Fluxometria eco-power-doppler da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758) / Eco-power-doppler arterial flow from the external ophthalmic artery in cats (Felis catus Linnaeus, 1758) / Flujometria por ultrasonido de la arteria oftálmica externa en gatos (felix catus linnaeus, 1758)

Gonçalves, G. F; Pippi, N. L; Leme, M. C; Custódio, A. P; Fachin, L; Lago, E; Silva, A. V; Pachaly, J. R.
Arq. ciênc. vet. zool. UNIPAR; 8(2): 117-124, jul.-dez. 2005. ilus, tab
Artigo em Português | VETINDEX | ID: vti-7767

Resumo

Os avanços tecnológicos dos meios diagnósticos beneficiam a Medicina Veterinária. Para que novas tecnologias sejam utilizadas, são necessárias informações sobre os padrões normais para cada tipo de exame, o que possibilita sua utilização na rotina e destinação, adequadamente, a cada paciente. A fluxometria ultra-sonográfica está começando a ser utilizada em Medicina Veterinária com finalidades e propósitos diversos. Para destiná-la a um fim específico, o presente trabalho teve por objetivo verificar a fluxometria ultra-sonográfica da artéria oftálmica externa em gatos. Para tanto, foram utilizados 20 gatos sem raça definida, 12 machos e 8 fêmeas, com massa corporal entre 2,0 e 4,0 kg, hígidos, provenientes da Sociedade de Amparo aos Animais de Umuarama PR. Os animais foram anestesiados pela associação de tiletamina e zolazepam, administrada por via intramuscular, na dose de 6,0 mg/kg. A fluxometria da artéria oftálmica externa foi obtida por meio do equipamento de ultra-sonografia Toshiba Powervision ATL-HDI 3500, dotado de eco-doppler, com transdutor setorial de 6,0 MHz, aplicado diretamente sobre a córnea. Cada olho teve o fluxo de sua artéria aferido pelo programa do próprio aparelho, sendo tomadas três amostras. O índice de resistência vascular foi calculado com base nos valores do fluxo sistólico e diastólico médio de cada vaso. Os valores foram tabulados e teste t de Student foi aplicado para verificação de diferenças entre as médias. No olho direito, obteve-se velocidade de fluxo de 41,3 + ou - 14,28 cm/seg para a artéria oftálmica externa, em sístole, e 23,95 + ou - 11,46 cm/seg, em diástole. No olho esquerdo, 42,75 + ou - 12,64 cm/seg, em sístole, e 25,45 + ou - 9,61 cm/seg, em diástole. Não houve diferença significativa entre os olhos. O índice de resistência vascular calculado foi de 0,4175 para a artéria oftálmica externa, no olho direito, e 0,4015 no olho esquerdo, sem diferença significativa entre os olhos. Os resultados apontam para um mecani...(AU)
Veterinary medicine is benefi ted by technological advances in diagnosis. In order that new technologies may be used, information about normal standards for each type of examination is necessary, so that they may be used routinely and adequately prescribed for each patient. The Doppler ultrasound is beginning to be used in veterinary medicine for diverse purposes. The objective of this study is to verify the Doppler ultrasound fl ow of the external ophthalmic artery in cats. There were used 20 mixed breed cats, being 12 males and eight females, weighing from 2.0 to 4.0 kg, supplied by the Amparo aos Animais Society, an animal shelter from the city of Umuarama, State of Paraná, Brazil. The animals were anesthetized with 6.0 mg/kg of the association tiletamine plus zolazepam, given by intramuscular route. The fl ow of the external ophthalmic artery was measured through the ultrasound equipment Toshiba Powervision ATL-HDI 3500, with an echo-Doppler and a sectorial transducer of 6.0 MHz, directly applied to the cornea. Each eye had the artery fl ow surveyed by the equipments own software, in which three samples have been taken. The vascular resistance index was calculated based on the mean values of systolic and diastolic fl ow of each vessel. The values were tabulated and Student t test was applied to verify differences between the averages. In the right eye, the value for the external ophthalmic artery fl ow was 41.30 ± 14.28 cm/sec, in systole, and 23.95 ± 11.46 cm/seg, in diastole. For the left eye, the value was 42.75 ± 12.64 cm/sec, in systole, and 25.45 ± 9.61 cm/sec, in diastole. There were no signifi cant differences between the eyes. The calculated index of vascular resistance was 0.4175 ± 0.0774 for the external ophthalmic artery in the right eye, and 0.4015 ± 0.0719 for the left eye, without signifi cant difference between the eyes. (AU)
La medicina veterinaria se benefi cia de los adelantos tecnológicos en diagnóstico. El conocimiento de los padrones normales para cada tipo y examen es fundamental para que se puedan usar nuevas tecnologías, posibilitando su empleo rutinario y la indicación adecuada a cada paciente. El objetivo de este estudio fue verifi car la fl ujometría por ultrasonido de la arteria oftálmica externa en gatos. Se emplearon 20 gatos sin raza defi nida, 12 machos y ocho hembras, que provinieron de la Sociedad de Amparo a los Animales de la ciudad de Umuarama, Estado de Paraná, Brasil. Los animales fueron anestesiados con 6.0 mg/kg de la asociación de tiletamina y zolazepam, ministrados por vía intramuscular. El fl ujo de la arteria oftálmica externa fue mensurado por medio del equipo del ultrasonido Toshiba Powervision ATL-HDI 3500, con un eco-doppler y un transductor sectorial de 6.0 MHz, directamente aplicado a la córnea. Cada ojo tenía el fl ujo de la arteria evaluado por el propio programa del equipo, tomándose tres muestras. El índice de resistencia vascular se calculó basado en los valores promedios de fl ujo sistólico y diastólico de cada vaso. Los valores fueron tabulados y se aplicó el teste t de Student para verifi car diferencias entre los promedios. En el ojo derecho, el valor para el fl ujo de la arteria oftálmica externa fue 41,30 ± 14.28 cm/sec, en sístole, y 23,95 ± 11,46 cm/seg, en diástole. Para el ojo izquierdo, el valor fue 42,75 ± 12,64 cm/seg, en sístole, y 25,45 ± 9,61 cm/sec, en diastole. No se observó diferencia signifi cante entre los ojos. El índice calculado de resistencia vascular fue 0,4175 ± 0,0774 para la arteria oftálmica externa en el ojo derecho, y 0.4015 ± 0.0719 para el ojo izquierdo, sin diferencia signifi cante entre los ojos. Los resultados apuntan para un mecanismo intrínseco de control de fl ujo, controlado por factores locales en la arteria oftálmica externa, y los valores del índice de resistencia denotan una arteria de bajo flujo.(AU)