Your browser doesn't support javascript.
loading
Comparações entre o consumo observado e predito pelos sistemas nutricionais NRC e BR-Corte em novilhas Nelore confinadas no sistema GrowSafe® / Comparisons between observed and predicted consumption by NRC and BR-Court nutritional systems in Nelore heifers confined in the Grow Safe® system / Comparaciones entre el consumo observado y predicado por los sistemas nutricionales NRC y BR-Corte en novillas Nelore confinadas en el sistema Grow Safe®
Ferreira, Aline Maria Soares; Cunha, Ana Carolina Rodrigues da; Paula, Jean Marcos Castro; Silva, Simone Pedro da; Faria, Carina Ubirajara de.
Afiliação
  • Ferreira, Aline Maria Soares; s.af
  • Cunha, Ana Carolina Rodrigues da; s.af
  • Paula, Jean Marcos Castro; s.af
  • Silva, Simone Pedro da; Universidade Federal de Uberlândia. Faculdade de Medicina Veterinária. Uberlândia. BR
  • Faria, Carina Ubirajara de; Universidade Federal de Uberlândia. Faculdade de Medicina Veterinária. Uberlândia. BR
Vet. zootec ; 25: 73-77, 2018. tab
Article em Pt | VETINDEX | ID: biblio-1503499
Biblioteca responsável: BR68.1
Localização: BR68.1
RESUMO
Objetivou-se encontrar qual equação dos sistemas nutricionais BR-Corte (2010 e 2016) e NRC (2000 e 2016) melhor prediz o consumo de matéria seca (CMS) em novilhas de corte da raça Nelore em confinamento em sistema eletrônico de alimentação GrowSafe. Foram utilizadas 25 novilhas da raça Nelore, com idade entre 22 e 25 meses e peso médio corporal inicial 318 Kg. Comparou-se o CMS observado aos preditos segundo os sistemas nutricionais. O CMS médio observado das novilhas foi de 7,46 Kg/dia. A ingestão de matéria seca predita pelo NRC 2000 foi superestimada em 9,78% e pelo BR-Corte 2010, em 5,5%, já NRC 2016 e Br-Corte 2016 subestimaram o consumo das novilhas em 18,9% e 7,1%, respectivamente. Concluiu-se que os modelos para predição do CMS para novilhas da raça Nelore propostos pelos sistemas BR-Corte são mais adequados que os modelos do NRC.
ABSTRACT
The objective of this study was to find which equation of nutrition systems, BR-Corte (2010 and 2016) or NRC (2000 and 2016), better predict the dry matter intake (DMI) in heifers confinedin the electronic feeding system GrowSafe. Nellore heifers, aged 22 to 25 months and with an initial body weight of 318 kg, were sampled. It was compared the observed DMI with those predicted according to nutritional systems. The mean DMI of the heifers was 7.46 kg/day. The estimated dry matter intake in NRC 2000 was overestimated by 9.78% and BR-Corte 2010, by 5.5%, while NRC 2016 and Br-Corte 2016 underestimated heifer consumption by 18.9% and 7.1%, respectively. It was concluded that the models for predicting DMI for Nellore heifers proposed by the BR-Corte systems are more suitable than the NRC models.
RESUMEN
En el presente trabajo se analizaron los resultados obtenidos por los sistemas nutricionales BR-Corte (2010 y 2016) y NRC (2000 y 2016), buscando encontrar el que mejor predice el consumo de materia seca (CMS) en novillas de corte de la raza Nelore en confinamiento en sistema electrónico de alimentación GrowSafe. Se utilizaron 25 novillas de la raza Nelore, con edades entre 22 y 25 meses y peso corporal inicial 318 Kg. Se comparó el CMS observado a los predichos según los sistemas nutricionales. El CMS medio observado de las novillas fue de 7,46 Kg/día. La ingesta de materia seca predicha por el NRC 2000 fueron superestimadas en 9,78% y por el BR-Corte 2010, en 5,5%, ya el NRC 2016 y el Br-Corte 2016 subestimaron el consumo de las novillas en 18,9% y 7,1%, respectivamente. Se concluyó que los modelos para predicción del CMS para novillas de la raza Nelore propuestos por los sistemas BR-Corte son más adecuados que los modelos del NRC.
Assuntos
Palavras-chave
Texto completo: 1 Base de dados: VETINDEX Idioma: Pt Revista: Vet. zootec Ano de publicação: 2018 Tipo de documento: Article / Congress and conference
Texto completo: 1 Base de dados: VETINDEX Idioma: Pt Revista: Vet. zootec Ano de publicação: 2018 Tipo de documento: Article / Congress and conference