Your browser doesn't support javascript.
loading
Biometria ocular e sua relação com tamanho corporal e da cabeça em cães da raça buldogue francês / Ocular biometry and its relationship with body size and head in French Bulldog dogs
Faleiro, Rayssa Dias; Balthazar, Daniel de Almeida; Bastos, Isabela Pessôa Barbieri; Kuner, Andrea; Prando, Francis Arthur Seco; Santos Filho, Mário dos; Pereira, Jorge da Silva.
Afiliação
  • Faleiro, Rayssa Dias; Dok Hospital Veterinário. Rio de Janeiro. BR
  • Balthazar, Daniel de Almeida; Universidade Federal Rural do Rio de Janeiro. Seropédica. BR
  • Bastos, Isabela Pessôa Barbieri; H & Diagnóstico. Rio de Janeiro. BR
  • Kuner, Andrea; Clínica Veterinária Radiovet. Rio de Janeiro. BR
  • Prando, Francis Arthur Seco; Universidade Federal Rural do Rio de Janeiro. Seropédica. BR
  • Santos Filho, Mário dos; Universidade Federal Rural do Rio de Janeiro. Seropédica. BR
  • Pereira, Jorge da Silva; Centro de Estudo, Pesquisa e Oftalmologia Veterinária. Rio de Janeiro. BR
Acta sci. vet. (Impr.) ; 49: Pub.1778-2021. ilus, tab
Article em Pt | VETINDEX | ID: biblio-1458417
Biblioteca responsável: BR68.1
Localização: BR68.1
ABSTRACT

Background:

Ocular biometrics is an easy to perform, safe, non-invasive and low-cost exam that provides immediate resultswith excellent definition. Brachycephalic dogs have a high risk of developing eye problems, and the early appearance isfrequent due to factors linked to anatomical conformation. The aim of the present study was to perform eye biometrics inFrench Bulldog dogs through ultrasound, correlating with body and head size.Materials, Methods &

Results:

Clinical examination, ophthalmic examination and ocular biometrics were performed usingB-mode ultrasonography, using a 10 megahertz frequency transducer in 30 French Bulldog dogs, aged 1-6 years old, maleand females from the Br Lord’s Staff kennel and the Radiovet - Rio de Janeiro veterinary clinic. A drop of anesthetic eyedrops containing 1% tetracaine hydrochloride and 0.1% phenylephrine hydrochloride was instilled and the direct contacttechnique was performed with the cornea with the help of sterile water-soluble lubricating acoustic gel between the transducerand the examined eye. These measurements were correlated with cephalic measurements (frontal-occipital distance, skullcircumference, distance between the zygomatic arches and frontal-nasal distance) and with body measurements (lengthof the dog from the cranial end of the sternum to the ischial tuberosity and height of the withers from the cranial angleof the scapula to the ground). No chemical restraint was necessary. Dogs were positioned seated or in sternal decubitus,with slight physical restraint. All measurements were performed by the same examiner. There was no significant difference between the parameters of male and female eye biometrics and there was no difference between the measurementsof the right and left eyes. The mean value of axial bulb length was 19.51 ± 0.58 mm, for the thickness of the lens, 6.71 ±0.66 mm, for depth of the anterior chamber, 2.36 ± 0.89 mm and for the depth of the vitreous chamber...
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: VETINDEX Idioma: Pt Revista: Acta sci. vet. (Impr.) / Acta sci. vet. (Online) Ano de publicação: 2021 Tipo de documento: Article / Project document

Texto completo: 1 Base de dados: VETINDEX Idioma: Pt Revista: Acta sci. vet. (Impr.) / Acta sci. vet. (Online) Ano de publicação: 2021 Tipo de documento: Article / Project document