Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 28(9): 1771-1778, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31029519

RESUMO

BACKGROUND: Wear of the polyethylene glenoid component and subsequent particle-induced osteolysis remains one of the most important modes of failure of total shoulder arthroplasty. Vitamin E is added to polyethylene to act as an antioxidant to stabilize free radicals that exist as a byproduct of irradiation used to induce cross-linking. This study was performed to assess the in vitro performance of vitamin E-enhanced polyethylene compared with conventional polyethylene in a shoulder simulator model. METHODS: Vitamin E-enhanced, highly cross-linked glenoid components were compared with conventional ultrahigh-molecular-weight polyethylene glenoids, both articulating with a ceramic humeral head component using a shoulder joint simulator over 500,000 cycles. Unaged and artificially aged comparisons were performed. Volumetric wear was assessed by gravimetric measurement, and wear particle analysis was also subsequently performed. RESULTS: Vitamin E-enhanced polyethylene glenoid components were found to have significantly reduced wear rates compared with conventional polyethylene in both unaged (36% reduction) and artificially aged (49% reduction) comparisons. There were no differences detected in wear particle analysis between the 2 groups. CONCLUSION: Vitamin E-enhanced polyethylene demonstrates improved wear compared with conventional polyethylene in both unaged and artificially aged comparisons and may have clinically relevant benefits.


Assuntos
Antioxidantes , Polietileno/química , Falha de Prótese , Vitamina E , Artroplastia do Ombro/instrumentação , Cavidade Glenoide , Humanos , Cabeça do Úmero , Teste de Materiais , Polietilenos , Desenho de Prótese , Prótese de Ombro
2.
J Hand Surg Eur Vol ; 44(5): 468-474, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30727814

RESUMO

Scapholunate dissociation may occur in association with distal radial fractures and is easily missed at initial presentation. The aim of this study was to examine variances in the scapholunate distance with respect to subtypes of two-part partial articular distal radial fractures. Axial computed tomography (CT) scans of acute two-part intra-articular radial fractures were assessed retrospectively from 80 patients and compared to 20 controls. From each scan, two images were analysed to identify the scaphoid, lunate and articular fracture line in the distal radius for fracture type categorization. The images were overlaid on a standardized distal radius template and the scapholunate distance measured. Significant increase in the scapholunate distance was noted in fracture subtypes: radial styloid oblique; dorsal ulnar column; sagittal ulnar column; and volar coronal. We conclude that these findings support the need for a higher index of suspicion for scapholunate dissociation in these distal radial fracture subtypes. Level of evidence: III.


Assuntos
Fraturas Intra-Articulares/diagnóstico por imagem , Osso Semilunar/diagnóstico por imagem , Fraturas do Rádio/diagnóstico por imagem , Osso Escafoide/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Fraturas Intra-Articulares/classificação , Masculino , Pessoa de Meia-Idade , Fraturas do Rádio/classificação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
3.
J Wrist Surg ; 2(3): 255-62, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24436825

RESUMO

Background Operative fixation of intraarticular distal radius fractures is increasingly common. A greater understanding of fracture patterns will aid surgical fixation strategy. Previous studies have suggested that ligamentous insertions may less commonly be involved, but these have included heterogeneous groups of fractures and have not addressed Lister's tubercle. Purpose We hypothesize that fracture lines of distal radial intraarticular 2-part fractures have reproducible patterns. They propagate through the cortical bone between ligament origins and do not involve Lister's tubercle. Methods Axial CT scans of two-part intraarticular distal radius fractures were assessed independently by two examiners. The fractures were mapped onto a grid and the cortical breaches expressed as a percentile of the total radial width or length. The cortical breaches were compared with the ligamentous insertions on the distal and Lister's tubercle. Associated injuries were also documented. Results The cortical breaches occurred between the ligamentous insertions in 85%. Lister's tubercle was not involved in 95% of the fractures. Three major fracture patterns emerged: radial styloid, dorsal, and volar. Each major pattern had two subtypes. Associated injuries were common. Scapholunate dissociation was associated with all types, not just the radial styloid fracture pattern. Conclusions The fracture patterns of two-part intraarticular fractures mostly involved the interligamentous zones. Three major groups were identified: dorsal, volar, and radial styloid. Lister's tubercle was preserved with fractures tending to propagate radial or ulnar to this structure. We suggest conceptualizing fracture fragments as osseo-ligamentous units to aid prediction of fracture patterns and associated injury. Study Design Diagnostic III Level of Evidence 3.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA