem-estar dos jumentos é uma preocupação global crescente, que recebe um escrutínio público próximo. No entanto, existem vários desafios em torno de como o bem-estar do jumento é avaliado e registrado. O projeto Indicadores de Bem-Estar Animal (AWIN) foi o primeiro projeto, financiado pela Comissão Europeia, destinado a melhorar o bem-estar dos jumentos, desenvolvendo um protocolo de avaliação do bem-estar cientificamente válido e prático na fazenda. O presente estudo descreve o procedimento para o desenvolvimento do protocolo de avaliação de bem-estar AWIN para jumentos: 1) seleção de indicadores promissores de bem-estar; 2) pesquisa para cobrir lacunas no conhecimento; 3) consulta às partes interessadas; 4) testando o protocolo do protótipo em fazendas. A estratégia proposta em dois níveis de avaliação melhorou a viabilidade na fazenda, além disso, o aplicativo AWIN donkey permite coletar dados de maneira padronizada e mostrar resultados rapidamente. Embora a limitação esteja ligada a uma população de referência relativamente pequena, o protocolo de avaliação de bem-estar do AWIN representa a primeira abordagem científica e padronizada para avaliar o bem-estar de jumentos em fazendas.(AU)


Assuntos
Animais , Bem-Estar do Animal , Equidae/crescimento & desenvolvimento
12.
Acta Vet. bras. ; 14(2): 61-67, jun. 2020. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-26339

Resumo

One of the motives that compromises the welfare of dogs is a lack of understanding of their needs and of the natural behavior of the species. The use of telemetry as a means of indirect observation is emergent and has provided a significant increase in scientific perspectives. However, its use is still limited for domestic animals despite the high potential for applying the technology in this area. Thus, the objective of this project was to construct a prototype using telemetry via satellite, of reduced size and low cost that allows for the monitoring of dogs in the streets. The prototype of the tracker was constructed containing a Pro Mini Arduino with an ATmega328 micro-controller, a GPS module for the Arduino, GPS u-blox NEO-6M and a Micro Sd reading/taping module for the Arduino. The final weight of the prototype was 197.4±101.5 grams with the battery and is attached to the collar. The dispersion of the planimetric coordinates around the mean was 2.7 meters, which increased to 10.9 meters when the height factor was added to the dispersion. It was concluded that with the size and weight of the prototype used it was possible to evaluate medium to large-sized dogs in the street. The prototype showed the precision necessary to read the coordinates collected for projects aimed at monitoring dogs in the streets, since these do not demand millimetric precision and accuracy.(AU)


Um dos motivos do comprometimento do bem-estar de cães é a falta de compreensão das suas necessidades e do comportamento natural da espécie. A utilização de telemetria como método de observação indireta é emergente e tem proporcionado um crescimento significativo das perspectivas científicas; porém, ainda em animais domésticos seu uso é limitado mesmo com seu alto potencial de aplicação da tecnologia no setor. Dessa forma a intenção do projeto foi a construção de um protótipo de telemetria via satélite de tamanho reduzido e de baixo custo que permita o monitoramento dos cães na rua. O protótipo de rastreador foi construído contendo um Arduino Pro Mini com o micro controlador ATmega328, um módulo GPS para Arduino, GPS u-blox NEO-6M e um módulo de leitor/gravador Micro Sd para Arduino. O peso final do protótipo chegou a 197,4±10,5 gramas com bateria e acoplado na coleira. A dispersão das coordenadas planimétricas ao redor da média foi de 2,7 metros e quando adicionado o fator altitude a dispersão passa para 10,9 metros. Conclui-se que com o tamanho e peso do protótipo utilizado é possível avaliar cães de rua de porte médio a grande. O protótipo teve uma precisão na leitura das coordenadas coletadas necessário para projetos de monitoramento de cães de rua nos quais não se exige uma precisão e acurácia milimétrica.(AU)


Assuntos
Animais , Cães , Programas de Rastreamento/métodos , Programas de Rastreamento/veterinária , Cães , Telemetria
13.
Acta Vet. Brasilica ; 14(2): 61-67, jun. 2020. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1453205

Resumo

One of the motives that compromises the welfare of dogs is a lack of understanding of their needs and of the natural behavior of the species. The use of telemetry as a means of indirect observation is emergent and has provided a significant increase in scientific perspectives. However, its use is still limited for domestic animals despite the high potential for applying the technology in this area. Thus, the objective of this project was to construct a prototype using telemetry via satellite, of reduced size and low cost that allows for the monitoring of dogs in the streets. The prototype of the tracker was constructed containing a Pro Mini Arduino with an ATmega328 micro-controller, a GPS module for the Arduino, GPS u-blox NEO-6M and a Micro Sd reading/taping module for the Arduino. The final weight of the prototype was 197.4±101.5 grams with the battery and is attached to the collar. The dispersion of the planimetric coordinates around the mean was 2.7 meters, which increased to 10.9 meters when the height factor was added to the dispersion. It was concluded that with the size and weight of the prototype used it was possible to evaluate medium to large-sized dogs in the street. The prototype showed the precision necessary to read the coordinates collected for projects aimed at monitoring dogs in the streets, since these do not demand millimetric precision and accuracy.


Um dos motivos do comprometimento do bem-estar de cães é a falta de compreensão das suas necessidades e do comportamento natural da espécie. A utilização de telemetria como método de observação indireta é emergente e tem proporcionado um crescimento significativo das perspectivas científicas; porém, ainda em animais domésticos seu uso é limitado mesmo com seu alto potencial de aplicação da tecnologia no setor. Dessa forma a intenção do projeto foi a construção de um protótipo de telemetria via satélite de tamanho reduzido e de baixo custo que permita o monitoramento dos cães na rua. O protótipo de rastreador foi construído contendo um Arduino Pro Mini com o micro controlador ATmega328, um módulo GPS para Arduino, GPS u-blox NEO-6M e um módulo de leitor/gravador Micro Sd para Arduino. O peso final do protótipo chegou a 197,4±10,5 gramas com bateria e acoplado na coleira. A dispersão das coordenadas planimétricas ao redor da média foi de 2,7 metros e quando adicionado o fator altitude a dispersão passa para 10,9 metros. Conclui-se que com o tamanho e peso do protótipo utilizado é possível avaliar cães de rua de porte médio a grande. O protótipo teve uma precisão na leitura das coordenadas coletadas necessário para projetos de monitoramento de cães de rua nos quais não se exige uma precisão e acurácia milimétrica.


Assuntos
Animais , Cães , Cães , Programas de Rastreamento/métodos , Programas de Rastreamento/veterinária , Telemetria
14.
Pesqui. vet. bras ; 40(7)2020.
Artigo em Inglês | VETINDEX | ID: vti-759415

Resumo

ABSTRACT: Several surgical procedures aim to decompress and/or stabilize the lumbosacral (LS) joint of dogs; however, the lumbar interbody fusion technique, by using a cage combined with a bone graft, is the most indicated and used in human medicine. No specific implant is available for application to the canine lumbosacral joint. Thus, this study measured lumbosacral discs in large dogs, determined whether a human cage model could fit the dogs L7-S1 intervertebral space, and developed a LS cage prototype for dogs. Ten cadaveric lumbosacral spines from adult dog weighing 20-35kg were used. The dogs had died for reasons unrelated to this study. The vertebral body dimensions and the L7-S1 intervertebral space occupied by the intervertebral disc were measured by lateral and ventrodorsal radiographs and by computed tomography in the dorsal, sagittal, and transverse views. Measurements were also taken of the anatomical specimens in the sagittal and transverse planes. After measuring the intervertebral discs, the following mean measures were obtained for L7-S1 discs: height 12.23mm, dorsal thickness 3.3mm, central thickness 4mm, ventral thickness 5.5mm, and width 24.74mm. The human lumbar cage models from brands LDR, Baumer Orthopedics, Stryker, Synthes, and Vertebral Technologies, Inc. and cervical stabilization cages from the brands B-Braun and Stryker were evaluated and were found to be unsuitable for large dogs. Cervical human cages had measurements similar to those found in this study; however, due to their quadrangular shape, the possibility of being introduced surgically through the surgical accesses available for the articulation between L7-S1 in dogs without injuring the cauda equina or the L7 root is small. A cage model was then developed using 3D modelling software. It was designed for insertion via dorsal laminectomy in the lateral portions of the intervertebral space. To avoid cauda equina lesion, the implant model was developed to be placed laterally to the midline. The cage surface is serrated to prevent using the locking screw to fix it, thus avoiding further injury to nerve structures. The serrated surfaces are also designed to avoid cage migration and promote stability. The prototype allows graft placement in the surrounding intervertebral space, which is fundamental for fusion through integration between the cage and the endplates as well as for bone growth between and around the cage. It was also considered studies on humans showing that the lateral regions of the endplates support a more considerable load. Biomechanical and in vivo studies on the developed model are necessary to evaluate the actual degree of distraction, mobility and the long-term rate of fusion between L7 and S1 and its possible impact on the adjacent motor units, combined or not with dorsal fixation techniques.


RESUMO: Vários procedimentos cirúrgicos visam descomprimir e/ou estabilizar a articulação lombossacra (LS) de cães; no entanto, a técnica de fusão lombar, usando um cage intersomático combinado com um enxerto ósseo, é a mais indicada e utilizada na medicina humana. Não há implante específico disponível para aplicação na articulação lombossacra canina. Assim, neste estudo foi realizada a mensuração do espaço do disco intervertebral lombossacro de cães de raças grandes, para verificar se algum modelo de cage usado na medicina humana poderia ser usado no espaço intervertebral L7-S1 de cães. O segundo objetivo foi desenvolver um protótipo de cage lombossacro para cães. Foram utilizadas dez colunas lombossacras provenientes de cadáveres de cães adultos com peso entre 20 e 35kg. Os cães vieram a óbito por razões não relacionadas a este estudo. As dimensões do corpo vertebral e o espaço intervertebral L7-S1 ocupado pelo disco intervertebral foram medidos por radiografias laterais e ventrodorsais e por tomografia computadorizada nos cortes dorsal, sagital e transversal. Também foram realizadas mensurações das peças anatômicas nos planos sagital e transversal. Após a mensuração dos discos intervertebrais, foram obtidas as seguintes medidas médias dos discos L7-S1: altura 12,23mm, espessura dorsal 3,3mm, espessura central 4mm, espessura ventral 5,5mm e largura 24,74mm. Os modelos de cage lombar humano das marcas LDR, Baumer Orthopaedics, Stryker, Synthes e Vertebral Technologies, Inc. não possuíam dimensões adequadas para os cães. Cages de estabilização cervical das marcas B-Braun e Stryker também foram avaliados e apresentaram medidas semelhantes às encontradas neste estudo; no entanto, devido à sua forma quadrangular, a possibilidade de serem introduzidos cirurgicamente através das abordagens disponíveis para a articulação entre L7-S1 em cães sem lesionar a cauda equina ou a raiz L7 é pequena. Um modelo de cage foi então desenvolvido usando-se o software de modelagem 3D. Foi projetado para inserção via laminectomia dorsal nas porções laterais do espaço intervertebral. Para evitar a lesão da cauda equina, o modelo de implante foi desenvolvido para ser colocado lateralmente à linha média. A superfície do cage é serrilhada para evitar o uso do parafuso de travamento, evitando-se lesões adicionais às estruturas nervosas. As superfícies serrilhadas também foram projetadas para evitar a migração do cage e promover estabilidade. O protótipo permite a colocação do enxerto no espaço intervertebral circundante, fundamental para a fusão através da integração entre o cage e as placas vertebrais terminais, bem como para o crescimento ósseo entre e ao redor do implante. Também foram considerados estudos em seres humanos que mostraram que as regiões laterais das placas vertebrais terminais suportam uma carga maior. São necessários estudos biomecânicos e in vivo do modelo desenvolvido para avaliar o grau real de distração, mobilidade e a taxa de fusão a longo prazo entre L7 e S1 e seu possível impacto nas unidades motoras adjacentes, quando combinado ou não com técnicas de fixação dorsal.

15.
Pesqui. vet. bras ; 40(7): 546-553, July 2020. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1135656

Resumo

Several surgical procedures aim to decompress and/or stabilize the lumbosacral (LS) joint of dogs; however, the lumbar interbody fusion technique, by using a cage combined with a bone graft, is the most indicated and used in human medicine. No specific implant is available for application to the canine lumbosacral joint. Thus, this study measured lumbosacral discs in large dogs, determined whether a human cage model could fit the dogs' L7-S1 intervertebral space, and developed a LS cage prototype for dogs. Ten cadaveric lumbosacral spines from adult dog weighing 20-35kg were used. The dogs had died for reasons unrelated to this study. The vertebral body dimensions and the L7-S1 intervertebral space occupied by the intervertebral disc were measured by lateral and ventrodorsal radiographs and by computed tomography in the dorsal, sagittal, and transverse views. Measurements were also taken of the anatomical specimens in the sagittal and transverse planes. After measuring the intervertebral discs, the following mean measures were obtained for L7-S1 discs: height 12.23mm, dorsal thickness 3.3mm, central thickness 4mm, ventral thickness 5.5mm, and width 24.74mm. The human lumbar cage models from brands LDR, Baumer Orthopedics, Stryker, Synthes, and Vertebral Technologies, Inc. and cervical stabilization cages from the brands B-Braun and Stryker were evaluated and were found to be unsuitable for large dogs. Cervical human cages had measurements similar to those found in this study; however, due to their quadrangular shape, the possibility of being introduced surgically through the surgical accesses available for the articulation between L7-S1 in dogs without injuring the cauda equina or the L7 root is small. A cage model was then developed using 3D modelling software. It was designed for insertion via dorsal laminectomy in the lateral portions of the intervertebral space. To avoid cauda equina lesion, the implant model was developed to be placed laterally to the midline. The cage surface is serrated to prevent using the locking screw to fix it, thus avoiding further injury to nerve structures. The serrated surfaces are also designed to avoid cage migration and promote stability. The prototype allows graft placement in the surrounding intervertebral space, which is fundamental for fusion through integration between the cage and the endplates as well as for bone growth between and around the cage. It was also considered studies on humans showing that the lateral regions of the endplates support a more considerable load. Biomechanical and in vivo studies on the developed model are necessary to evaluate the actual degree of distraction, mobility and the long-term rate of fusion between L7 and S1 and its possible impact on the adjacent motor units, combined or not with dorsal fixation techniques.(AU)


Vários procedimentos cirúrgicos visam descomprimir e/ou estabilizar a articulação lombossacra (LS) de cães; no entanto, a técnica de fusão lombar, usando um cage intersomático combinado com um enxerto ósseo, é a mais indicada e utilizada na medicina humana. Não há implante específico disponível para aplicação na articulação lombossacra canina. Assim, neste estudo foi realizada a mensuração do espaço do disco intervertebral lombossacro de cães de raças grandes, para verificar se algum modelo de cage usado na medicina humana poderia ser usado no espaço intervertebral L7-S1 de cães. O segundo objetivo foi desenvolver um protótipo de cage lombossacro para cães. Foram utilizadas dez colunas lombossacras provenientes de cadáveres de cães adultos com peso entre 20 e 35kg. Os cães vieram a óbito por razões não relacionadas a este estudo. As dimensões do corpo vertebral e o espaço intervertebral L7-S1 ocupado pelo disco intervertebral foram medidos por radiografias laterais e ventrodorsais e por tomografia computadorizada nos cortes dorsal, sagital e transversal. Também foram realizadas mensurações das peças anatômicas nos planos sagital e transversal. Após a mensuração dos discos intervertebrais, foram obtidas as seguintes medidas médias dos discos L7-S1: altura 12,23mm, espessura dorsal 3,3mm, espessura central 4mm, espessura ventral 5,5mm e largura 24,74mm. Os modelos de cage lombar humano das marcas LDR, Baumer Orthopaedics, Stryker, Synthes e Vertebral Technologies, Inc. não possuíam dimensões adequadas para os cães. Cages de estabilização cervical das marcas B-Braun e Stryker também foram avaliados e apresentaram medidas semelhantes às encontradas neste estudo; no entanto, devido à sua forma quadrangular, a possibilidade de serem introduzidos cirurgicamente através das abordagens disponíveis para a articulação entre L7-S1 em cães sem lesionar a cauda equina ou a raiz L7 é pequena. Um modelo de cage foi então desenvolvido usando-se o software de modelagem 3D. Foi projetado para inserção via laminectomia dorsal nas porções laterais do espaço intervertebral. Para evitar a lesão da cauda equina, o modelo de implante foi desenvolvido para ser colocado lateralmente à linha média. A superfície do cage é serrilhada para evitar o uso do parafuso de travamento, evitando-se lesões adicionais às estruturas nervosas. As superfícies serrilhadas também foram projetadas para evitar a migração do cage e promover estabilidade. O protótipo permite a colocação do enxerto no espaço intervertebral circundante, fundamental para a fusão através da integração entre o cage e as placas vertebrais terminais, bem como para o crescimento ósseo entre e ao redor do implante. Também foram considerados estudos em seres humanos que mostraram que as regiões laterais das placas vertebrais terminais suportam uma carga maior. São necessários estudos biomecânicos e in vivo do modelo desenvolvido para avaliar o grau real de distração, mobilidade e a taxa de fusão a longo prazo entre L7 e S1 e seu possível impacto nas unidades motoras adjacentes, quando combinado ou não com técnicas de fixação dorsal.(AU)


Assuntos
Animais , Cães , Doenças do Cão/cirurgia , Degeneração do Disco Intervertebral/veterinária , Síndrome da Cauda Equina/reabilitação , Síndrome da Cauda Equina/veterinária , Região Lombossacral/cirurgia , Doença Crônica/veterinária
16.
Acta cir. bras. ; 34(1): e20190010000008, Feb. 14, 2019. ilus, graf
Artigo em Inglês | VETINDEX | ID: vti-18663

Resumo

Abstract Purpose: To create a question and answer tool on patents on EMHO. Methods: Was used the Thinking Design methodology divided into four phases: Discovery, Definition, Development and Delivery. Discovery Phase: Desk research was carried out in: SciELO, Pubmed, LILACS, Google and Google Scholar. Once the target audience was selected, the interviews were conducted. Definition Phase: the interviewees difficulties were mapped, on an Excel spreadsheet. Development Phase: a brainstorming was conducted with the public interviewed. Delivery Phase: the prototype, validation and final elaboration of the tool were made. Results: Discovery Phase: 10 inventors were identified and the interviews were carried out. Definition Phase: 80% of the interviewees determined lack of information as one of the problems. The main content was defined as: the patent process, from the beginning of the idea to the deposit (70%), search for precedence (40%) and informing partners (30%). Development Phase: with the brainstorming, the tool type was defined as an interactive site. Delivery Phase: a prototype with content framework and an interactive video was presented for validation. After approval, the interactive website was developed, which was made available to the public. Conclusion: A question and answer tool on patents in EMHO was developed.(AU)

17.
Zoologia (Curitiba, Impr.) ; 36: e25662, Apr. 18, 2019. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1504554

Resumo

Vocalizations are often useful for understanding taxonomic relationships among anuran species. Despite this usefulness, vocalizations are described in only nine of 29 in Melanophryniscus Gallardo, 1961. Here we describe the advertisement call of Melanophryniscus xanthostomus Baldo, Bornschein, Pie, Ribeiro, Firkowski & Morato, 2015 of a population from Serra Dona Francisca, municipality of Campo Alegre, state of Santa Catarina, Brazil. The advertisement call (of three males, total of 17 calls) comprises two segments (the first with short and single notes, followed by a multi-pulsed note), with a duration of 12.194-20.986 s, and dominant frequency of 3101-3618 Hz (first and second segments combined). The advertisement call of M. xanthostomus differs from its congeners mostly by the higher number of pulses in the second segment (294-1033; from 16 to 321 in the other Melanophryniscus species), except Melanophryniscus krauczuki Baldo & Basso, 2004 (1018-1502 pulses in the second segment). This is the first described call of a phytotelm breeding Melanophryniscus, but it presents the same prototype (a compound call formed by two segments, the first composed of short notes followed by a long trill) of its congeners not-phytotelm breedings. This might indicate the advertisement call of Melanophryniscus as a conserved trait and thus can be considered diagnostic for the genus.


Assuntos
Animais , Acústica da Fala , Bufonidae/fisiologia , Vocalização Animal/classificação
18.
Zoologia (Curitiba) ; 36: e25662, Aug. 8, 2019. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-21721

Resumo

Vocalizations are often useful for understanding taxonomic relationships among anuran species. Despite this usefulness, vocalizations are described in only nine of 29 in Melanophryniscus Gallardo, 1961. Here we describe the advertisement call of Melanophryniscus xanthostomus Baldo, Bornschein, Pie, Ribeiro, Firkowski & Morato, 2015 of a population from Serra Dona Francisca, municipality of Campo Alegre, state of Santa Catarina, Brazil. The advertisement call (of three males, total of 17 calls) comprises two segments (the first with short and single notes, followed by a multi-pulsed note), with a duration of 12.194-20.986 s, and dominant frequency of 3101-3618 Hz (first and second segments combined). The advertisement call of M. xanthostomus differs from its congeners mostly by the higher number of pulses in the second segment (294-1033; from 16 to 321 in the other Melanophryniscus species), except Melanophryniscus krauczuki Baldo & Basso, 2004 (1018-1502 pulses in the second segment). This is the first described call of a phytotelm breeding Melanophryniscus, but it presents the same prototype (a compound call formed by two segments, the first composed of short notes followed by a long trill) of its congeners not-phytotelm breedings. This might indicate the advertisement call of Melanophryniscus as a conserved trait and thus can be considered diagnostic for the genus.(AU)


Assuntos
Animais , Bufonidae/fisiologia , Vocalização Animal/classificação , Acústica da Fala
19.
Ciênc. rural (Online) ; 49(12): e20180929, 2019. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1480153

Resumo

Rapid prototyping (RP) is an innovative technology that allows one to obtain a prototype of a mold quickly and accurately from a virtual model. This study aimed to establish the use of photogrammetry and 3D prototyping for the production of bone biomodels of the canine species for training in orthopedic techniques in veterinary medicine. Virtual bio-modelling was performed by the photogrammetry technique with commercial anatomical pieces, and physical biomodelling was performed by 3D printing. Osteotomies were performed on the biomodels that served as platforms for osteosynthesis of the femur and ileum, and the final product was not associated with a risk of biological contamination, was able to support special orthopedic materials, and was used for training and surgical planning. We concluded that the use of photogrammetry and RP for the production of bone biomodels of the canine species enabled techniques for fracture reduction to be performed with the use of special instruments, enabling training in the area of veterinary orthopedics in an economically viable manner with an alternative ­to experimental animals.


A prototipagem rápida (PR) é uma tecnologia inovadora que permite obter o protótipo de um molde com rapidez e precisão a partir de um modelo virtual. Esse estudo objetivou estabelecer o uso da fotogrametria e prototipagem 3D para a produção de biomodelos de ossos da espécie canina, para treinamento em técnicas ortopédicas em Medicina Veterinária. Utilizou-se a biomodelagem virtual através da técnica de fotogrametria de peças anatômicas comerciais e a biomodelagem física através de impressão 3D. Foram realizadas osteotomias nos biomodelos, que serviram para realização de osteossínteses de fêmur e íleo, sendo que o produto final não ofereceu risco de contaminação biológica, foi resistente para suportar matérias especiais ortopédicos, servindo para o treinamento e planejamento cirúrgico. Concluímos que a utilização da fotogrametria e PR para a produção de biomodelos de ossos da espécie canina, permitiu a execução de técnicas para redução de fraturas e capacitação na utilização de instrumentais especiais, possibilitando treinamento na área de ortopedia veterinária de maneira economicamente viável e uma alternativa em substituição aos animais de experimentação.


Assuntos
Fotogrametria/veterinária , Impressão Tridimensional , Modelos Anatômicos , Moldes Cirúrgicos/veterinária
20.
Ci. Rural ; 49(12): e20180929, Nov. 25, 2019. ilus
Artigo em Inglês | VETINDEX | ID: vti-24763

Resumo

Rapid prototyping (RP) is an innovative technology that allows one to obtain a prototype of a mold quickly and accurately from a virtual model. This study aimed to establish the use of photogrammetry and 3D prototyping for the production of bone biomodels of the canine species for training in orthopedic techniques in veterinary medicine. Virtual bio-modelling was performed by the photogrammetry technique with commercial anatomical pieces, and physical biomodelling was performed by 3D printing. Osteotomies were performed on the biomodels that served as platforms for osteosynthesis of the femur and ileum, and the final product was not associated with a risk of biological contamination, was able to support special orthopedic materials, and was used for training and surgical planning. We concluded that the use of photogrammetry and RP for the production of bone biomodels of the canine species enabled techniques for fracture reduction to be performed with the use of special instruments, enabling training in the area of veterinary orthopedics in an economically viable manner with an alternative ­to experimental animals.(AU)


A prototipagem rápida (PR) é uma tecnologia inovadora que permite obter o protótipo de um molde com rapidez e precisão a partir de um modelo virtual. Esse estudo objetivou estabelecer o uso da fotogrametria e prototipagem 3D para a produção de biomodelos de ossos da espécie canina, para treinamento em técnicas ortopédicas em Medicina Veterinária. Utilizou-se a biomodelagem virtual através da técnica de fotogrametria de peças anatômicas comerciais e a biomodelagem física através de impressão 3D. Foram realizadas osteotomias nos biomodelos, que serviram para realização de osteossínteses de fêmur e íleo, sendo que o produto final não ofereceu risco de contaminação biológica, foi resistente para suportar matérias especiais ortopédicos, servindo para o treinamento e planejamento cirúrgico. Concluímos que a utilização da fotogrametria e PR para a produção de biomodelos de ossos da espécie canina, permitiu a execução de técnicas para redução de fraturas e capacitação na utilização de instrumentais especiais, possibilitando treinamento na área de ortopedia veterinária de maneira economicamente viável e uma alternativa em substituição aos animais de experimentação.(AU)


Assuntos
Modelos Anatômicos , Impressão Tridimensional , Moldes Cirúrgicos/veterinária , Fotogrametria/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA