Your browser doesn't support javascript.
loading
MÉTODOS DE COLETA, AVALIAÇÃO E PRESERVAÇÃO DE SÊMEN DE PACAS (Cuniculus paca Linnaeus, 1766) (CUNICULIDAE) EM DOIS DIFERENTES DILUENTES
s.n; 12/03/2018.
Thesis em Pt | VETTESES | ID: vtt-217133
Biblioteca responsável: BR68.1
RESUMO
ALVES, Augusto Luiz Faino. Universidade Federal do Acre, Março de 2018. Métodos de coleta, avaliação e preservação de sêmen de pacas (Cuniculus paca Linnaeus,1766) (Cuniculidae) em dois diferentes diluentes. OrientadorVânia Maria França Ribeiro, Co-orientador Fernando de Andrade Souza. Botusemen special Ao todo, sete animais foram submetidos a dois métodos para recuperação espermática a eletroejaculação e a recuperação de espermatozoides diretamente da cauda do epidídimo por flutuação. Este ultimo, com diluição em dois meios ACP123 e Botusemen special®. O protocolo anestésico foi feito com acepromazina 1% (0,1 mg/kg/IM) e associação de quetamina (20mg/kg) e xilazina (1,5mg/kg). As amostras coletadas pelo método de eletroejaculação obtiveram volume médio de 0,43ml (±0,33DP), concentração média de 45,5x106 espermatozoides/ml (±42,44DP) motilidade de 33,33% (±32,14DP) e vigor médio de 2,6 (±1,15DP). As amostras obtidas diretamente da cauda do epidídimo tiveram volume médio de 1,5ml, concentração média de 197,1x106 espermatozoides/ml (±84,9DP), sendo as médias da motilidade e vigor do diluente ACP 123, 63,8% (±34,2DP) e 4,2 (±1,7DP) respectivamente. Por outro lado, as amostras diluídas em Botusemen Special® apresentaram motilidade média de 29,8% (±34,2DP) e vigor médio de 2,4 (±1,9DP). A integridade de membrana dos espermatozoides quando diluídos com ACP 123 foi conservada em 84% (±0,07DP) e a viabilidade de membrana mantida em 53,9% (±3,78DP), enquanto o diluente Botusemen special® manteve 73% (±0,21DP) das células espermáticas integras e 39% (±17,9DP) de membranas viáveis. Os resultados foram comparados pelo teste de Wilcoxon-Mann-Whitney e descritos por médias e desvio padrão. Conclui-se, portanto que, a coleta epididimária obteve melhores resultados com relação aos parâmetros espermáticos em comparação ao protocolo de eletroejaculação. As avaliações dos diferentes diluidores indicaram que o diluente ACP-123 proporcionou melhor viabilidade espermática em comparação com o diluente comercial Botusemen special®, porém, ambos os compostos não conservaram as amostras espermáticas até o tempo de 24h.
ABSTRACT
ALVES, Augusto Luiz Faino. Universidade Federal do Acre, March 2018. Methods of collection, evaluation and preservation of paca(Cuniculus paca Linnaeus,1766) (Cuniculidae) semen in two different diluents. Advisor Vânia Maria França Ribeiro,Co-advisor Fernando de Andrade Souza. The objective of this study was to evaluate the efficiency of two methods of collecting semen from bales and to evaluate two diluents (ACP 123 and Botusemen special®) in the conservation of spermatozoa of this species. In all, seven animals were submitted to two methods of sperm retrieval the electroejaculation and the recovery of the spermatozoa directly from the tail of the epididymis by flotation. The latter, with dilution in two media ACP 123 and Botusemen special®. The anesthetic protocol was performed with acepromazine 1% (0.1mg/kg/IM) and combination of ketamine (20mg/kg) and xylazine (1.5 mg/kg). The samples collected by the electroejaculation method obtained an average volume of 0.43ml (±0.33DP), mean concentration of 45.5x106 spermatozoa/ml (±4.44DP), motility of 33.33% (±32.14DP) and mean vigor of 2.6 (±1.15DP). Samples obtained directly from the tail of the epididymis had a mean volume of 1.5ml, mean concentration of 197.1x106 spermatozoa/ml (±84.9DP). The mean motility and vigor of the ACP 123 diluent, 63.8% (±34.2DP) and 4.2 (±1.7DP), respectively. On the other hand, the samples diluted in Botusemen Special® presented mean motility of 29.8% (±34.2DP) and mean vigor of 2.4 (±1.9DP). Sperm membrane integrity when diluted with ACP 123 was conserved at 84% (±0.07DP) and membrane viability maintained at 53.9% (±3.78DP), while Botusemen special® Diluent maintained 73% (±0.21DP) of whole spermatozoa and 39% (±17.9DP) of viable membranes. The results were compared by the Wilcoxon-Mann-Whitney test and described by means and standard deviation. It was concluded, therefore, that the collection of the epididymis obtained better results in relation to the sperm parameters compared to the protocol of electro- ejaculation. The evaluations of the different diluents indicated that the ACP-123 diluent provided better sperm viability when compared to the commercial diluent Botusemen special®, however, both compounds did not retain the sperm samples for up to 24h.
Palavras-chave
Texto completo: 1 Base de dados: VETTESES Idioma: Pt Ano de publicação: 2018 Tipo de documento: Thesis
Texto completo: 1 Base de dados: VETTESES Idioma: Pt Ano de publicação: 2018 Tipo de documento: Thesis