Your browser doesn't support javascript.

Portal de Pesquisa da BVS Veterinária

Informação e Conhecimento para a Saúde

Home > Pesquisa > ()
Imprimir Exportar

Formato de exportação:

Exportar

Exportar:

Email
Adicionar mais destinatários

Enviar resultado
| |

The normal electrocardiogram in the clinically healthy Saanen goats / Eletrocardiograma normal de cabras Saanen clinicamente sadias

Pogliani, Fabio C; Birgel Junior, Eduardo H; Monteiro, Bruno M; Grisi Filho, José H. H; Raimondo, Raquel F. S.
Pesqui. vet. bras; 33(12): 1478-1482, Dec. 2013. tab
Artigo em Inglês | VETINDEX | ID: vti-9993

Resumo

The purpose of this study was to establish normal reference electrocardiographic (ECG) values for standard limb lead II in Saanen goats. For this, were used 19 healthy adult female Saanen goats. And for reference values for the ECG parameters, were used 95% confidence level. The overall P, Q, R, S and T durations (seconds) were 0.03±0.01, 0.02±0.005, 0.03±0.014, 0.03±0.011, 0.06±0.014 respectively, and the reference values were 0.01-0.04, 0.01-0.02, 0.01-0.06, 0.02-0.04 and 0.04-0.08 respectively. The amplitudes (milivolts) of these waveforms were 0.1±0.031, 0.06±0.023, 0.44±0.312, 0.39±0.434, 0.26±0.164 (T negative) and 0.15±0.071 (T positive), respectively. The reference values were 0.05-0.15, 0.05-0.1, 0.05-1.2, 0.05-1.1 and -0.2-0.7 respectively. The PR and QT interval, the QRS complex and the ST segment durations (seconds) were 0.08±0.018, 0.26±0.03, 0.05±0.008, 0.15±0.041 respectively. The reference values were 0.06-0.12, 0.2-0.32, 0.04-0.07 and 0.11-0.26, respectively. It was possible to observe differences in ECG of Saanen goats regarding the amplitude and duration of the constituents when compared to the results of other breeds. Therefore it is necessary to conduct further studies to allow comparisons, detect and diagnose cardiac arrhythmias and help the development of therapies. (AU)
O objetivo deste estudo foi de estabelecer os valores de referência para o eletrocardiograma normal de derivação II de cabras Saanen sadias. As durações totais (segundos) das amplitudes de P, Q, R, S e T foram 0.03±0.01, 0.02±0.005, 0.03±0.014, 0.03±0.011, 0.06±0.014, respectivamente, e os valores de referência foram 0.01-0.04, 0.01-0.02, 0.01-0.06, 0.02-0.04 e 0.04-0.08, respectivamente. As amplitudes (milivolts) dessas formas de onda foram 0.1±0.031, 0.06±0.023, 0.44±0.312, 0.39±0.434, 0.26±0.164 (T negativo) e 0.15±0.071 (T positivo), respectivamente. Os valores de referência foram 0.05-0.15, 0.05-0.1, 0.05-1.2, 0.05-1.1 e -0.2-0.7, respectivamente. As durações (segundos) dos intervalos PR e QT, do complexo QRS e do segmento ST foram 0.08±0.018, 0.26±0.03, 0.05±0.008, 0.15±0.041, respectivamente. Os valores de referência foram 0.06-0.12, 0.2-0.32, 0.04-0.07, e 0.11-0.26, respectivamente. Foi possível observar diferenças em relação à duração e amplitude dos constituintes do ECG quando comparados com os resultados de outras raças. Portanto, torna-se necessário a realização de mais estudos para se permitir comparações, detectar e diagnosticar arritmias cardíacas bem como auxiliar no desenvolvimento de terapias. (AU)
Biblioteca responsável: BR1.1
Localização: BR68.1