1.
Phys Med ; 85: 1-7, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33940527

RESUMO

The persistent use of MLCs through VMAT and IMRT is causing additional wear and tear on these mechanical parts, leading to an increase in MLC interlocks, breakdowns and failures. This study investigates the effect of an MLC clean and service procedure on MLC performance and positional accuracy demonstrated through in-house service logbook reports, Varian MLC backlash test results, daily MLC position QC results and Varian TrueBeam trajectory log file data. A service and clean of each individual MLC leaf was carried out on 3 standard MLC and 2 high definition MLC (HDMLC) Varian TrueBeam linacs. In-house service logbook reports, Varian backlash test results, daily MLC picket fence QC results and beam hold data from patient delivery trajectory log files were analysed for up to 6 months pre and 2 years post the MLC service/clean to assess the impact on unplanned MLC maintenance work and MLC performance. The median (range) of hardware faults reduced from 12 (1-17) pre clean to 0 (0-1) and 4 (1-11) at 12 and 24 months respectively for all linacs with the exception of a HDMLC linac where faults increased from 4 pre-clean to 13 and 20 again at 12 and 24 months respectively. The reduction in faults in the alternative 4 linacs was consistent with the reduction in the number of MLCs reaching the 0.3 mm and the 0.4 mm backlash recommendations in the first 12 and 24 months following the service/clean. The increase in faults in the HDMLC linac was also consistent with the increase in MLCs reaching the 0.3 mm backlash recommendation in the first 12 and 24 months. The median (range) of MLCs reaching a daily picket fence QC position tolerance of 0.25 mm reduced from 14 (1-40) pre clean to 0 (0) at both 12 and 24 months post-clean. This demonstrates the improvement in MLC performance caused by the MLC service/clean but also reveals factors other than MLC position accuracy influence hardware faults. Additionally, the number of beam hold-offs determined from patient delivery trajectory log files were found to have no correlation with the MLC service/clean. The MLC service/clean improves MLC performance and MLC position accuracy, reducing reactive repair work for engineering and physics staff. The results were maintained for 1 year post the MLC service/clean, with a trend back towards pre-clean levels in the subsequent 12-24 months. This suggests this preventative maintenance work could be performed at a frequency of > 2 years. This period of reduced faults and improved performance is significant given the 10 year expected lifespan of a linac.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Manutenção , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
2.
IEEE Trans Biomed Eng ; 58(4): 861-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21138796

RESUMO

The earliest signs of cardiovascular disease occur in microcirculations. Changes to mechanical and structural properties of these small resistive vessels alter the impedance to flow, subsequent reflected waves, and consequently, flow waveform morphology. In this paper, we compare two frequency analysis techniques: 1) rootMUSIC and 2) the discrete wavelet transform (DWT) to extract features of flow velocity waveform morphology captured using Doppler ultrasound from the ophthalmic artery (OA) in 30 controls and 38 age and sex matched Type I diabetics. Conventional techniques for characterizing Doppler velocity waveforms, such as mean velocity, resistive index, and pulsatility index, revealed no significant differences between the groups. However, rootMUSIC and the DWT provided highly correlated results with the spectral content in bands 2-7 (30-0.8 Hz) significantly elevated in the diabetic group (p < 0.05). The spectral distinction between the groups may be attributable to manifestations of underlying pathophysiological processes in vascular impedance and consequent wave reflections, with bands 5 and 7 related to age. Spectral descriptors of OA blood velocity waveforms are better indicators of preclinical microvascular abnormalities in Type I diabetes than conventional measures. Although highly correlated DWT proved slightly more discriminatory than rootMUSIC and has the advantage of extending to subheart rate frequencies, which may be of interest.


Assuntos
Algoritmos , Diabetes Mellitus Tipo 1/diagnóstico por imagem , Angiopatias Diabéticas/diagnóstico por imagem , Angiopatias Diabéticas/fisiopatologia , Microvasos/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Análise de Ondaletas , Adulto , Velocidade do Fluxo Sanguíneo , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/fisiopatologia , Angiopatias Diabéticas/etiologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Microcirculação , Microvasos/fisiopatologia , Processamento de Sinais Assistido por Computador