1.
J Biomech Eng ; 142(12)2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32601705

RESUMO

Cementless straight stems show very good survival rates. However, the more distal force application of straight stems may lead to release-related proximal stress-shielding. Nevertheless, this technical brief had the objective of conducting a biomechanical in vitro analysis comparing short stems with established straight stems with respect to their primary torsional stability. Two cementless short hip stems and three cementless straight hip stems were implanted in n = 5 synthetic femora each. Torsional torques were applied into the hip stems at a continuous interval of ±7 Nm. Micromotions were measured by six inductive extensometers on four different measurement levels. At the proximal measuring point, significantly smaller relative micromotions of the CLS® prosthesis could be detected compared to all other stem models (p < 0.05). In all stem models, smallest relative micromotions were found at the metaphyseal/diaphyseal measuring point. Only at the measuring point of the distal tips of the straight stems, statistically significantly lower relative micromotion of the CLS® stem compared to the Trendhip® stem could be found (p < 0.01). All the investigated stems generally display a rather comparable anchoring pattern and an almost physiological force application. Since the comparatively long straight stems present an anchoring pattern nearly identical to that of the examined short stems, a shortening of the established straight stems could be taken into consideration. This would offer the advantage of minimally invasive surgery and bone-saving resection as well as preservation of cancellous bone in case a revision would become necessary.


Assuntos
Prótese de Quadril , Artroplastia de Quadril , Fenômenos Biomecânicos , Fêmur , Desenho de Prótese , Estresse Mecânico
2.
Arch Orthop Trauma Surg ; 140(2): 247-253, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31786645

RESUMO

INTRODUCTION: Stress shielding may lead to aseptic loosening which is a common reason for implant failure. An established method to identify implants with risk of implant failure caused by aseptic loosening is to measure early migration of the stem with the "Ein Bild Roentgen Analyse" femoral component analysis (EBRA-FCA). Therefore, the aim of this study was to measure the migration of a cementless short stem prosthesis via EBRA-FCA to predict the future performance. MATERIALS AND METHODS: A total collective of 71 patients were treated with a cementless short hip stem prosthesis. Indications for surgery were primary coxarthrosis, dysplasia coxarthrosis or femoral head necrosis. After surgery, the patients were followed-up immediately after 3, 6, 12, 24, 36, and 48 months and X-ray images for EBRA-FCA measurements were taken. Axial caudal migration as well as the varus/valgus tilting of the prosthesis was determined. Possible influencing factors like BMI, age, diagnosis, gender or Harris Hip Score (HHS) on the migration of the stem were assessed. RESULTS: HHS increased significantly direct postoperatively (p < 0.001). At the second follow-up the average caudal migration was 0.42 ± 0.52 mm (range: 0.00-2.85 mm) (p < 0.001). A total of 14 patients underwent a caudal migration greater than 1.5 mm until 48 months. The initial varus and valgus tilts within the first 3 months were significant (p < 0.001). No correlations between BMI, age, diagnosis, gender or HHS and the migration as well as the tilting of the cementless short hip stem prosthesis were found. CONCLUSIONS: Although initial axial caudal migration as well as tilting tendencies in varus or valgus position can be detected, there is no marked migration of the examined prosthesis after the first 48 months. Likewise, no aseptic early loosening was detected throughout the study period, which indicates good osseointegration of the short stem prosthesis.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur , Prótese de Quadril/efeitos adversos , Falha de Prótese , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Humanos , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Radiografia
3.
Int Orthop ; 43(9): 2031-2037, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30178069

RESUMO

PURPOSE: The purpose of this study was to check the concept of the cementless Metha® short hip stem in order to find out whether proximal physiological load transfer can be achieved. METHODS: Fourty-three patients were included. Epidemiological factors were established. The Harris Hip Score was determined and measurement of bone mass density as well as osteodensitometric and radiological measurements was carried out pre-operatively, post-operatively, and after six, 12, 24, and 36 months. RESULTS: Harris Hip Score improved from 55.9 ± 12.4 pre-operatively to 94.8 ± 8.2 after 36 months (p < 0.001). After initial reduction of bone density in zones 1 and 7 up to six months post-operatively, there was a steady approximation of bone density to the initial values (p < 0.05). CONCLUSION: The Metha® short hip stem shows good clinical results. Furthermore, there is an increase of bone density in the proximal zones 1 and 7 between six and 36 months serving as a sign of physiological load transfer.


Assuntos
Artroplastia de Quadril/métodos , Necrose da Cabeça do Fêmur/cirurgia , Fêmur/cirurgia , Prótese de Quadril , Osseointegração , Osteoartrite do Quadril/cirurgia , Absorciometria de Fóton , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Fenômenos Biomecânicos , Cimentos Ósseos , Densidade Óssea/fisiologia , Cimentação , Feminino , Fêmur/diagnóstico por imagem , Fêmur/fisiopatologia , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/fisiopatologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/fisiopatologia , Estudos Prospectivos , Desenho de Prótese
4.
Arch Orthop Trauma Surg ; 139(3): 405-410, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30506094

RESUMO

PURPOSE: The purpose of this study was to examine potential differences between patients under and over 60 years who underwent a total short hip stem arthroplasty in a 24-month follow-up in a clinical setting. METHODS: Sixty seven patients were included in this prospective study and divided in two groups. In the younger cohort 39 patients ≤ 59 years and in the older cohort 28 patients ≥ 60 years were included. Clinical and radiological examinations of the patients took place preoperatively, postoperatively and after 3, 6, 12 and 24 months. The Harris Hip Score (HHS) was raised as clinical examination. Changes of bone mass density (BMD), stress shielding, reactive lines, spot welds and sclerosing were examined as radiological analysis. RESULTS: The HHS improved from 53.6 ± 8.2 preoperative to 93.2 ± 9.6 in the younger cohort and for the older cohort from 57.6 ± 14.8 to 94.1 ± 7.6 after 24 months. BMD growth was detectable in regions of interest (ROI) 3 and 6 for both groups. Different results between the cohorts could only be detected in ROIs 4 and 5. The older cohort showed a loss of BMD of 5.95% in ROI 4 and 3.17% in ROI 5 after 24 months, whereas the younger cohort showed no loss of BMD in both ROIs. CONCLUSIONS: No significant differences or any influences of osseointegration and clinical outcome of the short hip stem for both groups were detectable. Lower losses (ROIs 1 and 2) and higher growths (ROIs 3, 4, 5) were discovered in younger patients and the HHS improved in both groups. Reasons for this result could be age, sex or the level of activity of the patients, but in both groups the short hip stem shows comparable results in clinical as well as in radiological examination. We conclude that the short hip stem seems to be an adequate treatment also for older patients.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Osseointegração/fisiologia , Adulto , Fatores Etários , Idoso , Densidade Óssea/fisiologia , Seguimentos , Quadril/diagnóstico por imagem , Quadril/cirurgia , Prótese de Quadril , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Cell Tissue Bank ; 17(3): 427-37, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27344440

RESUMO

Revision surgery of joint replacements is increasing and raises the demand for allograft bone since restoration of bone stock is crucial for longevity of implants. Proceedings of bone grafts influence the biological and mechanic properties differently. This study examines the effect of thermodisinfection on mechanic properties of cancellous bone. Bone cylinders from both femoral heads with length 45 mm were taken from twenty-three 6-8 months-old piglets, thermodisinfected at 82.5 °C according to bone bank guidelines and control remained native. The specimens were stored at -20 °C immediately and were put into 21 °C Ringer's solution for 3 h before testing. Shear and pressure modulus were tested since three point bending force was examined until destruction. Statistical analysis was done with non-parametric Wilcoxon, t test and SPSS since p < 0.05 was significant. Shear modulus was significantly reduced by thermodisinfection to 1.02 ± 0.31 GPa from 1.28 ± 0.68 GPa for unprocessed cancellous bone (p = 0.029) since thermodisinfection reduced pressure modulus not significantly from 6.30 ± 4.72 GPa for native specimens to 4.97 ± 2.23 GPa and maximum bending force was 270.03 ± 116.68 N for native and 228.80 ± 70.49 N for thermodisinfected cancellous bone. Shear and pressure modulus were reduced by thermodisinfection around 20 % and maximum bending force was impaired by about 15 % compared with native cancellous bone since only the reduction of shear modulus reached significance. The results suggest that thermodisinfection similarly affects different mechanic properties of cancellous bone and the reduction of mechanic properties should not relevantly impair clinical use of thermodisinfected cancellous bone.


Assuntos
Osso Esponjoso/fisiologia , Desinfecção/métodos , Temperatura , Animais , Fenômenos Biomecânicos , Estresse Mecânico , Sus scrofa , Torção Mecânica , Suporte de Carga
6.
Int Orthop ; 39(3): 449-54, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25256851

RESUMO

PURPOSE: The purpose of our study was to investigate the change of sports activities before and after medial unicompartmental knee arthroplasty (UKA) with the use of the Heidelberg Sports Activity Score (HAS). METHODS: The Heidelberg Sports Activity Score (HAS) as well as FFb-H-OA, Oxford-12-Score, Tegner, UCLA and ACS were carried out to assess sports activities in 157 patients with medial osteoarthritis of the knee joint before and after UKA. The newly developed HAS also records the important duration and the sporting activity. RESULTS: Patients practiced sports in a more deliberate manner after UKA. Hiking, cycling and swimming were the sports most increased after surgery. Patients ≤65 years of age were sportier than those >65 years. Men were sportier than women, but all became sportier postoperatively. Patients with a high body mass index (BMI) are less sporty at first, but then increase their sports activity after surgery. CONCLUSIONS: HAS is an effective and valid assessment scale for evaluating sports activities before and after knee replacement.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Recuperação de Função Fisiológica , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Período Pós-Operatório , Qualidade de Vida , Esportes , Inquéritos e Questionários
7.
BMC Musculoskelet Disord ; 12: 46, 2011 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-21320313

RESUMO

BACKGROUND: Closing-wedge high tibial osteotomy (HTO) is successful for the treatment of medial osteoarthritis with varus malalignment. Preoperative risk factors for HTO failure are still controversial. The aim of this study was to elucidate the outcome and assess the influence of risk factors on long term HTO survival. METHODS: 199 patients were retrospectively studied with a mean follow-up period of 9.6 years after HTO. HTO failure was defined as the need for conversion to TKA. Survival was analyzed with the Kaplan-Meier method. Knee function was evaluated by the Hospital for Special Surgery (HSS) score. HTO-associated complications were also assessed. Univariate, multivariate, and logistic regression analysis were performed to evaluate the influence of age, gender, BMI, preoperative Kellgren-Lawrence osteoarthritis grade, and varus angle on HTO failure. RESULTS: 39 complications were recorded. Thus far, 36 HTOs were converted to TKA. The survival of HTO was 84% after 9.6 years. Knee function was considered excellent or good in 64% of patients. A significant preoperative risk factor for HTO failure was osteoarthritis, Kellgren-Lawrence grade >2. CONCLUSION: HTO provides good clinical results in long-term follow-up. Preoperative osteoarthritis Kellgren-Lawrence grade >2 is a significant predictive risk factor for HTO failure. Results of HTO may be improved by careful patient selection. Complications associated with HTO should not be underestimated.


Assuntos
Osteoartrite do Joelho/cirurgia , Osteotomia/efeitos adversos , Osteotomia/métodos , Tíbia/cirurgia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Falha de Tratamento , Resultado do Tratamento
8.
Med Eng Phys ; 86: 122-127, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33261725

RESUMO

The continuous improvement of minimally invasive hip endoprostheses surgery comes with a change in geometries of surgery instruments like the broach handles. Consequently, depending on the handles' curvature this results in a deviation between handle and femoral axis. Therefore, this study aimed to prove the influence of different handles' curvatures on the preparation of implant site and acting forces and moments in this process. Five femoral models attached to different handles (double-curved, single-curved, straight) were locked in a drop-weight device with standardize implantation forces and moments and five strokes were measured for each possible combination. Distribution of force and moment components was dependent on the handle's curvature, where the lowest variation from the standard force values was by the straight one (av:15.2% ± 0.5%) and the strongest discrepancies were exhibit by the double-curved one (av:54.3% ± 0.1%.). Moment values have also shown this trend with the lowest variation (12.4%-23.3%) by the straight one and the highest discrepancies (56,6%-90.9%) by the double-curved one. Results show that unguided axial impact introduces unwanted transverse forces and moments into the femur. Therefore, broach handles should be modified accordingly so that minimally invasive surgery remains feasible but unwanted forces or moments can still be compensated.


Assuntos
Fêmur , Fenômenos Mecânicos , Fêmur/cirurgia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos
9.
J Orthop ; 21: 302-308, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32581456

RESUMO

INTRODUCTION: Good osteointegration of implants requires sufficient primary stability. Aim of this study was to examine the influence of screw fixation on the primary stability of press-fit cups. METHODS: Two press-fit acetabular cups were tested with regard to the influence and number of screws and their primary stability. RESULTS: For the relatively thin-walled Allofit®-S cup, an influence of the number of screws on the different forms of movement could be demonstrated. CONCLUSIONS: We see a clear influence of the cup wall thickness on the elastic deformability and accordingly on the primary stability of the examined cups.

10.
Med Eng Phys ; 67: 49-54, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30902521

RESUMO

BACKROUND: For preclinical statements about the anchoring behavior of prostheses, the primary stability of the prosthesis is of special importance. It was the aim of this study to examine and compare the relevant relative micromotions of three different acetabulum prostheses by introducing three-dimensional torques. METHODS: The cups were implanted under standard conditions into an anatomical artificial bone model. Three-dimensional torques were applied to the acetabular cups. Taking into account the resulting frictional moments of two different bearing couples, ceramic-on-ceramic and ceramic-on-polyethylene, the relative micromotions of the cups were recorded as maximum total micromotion, translational and rotational micromotion, and the primary stability values of the three cups were compared. RESULTS: Relative micromotion of all cup models was always significantly smaller with the CoC bearing couples than with the CoP bearing couples (p < 0.001). The rotational micromotion was always lower (p < 0.001) than the translational micromotion, and the rotational as well as the translational micromotions were each always lower than the maximum total micromotion (p < 0.001, p < 0.010). The thinnest-walled cup system always showed the largest relative micromotions. CONCLUSION: The results of our study can be interpreted as indicating that the low relative micromotions of all cups - irrespective of the use of CoC or CoP bearing couples - are within an acceptable range favoring secondary osseointegration of the implants. Furthermore, we were able to show that the cup wall thickness and the surface quality of the cup systems have an influence on the primary stability and the elastic deformability of the examined cup systems.


Assuntos
Acetábulo , Prótese de Quadril , Teste de Materiais/instrumentação , Fenômenos Mecânicos , Acetábulo/cirurgia , Fenômenos Biomecânicos , Desenho de Prótese , Rotação
11.
J Biomech ; 93: 132-139, 2019 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-31337495

RESUMO

Following surgical Achilles tendon reconstruction surgery, there is a distinct trend towards an early and faster rehabilitation protocol to avoid muscle atrophy. However, this procedure involves the risk of a higher complication rate. In order to reduce the occurrence of re-ruptures and pathological tendon extensions, a tendon reconstruction with the highest possible primary stability is desirable. Therefore, the aim of this study was to determine if augmentation using synthetic polyester tapes (QuadsTape™) could provide greater primary stability in case of different tendon suture techniques. 90 tendons of the superficial toe flexor of pigs were divided into 9 groups. The reconstruction method was combined using the factors suture technique (Kessler and Bunnell), augmentation (non-augmented and augmented with QuadsTape™) and defect type (end-to-end and 10 mm gap). The biomechanical measurements were performed on a material testing machine and consisted of a creep test, a cyclic test and a tear-off test. This study compared creep strain, ultimate load failure, maximum stress and stiffness. Irrespective of the type of defect involved, augmentation of the tendon sutures led to a significant increase of the maximum force (not augmented: 82.30 ±â€¯25.48 N, augmented: 135.73 ±â€¯30.69 N, p < 0.001) and the maximum stress (not augmented: 2.26 ±â€¯0.83 MPa, augmented: 4.13 ±â€¯1.79 MPa, p < 0.001). Furthermore, there was a non-significant increase in stiffness and no significant differences were observed with respect to creep strain. Augmentation of Achilles tendon reconstruction using QuadsTape™ increases composite strength and stiffness in the in vitro model, thus potentially contributing to the feasibility of early rehabilitation programs. Biological factors still need to be investigated in order to formulate appropriate indications.


Assuntos
Tendão do Calcâneo/cirurgia , Fenômenos Mecânicos , Procedimentos de Cirurgia Plástica/métodos , Técnicas de Sutura , Tendão do Calcâneo/lesões , Animais , Fenômenos Biomecânicos , Teste de Materiais , Poliésteres , Procedimentos de Cirurgia Plástica/efeitos adversos , Técnicas de Sutura/efeitos adversos , Suínos
12.
J Orthop Res ; 36(10): 2745-2753, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29744927

RESUMO

Aseptic loosening is the main reason for revision of total hip arthroplasty, and relative micromotions between cementless acetabular cups and bone play an important role regarding their comparatively high loosening rate. Therefore, the aim of the present study was to analyze the influence of resulting frictional torques on the primary stability of press-fit acetabular cups subjected to two different bearing partners. A cementless press-fit cup was implanted in bone-like foam. Primary stability of the cup was analyzed by determining spatial total, translational, and rotational interface micromotions by means of an eddy current sensor measuring system. Torque transmission into the cup was realized by three synchronous servomotors considering resultant friction torques based on constant friction for ceramic-on-ceramic (CoC: µ = 0.044; max. resultant torque: 1.5 Nm) and for ceramic-on-polyethylene (CoP: µ = 0.063; max. resultant torque: 1.9 Nm) bearing partners. Rotational micromotion of CoC was 8.99 ± 0.85 µm and of CoP 13.39 ± 1.43 µm. Translational micromotion of CoC was 29.93 ± 1.44 µm and of CoP 39.91 ± 2.25 µm. Maximum total relative micromotions were 37.10 ± 1.07 µm for CoC and 51.64 ± 2.18 µm for CoP. Micromotions resulting from CoC were statistically lower than those resulting from CoP (p < 0.05). The described 3D-measuring set-up offers a novel in vitro method of measuring primary stability of acetabular cups. We can therefore conclude, that primary stability of acetabular cup systems can be observed using either the lower friction curve (CoC) or the higher friction curve (CoP). In future studies different cup designs or cup fixation mechanisms may be tested and compared in vitro and assessed prior to implantation. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2745-2753, 2018.


Assuntos
Prótese de Quadril/estatística & dados numéricos , Fricção , Humanos , Técnicas In Vitro , Torque
13.
Clin Biomech (Bristol, Avon) ; 52: 49-56, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29360049

RESUMO

BACKGROUND: The resultant hip force causes a varus torque which must be compensated by a shear force couple depending on the stem alignment of the prosthesis. Since the prosthesis is substantially less flexible than the bone, the interior of the femur is stiffened over the entire prosthesis length. The present study thus aims at analyzing short-stem prostheses for its elastic bending characteristics, considering inappropriate valgus alignment of the prosthetic stem. METHODS: Five short stem prostheses were implanted each in synthetic femora in a standardized manner - in neutral and valgus stem alignments. Bending movements were recorded applying a tilting torque MX of ±3.5 Nm in medio-lateral direction. Variance analyses and Friedman tests were used. A P-value <.05 was considered statistically significant. FINDINGS: Bending movements b1-b6 showed significant differences (P < .05). It could be shown that different stem alignments (P < .05) and different measuring points had a highly significant influence (P < .001) on the relative movements. Compared to the AIDA®, the MiniHip™ as well as the Metha® stiffened the femur to a higher degree (P < .001). INTERPRETATION: Regarding the elastic bending behavior we see a relevant influence of the stems´ design. We conclude that the short-stem principle does not necessarily require the shortest possible prosthesis but rather a long and thin extending stem tip to optimize the lever ratios, ensuring a more physiological bending behavior of the femur. In addition, without sufficient anchoring of the prosthesis, the valgus stem alignment could favor tilting of the implant and should therefore be avoided.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril , Desenho de Prótese , Elasticidade , Fêmur , Humanos , Estresse Mecânico , Torque
14.
J Med Case Rep ; 8: 140, 2014 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-24884796

RESUMO

INTRODUCTION: Silicone injection is a common procedure in cosmetic surgery. Granuloma formation and migration are the most commonly observed complications. CASE PRESENTATION: We report an unusual case of avascular necrosis of the hip in a 41-year-old woman from Thailand presenting with hip pain. Subcutaneous nodules were observed in the clinical examination. A pelvic X-ray revealed necrosis of the right femoral head and histological analysis of the punctuated nodules showed a reaction of foreign body granulomas. During surgical treatment with a hip replacement solitary silicone cysts were removed. CONCLUSIONS: This case report emphasizes that orthopedic surgeons treating patients with necrosis of the hip joint in combination with palpable granulomas in the gluteal region have to be aware of silicone augmentation and its potential complications before planning a hip replacement.


Assuntos
Artroplastia de Quadril , Necrose da Cabeça do Fêmur/cirurgia , Granuloma de Corpo Estranho/patologia , Silicones/efeitos adversos , Adulto , Nádegas , Feminino , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/etiologia , Granuloma de Corpo Estranho/complicações , Humanos , Injeções , Radiografia , Tailândia