Measurement o f glomerular filtration in dog using 51Cr-EDTA and 113mlnDTPA / Medida da filtração glomerular no cão pelo 51Cr-EDTA e 113mIn-DTPA

Maliska, Carmelindo; de Souza Maciel, Oduvaldo; Carlos Gonçalves Saraiva, José.
Braz. j. vet. res. anim. sci; 14(2): 231-238, 1977.
Artigo em Português | VETINDEX | ID: vti-727096

Resumo

The glomerular filtration rate (GFR) was measured in 15 normal dogs using 51Cr-EDTA and 113mIn-DTPA, by a single injection technique. The results of GFR measurements was 3,01 (S.D.±0,71) ml/min/kg body weight, and 70.44 (S.D.±19,60) ml/min/m2 surface area. Difference in GFR (means) between the measurement by 51Cr-EDTA and 113mln-DTPA and between the male and female group was not statistically significant (P 0,05).
Em 15 cães clinicamente normais foi medida a taxa de filtração glomerular (TFG) pela técnica de injeção única, com 51Cr-ETA e 113mln-DTPA. A média e desvio padrão das determinações da TFG forma de 3,01 ± 0,71 ml/min/kg de peso e de 70,44 ± 19,60 ml/min/m2 de área corporal. Não foi verificada significância estatística entre as médias das medidas pelo 51Cr-EDTA e oelo 113mIn-DTPA e entre as médias dos grupos segundo o sexo e peso.