Your browser doesn't support javascript.
loading
A realistic model for vasectomy reversal training using swine testicles
Santos, Deivid Ramos dos; Corrêa Junior, Wender de Jesus Pena; Bentes, Lívia Guerreiro de Barros; Lemos, Rafael Silva; Araújo, Victor Matheus Mendonça de; Andrade, Gabrielly Leite; Teixeira, Renan Kleber Costa; Pinto, Luís Otávio Amaral Duarte; Bacelar, Herick Pampolha Huet de.
Afiliação
  • Santos, Deivid Ramos dos; Universidade Estadual do Pará. Belém. BR
  • Corrêa Junior, Wender de Jesus Pena; Universidade Federal do Pará. Belém. BR
  • Bentes, Lívia Guerreiro de Barros; Universidade Estadual do Pará. Belém. BR
  • Lemos, Rafael Silva; Universidade Estadual do Pará. Belém. BR
  • Araújo, Victor Matheus Mendonça de; Universidade Estadual do Pará. Belém. BR
  • Andrade, Gabrielly Leite; Centro Universitário do Pará. Belém. BR
  • Teixeira, Renan Kleber Costa; Universidade Estadual do Pará. Belém. BR
  • Pinto, Luís Otávio Amaral Duarte; Universidade Estadual do Pará. Belém. BR
  • Bacelar, Herick Pampolha Huet de; Universidade Federal de São Paulo. São Paulo. BR
Acta cir. bras ; 38: e383023, 2023. ilus
Article em En | VETINDEX | ID: biblio-1505461
Biblioteca responsável: BR68.1
Localização: BR68.1
ABSTRACT

Purpose:

To evaluate the viability of the porcine vas deferens as a realistic microsurgical training model for vasectomy reversal

Methods:

The model uses swine testicles (vas deferent), which are usually discarded in large street markets since they are not part of Brazilian cuisine. The spermatic cord was carefully dissected, and the vas deferens were isolated, measuring 10 cm in length. A paper quadrilateral with 5 cm2 was built to delimit the surgical training field. The objective of the model is to simulate only the microsurgical step when the vas deferens are already isolated. The parameters analyzed were feasibility for reproducing the technique, patency before and after performing the vasovasostomy, cost of the model, ease of acquisition, ease of handling, execution time, and model reproducibility.

Results:

The simulator presented low cost. All models made were viable with a texture similar to human, with positive patency obtained in 100% of the procedures. The internal and external diameters of the vas deferens varied between 0.2-0.4 mm and 2-3 mm, respectively, with a mean length of 9 ± 1.2 cm. The total procedure time was 43.28 ± 3.22 minutes.

Conclusions:

The realistic model presented proved to be viable for carrying out vasectomy reversal training, due to its low cost, easy acquisition, and easy handling, and providing similar tissue characteristics to humans.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: VETINDEX Idioma: En Revista: Acta cir. bras Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: VETINDEX Idioma: En Revista: Acta cir. bras Ano de publicação: 2023 Tipo de documento: Article