Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BMC Pulm Med ; 21(1): 133, 2021 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-33894747

RESUMO

BACKGROUND: Among the challenges for personalizing the management of mechanically ventilated patients with coronavirus disease (COVID-19)-associated acute respiratory distress syndrome (ARDS) are the effects of different positive end-expiratory pressure (PEEP) levels and body positions in regional lung mechanics. Right-left lung aeration asymmetry and poorly recruitable lungs with increased recruitability with alternating body position between supine and prone have been reported. However, real-time effects of changing body position and PEEP on regional overdistension and collapse, in individual patients, remain largely unknown and not timely monitored. The aim of this study was to individualize PEEP and body positioning in order to reduce the mechanisms of ventilator-induced lung injury: collapse and overdistension. METHODS: We here report a series of five consecutive mechanically ventilated patients with COVID-19-associated ARDS in which sixteen decremental PEEP titrations were performed in the first days of mechanical ventilation (8 titration pairs: supine position immediately followed by 30° targeted lateral position). The choice of lateral tilt was based on X-Ray. This targeted lateral position strategy was defined by selecting the less aerated lung to be positioned up and the more aerated lung to be positioned down. For each PEEP level, global and regional collapse and overdistension maps and percentages were measured by electrical impedance tomography. Additionally, we present the incidence of lateral asymmetry in a cohort of forty-four patients. RESULTS: The targeted lateral position strategy resulted in significantly smaller amounts of overdistension and collapse when compared with the supine one: less collapse along the PEEP titration was found within the left lung in targeted lateral (P = 0.014); and less overdistension along the PEEP titration was found within the right lung in targeted lateral (P = 0.005). Regarding collapse within the right lung and overdistension within the left lung: no differences were found for position. In the cohort of forty-four patients, ventilation inequality of > 65/35% was observed in 15% of cases. CONCLUSIONS: Targeted lateral positioning with bedside personalized PEEP provided a selective attenuation of overdistension and collapse in mechanically ventilated patients with COVID-19-associated ARDS and right-left lung aeration/ventilation asymmetry. TRIAL REGISTRATION: Trial registration number: NCT04460859.


Assuntos
COVID-19/terapia , Posicionamento do Paciente/métodos , Atelectasia Pulmonar/prevenção & controle , Síndrome do Desconforto Respiratório/terapia , Lesão Pulmonar Induzida por Ventilação Mecânica/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/métodos , Estudos Prospectivos , Atelectasia Pulmonar/terapia , Respiração Artificial/métodos , SARS-CoV-2
3.
Int J Cardiovasc Imaging ; 39(4): 853-862, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36565388

RESUMO

The study aimed to evaluate a quantification method of pulmonary perfusion with Dual-Energy CT Angiography (DE-CTA) normalized by lung density in the prediction of outcome in acute pulmonary embolism (PE). In this prospective study with CTA scans acquired with different breathing protocols, two perfusion parameters were calculated: %PBV (relative value of PBV, expressed per unit volume) and PBVm (PBV normalized by lung density, expressed per unit mass). DE-CTA parameters were correlated with simplified pulmonary embolism severity index (sPESI) and with outcome groups, alone and in combinationwith tomographic right-to-left ventricular ratios (RV/LV). PBVm showed significant correlation with sPESI. PBVm presented higher accuracy than %PBV In the prediction of ICU admission or death in patients with PE, with the best performance when combined with RV/LV volumetric ratio.


Assuntos
Angiografia por Tomografia Computadorizada , Embolia Pulmonar , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Prospectivos , Valor Preditivo dos Testes , Embolia Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Perfusão
4.
Front Physiol ; 14: 1113568, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37020459

RESUMO

Low-volume lung injury encompasses local concentration of stresses in the vicinity of collapsed regions in heterogeneously ventilated lungs. We aimed to study the effects on ventilation and perfusion distributions of a sequential lateral positioning (30°) strategy using electrical impedance tomography imaging in a porcine experimental model of early acute respiratory distress syndrome (ARDS). We hypothesized that such strategy, including a real-time individualization of positive end-expiratory pressure (PEEP) whenever in lateral positioning, would provide attenuation of collapse in the dependent lung regions. A two-hit injury acute respiratory distress syndrome experimental model was established by lung lavages followed by injurious mechanical ventilation. Then, all animals were studied in five body positions in a sequential order, 15 min each: Supine 1; Lateral Left; Supine 2; Lateral Right; Supine 3. The following functional images were analyzed by electrical impedance tomography: ventilation distributions and regional lung volumes, and perfusion distributions. The induction of the acute respiratory distress syndrome model resulted in a marked fall in oxygenation along with low regional ventilation and compliance of the dorsal half of the lung (gravitational-dependent in supine position). Both the regional ventilation and compliance of the dorsal half of the lung greatly increased along of the sequential lateral positioning strategy, and maximally at its end. In addition, a corresponding improvement of oxygenation occurred. In conclusion, our sequential lateral positioning strategy, with sufficient positive end-expiratory pressure to prevent collapse of the dependent lung units during lateral positioning, provided a relevant diminution of collapse in the dorsal lung in a porcine experimental model of early acute respiratory distress syndrome.

6.
Sci Rep ; 12(1): 16528, 2022 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36192569

RESUMO

Real-time effects of changing body position and positive end-expiratory pressure (PEEP) on regional lung overdistension and collapse in individual patients remain largely unknown and not timely monitored. The aim of this study was to individualize PEEP in supine and prone body positions seeking to reduce lung collapse and overdistension in mechanically ventilated patients with coronavirus disease (COVID-19)-induced acute respiratory distress syndrome (ARDS). We hypothesized that prone positioning with bedside titrated PEEP would provide attenuation of both overdistension and collapse. In this prospective observational study, patients with COVID-19-induced ARDS under mechanical ventilation were included. We used electrical impedance tomography (EIT) with decremental PEEP titration algorithm (PEEPEIT-titration), which provides information on regional lung overdistension and collapse, along with global respiratory system compliance, to individualize PEEP and body position. PEEPEIT-titration in supine position followed by PEEPEIT-titration in prone position were performed. Immediately before each PEEPEIT-titration, the same lung recruitment maneuver was performed: 2 min of PEEP 24 cmH2O and driving pressure of 15 cmH2O. Forty-two PEEPEIT-titration were performed in ten patients (21 pairs supine and prone positions). We have found larger % of overdistension along the PEEP titration in prone than supine position (P = 0.042). A larger % of collapse along the PEEP titration was found in supine than prone position (P = 0.037). A smaller respiratory system compliance was found in prone than supine position (P < 0.0005). In patients with COVID-19-induced ARDS, prone body position, when compared with supine body position, decreased lung collapse at low PEEP levels, but increased lung overdistension at PEEP levels greater than 10 cm H2O.Trial registration number: NCT04460859.


Assuntos
COVID-19 , Respiração com Pressão Positiva , Atelectasia Pulmonar , Síndrome do Desconforto Respiratório , COVID-19/complicações , COVID-19/terapia , Humanos , Pulmão/patologia , Decúbito Ventral , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA