Your browser doesn't support javascript.
loading
Validation of an enzyme-linked immunosorbent assay by using the Total Error Concept, the Accuracy Profiles and the Accuracy Index as alternatives to the traditional ICH approach / Validação de ensaio imunoenzimático utilizando-se o Conceito do Erro Total, os Perfis de Exatidão e o Índice de Exatidão como alternativa à abordagem clássica do ICH
Possas, Jorge Luiz dos Santos; Santos, Jarbas Emílio dos; Nascimento, Michele Cardoso do; Santos, Patrícia Alves dos; Anjos, Deivid Wanderson Couto dos; Britto, Eduardo de Bonis de; Almeida, Antônio Eugênio Castro Cardoso de; Moura, Wlamir Corrêa de.
Afiliação
  • Possas, Jorge Luiz dos Santos; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Laboratório de Vacinas Virais. Rio de Janeiro. Brasil
  • Santos, Jarbas Emílio dos; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Laboratório de Vacinas Virais. Rio de Janeiro. Brasil
  • Nascimento, Michele Cardoso do; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Laboratório de Vacinas Virais. Rio de Janeiro. Brasil
  • Santos, Patrícia Alves dos; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Laboratório de Vacinas Virais. Rio de Janeiro. Brasil
  • Anjos, Deivid Wanderson Couto dos; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Laboratório de Vacinas Virais. Rio de Janeiro. Brasil
  • Britto, Eduardo de Bonis de; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Laboratório de Vacinas Virais. Rio de Janeiro. Brasil
  • Almeida, Antônio Eugênio Castro Cardoso de; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Laboratório de Vacinas Virais. Rio de Janeiro. Brasil
  • Moura, Wlamir Corrêa de; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Laboratório de Vacinas Virais. Rio de Janeiro. Brasil
R. Inst. Adolfo Lutz ; 74(4): 320-336, 2015. tab, graf
Article em Pt | VETINDEX | ID: vti-338151
Biblioteca responsável: BR68.1
Localização: BR68.1
ABSTRACT
The use of Total Error Concept for validating analytical methods is an approach that incorporates the sum of the Trueness and the Precision. This method also uses the accuracy profiles based on the tolerance intervals for whether a calibration model will give the quality results and it enables to control the risk in accepting an inappropriate methodology. The Total Error Concept, the Accuracy Profiles and the Accuracy Index were applied in this study for validating an enzyme-linked immunosorbent assay (ELISA) to determine the residual contents of ovalbumin in vaccines. This study tested a pure vaccine sample and spiked with three different concentrations (low, medium and high). Also an approach was used for evaluating the calculations methods which would yield the most accurate results. The obtained results in the concentrations range tested with the chosen model were Trueness - ER% from 1.61 % to 12.15 %; intermediate precision - CV% from 6.91 % to 9.31 %; and the Total Error from 9.83 % to 19.07 %, which are in conformity with the international guides. This study showed that the method is reliable to evaluate the ovalbumin contents, and that the Total Error Concept approach has applicability for validating enzyme immunoassays.(AU)
RESUMO
O uso do conceito do Erro Total em validação de métodos analíticos é uma abordagem que incorpora a soma da veracidade e precisão. Este método utiliza ainda Perfis de Exatidão baseados em intervalos de tolerância para decidir se um modelo de calibração dará resultados de qualidade, e realiza o controle do risco de aceitar uma metodologia imprópria. Foram aplicados o Conceito do Erro Total, os perfis de Exatidão e o s Índice de Exatidão na validação de um ensaio imunoenzimático (ELISA) para determinar o teor residual de ovoalbumina em vacinas. Este estudo testou uma amostra pura e fortificada com três diferentes concentrações (baixa, média e alta). A abordagem foi usada também para avaliar o método de cálculos que renderia resultados mais exatos. Os resultados obtidos no intervalo de concentrações testado com o modelo de cálculos escolhido foram veracidade - ER% de 1,61 % a 12,15 %; precisão intermediária - CV% de 6,91 % a 9,31 % e o Erro Total de 9,83 % a 19,07 %, obtendo-se dados em conformidade com os guias internacionais. O estudo demonstrou que o método empregado é confiável para avaliar o teor de ovoalbumina, e que a abordagem do Conceito do Erro Total apresenta aplicabilidade na validação de ensaios imunoenzimáticos.(AU)
Assuntos
Palavras-chave
Texto completo: 1 Base de dados: VETINDEX Idioma: Pt Revista: R. Inst. Adolfo Lutz Ano de publicação: 2015 Tipo de documento: Article
Texto completo: 1 Base de dados: VETINDEX Idioma: Pt Revista: R. Inst. Adolfo Lutz Ano de publicação: 2015 Tipo de documento: Article