Comparison between tympanic and anal temperature with a clinical infrared ray thermometer in dogs / Comparação entre a temperatura timpânica e a temperatura anal usando um termômetro clínico de raio infravermelho em cães

Wiedemann, G. G. S; Scalon, M. C; Paludo, G; Silva, I. O; Boere, V.
Arq. bras. med. vet. zootec; 58(4): 503-505, ago. 2006. tab
Artigo em Inglês | VETINDEX | ID: vti-7012

Resumo

A clinical thermometer of infrared rays was used twice to record consecutively the temperature of the tympanic membrane in each ear and in the anus of 53 dogs. Temperatures did not differ significantly between organs, and were strongly correlated. The anal temperature measurement with an infrared thermometer in dogs is feasible and trustworthy, as well as the thermal checking of tympanic temperature.(AU)
Utilizou-se um termômetro clínico de emissão de raios infravermelhos para medir, duas vezes consecutivas, a temperatura da membrana timpânica de cada ouvido e duas vezes a temperatura no ânus de 53 cães. Não houve diferença entre as temperaturas quanto ao órgão estudado e a correlação entre as temperaturas foi alta. Em cães, a medida da temperatura anal com o termômetro clínico de emissão de raios infravermelhos é rápida e confiável tanto quanto a da temperatura timpânica.(AU)
Biblioteca responsável: BR68.1