Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cardiol Young ; 30(4): 482-488, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32070441

RESUMO

BACKGROUND: Balloon pulmonary valvuloplasty is the treatment of choice for patients with moderate to severe pulmonary valve stenosis. METHODS: An observational retrospective cross-sectional study including neonates, small infants, and children who underwent balloon pulmonary valvuloplasty in the period from 2007 to 2016 in the cardiac catheterisation unit of the paediatric cardiology department in Cairo University. Multivariable models were built to report the predictors of the outcome of balloon pulmonary valvuloplasty and its complications. RESULTS: A total of 1200 patients were included in the study and divided according to age into 3 groups: neonates and early infants (n = 282), infants (n = 362), and children (n = 556). Procedural success, defined as a drop pressure gradient across the pulmonary valve to less than or equal to 50% of the baseline measurements, was achieved in 82.7% of the patients. Multivariate analysis revealed that only infundibular pulmonary stenosis (p value 0.032), supravalvular in association with valvular pulmonary stenosis (p value <0.001), and pulmonary valve diameter by angiogram (p value <0.001) were significant predictors of success. The presence of supravalvular in association with valvular pulmonary stenosis (p value <0.001) was associated with a lower weight (p value 0.007) and higher right ventricular pressure before the intervention (p value <0.001), and a minor immediate drop in the pressure gradient post-intervention (p value <0.001) was found to be the most significant predictor of the occurrence of complications. CONCLUSION: The absence of infundibular and supravalvular stenosis and a large pulmonary valve diameter were the most significant predictors of success.


Assuntos
Valvuloplastia com Balão/métodos , Cateterismo Cardíaco/métodos , Previsões , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Pré-Escolar , Estudos Transversais , Ecocardiografia , Feminino , Seguimentos , Humanos , Lactente , Masculino , Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico , Estudos Retrospectivos , Resultado do Tratamento
2.
Appl Radiat Isot ; 166: 109389, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32882652

RESUMO

Copper oxide nanoparticles (CuO NPs) are needed in various fields, especially in the biomedical field. CuO NPs was obtained from Aspergillus terreus filtrate. CuO NPs structure was confirmed by UV-Vis spectrophotometry, as well as Fourier transform infrared (FT-IR), X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). XRD offers the nanoparticles purity of CuO biosynthesis. CuO NPs are spherical when examined with TEM. The average size of CuO NPs from TEM was 15.75 ± 3.95 nm. New composite of P (AA-AN)-NPs CuO was synthesized by biotechnology and the induced γ-radiation. The distribution coefficient value (Kd) of 47Sc(III) as well as 47Ca(II) ions for the synthetic new composite was determined by batch technique. Radiochemical separation of 47Sc(III) from irradiated calcium target was studied using chromatographic column packed with the new composite material. The recovery yield of 78 ± 1.2% for 47Sc(III) was obtained using 1 M HCl. The quality control tests (chemical, radionuclide and radiochemical purities) of the eluted 47Sc confirmed that it's adequate for nuclear medicine applications.


Assuntos
Cobre/metabolismo , Nanopartículas Metálicas/química , Radioisótopos/isolamento & purificação , Escândio/isolamento & purificação , Aspergillus/metabolismo , Cobre/efeitos da radiação , Humanos , Nanopartículas Metálicas/efeitos da radiação , Nanopartículas Metálicas/ultraestrutura , Nanocompostos/química , Nanocompostos/efeitos da radiação , Nanocompostos/ultraestrutura , Medicina Nuclear , Tamanho da Partícula , Controle de Qualidade , Radioquímica , Radioisótopos/normas , Compostos Radiofarmacêuticos/isolamento & purificação , Compostos Radiofarmacêuticos/normas , Escândio/normas , Nanomedicina Teranóstica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA