Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 102(4): 585-593, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37560823

RESUMO

BACKGROUND: Donor vessel injury is a potentially life-threatening complication of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). AIMS: Our goal was to examine the incidence, mechanisms, treatment, and outcomes of patients with donor vessel injury in a large multicenter CTO PCI registry. METHODS: We analyzed the baseline clinical and angiographic characteristics, and procedural outcomes of 12,349 CTO PCIs performed between 2012 and 2022 at 44 centers. RESULTS: The incidence of donor vessel injury was 0.35% (n = 43). The baseline clinical characteristics of patients with and without donor vessel injury were similar. Cases complicated by donor vessel injury were more complex with higher Japanese CTO score (2.9 ± 1.1 vs. 2.4 ± 1.3; p = 0.004) and lower procedural success rate (69.8% vs. 85.2%; p = 0.004). The retrograde approach was used more commonly in donor vessel injury cases (68.9% vs. 30.9%; p < 0.001). Most (53.5%) donor vessel injuries were guide catheter-induced, whereas 20.9% were due to donor vessel thrombosis. Of the 43 patients with donor vessel injury, 36 (83.7%) were treated with stenting and seven (16.3%) received a left ventricular assist device. The incidence of major adverse cardiovascular events (MACEs) was significantly higher in cases with donor vessel injury (23.3% vs. 2.0%; p < 0.001). Of the 43 patients with donor vessel injury, five patients (11.6%) experienced acute myocardial infarction and four patients (9.3%) died. CONCLUSIONS: Donor vessel injury, occurred in 0.35% of CTO PCIs performed by experienced operators, was mainly due to guide catheter-induced dissection or thrombosis and was associated with lower procedural success and higher MACE.

2.
Catheter Cardiovasc Interv ; 99(3): 906-914, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34569695

RESUMO

BACKGROUND: There is a paucity of real-world data regarding the temporal trends and outcomes of trans-septal transcatheter mitral valve replacement (TS-TMVR) in the United States (US). METHODS: We queried the Nationwide Readmissions Database (October 2015 to December 2018) for patients undergoing TS-TMVR procedures. We reported the temporal trends in the utilization, in-hospital outcomes and 30-day readmissions after TS-TMVR. The main study outcome was in-hospital mortality. RESULTS: There was an increase in the number of TS-TMVR procedures over time (48 in 2015 vs. 978 in 2018, Ptrend < 0.001), with a notable increase in the proportion of women (Ptrend  = 0.04) and the prevalence of diabetes (Ptrend  = 0.03). There was an increase in the number of centers performing TS-TMVR (21 in 2015 vs. 164 in 2018, Ptrend < 0.001). The overall in-hospital mortality was 7.2% with no change over time (6.3% in 2015 vs. to 5.2% in 2018, Ptrend  = 0.67). There was no change in the frequency of in-hospital complications after TS-TMVR; however, the median length of stay has decreased over time. The overall 30-day readmission rate was 17.8%, with no change during the study years. The most frequent cause for 30-day readmission after TS-TMVR was acute heart failure followed by bleeding and infection-related complications. Prior coagulopathy and small-sized hospitals were independently associated with higher in-hospital mortality and 30-day readmissions. CONCLUSION: This nationwide observational analysis of real-world data showed an increase in the number of TS-TMVR procedures over time, which is now performed at a greater number of centers. There was no change in the rate of in-hospital mortality, complications or 30-day readmissions; but a significant reduction in the length of hospital stay over time was noted. As the number of TS-TMVR continue to expand, these data provide a perspective on the early experience with this procedure.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Readmissão do Paciente , Resultado do Tratamento , Estados Unidos/epidemiologia
3.
Catheter Cardiovasc Interv ; 97(4): 691-698, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33400380

RESUMO

BACKGROUND: There is a paucity of data regarding the outcomes of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) among solid-organ transplant recipients. METHODS: Temporal trends in hospitalizations for aortic valve replacement among solid-organ transplant recipients were determined using the National Inpatient Sample database years 2012-2017. Propensity matching was conducted to compare admissions who underwent TAVR versus SAVR. The primary outcome was in-hospital mortality. RESULTS: The analysis included 1,730 hospitalizations for isolated AVR; 920 (53.2%) underwent TAVR and 810 (46.7%) underwent SAVR. TAVR was increasingly utilized for solid-organ transplant recipients (Ptrend = 0.01), while there was no change in the number of SAVR procedures (Ptrend = 0.20). The predictors of undergoing TAVR for solid-organ transplant recipients included older age, diabetes, and prior coronary artery bypass surgery, while TAVR was less likely utilized in small-sized hospitals. TAVR was associated with lower in-hospital mortality after matching (0.9 vs. 4.7%, odds ratio [OR] 0.19; 95% confidence interval [CI] 0.11-0.35, p < .001) and after multivariable adjustment (OR 0.07; 95% CI 0.03-0.21, p < .001). TAVR was associated with lower rate of acute kidney injury, acute stroke, postoperative bleeding, blood transfusion, vascular complications, discharge to nursing facilities, and shorter median length of hospital stay. There was no difference between both groups in the use of mechanical circulatory support, hemodialysis, arrhythmias, or pacemaker insertion. CONCLUSION: This contemporary observational nationwide analysis showed that TAVR is increasingly performed among solid-organ transplant recipients. Compared with SAVR, TAVR was associated with lower in-hospital mortality, complications, and shorter length of stay.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Transplante de Órgãos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Curr Cardiol Rep ; 22(7): 50, 2020 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-32500412

RESUMO

PURPOSE OF REVIEW: The goal of the paper is to highlight the importance of procedural planning and patient selection when using the MitraClip device in treating severe mitral regurgitation (MR). RECENT FINDINGS: Following the recent results of the COAPT trial and FDA approval for functional MR patients, the indications for mitral clip are continuing to expand. Because of this, mitral stenosis from mitral clip can become a problem if the appropriate patients are not selected. Proper valve imaging, utilizing 3D transesophageal echocardiography to identify the pathology, is important to prevent iatrogenic mitral stenosis. In the unfortunate event of severe mitral stenosis as a result of the MitraClip device, surgery is the only treatment.


Assuntos
Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Valva Mitral/diagnóstico por imagem , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca , Humanos , Insuficiência da Valva Mitral/terapia , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/terapia , Resultado do Tratamento
5.
Cardiovasc Revasc Med ; 61: 8-15, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37951758

RESUMO

INTRODUCTION AND AIM: The optimal composition and duration of antiplatelet therapy after complex percutaneous coronary intervention (PCI) remains unclear. We conducted a meta-analysis to compare 1-3 months of dual antiplatelet therapy (DAPT) followed by monotherapy vs. 12 months of DAPT. METHOD: MEDLINE/PubMed, EMBASE, and Cochrane Central Register of Controlled Trials were queried for studies comparing 1-3 months of DAPT followed by monotherapy vs. 12 months of DAPT in the outcomes of complex PCI from inception through January 2023. Outcomes of interest included major bleeding, all-cause mortality, cardiovascular mortality, myocardial infarction (MI), stent thrombosis, target vessel revascularization, and stroke. RESULTS: Compared to 12 months, 1-3 months of dual antiplatelet therapy had a weak association with less major bleeding (OR 0.67; 95 % CI, 0.44-1.00; p = 0.05; I2 = 28 %). There were no significant differences between the shorter and longer antiplatelet therapy in terms of all-cause mortality (OR 0.83; 95 % CI, 0.59-1.16; p = 0.21; I2 = 17 %), cardiovascular mortality (OR 0.87; 95 % CI, 0.53-0.42; p = 0.50; I2 = 0), MI (OR 0.97; 95 % CI, 0.69-1.35; p = 0.82; I2 = 32 %), stent thrombosis (OR 1.17, 95 % CI, 0.77-1.76; p = 0.38; I2 = 0 %), target vessel revascularization (OR 1.05, 95 % CI, 0.58-1.89; p = 0.82; I2 = 64 %), or stroke (OR 1.10, 95 % CI, 0.55-2.17; p = 0.37; I2 = 7 %);. CONCLUSION: Among patients undergoing complex PCI, DAPT for 1-3 months may be associated with less major bleeding but similar rates of cardiovascular events (death, MI, stroke, stent thrombosis, and revascularization) compared to DAPT for 12 months.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Trombose , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Stents Farmacológicos/efeitos adversos , Hemorragia/induzido quimicamente , Trombose/etiologia , Acidente Vascular Cerebral/etiologia , Quimioterapia Combinada , Resultado do Tratamento
6.
Am J Cardiovasc Drugs ; 24(1): 71-81, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37995040

RESUMO

INTRODUCTION: Cangrelor is a potent intravenous non-thienopyridine P2Y12 inhibitor. We conducted a network meta-analysis to study the efficacy and safety of cangrelor as compared with the oral P2Y12 inhibition, clopidogrel, or placebo in acute coronary syndromes. METHODS: This meta-analysis followed the Cochrane collaboration guidelines and the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) protocols. Outcomes of interest included all-cause mortality, myocardial infarction, stent thrombosis, target vessel revascularization, major bleeding, minor bleeding, and the need for blood transfusion. RESULTS: The analysis was comprised of 6 studies including 26,444 patients treated with cangrelor, clopidogrel, or placebo. There were no statistically significant differences in the incidence of all-cause mortality, myocardial infarction, stent thrombosis, target vessel revascularization, or major bleeding. Cangrelor was associated with a higher risk of minor bleeding than clopidogrel or placebo, with no difference in requiring blood transfusion. CONCLUSION: Cangrelor has comparable outcomes to clopidogrel in patients with acute coronary syndromes and can be used as a reliable alternative in this population.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Clopidogrel/uso terapêutico , Síndrome Coronariana Aguda/terapia , Inibidores da Agregação Plaquetária/efeitos adversos , Metanálise em Rede , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Monofosfato de Adenosina/efeitos adversos , Infarto do Miocárdio/tratamento farmacológico , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Hemorragia/tratamento farmacológico , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Trombose/tratamento farmacológico
7.
Am J Cardiol ; 220: 102-110, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432334

RESUMO

Proximal radial artery (PRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (DRA) access in the anatomical snuffbox preserves the RA but safety and potential detrimental effects on hand function are unknown. We aimed to assess hand function and complications after DRA and PRA. In this single-center trial, 300 patients were randomly allocated 1:1 to cardiac catheterization through DRA or PRA. The primary end point of change in hand function from baseline to 1 year was a composite of the Quick Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, hand grip test, and thumb-forefinger pinch test. The secondary end points included access feasibility and complications. Of 216 patients with 1-year completed follow-up, 112 were randomly allocated to DRA and 104 to PRA, with balanced demographics and procedural characteristics. Both groups had similar access site bleeding rates (DRA 0% vs PRA 1.4%, p = 0.25). Radial artery occlusion occurred in 1 PRA patient versus 2 in DRA. There was no significant difference in change of hand function, median (interquartile range) hand grip (DRA 0.7 [-3 to 4.5] vs PRA 1.3 [-2 to 4.3] kg, p = 0.57), pinch grip (DRA -0.1 [-1.1 to 1] vs PRA -0.3 [-1 to 0.7] kg, p = 0.66), and Quick DASH (DRA 0 [-6.6 to 2.3] vs PRA 0 [-4.6 to 2.9] points, p = 0.58). The composite of hand function was comparable between PRA and DRA. In conclusion, DRA is a safe strategy for cardiac catheterization, with a low complication rate. Compared with PRA, there is no increased risk of hand dysfunction or radial artery occlusion at 1 year.


Assuntos
Cateterismo Cardíaco , Artéria Radial , Humanos , Masculino , Feminino , Cateterismo Cardíaco/métodos , Pessoa de Meia-Idade , Idoso , Força da Mão/fisiologia , Seguimentos , Fatores de Tempo
8.
Proc (Bayl Univ Med Cent) ; 37(2): 218-226, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343489

RESUMO

Background: In March 2022, a COVID-19 outbreak disrupted the global supply of iodine contrast media (ICM). Healthcare systems implemented contrast-saving strategies to maintain their remaining ICM supplies. This study sought to determine the impact of contrast shortage on the incidence of contrast-associated acute kidney injury (CA-AKI). Methods: This was a retrospective study of 265 patients undergoing 278 percutaneous coronary interventions (PCI) during 4-month periods prior to (9/1/2021 to 12/31/2021) and during (5/1/2022 to 8/31/2022) contrast shortage at a single center. The primary endpoint was the incidence of CA-AKI between study periods. Results: A total of 148 and 130 PCIs were performed before and during contrast shortage, respectively. The incidence of CA-AKI significantly decreased from 11.5% to 4.6% during contrast shortage (P = 0.04). During the shortage, average contrast volume per PCI was significantly lower (123 ± 62 mL vs 88 ± 46 mL, P < 0.001), while coronary imaging was significantly higher (34.3% vs 50%, P = 0.009) compared to preshortage. All-cause mortality at discharge was comparable between study periods (2.8% vs 3.3%, respectively; P = 0.90). Conclusion: The scarcity of ICM for PCI procedures in this single-center experience was associated with a significant increase in the utilization of intravascular imaging and a significant reduction in CA-AKI.

9.
Proc (Bayl Univ Med Cent) ; 36(2): 213-215, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36876240

RESUMO

We report a patient with Ebstein's anomaly, on chronic milrinone therapy for right ventricular failure, who underwent palliative percutaneous closure of her atrial septal defect (ASD) due to recurring strokes. Repeated evaluation of right-sided pressures was performed prior to ASD closure to determine if our patient could tolerate the intervention. Definitive ASD closure was performed under fluoroscopic and transesophageal echocardiogram guidance.

10.
J Am Soc Echocardiogr ; 36(12): 1302-1314, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37507058

RESUMO

BACKGROUND: The role of echocardiography in deriving transvalvular mean gradients from transaortic velocities in aortic stenosis (AS) and in structural valve degeneration (SVD) is well established. However, reports following surgical aortic valve replacement, post-transcatheter aortic valve replacement (TAVR), and valve-in-valve-TAVR (ViV-TAVR) have cautioned against the use of echocardiography-derived mean gradients to assess normal functioning bioprosthesis due to discrepancy compared with invasive measures in a phenomenon called discordance. METHODS: In a multicenter study, intraprocedural echocardiographic and invasive mean gradients in AS, SVD, post-native TAVR, and post-ViV-TAVR were compared, when obtained concomitantly, and discharge echocardiographic gradients were recorded. Absolute discordance (intraprocedural echocardiographic - invasive mean gradient) and percent discordance (intraprocedural echocardiographic - invasive mean gradient/echocardiographic mean gradient) were calculated. Multivariable regression analysis was performed to determine variables independently associated with elevated postprocedure invasive gradients ≥20 mm Hg, absolute discordance >10 mm Hg, and discharge echocardiographic mean gradient ≥20 mm Hg. RESULTS: A total of 5,027 patients were included in the registry: 4,725 native TAVR and 302 ViV-TAVR. Intraprocedural concomitant echocardiographic and invasive mean gradients were obtained pre-TAVR in AS (n = 2,418), pre-ViV-TAVR in SVD (n = 101), in post-ViV-TAVR (n = 77), and in post-TAVR (n = 823). Echocardiographic and invasive mean gradients demonstrated strong correlation (r = 0.69) and agreement (bias, 0.11; 95% CI, -0.4-0.62) in AS, moderate correlation (r = 0.56) and agreement (bias, 1.08; 95% CI, -2.53 to 4.59) in SVD, moderate correlation (r = 0.61) and weak agreement (bias, 6.47; 95% CI, 5.08-7.85) post-ViV-TAVR, and weak correlation (r = 0.18) and agreement (bias, 3.41; 95% CI, 3.16-3.65) post-TAVR. Absolute discordance occurs primarily in ViV-TVR and is not explained by sinotubular junction size and increases with increasing echocardiographic mean gradient. Percent discordance in AS and SVD (1.3% and 4%, respectively) was lower compared with post-TAVR/ViV-TAVR (66.7% and 100%, respectively). Compared with self-expanding valves, balloon expanding valves were independently associated with elevated discharge echocardiographic but lower invasive mean gradient (odds ratio = 3.411, 95% CI, 1.482-7.852, P = .004; vs odds ratio = 0.308, 95% CI, 0.130-0.731, P = .008, respectively). CONCLUSIONS: Post-TAVR/ViV-TAVR, echocardiography is discordant from invasive mean gradients, and absolute discordance increases with increasing echocardiographic mean gradient and is not explained by sinotubular junction size. Percent discordance is significantly higher post-TAVR/ViV-TAVR than in AS and SVD. Post-TAVR/ViV-TAVR, poor correlation and wide limits of agreement suggest echocardiographic and invasive mean gradients may not be used interchangeably and a high residual echocardiographic mean gradient should be confirmed invasively before considering any additional procedure to "correct" the gradient. Transcatheter aortic valve replacement valve types have variable impact on echocardiographic and invasive mean gradients.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Ecocardiografia
11.
Am J Cardiovasc Dis ; 13(5): 291-299, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026111

RESUMO

INTRODUCTION: The first-generation Watchman 2.5 (W 2.5)TM presented several limitations, such as challenges in implantation within complex left atrial appendage (LAA) anatomies, higher incidence of peri-device leak, device recapture, and device-related thrombus (DRT). The newer generation Watchman FLX (W-FLX)TM was introduced with a modified design aiming to overcome these limitations. The purpose of this meta-analysis is to conduct a comparative assessment of the safety and efficacy of the W-FLX and 2.5 devices in clinical practice. METHOD: The meta-analysis was conducted according to the preferred reporting items for systematic review and meta-analysis protocols (PRISMA). Studies were located through a search strategy utilizing PubMed, Cochrane, Google scholar and MEDLINE from inception to March 2023, with a primary objective to compare the safety and efficacy of the W-FLX and W 2.5 devices. After applying the selection criteria, five studies were included in this analysis. RESULTS: The analysis included five studies comprising 54,727 patients. The W-FLX is associated with an increase in procedural success (OR 7.49 [95% CI 1.98-28.26, P = 0.02; I2 = 0%]), and a significant reduction in mortality (OR 0.52 [95% CI 0.51-0.54, P<0.01; I2 = 0%], major bleeding 0.57 [95% CI 0.51-0.64, P<0.01; I2 = 0%]), device embolism (OR 0.35 [95% CI 0.18-0.70, P = 0.02; I2 = 0%]), and pericardial effusion (OR 0.33 [95% CI 0.26-0.41, P<0.01; I2 = 0%]). The rates of DRT and stroke were similar between the two groups. CONCLUSION: Compared to the W 2.5, the W-FLX was associated with a higher procedural success rate and significantly reduced adverse outcomes including mortality, major bleeding, device embolization, and pericardial effusion.

12.
J Am Heart Assoc ; 12(21): e030774, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37889176

RESUMO

Background Proximal radial artery (pRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (dRA) access in the anatomical snuffbox preserves the radial artery, but safety and potential detrimental effects on hand function are unknown. Methods and Results In the DIPRA (Distal Versus Proximal Radial Artery Access for Cardiac Catheterization and Intervention) study, a single-center trial, 300 patients were randomized 1:1 to cardiac catheterization through dRA or pRA. The primary end point of change in hand function from baseline to 30 days was a composite of the QuickDASH (Quick Disabilities of the Arm, Shoulder and Hand) questionnaire, hand-grip test, and thumb forefinger pinch test. Secondary end points included access feasibility and complications; 254 of 300 patients completed follow-up at 30 days; of these, 128 were randomized to dRA and 126 to pRA with balanced demographic and procedural characteristics. Both groups had similar rates of access site bleeding (dRA 0% versus pRA 1.4%; P=0.25). Six patients with dRA failed access compared with 2 patients with pRA. Radial artery occlusion occurred in 2 pRA versus none in dRA. There were no significant differences in change in hand function, median hand-grip (dRA 0 [-3.2, 3.3] versus pRA 0.7 [-2.3, 3.3] kg; P=0.21), pinch-grip (dRA -0.3 [-1.2, 0.5] versus pRA 0 [-0.9, 0.9] kg; P=0.09), and QuickDASH (dRA 0 [-4.6, 2.3] versus pRA 0 [-4.6, 2.3] points, P=0.96). There was no significant difference in the composite of hand function between pRA and dRA. Conclusions dRA is a safe strategy for cardiac catheterization with a low complication rate. Compared with pRA, there is no increased risk of hand dysfunction at 30 days. Registration URL: https://www.ClinicalTrials.gov. Unique identifier: NCT04318990.


Assuntos
Arteriopatias Oclusivas , Intervenção Coronária Percutânea , Humanos , Artéria Radial , Punho , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
13.
JACC Cardiovasc Interv ; 16(24): 2999-3012, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-37902146

RESUMO

BACKGROUND: Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field have been obtained from retrospective studies. OBJECTIVES: The authors sought to compare the 1-year hemodynamic performance and clinical outcomes between balloon-expandable valves (BEV) SAPIEN 3/ULTRA (Edwards Lifesciences) and self-expanding valves (SEV) Evolut R/PRO/PRO+ (Medtronic) in ViV-TAVR. METHODS: Patients with a failed small (≤23 mm) surgical valve undergoing ViV-TAVR were randomized to receive a SEV or a BEV. Patients had a clinical and valve hemodynamic (Doppler echocardiography) evaluation at 1-year follow-up. Study outcomes were defined according to VARC-2/VARC-3 criteria. Intended performance of the valve was defined as mean gradient <20 mm Hg, peak velocity <3 m/s, Doppler velocity index ≥0.25 and less than moderate AR. RESULTS: A total of 98 patients underwent ViV-TAVR (46 BEV, 52 SEV). At 1-year follow-up, patients receiving a SEV had a lower mean transaortic gradient (22 ± 8 mm Hg BEV vs 14 ± 7 mm Hg SEV; P < 0.001), and a higher rate of intended valve performance (BEV: 30%, SEV:76%; P < 0.001). There were no cases of greater than mild aortic regurgitation. There were no differences in functional status (NYHA functional class >II, BEV: 7.3%, SEV: 4.1%; P = 0.505) or quality of life (Kansas City Cardiomyopathy Questionnaire, BEV: 77.9 ± 21.2, SEV: 81.8 ± 14.8; P = 0.334). No differences in all-cause mortality (BEV: 6.5%, SEV: 3.8; P = 0.495), heart failure hospitalization (BEV: 6.5%, SEV: 1.9%; P = 0.214), stroke (BEV: 0%, SEV: 1.9%; P = 0.369), myocardial infarction (BEV: 0%, SEV: 1.9%; P = 0.347), or pacemaker implantation (BEV: 2.2%, SEV: 1.9%; P = 0.898) were found. CONCLUSIONS: In patients who underwent ViV-TAVR for failed small aortic bioprostheses, those receiving a SEV exhibited a better valve hemodynamic profile at 1-year follow-up. There were no differences between SEV and BEV regarding functional status, quality of life, or clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Desenho de Prótese
14.
J Invasive Cardiol ; 35(7): E329-E340, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37769619

RESUMO

BACKGROUND: Although discouraged, ad hoc chronic total occlusion (CTO) percutaneous coronary intervention (PCI) is occasionally performed. METHODS: We examined the clinical, angiographic characteristics, and procedural outcomes of patients who underwent ad hoc CTO PCI in the Prospective Global Registry for the Study of CTO Intervention (PROGRESS-CTO, NCT02061436). RESULTS: Of the 10,998 patients included in the registry, 899 (8.2%) underwent ad hoc CTO PCI. The incidence of ad hoc CTO PCI decreased from 18% in 2016 to 3% in 2022. Ad hoc CTO PCI patients had a lower prevalence of comorbidities and less complex angiographic characteristics demonstrated by lower J-CTO score (1.9±1.2 vs 2.4±1.3, P < .001). In these patients, PROGRESS-CTO major adverse cardiovascular events (MACE) (1.9±1.4 vs 2.5±1.7), mortality (1.2±1.0 vs 1.6±1.1), and perforation (1.5±1.2±2.2 vs 1.5) scores were lower (P < .001). Technical success was similar between the groups (86%). MACE were lower in the ad hoc CTO PCI group (.8% vs 2.0%, P=.009). Ad hoc CTO PCI was not associated with MACE after adjusting for potential confounders, odds ratio: .69 (95% confidence interval, .30-1.57). In patients with higher J-CTO scores, planned CTO PCI was associated with higher technical success (P < .001). CONCLUSION: Approximately 8% of CTO PCI procedures are performed ad hoc, usually in less complex lesions and patients with lower complication risk. While ad hoc CTO PCI might be appropriate for carefully selected cases, a staged approach is recommended for most CTO PCI.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Resultado do Tratamento , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Angiografia Coronária/métodos , Sistema de Registros , Oclusão Coronária/diagnóstico , Oclusão Coronária/epidemiologia , Oclusão Coronária/cirurgia , Doença Crônica , Fatores de Risco
15.
Circ Cardiovasc Interv ; 16(6): e012977, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37259859

RESUMO

BACKGROUND: Death is a rare but devastating complication of chronic total occlusion (CTO) percutaneous coronary intervention. METHODS: We examined the clinical characteristics and procedural outcomes of patients who died periprocedurally in the Prospective Global Registry for the Study of CTO Interventions (PROGRESS-CTO). RESULTS: Of the 12 928 patients who underwent CTO percutaneous coronary intervention between 2012 and 2022, 52 (0.4%) died during the index hospitalization. Patients who died were more likely to have a history of heart failure (43% versus 28%; P=0.023). The J-CTO ([Multicenter CTO Registry of Japan]; 2.8±1.1 versus 2.4±1.3; P=0.019), PROGRESS-CTO mortality (2.6±0.9 versus 1.6±1.1; P<0.001), and PROGRESS-CTO pericardiocentesis (2.9±1.1 versus 1.9±1.3; P<0.001) scores were higher in patients who died. In these patients, the use of left ventricular assist devices was also higher (41% versus 3.5%; P<0.001), and retrograde crossing was more often the first crossing strategy (33% versus 13%; P<0.001). The cause of death was cardiac in 43 patients (83%) and noncardiac in 9 patients (17%). Complications leading to cardiac death were: tamponade in 30 patients (58%), acute myocardial infarction in 9 (17.3%), and cardiac arrest/shock in 4 (7.7%). Noncardiac causes of death were: stroke in 3 (5.8%), renal failure in 2 (3.8%), respiratory distress in 2 (3.8%), and hemorrhagic shock in 2 (3.8%). CONCLUSIONS: Approximately 0.4% of patients who underwent CTO percutaneous coronary intervention died during the index hospitalization. The main cause of death was tamponade in 58%. PROGRESS-CTO complication scores might help in risk stratification and procedural planning in patients undergoing CTO percutaneous coronary intervention. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique Identifier: NCT02061436.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/etiologia , Estudos Prospectivos , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Doença Crônica , Fatores de Risco , Angiografia Coronária
16.
Am J Cardiol ; 197: 55-64, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37156067

RESUMO

Chronic total occlusion (CTO) percutaneous coronary interventions (PCIs) can be lengthy procedures. We sought to investigate the effect of procedural time on CTO PCI outcomes. We examined the procedural time required for the various steps of CTO PCI in 6,442 CTO PCIs at 40 US and non-US centers between 2012 and 2022. The mean and median procedure times were 129 ± 76 and 112 minutes, respectively, with no significant change over time. The median times from access to wire insertion, guidewire manipulation time, and post crossing were 20, 32, and 53 minutes, respectively. Lesions crossed in <30 minutes were less complex, as reflected by lower Japanese CTO score (1.89 ± 1.19, p <0.001) than lesions that were not successfully crossed (2.88 ± 1.22) and lesions that were crossed in ≥30 minutes (2.85 ± 1.13). The likelihood of successful crossing if crossing was not achieved after 30, 90, and 180 minutes were a 76.7%, 60.7%, and 42.7%, respectively. The parameters independently associated with ≥30 minutes guidewire manipulation time in patients with a primary antegrade approach included left anterior descending target vessel, proximal cap ambiguity, blunt/no stump, occlusion length, previous failed attempt, medium/severe calcification, and medium/severe tortuosity. The mean duration of CTO PCI is approximately 2 hours (∼20% of time for access to wire insertion, ∼30% wire manipulation time, and ∼50% postwiring time). Guidewire crossing time was shorter in less complex lesions and in cases without complications.


Assuntos
Calcinose , Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Oclusão Coronária/diagnóstico , Oclusão Coronária/cirurgia , Fatores de Tempo , Doença Crônica , Angiografia Coronária/métodos , Sistema de Registros
17.
J Invasive Cardiol ; 35(9)2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37983108

RESUMO

BACKGROUND: There is limited information on the impact of the target vessel on the procedural techniques and outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: We analyzed the baseline clinical and angiographic characteristics and procedural outcomes of 11,580 CTO PCIs performed between 2012 and 2022 at 44 centers. RESULTS: The most common CTO target vessel was the right coronary artery (RCA) (53.1%) followed by the left anterior descending artery (LAD) (26.0%) and the left circumflex artery (LCX) (19.8%). RCA CTOs were longer and more complex, with a higher Japanese CTO score compared with LAD or LCX CTOs. Technical success was higher among LAD (88.8%) lesions when compared with RCA (85.7%) or LCX (85.8%) lesions (P less than .001). The incidence of major adverse cardiovascular events (MACE) was overall 1.9% (n = 220) and was similar among target vessels (P=.916). There was a tendency toward more frequent utilization of the retrograde approach for more proximal occlusions in all 3 target vessels. When compared with all other RCA lesions combined, distal RCA lesions had higher technical success (87.7% vs 85.3%; P=.048). Technical success was similar between various locations of LAD CTOs (P=.704). First/second/third obtuse marginal branch had lower technical success when compared with all other LCX lesion locations (82.7% vs 86.8%; P=.014). There was no association between MACE and CTO location in all 3 target vessels. CONCLUSIONS: LAD CTO PCIs had higher technical and procedural success rates among target vessels. The incidence of MACE was similar among target vessels and among various locations within the target vessel.


Assuntos
Intervenção Coronária Percutânea , Doenças Vasculares , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Angiografia
18.
Proc (Bayl Univ Med Cent) ; 35(4): 517-519, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35754592

RESUMO

We present a rare case of dobutamine-supported WATCHMAN FLX™ device deployment in a medically complex patient prone to recurrent left atrial appendage thrombus and spontaneous echo contrast formation due to underlying low-flow state.

19.
Proc (Bayl Univ Med Cent) ; 35(5): 700-702, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35991726

RESUMO

Balloon aortic valvuloplasty (BAV) has been increasingly used to medically optimize patients with severe aortic stenosis prior to surgical or transcatheter aortic valve replacement, as a bridge to palliative therapy, or as palliative therapy. BAV traditionally requires large vascular sheaths to allow for sizable valvuloplasty balloons. Herein, we report a case of a patient who received BAV as a bridge to gastric surgery to facilitate weight loss as a bridge to transcatheter aortic valve replacement. BAV was successfully completed via a biradial approach.

20.
JACC Cardiovasc Interv ; 15(18): 1837-1848, 2022 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-36137687

RESUMO

BACKGROUND: Low ejection fraction (EF) and low flow as determined by an echocardiographic stroke volume index (SVi) <35 mL/m2 are associated with low transvalvular gradients and increased mortality in both severe aortic stenosis (AS) and post-transcatheter aortic valve replacement (TAVR). Absence of an elevated echocardiographic transaortic gradient post-TAVR is considered a marker of procedural success despite the absence of data on its impact on mortality. OBJECTIVES: The authors sought to examine the association of invasive and echocardiographic gradients post-TAVR with all-cause mortality in relation to flow and EF. METHODS: In a multicenter retrospective registry of patients undergoing TAVR, Cox models with regression splines explored the relationship between invasive and echocardiographic gradients post-TAVR with 2-year mortality. An invasive gradient <5 mm Hg was considered low, between ≥5 and <10 mm Hg was considered intermediate, and ≥10 mm Hg was considered high. An echocardiographic gradient <10 mm Hg was considered low, ≥10 and <20 mm Hg was considered intermediate, and ≥20 mm Hg was considered high. RESULTS: Higher mortality occurred in low echocardiographic gradients at discharge relative to intermediate gradients (P < 0.001), and low gradient was associated with lower EF and echocardiographic SVi (P < 0.001 and P < 0.008, respectively). Lower mortality occurred in low invasive gradients relative to intermediate gradients (P = 0.012) with no difference in EF and echocardiographic SVi between groups (P = 0.089 and P = 0.947, respectively). There were insufficient observations to determine the impact of high echocardiographic and invasive gradients on mortality. CONCLUSIONS: In this large retrospective analysis, the impact of transaortic gradients on mortality after TAVR was not linear and complex, showing opposite results among echocardiographic and invasive measurements in low-gradient patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Humanos , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA