Your browser doesn't support javascript.
loading
Methods to Evaluate the Eggshell Quality of Table Eggs
Montenegro, A. T; Garcia, E. A; Molino, A. B; Cruvinel, J. M; Ouros, C. C; Alves, K. S.
Afiliação
  • Montenegro, A. T; São Paulo State University. School of Veterinary Medicine and Animal Science. Animal Production Department. Botucatu. Brasil
  • Garcia, E. A; São Paulo State University. School of Veterinary Medicine and Animal Science. Animal Production Department. Botucatu. Brasil
  • Molino, A. B; São Paulo State University. School of Veterinary Medicine and Animal Science. Animal Production Department. Botucatu. Brasil
  • Cruvinel, J. M; São Paulo State University. School of Veterinary Medicine and Animal Science. Animal Production Department. Botucatu. Brasil
  • Ouros, C. C; São Paulo State University. School of Veterinary Medicine and Animal Science. Animal Production Department. Botucatu. Brasil
  • Alves, K. S; São Paulo State University. School of Veterinary Medicine and Animal Science. Animal Production Department. Botucatu. Brasil
R. bras. Ci. avíc. ; 21(3): eRBCA-2019-1046, 2019. ilus, tab
Article em En | VETINDEX | ID: vti-25891
Biblioteca responsável: BR68.1
Localização: BR68.1
ABSTRACT
The objectives of this study were to determine the most suitable probe diameter and egg position to perform the eggshell breaking strength test using a texturometer, as well as the most reliable parameter to estimate eggshell quality when no electronic devices are available. Eggshell quality (eggshell breaking strength, eggshell weight, eggshell percentage, eggshell thickness, shell weight per unit surface area) was evaluated as a function of texturometer probe diameter (2, 10, and 75mm), egg type (white and brown) and egg position (horizontal and vertical). In the experiment, 2520 eggs from 60-week-old commercial layers were separated by specific gravity measured by flotation method in saline solution (1.070 to 1.100 g/cm3 with intervals of 0.005 g/cm3).Data were submitted to analysis of variance in a completely randomized design, and means were compared by Tukeys test (p 0.05). Correlations between characteristics were calculated using the Pearsons method. The results showed that the most suitable probe diameter for the analysis of eggshell breaking strength was 75 mm, independently of egg positioning or type egg. White eggs should be positioned vertically in relation to the probe, whereas brown can be placed in any position. When it is not possible to evaluate eggshell quality using electronic devices, the measurement of shell weight per unit surface area is recommended.(AU)
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: VETINDEX Idioma: En Revista: R. bras. Ci. avíc. / Rev. bras. ciênc. avic Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: VETINDEX Idioma: En Revista: R. bras. Ci. avíc. / Rev. bras. ciênc. avic Ano de publicação: 2019 Tipo de documento: Article